Analog Devices

AD7306AR - 5V RS-232/RS-422 Transceiver | Analog Devices

MPN: AD7306AR ✓ 啟用中
5 V Vdss EIA RS-232 and EIA RS-422 Rds(on) 24-lead SOIC Package
MOQ: 1 |

AD7306AR 概覽

The Analog Devices AD7306AR is a 5 V monolithic RS-232 and RS-422 line driver/receiver in a 24-lead SOIC package. It provides two RS-232 drivers, one RS-422 driver, one RS-232 receiver, and one configurable receiver path that can operate as either RS-232 or RS-422. The 232/422 SEL pin selects the standard for the configurable receiver, allowing one circuit to support both EIA RS-232 and RS-422 interfaces.

A line driver/receiver is an interface IC that converts between TTL or CMOS logic levels and bipolar serial-line levels. Within the interface-IC hierarchy, the AD7306 belongs to the RS-232 and RS-422 transceiver family, combining transmitters and receivers in one monolithic device. Its dual-standard receiver is useful when equipment must communicate with legacy RS-232 peripherals while also supporting balanced, noise-resistant RS-422 links over longer cables.

The principal features of the AD7306 include operation from a single 5 V supply, support for both RS-232 and RS-422 signal levels, and a configurable receiver controlled by the 232/422 SEL pin. The three drivers permit simultaneous support for multiple outbound serial channels, while the receiver section returns serial data to compatible TTL or CMOS logic. The monolithic implementation also reduces the number of discrete interface components required on a board.

The AD7306 combines inverting RS-232 level shifters with RS-422 line-driver capability in the same package. According to the manufacturer datasheet, the RS-232 drivers convert TTL or CMOS levels into RS-232 output levels, while the configurable receiver path accepts either RS-232 or RS-422 inputs. This mixed-standard architecture makes the device suitable for multi-protocol control, test, instrumentation, and industrial communication equipment.

Typical uses include industrial serial controllers, test and measurement equipment, data acquisition systems, embedded control modules, and legacy computer interfaces. The RS-422 outputs can extend communication distance in electrically noisy environments when the system uses twisted-pair cabling and appropriate termination. The configurable receiver allows one connector strategy to serve both unbalanced RS-232 and balanced RS-422 equipment.

When laying out the board, keep the RS-232 and RS-422 signal paths away from clocks, switching regulators, and high-current digital returns. Configure the 232/422 SEL input before enabling the receiver and observe the logic levels required by the selected standard. Grounding, cable shielding, and any termination components must be designed for the system-level cable length and baud rate.

This page combines the manufacturer functional description, verified distributor package information, application guidance, drop-in family references, and practical design notes to support component selection and PCB implementation. It also identifies the electrical limits and compliance details that should be confirmed in the AD7306 datasheet before a new design is released.

直接替換替代品,適用於 AD7306AR — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。

此系列的變體

與下列產品可直接替換的同系列型號: AD7306AR (相同外形與佔位) — 差異在於 Logic Interface, Mounting Type, Package, Product Type, RS-232 Drivers.

Analog Devices
Logic Interface: TTL signal levels
Mounting Type: Through-hole
RS-232 Drivers: 2 channels
比較對象 AD7306AR →
Analog Devices
Logic Interface: TTL signal levels
Package: 24-pin SOIC
Product Type: RS-232/RS-422 line driver/receiver transceiver
比較對象 AD7306AR →

AD7306ARZ

✅ 直接替換
Analog Devices
📦 24-lead SOIC
RS-232/RS-422 line driver/receiver transceiver · 5 V · EIA RS-232 and EIA RS-422 · 3 drivers · 3 receivers · 2 dedicated RS-232 drivers · 1 RS-422 driver · 1 dedicated RS-232 receiver

聯絡詢價

查看資料表 →

AD7306ANZ

✅ 直接替換
Analog Devices
📦 24-lead SOIC
5 V · 4.75 V to 5.25 V · 3 channels · 3 channels · 2 channels · 1 channel · 1 channel · 1 channel

聯絡詢價

查看資料表 →

AD7306AR 最大額定值與電氣特性

Product Type RS-232/RS-422 line driver and receiver transceiver
供應電壓 5 V
RS-232 Driver Count 2
RS-422 Driver Count 1
RS-232 Receiver Count 1
Configurable Receiver Path Count 1
Supported Standards EIA RS-232 and EIA RS-422
Logic Interface TTL/CMOS signal levels
Receiver Configuration Control 232/422 SEL pin
封裝 24-lead SOIC
安裝類型 Surface mount

AD7306AR 24-lead soic 腳位配置指南

AD7306AR(24-lead soic 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。

AD7306AR 的 24-lead soic 封裝腳位圖

無詳細腳位定義資料: AD7306AR.

