AD7574AQ - 8-Bit 15µs SAR ADC | Analog Devices
Артикул: AD7574AQ ✓ АктивенAD7574AQ Обзор
An ADC is a data-acquisition IC that converts an analog voltage into a digital code for processing, measurement, or control. The AD7574 belongs to the SAR ADC family, which performs conversion through successive comparison steps and provides predictable sampling behavior for instrumentation, industrial control, and embedded applications. Its parallel interface allows the eight-bit result to be read directly by compatible microprocessor or bus circuitry.
The principal features of the AD7574AQ include 8-bit resolution, one analog input, a 15 µs conversion time, parallel output, ratiometric operation, and single-supply operation from 5 V. The manufacturer product page identifies the converter as microprocessor compatible and specifically intended for memory-mapped interfacing similar to static RAM or ROM. These characteristics make it suitable for legacy acquisition boards and embedded control systems with parallel data buses.
Ratiometric operation means the converter can use a reference proportional to the measured sensor excitation or supply. When the excitation drifts, the digital result can track that drift, which is useful for resistive bridges, potentiometers, and other sensors whose output depends on excitation voltage. The manufacturer datasheet states that the AD7574 is guaranteed to meet published transfer-accuracy specifications for conversion times down to 15 µs within the indicated operating region.
Typical applications include process-control instrumentation, digital panel meters, industrial sensor interfaces, laboratory measurement equipment, and embedded legacy systems. A practical design must account for the parallel interface timing, analog input settling, reference accuracy, and the required 5 V supply. Input and reference networks should use short, low-noise routes, while decoupling capacitors should be placed close to the corresponding device pins.
The principal trade-off is resolution: 8-bit resolution provides limited measurement granularity, while the 15 µs conversion time is suitable for many control and monitoring loops but not high-speed waveform acquisition. Existing 24-CDIP layouts can use the AD7574AQ when an 8-bit, parallel-interface SAR converter with 15 µs conversion performance is required.
This page combines the manufacturer specifications, sourcing guidance, interface considerations, and same-package family options into a practical engineering reference for evaluating the AD7574AQ in legacy embedded and industrial designs.
Аналоги без доработки для AD7574AQ — тот же корпус, pin-to-pin совместимость. Компоненты в других корпусах, требующие переработки PCB, исключены.
Варианты в этой серии
Модели той же серии, совместимые без доработки с AD7574AQ (тот же форм-фактор и посадочное место) — отличается по Interface Type, Package, Resolution.
AD7574BQ
✅ Прямая замена ⚠️ Характеристики не провереныУточнить цену
Открыть даташит →AD7574SQ
✅ Прямая замена ⚠️ Характеристики не провереныУточнить цену
Открыть даташит →AD7574BZ
✅ Прямая замена ⚠️ Характеристики не проверены📋 Справочный аналог (нет в каталоге)
AD7574SZ
✅ Прямая замена ⚠️ Характеристики не проверены📋 Справочный аналог (нет в каталоге)
AD7574AQ
✅ Прямая замена ⚠️ Характеристики не провереныУточнить цену
Открыть даташит →AD7574AQ Максимальные параметры и электрические характеристики
| Разрешение | 8 bit |
| Analog Input Count | 1 input |
| Conversion Architecture | SAR (successive approximation) |
| Conversion Time | 15 µs |
| Тип интерфейса | 8-bit parallel microprocessor-compatible interface |
| Напряжение питания | 5 V |
| Reference Mode | Ratiometric |
| Process Technology | CMOS |
| Корпус | 24-CDIP |
| Тип монтажа | Through-hole |
| Input Type | Single-channel analog input |
| Transfer Accuracy Guarantee | Specified for conversion times down to 15 µs |
| Статус RoHS | unknown |
| REACH Status | unknown |
| Lead-Free Status | unknown |
Руководство по цоколевке AD7574AQ в корпусе 24-cdip
Цоколевка для AD7574AQ (корпус 24-cdip). Этот аналоговый компонент имеет выводы входа, выхода и питания. Обратитесь к техническому описанию производителя для конфигураций выводов балансировки нуля, коррекции и разрешения. Идеально подходит для схем обработки сигналов и усилителей.
Нет подробных данных о распиновке для AD7574AQ.
Обратитесь к даташиту для полной конфигурации выводов.
Типичное применение
AD7574AQ подходит для 6 применениеs: Industrial Process Measurement, Digital Panel Meter, Resistive Sensor Interface, Laboratory Instrumentation, Embedded Control System, Legacy Equipment Maintenance.
Industrial Process Measurement
The AD7574AQ fits legacy industrial process controllers that acquire a slowly changing analog process variable through an 8-bit parallel bus. Its 15 µs conversion time is suitable for monitoring and supervisory control loops, while the single 5 V supply simplifies power distribution around older logic systems. Ratiometric operation can improve measurement repeatability when the sensor excitation and converter reference vary proportionally. The 24-CDIP package also supports repair of equipment designed with through-hole assembly rather than a surface-mount redesign.
