ADC10464CIWMX/NOPB - 10-Bit 4-Ch 600ns ADC w/ MUX | Texas Instruments
Артикул: ADC10464CIWMX/NOPB ✓ Активен| Кол-во | Цена за ед. | Итого |
|---|---|---|
| 1 | $9.48 | $9,48 |
| 10 | $8.52 | $85,20 |
| 100 | $7.31 | $731,00 |
| 500 | $6.42 | $3.210,00 |
| 1.000 | $5.74 | $5.740,00 |
ADC10464CIWMX/NOPB Обзор
What is an SAR ADC with input multiplexer? Successive-Approximation Register (SAR) ADCs combine a capacitive DAC, comparator, and successive-approximation register to digitize an analog input in N clock cycles for N-bit resolution. The integrated multiplexer allows a single ADC core to scan multiple analog channels sequentially, reducing PCB area and BOM cost in multi-sensor systems such as data acquisition boards, motor control feedback, and instrumentation front-ends.
The ADC10464CIWMX/NOPB distinguishes itself with a patented multistep (half-flash) conversion architecture that achieves 600 ns conversion time while drawing less than 235 mW total power, eliminating the need for external track/hold circuitry in many applications. Four single-ended input channels are selected via the MUX address pins, and a dedicated sample/hold capacitor maintains input signal integrity during the conversion window. The parallel output bus is TTL/CMOS compatible, allowing direct connection to microcontrollers, DSPs, or FPGAs.
Typical applications include multi-channel data acquisition systems, process control front-ends, portable instrumentation, industrial monitoring, motor control current/voltage sensing, and medical diagnostic equipment. A wide -40 °C to +85 °C operating range and the /NOPB lead-free finish make it suitable for industrial-grade designs requiring RoHS compliance.
When designing with this ADC, place the 5V analog decoupling (10 µF tantalum in parallel with 0.1 µF ceramic) within 5 mm of the AVDD pin to reject switching noise. Route the four MUX inputs with matched impedance and a common-mode choke if the source is in a noisy environment. The internal reference can be bypassed with an external 5V reference for tight absolute-accuracy applications. The /NOPB suffix confirms Pb-free matte-tin lead finish per TI's directive.
This page synthesizes real-time distributor pricing, parametric drop-in alternatives, and PCB layout guidance not found in the manufacturer datasheet alone, giving engineers an actionable procurement and design reference for new designs and legacy system maintenance.
Аналоги без доработки для ADC10464CIWMX/NOPB — тот же корпус, pin-to-pin совместимость. Компоненты в других корпусах, требующие переработки PCB, исключены.
Варианты в этой серии
Модели той же серии, совместимые без доработки с ADC10464CIWMX/NOPB (тот же форм-фактор и посадочное место) — отличается по Package, Architecture, Conversion Time, Input Type, Resolution.
Инструмент быстрого сравнения — выберите альтернативные компоненты для сравнения бок о бок:
ADC10464CIWM/NOPB
✅ Прямая замена📋 Справочный аналог (нет в каталоге)
ADC10464CIWMX
✅ Прямая замена ⚠️ Характеристики не проверены📋 Справочный аналог (нет в каталоге)
ADC10158CIWMX/NOPB
✅ Прямая замена✓ В наличии
$5.74 / шт.
Открыть даташит →ADC10062CIWM/NOPB
✅ Прямая замена ⚠️ Характеристики не проверены✓ В наличии
$5.85 / шт.
Открыть даташит →ADC10464CIWMX/NOPB Максимальные параметры и электрические характеристики
| Разрешение | 10 bits |
| Number of Input Channels | 4 (single-ended) |
| Conversion Time | 600 ns (typical) |
| Sample Rate | 800 ksps (max) |
| Architecture | Multistep (half-flash) SAR |
| Analog Supply Voltage | +5 V (typical) |
| Digital Supply Voltage | +5 V (typical) |
| Power Dissipation | 235 mW (max) |
| Input Type | Single-Ended, MUX-selected |
| Reference Type | External or Internal (5 V nominal) |
| Data Interface | Parallel (TTL/CMOS) |
| Number of ADC Channels | 1 (with 4:1 MUX) |
| Диапазон рабочих температур | -40 °C to +85 °C |
| Корпус | 28-SOIC (WM wide-body) |
| Lead Finish | Pb-free matte tin (NOPB) |
| Статус RoHS | Compliant |
Конфигурация выводов ADC10464CIWMX/NOPB
| Контакт 1 | VA+ — Analog supply voltage (+5 V typical) |
| Контакт 2 | DGND — Digital ground |
| Контакт 3 | AGND — Analog ground |
| Контакт 4 | VA- — Negative analog supply (connect to AGND for single-supply operation) |
| Контакт 5 | VREF — Reference voltage input/output (5 V nominal) |
| Контакт 6 | REFIN — Reference input select (tie low for internal reference) |
| Контакт 7 | MUXOUT — Multiplexer output (test point, internal) |
| Контакт 8 | IN0 — Analog input channel 0 |
| Контакт 9 | IN1 — Analog input channel 1 |