請參閱 資料表 以查看完整腳位配置。

典型應用

AD7306AR 適用於 6 應用s: Industrial Serial Control Interfaces, Test and Measurement Equipment, RS-232 and RS-422 Dual-Standard Gateways, Embedded Data Acquisition Modules, Legacy Computer Peripherals, Point-of-Sale and Service Terminals.

🏭

Industrial Serial Control Interfaces

The AD7306AR fits industrial controllers that must communicate with both legacy RS-232 equipment and RS-422 modules. Its two RS-232 drivers, one RS-422 driver, and two receiver paths allow several serial links to share one 5 V device instead of requiring separate RS-232 and RS-422 transceiver packages. Configure the selectable receiver through the 232/422 SEL pin to match each attached device. Keep the serial traces away from switching nodes and provide a solid ground reference so the 5 V interface remains stable in electrically noisy cabinets.

🔧

Test and Measurement Equipment

Instrumentation can use the AD7306AR to connect a controller to older RS-232 test gear while retaining balanced RS-422 links for bench peripherals. The fixed RS-232 and RS-422 outputs support multiple outbound command channels, and the configurable receiver accepts either signal standard. This is useful in automated test systems that mix instrument vintages. Place the interface section near the external connector, keep return paths continuous, and follow the manufacturer application guidance for bypass capacitance and interface protection.

🌐

RS-232 and RS-422 Dual-Standard Gateways

A protocol gateway built around the AD7306AR can accept RS-232 from a personal computer and RS-422 from a machine controller without duplicating receiver circuitry. The dedicated RS-232 receiver handles one standard while the configurable receiver path is assigned by the 232/422 SEL pin. The three-driver arrangement also supports pass-through and control signals. For reliable operation, isolate the serial connector region from switching regulators and route balanced RS-422 pairs together to minimize differential pickup.

📊

Embedded Data Acquisition Modules

The AD7306AR can provide a compact communication front end for data acquisition modules that must accept commands over RS-232 and sensor or controller data over RS-422. Two RS-232 drivers can carry status and handshake signaling, while the RS-422 driver supports a longer-distance channel. Because the device operates from a single 5 V rail, it integrates easily into control boards dominated by 5 V digital logic. Apply the datasheet input thresholds and output-level limits when connecting to nonstandard receiver devices.

🖥️

Legacy Computer Peripherals

The AD7306AR is useful in industrial computers and peripheral controllers that retain an RS-232 port but also need RS-422 connectivity for external equipment. Its mixed driver outputs simplify common-mode, grounding, and cable-interface decisions when both standards appear on one assembly. The configurable receiver allows the same interface logic to serve DB-style RS-232 equipment and balanced remote nodes. Confirm connector pin assignments in the manufacturer datasheet and avoid sharing high-current return paths with unprotected serial inputs.

💳

Point-of-Sale and Service Terminals

Service terminals and point-of-sale equipment can use the AD7306AR to maintain an RS-232 connection to a local console while offering an RS-422 path to a peripheral controller or longer cable run. The multiple drivers provide flexible command and status channels, and the selectable receiver supports both interface types from one package. Design the board with the serial connector near the transceiver, provide filtering only after confirming the supported input levels, and verify the selected configuration level during power-up testing.