Рекомендуется
Digital Panel Meter
The AD7574AQ can form the acquisition front end of a digital panel meter for temperature, pressure, level, or position monitoring. An 8-bit result is adequate for many display resolutions where the measured value requires coarse digitizing rather than laboratory precision. The parallel interface allows straightforward connection to a microprocessor display controller, and the 15 µs conversion time supports rapid scanning of several channels through external multiplexing hardware.
Рекомендуется
Resistive Sensor Interface
The AD7574AQ is well suited to legacy resistive-sensor interfaces because its ratiometric operation can compensate for proportional changes in sensor excitation. The same principle applies to strain-gauge bridges, resistive position sensors, and potentiometric dividers when the converter reference follows the excitation. This does not remove amplifier, linearization, or input-protection requirements, but it can reduce system sensitivity to excitation drift while preserving the familiar 5 V parallel-interface architecture.
Рекомендуется
Laboratory Instrumentation
The AD7574AQ can support basic laboratory measurement equipment where an 8-bit, moderately fast conversion result is adequate for calibration, status indication, or supervisory diagnostics. Its 15 µs conversion time permits repeated readings faster than many panel-meter systems require, and the microprocessor-compatible parallel interface simplifies connection to older test-controller hardware. Designers should account for the limited 8-bit resolution and use suitable input buffering when the source impedance, grounding, or noise level would otherwise impair conversion accuracy.
Рекомендуется
Embedded Control System
The AD7574AQ serves embedded control systems that retain an 8-bit parallel data bus and require a dedicated analog measurement channel. The 15 µs conversion time supports supervisory control tasks such as setpoint comparison, actuator feedback, and analog limit detection, while the 5 V supply aligns with established logic platforms. The 24-CDIP footprint is especially useful for equipment upgrades where replacing the host processor is impractical. Firmware should sample at an interval no faster than the complete read-and-convert sequence permits.
Рекомендуется
Legacy Equipment Maintenance
The AD7574AQ is particularly useful for maintaining older industrial, medical, or test equipment built around a 24-CDIP ADC footprint. Its 8-bit parallel interface and 15 µs conversion timing preserve the functional role of the original converter without forcing a mixed-signal board redesign. Replacement work should verify pin assignments, timing, reference implementation, and supply decouping against the manufacturer datasheet. This approach reduces mechanical and firmware disruption while retaining the established 5 V system architecture.
Рекомендуется
Сводка рекомендуемых товаров
Справочные инженерные данные для AD7574AQ — сравнение, рекомендации по проектированию и информация о соответствии.
Руководство по выбору
Сравнение с аналогами
| Параметр | Этот товар | AD7574BQ | AD7574SQ | AD7574BZ | AD7574SZ |
|---|---|---|---|---|---|
| Package | 24-CDIP | 24-CDIP | 24-CDIP | 24-CDIP | 24-CDIP |
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Resolution | 8 bit | 8 bit | 8 bit | 8 bit | 8 bit |
| Conversion Time | 15 µs | 15 µs | 15 µs | 15 µs | 15 µs |
| Supply Voltage | 5 V | 5 V | 5 V | 5 V | 5 V |
| Interface | Parallel microprocessor-compatible | Parallel microprocessor-compatible | Parallel microprocessor-compatible | Parallel microprocessor-compatible | Parallel microprocessor-compatible |
| Input Count | 1 input | 1 input | 1 input | 1 input | 1 input |
| Reference Mode | Ratiometric | Ratiometric | Ratiometric | Ratiometric | Ratiometric |
Ключевые отличия
- Parallel legacy-system integration (против AD7574BQ)
- Ratiometric measurement support (против AD7574SQ)
- Predictable conversion interval (против AD7574BZ)
Заметки по проектированию
Route the analog input and reference directly to the AD7574AQ with short PCB traces, adequate ground-plane return paths, and minimal exposure to switching nodes. Because this is an 8-bit converter, noise and source-impedance errors can consume a meaningful portion of the available code range. Use the input-network and reference values recommended in the manufacturer datasheet rather than relying on generic RC values.
Preserve the 24-CDIP footprint and pin numbering when making a replacement rather than assuming that any 8-bit ADC is interchangeable. Confirm the AD7574AQ bus and control signals against the manufacturer pin-description table. In a new legacy-style design, place supply-decoupling capacitors close to the device, provide a clean analog ground connection, and isolate analog and digital return currents where the board architecture permits.
Do not treat the 15 µs conversion time as permission to issue an unlimited sequence of back-to-back reads. Host-bus overhead, control-signal setup, output timing, and any external multiplexer settling time also affect the usable sampling rate. Review the timing diagram in the manufacturer datasheet and avoid beginning a new conversion before the previous result and control sequence have completed.
Информация о соответствии
The manufacturer product page and datasheet excerpts do not state RoHS, REACH, lead-free, halogen-free, conflict-minerals, or automotive qualification status for AD7574AQ.