Analog Devices

AD565AKD/+ - 12-Bit Mono DAC, 24-CDIP | Analog Devices

Артикул: AD565AKD/+ ✗ Снят с производства
24-CDIP Package
MOQ: 1 |

AD565AKD/+ Обзор

The Analog Devices AD565AKD/+ is a 12-bit monolithic digital-to-analog converter with one output channel in a 24-lead ceramic DIP package. It combines a 12-bit DAC core with a buried Zener reference, providing a defined voltage reference for analog signal generation. The AD565A family is marked by Analog Devices as not recommended for new designs, so the AD565AKD/+ is primarily suited to maintenance, legacy-system support, and previously qualified industrial or instrumentation designs.

A digital-to-analog converter is a data-conversion IC that transforms a digital code into a proportional analog voltage or current. In the broader electronics hierarchy, a DAC belongs to data-converter ICs, interface electronics, and power-management-adjacent signal-chain components. The AD565AKD/+ provides the final analog output stage in systems that also contain digital control logic, a clock interface, reference circuitry, output buffering, and analog signal conditioning.

The headline features of the AD565AKD/+ are its 12-bit conversion resolution, one DAC channel, and 24-CDIP package. Its monolithic implementation consolidates the converter into a single IC, while the buried Zener reference supplies a low-noise internal reference with long-term stability and temperature-drift characteristics designed for precision applications. The manufacturer describes the AD565A as a high-speed 12-bit monolithic DAC family, making it suitable for compact analog-output subsystems where discrete reference and converter stages would otherwise increase component count.

The AD565AKD/+ uses the same AD565A converter family identified on the Analog Devices product page. Exact settling time, differential nonlinearity, integral nonlinearity, DNL monotonicity, reference voltage, output range, supply requirements, and digital-interface timing must be confirmed in the manufacturer datasheet before a new circuit is released. These parameters determine the usable code-to-voltage relationship, allowable update rate, output impedance requirements, and the amount of reconstruction filtering needed after the DAC.

Typical uses include industrial process-control output modules, laboratory instrumentation, programmable test equipment, legacy data-acquisition systems, and embedded analog signal generators. In a process-control design, the DAC can produce a command voltage that is filtered and scaled before driving an actuator or measurement front end. In test equipment, it can synthesize calibration and stimulus levels. Because the AD565A is not recommended for new designs, engineers should also consider whether a currently recommended converter would reduce long-term sourcing and redesign risk.

For implementation, place the output-filter network close to the converter and route analog signals away from high-speed digital transitions. Confirm the package pin assignments, analog and digital ground strategy, reference bypass requirements, and output-loading limits in the manufacturer datasheet. Do not substitute an alternative solely because it has the same resolution; verify pinout, interface logic, reference arrangement, output range, and supply requirements first.

This page combines the manufacturer product information, lifecycle position, sourcing guidance, technical comparisons, and design cautions for engineers supporting AD565AKD/+ systems. It also identifies why a similarly packaged converter may require interface review, and why legacy design decisions should be separated from the requirements of a new, forward-looking analog-output platform.

Аналоги без доработки для AD565AKD/+ — тот же корпус, pin-to-pin совместимость. Компоненты в других корпусах, требующие переработки PCB, исключены.

Варианты в этой серии

Модели той же серии, совместимые без доработки с AD565AKD/+ (тот же форм-фактор и посадочное место) — отличается по Resolution.

Analog Devices
Resolution: 12 bits

AD565AJD/+

✅ Прямая замена
Analog Devices
📦 24-CDIP
12 bits · 1 converter · 1 output · Current steering · Parallel · 0.35 us · Buried Zener reference · Long-term stability and low temperature drift

Уточнить цену

Открыть даташит →

AD565AKD/+ Максимальные параметры и электрические характеристики

Converter Type 12-bit monolithic digital-to-analog converter
Разрешение 12 bit
Number of Channels 1 channel
Architecture Monolithic DAC
Internal Reference Buried Zener reference
Reference Characteristics Low-noise, long-term-stable reference with temperature-drift characteristics comparable to discrete reference diodes
Корпус 24-CDIP
Количество выводов 24 pins
Тип монтажа Through-hole
Product Lifecycle Recommendation Not recommended for new designs

Руководство по цоколевке AD565AKD/+ в корпусе 24-cdip

Цоколевка для AD565AKD/+ (корпус 24-cdip). Этот аналоговый компонент имеет выводы входа, выхода и питания. Обратитесь к техническому описанию производителя для конфигураций выводов балансировки нуля, коррекции и разрешения. Идеально подходит для схем обработки сигналов и усилителей.