What is the AD7306AR and what standards does it support?
The AD7306AR is a 5 V monolithic line driver/receiver that converts between TTL or CMOS logic and EIA RS-232 or RS-422 serial levels. According to the Analog Devices AD7306 product page and datasheet, the device contains two RS-232 drivers, one RS-422 driver, one RS-232 receiver, and one receiver path configurable as RS-232 or RS-422 through the 232/422 SEL pin.
How many drivers and receivers are integrated in the AD7306AR?
The AD7306AR integrates two RS-232 drivers, one RS-422 driver, one RS-232 receiver, and one configurable receiver path. The configurable path can operate as either an RS-232 or RS-422 receiver, selected by the 232/422 SEL pin. This arrangement allows a single 24-lead SOIC device to support several outbound channels and inbound serial connections.
How does the 232/422 SEL pin configure the AD7306AR?
The 232/422 SEL pin selects whether the configurable receiver path operates as an RS-232 or RS-422 receiver. According to the manufacturer datasheet, this pin allows one package to meet both serial standards without duplicating the receiver circuitry. Set the selection level to match the attached equipment and cable interface before operating the communication link.
Where can I download the AD7306AR datasheet PDF?
The official AD7306 datasheet PDF is available from the Analog Devices product page at https://www.analog.com/media/en/technical-documentation/data-sheets/AD7306.pdf. Use the manufacturer document for the complete pin-description table, recommended application circuit, electrical characteristics, operating limits, and package dimensions before laying out the PCB.
What is the AD7306AR package and pin count?
The AD7306AR is supplied in a 24-lead SOIC surface-mount package. The package identity is confirmed by the verified distributor listing and by the SOIC-24 comparison information for the AD7306 family. Use the pin-description table in the manufacturer datasheet when assigning signals and planning the board layout.
Where can I buy AD7306AR and how do I request a quotation?
Use the Request a Quote form on this page to ask for AD7306AR availability, current pricing, minimum order quantity, and delivery scheduling. The device is listed in a 24-lead SOIC package, and the same form can be used to request manufacturer-packaging quantities and any traceable-production requirements for the assembly.
What is the current lead time for AD7306AR?
Lead time depends on factory inventory, scheduled production, package quantity, and current purchasing activity. Request the latest AD7306AR lead time through the Request a Quote form on this page rather than relying on an archived schedule. Include the required quantity, date code constraints, and whether reel or tube packing is acceptable.
Is the AD7306AR currently in stock?
Inventory changes rapidly for interface ICs, so the AD7306AR quantity should be confirmed through the Request a Quote form on this page. Provide the required order quantity and acceptable delivery date so the current factory and channel position can be checked against your build schedule.
What is the difference between AD7306AR and AD7306ARZ?
The AD7306AR and AD7306ARZ belong to the same AD7306 family and use the same 24-lead SOIC footprint, with both providing RS-232 and RS-422 driver and receiver functions. Their order codes can differ in temperature grade, qualification, or regional compliance treatment, so verify those details in the AD7306 datasheet and product ordering guide before substitution.
When should I choose the AD7306AR instead of a single-standard RS-232 transceiver?
Choose the AD7306AR when one board must support both RS-232 and RS-422 connections or requires more than one outbound driver. It combines two RS-232 drivers, one RS-422 driver, an RS-232 receiver, and a selectable receiver in one 5 V package, reducing component count versus separate standard-specific transceivers.
Can AD7306AR be used with both RS-232 and RS-422 equipment?
Yes, the AD7306AR can support RS-232 and RS-422 interfaces in the same system. The fixed RS-232 driver, fixed RS-422 driver, dedicated RS-232 receiver, and configurable receiver provide multiple standard-specific paths. The 232/422 SEL pin determines whether the configurable receiver interprets an RS-232 or RS-422 input.
What can replace the AD7306AR on an existing PCB?
A direct replacement must use the same 24-lead SOIC footprint and provide compatible RS-232 and RS-422 driver and receiver functions at the same 5 V supply. The AD7306ARZ is the closest documented same-family reference, but confirm temperature grade, qualification, enable or shutdown behavior, and signal-level timing before treating it as a drop-in substitution.
What are the key specifications of AD7306AR that engineers should know?
The key AD7306AR specifications are its 5 V supply, 24-lead SOIC package, two RS-232 drivers, one RS-422 driver, one RS-232 receiver, and one receiver configurable by the 232/422 SEL pin. The manufacturer also identifies the RS-232 drivers as inverting level shifters that convert TTL or CMOS inputs into RS-232 output levels.
How should the AD7306AR be laid out for reliable RS-422 communication?
Route AD7306AR driver and receiver traces as controlled-impedance interconnects where practical, keep the 232/422 SEL trace away from serial outputs, and provide a continuous ground reference. For RS-422 links, follow the termination and shield recommendations in the manufacturer datasheet and the system cable specification rather than assuming a universal termination value.
Is AD7306AR compliant with RoHS and REACH?
RoHS and REACH status must be confirmed for the exact AD7306AR order code and its current material declaration. The AD7306 family is offered in multiple order codes, and compliance treatments can vary by region and packaging variant. Review the current manufacturer product page and Declaration of Conformity for the ordered configuration.

