A line driver/receiver is an interface IC that converts between TTL or CMOS logic levels and bipolar serial-line levels. Within the interface-IC hierarchy, the AD7306 belongs to the RS-232 and RS-422 transceiver family, combining transmitters and receivers in one monolithic device. Its dual-standard receiver is useful when equipment must communicate with legacy RS-232 peripherals while also supporting balanced, noise-resistant RS-422 links over longer cables.
The principal features of the AD7306 include operation from a single 5 V supply, support for both RS-232 and RS-422 signal levels, and a configurable receiver controlled by the 232/422 SEL pin. The three drivers permit simultaneous support for multiple outbound serial channels, while the receiver section returns serial data to compatible TTL or CMOS logic. The monolithic implementation also reduces the number of discrete interface components required on a board.
The AD7306 combines inverting RS-232 level shifters with RS-422 line-driver capability in the same package. According to the manufacturer datasheet, the RS-232 drivers convert TTL or CMOS levels into RS-232 output levels, while the configurable receiver path accepts either RS-232 or RS-422 inputs. This mixed-standard architecture makes the device suitable for multi-protocol control, test, instrumentation, and industrial communication equipment.
Typical uses include industrial serial controllers, test and measurement equipment, data acquisition systems, embedded control modules, and legacy computer interfaces. The RS-422 outputs can extend communication distance in electrically noisy environments when the system uses twisted-pair cabling and appropriate termination. The configurable receiver allows one connector strategy to serve both unbalanced RS-232 and balanced RS-422 equipment.
When laying out the board, keep the RS-232 and RS-422 signal paths away from clocks, switching regulators, and high-current digital returns. Configure the 232/422 SEL input before enabling the receiver and observe the logic levels required by the selected standard. Grounding, cable shielding, and any termination components must be designed for the system-level cable length and baud rate.
This page combines the manufacturer functional description, verified distributor package information, application guidance, drop-in family references, and practical design notes to support component selection and PCB implementation. It also identifies the electrical limits and compliance details that should be confirmed in the AD7306 datasheet before a new design is released.
Аналоги без доработки для AD7306AR — тот же корпус, pin-to-pin совместимость. Компоненты в других корпусах, требующие переработки PCB, исключены.
Варианты в этой серии
Модели той же серии, совместимые без доработки с AD7306AR (тот же форм-фактор и посадочное место) — отличается по Logic Interface, Mounting Type, Package, Product Type, RS-232 Drivers.
AD7306ARZ
✅ Прямая заменаУточнить цену
Открыть даташит →AD7306ANZ
✅ Прямая заменаУточнить цену
Открыть даташит →AD7306AR Максимальные параметры и электрические характеристики
| Product Type | RS-232/RS-422 line driver and receiver transceiver |
| Напряжение питания | 5 V |
| RS-232 Driver Count | 2 |
| RS-422 Driver Count | 1 |
| RS-232 Receiver Count | 1 |
| Configurable Receiver Path Count | 1 |
| Supported Standards | EIA RS-232 and EIA RS-422 |
| Logic Interface | TTL/CMOS signal levels |
| Receiver Configuration Control | 232/422 SEL pin |
| Корпус | 24-lead SOIC |
| Тип монтажа | Surface mount |
Руководство по цоколевке AD7306AR в корпусе 24-lead soic
Цоколевка для AD7306AR (корпус 24-lead soic). Этот аналоговый компонент имеет выводы входа, выхода и питания. Обратитесь к техническому описанию производителя для конфигураций выводов балансировки нуля, коррекции и разрешения. Идеально подходит для схем обработки сигналов и усилителей.
Нет подробных данных о распиновке для AD7306AR.
Обратитесь к даташиту для полной конфигурации выводов.
Типичное применение
AD7306AR подходит для 6 применениеs: Industrial Serial Control Interfaces, Test and Measurement Equipment, RS-232 and RS-422 Dual-Standard Gateways, Embedded Data Acquisition Modules, Legacy Computer Peripherals, Point-of-Sale and Service Terminals.
Industrial Serial Control Interfaces
The AD7306AR fits industrial controllers that must communicate with both legacy RS-232 equipment and RS-422 modules. Its two RS-232 drivers, one RS-422 driver, and two receiver paths allow several serial links to share one 5 V device instead of requiring separate RS-232 and RS-422 transceiver packages. Configure the selectable receiver through the 232/422 SEL pin to match each attached device. Keep the serial traces away from switching nodes and provide a solid ground reference so the 5 V interface remains stable in electrically noisy cabinets.
Рекомендуется
Test and Measurement Equipment
Instrumentation can use the AD7306AR to connect a controller to older RS-232 test gear while retaining balanced RS-422 links for bench peripherals. The fixed RS-232 and RS-422 outputs support multiple outbound command channels, and the configurable receiver accepts either signal standard. This is useful in automated test systems that mix instrument vintages. Place the interface section near the external connector, keep return paths continuous, and follow the manufacturer application guidance for bypass capacitance and interface protection.