Схема цоколевки корпуса 24-cdip для AD565AKD/+

Нет подробных данных о распиновке для AD565AKD/+.

Обратитесь к даташиту для полной конфигурации выводов.

Типичное применение

AD565AKD/+ подходит для 6 применениеs: Industrial Process-Control Output, Laboratory Instrument Signal Source, Programmable Test and Calibration Systems, Legacy Data-Acquisition Analog Output, Precision Analog Signal Generation, Legacy Control-System Spare Part.

🏭

Industrial Process-Control Output

The AD565AKD/+ fits legacy process-control modules that require a 12-bit command voltage for actuator, valve, or test-signal interfaces. Its single-channel monolithic DAC output simplifies the analog-generation stage while the buried Zener reference provides an internal reference with low-noise, long-term-stability, and temperature-drift characteristics designed for precision work. In an installed control system, the converter can be driven by existing digital control logic and followed by an analog reconstruction or output-conditioning network. Because the AD565A family is not recommended for new designs, engineers should prefer this device when preserving an existing board is more valuable than starting with a currently supported platform. Verify the exact supply, output range, settling time, and load-driving limits in the manufacturer datasheet before adding it to a new control board.

🔧

Laboratory Instrument Signal Source

The AD565AKD/+ can generate controlled analog levels in laboratory instruments that already use the AD565A interface and 24-CDIP layout. The 12-bit resolution provides 4096 digital code positions, while the single output channel is sufficient for calibration, excitation, offset, or reference-control functions. Its buried Zener reference removes the need for a separate reference arrangement in compatible legacy circuits and supports repeatable output behavior over time. The converter is normally paired with a low-pass or reconstruction filter to remove digital-code transitions before the signal reaches the analog output connector. For new instruments, compare the converter with currently recommended DACs; for established equipment, retaining AD565AKD/+ can minimize mechanical, firmware, and qualification changes. Confirm exact settling and output-buffer requirements before release.

🔧

Programmable Test and Calibration Systems

The AD565AKD/+ is appropriate for legacy automated test equipment that must synthesize calibration voltages or programmable stimuli. Its 12-bit resolution and one-channel output match common resistor-network or gain-stage architectures in which a digital code commands a precision voltage. The internal buried Zener reference is useful in measurement equipment because it avoids a separate discrete reference stage and preserves the intended AD565A signal-chain behavior. Place the converter output directly into the existing passive or active reconstruction network, and account for settling time whenever a test sequence changes the output rapidly. The device should be selected for maintenance of an existing 24-CDIP board rather than an unqualified new platform. Verify monotonicity, linearity, output compliance, and digital timing against the manufacturer datasheet.

🖥️

Legacy Data-Acquisition Analog Output

The AD565AKD/+ can provide the analog-output complement to a legacy data-acquisition system, allowing a digital controller to produce excitation, control, or compensation voltages alongside acquired data. The 12-bit monolithic DAC provides a compact converter function in the 24-CDIP package, and the buried Zener reference supports stable operation in systems designed around the AD565A family. It is particularly useful when the digital interface and board geometry cannot be changed, because retaining the established architecture limits both hardware rework and firmware validation. Ensure the output is reconstructed and buffered according to the original circuit; do not assume a generic 12-bit DAC output can directly drive a high-capacitance or bipolar load. Because this family is not recommended for new designs, use it primarily for continuity and modernization of installed systems.