工程參考資料,適用於 AD7306AR — 比較、設計指引及合規資訊。

選型指南

Choose the AD7306AR when a 5 V board must support RS-232 and RS-422 in the same interface section and needs more than one outbound channel. Its two RS-232 drivers, one RS-422 driver, dedicated RS-232 receiver, and configurable receiver provide useful flexibility in industrial controllers, test equipment, and gateways. Choose AD7306ARZ when procurement requires the related order code and the manufacturer ordering guide confirms compatible temperature, qualification, and regional treatment. Choose AD7306ANZ only after verifying its grade-specific operating limits against the intended ambient environment. For designs using a single serial standard, a dedicated standard-specific transceiver may be simpler. For any substitution, retain the 24-lead SOIC footprint and verify power-supply requirements, logic thresholds, propagation timing, output levels, receiver enable behavior, and the 232/422 SEL polarity before releasing the PCB.

與替代品比較

參數 本產品 AD7306ARZ AD7306ANZ
Package 24-lead SOIC 24-lead SOIC - same footprint 24-lead SOIC - same footprint
Brand Analog Devices Analog Devices Analog Devices
Product Type RS-232/RS-422 line driver and receiver RS-232/RS-422 line driver and receiver RS-232/RS-422 line driver and receiver
Supply Voltage 5 V 5 V 5 V
RS-232 Drivers 2 2 2
RS-422 Drivers 1 1 1
Receiver Paths 1 dedicated RS-232 receiver and 1 configurable receiver 1 dedicated RS-232 receiver and 1 configurable receiver 1 dedicated RS-232 receiver and 1 configurable receiver
Receiver Mode Control 232/422 SEL pin 232/422 SEL pin 232/422 SEL pin
Logic Interface TTL/CMOS TTL/CMOS TTL/CMOS

主要差異化特點

  • Combines two serial standards in one device (對比AD7306ARZ)
  • Provides three outbound driver channels (對比AD7306ANZ)
  • Supports two receiver paths with selectable standard (對比AD7306ARZ)

設計說明

Place the AD7306AR close to the external serial connector and route each RS-422 differential pair as a coupled pair with a continuous ground reference beneath or beside it. Keep the 232/422 SEL trace away from driver outputs. This arrangement reduces the differential-to-common-mode conversion that can corrupt data when the cable introduces external noise.

Do not treat the 232/422 SEL pin as a general-purpose speed or polarity control. It determines the standard accepted by the configurable receiver path, and an incorrect setting can make valid data appear invalid. Verify the selected logic level, the connected equipment standard, and the corresponding receiver thresholds during hardware bring-up using the manufacturer application circuit.

Separate the serial interface from switching-regulator loops, relays, clock outputs, and high-current digital returns. Connect the connector ground to the interface ground with a low-impedance path, and use the manufacturer's recommended bypass and protection arrangements. This is particularly important in the same RS-232 and RS-422 assembly because unbalanced RS-232 signals are more susceptible to local coupling.

合規資訊

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
無鉛
Unknown
無鹵
Unknown
衝突礦產
Unknown

Exact compliance declarations must be confirmed for the selected AD7306AR order code and regional supply chain. The product is an industrial interface IC rather than an automotive-qualified device.

資料驗證日期: 2026-11-25 — 資料由 XAIPART 元件工程團隊驗證及整理

相關搜尋

AD7306AR datasheet AD7306AR datasheet pdf AD7306AR pinout AD7306AR SOIC-24 AD7306AR RS-232 RS-422 AD7306AR 232/422 SEL AD7306AR equivalent AD7306AR replacement AD7306AR vs AD7306ARZ AD7306AR price AD7306AR stock Analog Devices AD7306AR

相關元件與詞彙

Analog Devices AD7306AR AD7306ARZ AD7306ANZ line driver/receiver transceiver interface IC RS-232 RS-422 EIA RS-232 EIA RS-422 TTL logic CMOS logic 232/422 SEL SOIC-24 surface mount industrial communication data acquisition test and measurement differential signaling RoHS REACH
快速報價 RFQ
請填寫完整詳細資料 — 我們的業務團隊將於 24 小時內回覆
料號 製造商 封裝 QTY 目標價格 小計
✓
報價已提交!

我們將於 24 小時內回覆您的電子郵件

1
詢價已提交
2
已收到報價
3
已下單
4
付款
5
已出貨
6
已送達
檢視詢價單詳情