Рекомендуется
RS-232 and RS-422 Dual-Standard Gateways
A protocol gateway built around the AD7306AR can accept RS-232 from a personal computer and RS-422 from a machine controller without duplicating receiver circuitry. The dedicated RS-232 receiver handles one standard while the configurable receiver path is assigned by the 232/422 SEL pin. The three-driver arrangement also supports pass-through and control signals. For reliable operation, isolate the serial connector region from switching regulators and route balanced RS-422 pairs together to minimize differential pickup.
Рекомендуется
Embedded Data Acquisition Modules
The AD7306AR can provide a compact communication front end for data acquisition modules that must accept commands over RS-232 and sensor or controller data over RS-422. Two RS-232 drivers can carry status and handshake signaling, while the RS-422 driver supports a longer-distance channel. Because the device operates from a single 5 V rail, it integrates easily into control boards dominated by 5 V digital logic. Apply the datasheet input thresholds and output-level limits when connecting to nonstandard receiver devices.
Рекомендуется
Legacy Computer Peripherals
The AD7306AR is useful in industrial computers and peripheral controllers that retain an RS-232 port but also need RS-422 connectivity for external equipment. Its mixed driver outputs simplify common-mode, grounding, and cable-interface decisions when both standards appear on one assembly. The configurable receiver allows the same interface logic to serve DB-style RS-232 equipment and balanced remote nodes. Confirm connector pin assignments in the manufacturer datasheet and avoid sharing high-current return paths with unprotected serial inputs.
Рекомендуется
Point-of-Sale and Service Terminals
Service terminals and point-of-sale equipment can use the AD7306AR to maintain an RS-232 connection to a local console while offering an RS-422 path to a peripheral controller or longer cable run. The multiple drivers provide flexible command and status channels, and the selectable receiver supports both interface types from one package. Design the board with the serial connector near the transceiver, provide filtering only after confirming the supported input levels, and verify the selected configuration level during power-up testing.
Рекомендуется
Сводка рекомендуемых товаров
Справочные инженерные данные для AD7306AR — сравнение, рекомендации по проектированию и информация о соответствии.
Руководство по выбору
Сравнение с аналогами
| Параметр | Этот товар | AD7306ARZ | AD7306ANZ |
|---|---|---|---|
| Package | 24-lead SOIC | 24-lead SOIC - same footprint | 24-lead SOIC - same footprint |
| Brand | Analog Devices | Analog Devices | Analog Devices |
| Product Type | RS-232/RS-422 line driver and receiver | RS-232/RS-422 line driver and receiver | RS-232/RS-422 line driver and receiver |
| Supply Voltage | 5 V | 5 V | 5 V |
| RS-232 Drivers | 2 | 2 | 2 |
| RS-422 Drivers | 1 | 1 | 1 |
| Receiver Paths | 1 dedicated RS-232 receiver and 1 configurable receiver | 1 dedicated RS-232 receiver and 1 configurable receiver | 1 dedicated RS-232 receiver and 1 configurable receiver |
| Receiver Mode Control | 232/422 SEL pin | 232/422 SEL pin | 232/422 SEL pin |
| Logic Interface | TTL/CMOS | TTL/CMOS | TTL/CMOS |
Ключевые отличия
- Combines two serial standards in one device (против AD7306ARZ)
- Provides three outbound driver channels (против AD7306ANZ)
- Supports two receiver paths with selectable standard (против AD7306ARZ)
Заметки по проектированию
Place the AD7306AR close to the external serial connector and route each RS-422 differential pair as a coupled pair with a continuous ground reference beneath or beside it. Keep the 232/422 SEL trace away from driver outputs. This arrangement reduces the differential-to-common-mode conversion that can corrupt data when the cable introduces external noise.
Do not treat the 232/422 SEL pin as a general-purpose speed or polarity control. It determines the standard accepted by the configurable receiver path, and an incorrect setting can make valid data appear invalid. Verify the selected logic level, the connected equipment standard, and the corresponding receiver thresholds during hardware bring-up using the manufacturer application circuit.
Separate the serial interface from switching-regulator loops, relays, clock outputs, and high-current digital returns. Connect the connector ground to the interface ground with a low-impedance path, and use the manufacturer's recommended bypass and protection arrangements. This is particularly important in the same RS-232 and RS-422 assembly because unbalanced RS-232 signals are more susceptible to local coupling.
Информация о соответствии
Exact compliance declarations must be confirmed for the selected AD7306AR order code and regional supply chain. The product is an industrial interface IC rather than an automotive-qualified device.