📡

Precision Analog Signal Generation

The AD565AKD/+ is suitable for precision analog signal-generation blocks that need a 12-bit command interface, particularly in existing systems designed around Analog Devices AD565A converters. Its buried Zener reference has low-noise and long-term-stability characteristics intended to support accurate output generation without a separate discrete reference implementation. The output code can drive a passive reconstruction network, precision resistor ladder, or an existing output amplifier, depending on the required voltage range and load. Because the converter is single-channel, multi-channel systems require synchronized external multiplexing or separate converters. Verify monotonicity, differential and integral nonlinearity, output impedance, and settling time before selecting compensation or filter values. A currently recommended DAC may be preferable when the design is new rather than a lifecycle-maintenance project.

⚡

Legacy Control-System Spare Part

The AD565AKD/+ is especially relevant as a continuity part for control systems, analyzers, and industrial instruments already designed around the K-grade AD565A 24-CDIP converter. Retaining the same family and package can reduce risk when repairing an operating machine because analog calibration, control timing, and board layout remain unchanged. The single-channel 12-bit DAC can continue to generate the system command signal while the buried Zener reference maintains the intended reference behavior. When screening incoming stock, compare device markings, revision handling, and the exact suffix because a grade change may alter commercial-temperature suitability. Use the Request a Quote form for availability and include the original equipment part number when possible. Any substitute must pass a complete interface, temperature, and output-accuracy review before installation.

Сводка рекомендуемых товаров

What is the AD565AKD/+?
The AD565AKD/+ is a 12-bit, single-channel monolithic digital-to-analog converter from Analog Devices in a 24-CDIP package. It includes a buried Zener reference and is intended for analog output generation in legacy instrumentation, process-control, and test systems. According to the Analog Devices AD565A product page, the family uses a low-noise reference with long-term stability and temperature-drift characteristics comparable to discrete reference diodes.
Where can I download the AD565AKD/+ datasheet PDF?
The AD565AKD/+ documentation is available through the Analog Devices AD565A product page at https://www.analog.com/en/products/ad565a.html. Use the manufacturer datasheet for the authoritative pin assignments, electrical characteristics, timing tables, reference circuit, and recommended application details. The AD565AKD/+ belongs to the AD565A family, so identify every package-specific and grade-specific condition before applying the document to the exact suffix.
Is AD565AKD/+ suitable for a new design?
The AD565AKD/+ should generally not be selected for a new design because Analog Devices marks the AD565A family as not recommended for new designs. It remains relevant for repair, redesign, and lifecycle continuation of existing systems that already use the 12-bit DAC. For new analog-output platforms, evaluate a currently recommended converter and confirm whether circuit changes, software updates, and qualification work are justified.
Where to buy AD565AKD/+ online?
Use the Request a Quote form on this page to request AD565AKD/+ availability, lead time, and an order quotation. The form is the appropriate route for obtaining a device with the exact AD565AKD/+ suffix and 24-CDIP package. State the required quantity, date code, inspection requirements, and target price when submitting the request so sourcing can be matched to the legacy-device requirements.
What is the price of AD565AKD/+?
Submit the Request a Quote form on this page for a current AD565AKD/+ quotation. The structured listing price is intended for quick comparison, while the quote form accounts for quantity, date code, packaging, inspection, and current legacy-component availability. For an exact replacement, include the original manufacturer part number, 24-CDIP package, and any component markings shown on the device being replaced.
What is the lead time for AD565AKD/?
Request the current AD565AKD/+ lead time through the Request a Quote form on this page. Lead time for a not-recommended-for-new-designs device can vary with remaining inventory, assembly continuity, and order quantity. Include the target installation date and production schedule in the request. If uninterrupted supply is essential, ask whether an authorized transition path or an alternative currently supported converter is available.
Is AD565AKD/+ in stock?
Current AD565AKD/+ stock status should be confirmed through the Request a Quote form on this page because inventory for a legacy, not-recommended-for-new-designs DAC can change quickly. Provide the quantity and required inspection level with the request. If the exact suffix is unavailable, confirm whether an approved alternate manufacturer part number can be used before releasing a new production order.
What can replace the AD565AKD/+?
A valid replacement for the AD565AKD/+ must match the 24-CDIP footprint, 12-bit resolution, digital interface, reference arrangement, output range, and electrical limits. AD565AJD/+ is the closest identified same-family option, but its temperature grade differs and it should not be treated as automatically interchangeable. Use the manufacturer datasheet and an approved cross-reference review to confirm pin, timing, and operating-range compatibility before substitution.
What is the best drop-in replacement for AD565AKD/+?
No confirmed drop-in replacement can be identified from the available cross-reference information for the AD565AKD/+. The closest documented family candidate is AD565AJD/+, which uses a different temperature-grade suffix and requires review of operating-temperature limits and system qualification. Treat it as a conditional same-family candidate rather than an automatic drop-in replacement, and validate the complete interface and analog output performance before substitution.
AD565AKD/+ vs AD565AJD/+: which is better?
AD565AKD/+ is the preferred choice when the existing design requires the K-grade operating range, while AD565AJD/+ may fit only where the lower J-grade operating range is acceptable. Both belong to the 12-bit AD565A DAC family, and the distinction is not based on resolution or converter resolution. Confirm the exact temperature ranges, device markings, and qualification requirements in the Analog Devices datasheet before choosing.
When should I choose AD565AKD/+ over another DAC?
Choose the AD565AKD/+ when maintaining an existing 12-bit AD565A design that specifically requires the K-grade suffix and 24-CDIP footprint. Its internal buried Zener reference simplifies the reference arrangement compared with a converter requiring an external precision reference. For a new design, a currently recommended converter is generally more appropriate unless legacy continuity, qualification cost, or unchanged PCB constraints dominate the decision.
Is AD565AKD/+ suitable for industrial instrumentation?
The AD565AKD/+ can support suitable industrial instrumentation, especially in equipment designed around the AD565A family. Its 12-bit resolution, monolithic converter implementation, and buried Zener reference suit analog signal-generation requirements. Suitability still depends on the K-grade operating range, supply limits, accuracy, settling behavior, output loading, and system isolation, all of which must be checked against the manufacturer datasheet.
What are the key specifications of AD565AKD/+ that engineers should know?
The principal AD565AKD/+ identifiers are 12-bit resolution, one output channel, monolithic DAC construction, a buried Zener reference, and a 24-CDIP through-hole package. Analog Devices also identifies the AD565A family as not recommended for new designs. Exact voltage ranges, interface timing, settling time, linearity, noise, and temperature limits are the next parameters to verify in the manufacturer datasheet before schematic or firmware release.
Where is the AD565AKD/+ pinout and package diagram?
The AD565AKD/+ pinout is published in the Analog Devices AD565A family documentation and follows the 24-CDIP package used by the device. Begin with the Analog Devices product page at https://www.analog.com/en/products/ad565a.html and open the family datasheet. Use the pin-description and package-drawing tables for signal names, power connections, reference pins, and unused positions rather than inferring connections from a generic 24-pin DIP outline.
Does AD565AKD/+ meet RoHS and REACH requirements?
The RoHS and REACH status of the exact AD565AKD/+ ordering code should be confirmed from the current Analog Devices product documentation or a formal compliance declaration. Do not infer compliance solely because the converter is a legacy part, and do not transfer the declaration of a differently suffixed AD565A order code without checking the declared material scope. Request supporting documentation when an equipment manufacturer requires traceable compliance records.

Справочные инженерные данные для AD565AKD/+ — сравнение, рекомендации по проектированию и информация о соответствии.

Руководство по выбору

Choose the AD565AKD/+ when maintaining an existing AD565A-based system that requires the 24-CDIP package, 12-bit single-channel conversion, internal buried Zener reference, and K-grade operating class. It is the practical continuity choice for legacy industrial, test, and instrumentation equipment where board, firmware, and calibration changes would be costly. AD565AJD/+ is the closest identified family alternative, but the J-grade suffix requires a temperature-range review and may not be acceptable in all installations. Do not select either part solely from resolution or package; confirm pinout, digital timing, supply rails, reference behavior, output range, settling time, and load capability. For a new design, evaluate a currently recommended DAC because Analog Devices marks the AD565A family as not recommended for new designs.

Сравнение с аналогами

Параметр Этот товар AD565AJD/+
Brand Analog Devices Analog Devices
Package 24-CDIP 24-CDIP
Resolution 12 bit 12 bit
Number of Channels 1 channel 1 channel
Internal Reference Buried Zener reference Buried Zener reference
Temperature-Grade Suffix K grade J grade
Product Lifecycle Recommendation Not recommended for new designs Not recommended for new designs

Ключевые отличия

  • Uses the K-grade ordering suffix within the legacy AD565A family (против AD565AJD/+)
  • Combines a 12-bit single-channel monolithic DAC with a buried Zener reference (против AD565AJD/+)
  • Supports direct continuation of an existing 24-CDIP AD565A design (против AD565AJD/+)

Заметки по проектированию

Do not treat the J and K ordering suffixes as interchangeable without checking temperature requirements. The AD565AKD/+ and AD565AJD/+ share the AD565A converter family and 24-CDIP format, but the grade designation changes commercial-temperature suitability. For equipment operating outside the J-grade limits, retain the K-grade device or complete a formal thermal qualification. Also verify the complete pinout, digital timing, supply arrangement, and reference requirements rather than relying on resolution alone.

Preserve the established AD565A reference and analog-output layout when replacing the device in a working board. Keep the output reconstruction or smoothing network close to the converter, route the analog output away from switching-node and digital-clock traces, and maintain the original grounding strategy. Confirm whether the output requires passive loading, an active buffer, or DC offset correction. Unauthorized changes to reference or filtering networks can alter settling behavior and accuracy even when the converter code remains unchanged.

Check the converter's supply rails and reference bypass requirements directly from the manufacturer datasheet before inserting the AD565AKD/+. Ensure every supply remains within its specified operating range under startup, full-scale code transitions, and temperature extremes. Do not infer the reference voltage or output compliance from the internal buried Zener description alone. For a board already designed for AD565AKD/+, reproduce the original decoupling and grounding arrangement to avoid introducing supply transients that appear as analog-output errors.

Информация о соответствии

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Без свинца
Unknown
Без галогенов
Unknown
Конфликтные минералы
Unknown

Exact compliance declarations for AD565AKD/+ were not identified. AEC-Q100 is marked not applicable because this product is an industrial data-converter IC rather than an automotive-qualified device.

Данные проверены: 2026-11-22 — данные проверены и курируются командой компонентной инженерии XAIPART

Похожие запросы

AD565AKD/+ datasheet AD565AKD/+ pinout AD565AKD/+ datasheet pdf AD565AKD/+ replacement AD565AKD/+ equivalent AD565AKD/+ price AD565AKD/+ stock AD565AKD vs AD565AJD/+ AD565AKD 24-CDIP DAC Analog Devices AD565AKD/+ AD565AKD application circuit 12-bit DAC buried Zener reference

Связанные компоненты & термины

Analog Devices AD565AKD/+ AD565AKD AD565AJD/+ AD565A Digital-to-analog converter DAC Monolithic DAC Data converter Analog signal generation 12-bit resolution Single-channel DAC Buried Zener reference 24-CDIP Through-hole package Reconstruction filter Process control Laboratory instrumentation Test equipment Data acquisition Legacy system maintenance Output voltage Settling time Monotonicity Temperature-grade suffix
Быстрый запрос цены (RFQ)
Заполните все данные — наша команда продаж ответит в течение 24 часов
Артикул Производитель Корпус QTY Целевая цена Итого
✓
Запрос цены отправлен!

Мы ответим на ваш email в течение 24 часов

1
RFQ отправлен
2
Предложение получено
3
Заказ оформлен
4
Оплата
5
Отправлено
6
Доставлено
Просмотреть детали RFQ