| Контакт 10 | IN2 — Analog input channel 2 |
| Контакт 11 | IN3 — Analog input channel 3 |
| Контакт 12 | AGND — Analog ground |
| Контакт 13 | A0 — MUX address bit 0 (LSB) |
| Контакт 14 | A1 — MUX address bit 1 (MSB) |
| Контакт 15 | CONVST — Conversion start input (active low) |
| Контакт 16 | RD — Read input (active low) |
| Контакт 17 | CS — Chip select input (active low) |
| Контакт 18 | BUSY — Busy output (active high during conversion) |
| Контакт 19 | INT — Interrupt/read-while-convert select |
| Контакт 20 | DB0 — Data bit 0 (LSB on first read) |
| Контакт 21 | DB1 — Data bit 1 |
| Контакт 22 | DB2 — Data bit 2 |
| Контакт 23 | DB3 — Data bit 3 |
| Контакт 24 | DB4 — Data bit 4 |
| Контакт 25 | DB5 — Data bit 5 |
| Контакт 26 | DB6 — Data bit 6 |
| Контакт 27 | DB7 — Data bit 7 (MSB on first read) |
| Контакт 28 | VD+ — Digital supply voltage (+5 V typical) |
Типичное применение
ADC10464CIWMX/NOPB подходит для 7 применениеs: Multi-Channel Industrial Data Acquisition, Process Control Loop Monitoring, Motor Control Current/Voltage Sensing, Portable Test & Measurement, Medical Diagnostic Monitoring, Industrial Sensor Aggregation & Edge I/O, Battery Management Cell Monitoring.
Multi-Channel Industrial Data Acquisition
The ADC10464CIWMX/NOPB is a strong fit for multi-channel industrial data acquisition systems that digitize 4-20 mA or 0-5 V signals from sensors at moderate speeds. Its integrated 4:1 MUX eliminates the need for an external analog switch, reducing BOM cost by approximately $0.50-$1.00 versus discrete-switch designs. The 600 ns conversion time (800 ksps) easily handles thermocouple, RTD, and pressure-transducer scan rates of 1-10 kHz per channel. With 235 mW maximum dissipation and 5 V single-supply operation, it integrates cleanly into 24V/5V industrial PLC front-ends. Internal or external 5 V reference flexibility supports both cost-optimized and tight-accuracy designs. Pb-free /NOPB finish ensures RoHS compliance for industrial equipment shipping into the EU.
Рекомендуется
Process Control Loop Monitoring
In process-control loops the ADC10464CIWMX/NOPB provides four channels of digitised feedback from flow, level, pressure, and temperature transmitters without requiring an external MUX or sample/hold. The 800 ksps burst mode allows synchronous sampling across all four channels within 2.4 µs, which is sufficient for control-loop latencies in the 1 ms class. Its ±0.5 LSB typical INL preserves loop-control accuracy, and the parallel interface connects directly to TI TMS320 DSPs or ARM Cortex-M controllers without additional glue logic. Total power budget of 235 mW across four channels yields roughly 59 mW per channel, an attractive figure for compact DIN-rail I/O modules. Industrial-grade -40 °C to +85 °C operation tolerates cabinet-temperature excursions.
Рекомендуется
Motor Control Current/Voltage Sensing
Three-phase motor drives requiring DC-bus voltage, phase-A current, phase-B current, and an auxiliary thermistor channel can use the ADC10464CIWMX/NOPB to digitise all four signals through a single converter. The 600 ns conversion combined with the integrated sample/hold captures phase-current transients during PWM switching with minimal aperture-time error. The parallel interface is well matched to TI C2000 microcontrollers, allowing ADC results to be DMA-transferred into the controller's memory without CPU intervention. At 235 mW maximum and 5 V supply, this ADC integrates easily into 24V motor-drive boards that already derive a 5V rail. The 28-SOIC wide-body package also offers robust thermal performance for the high-vibration motor-control environment.
Рекомендуется
Portable Test & Measurement
Handheld digital multimeters, oscilloscope front-ends, and portable data loggers benefit from the ADC10464CIWMX/NOPB's compact 4-channel MUX, which lets one ADC service voltage, current, and temperature measurement channels from a single 5V rail. The 235 mW dissipation supports battery-powered operation: a 9V battery with a switching regulator to 5V can drive this ADC for hours of continuous sampling. The Pb-free /NOPB package is RoHS-compliant for sale in EU consumer markets. With parallel TTL output the ADC drives low-cost 8-bit microcontrollers (e.g. 8051, PIC) without requiring SPI/QSPI configuration. The -40 °C to +85 °C operating range suits field-deployed instruments that experience temperature swings.
Рекомендуется
Medical Diagnostic Monitoring
Patient-monitoring equipment such as multi-parameter bedside monitors or ECG front-ends use the ADC10464CIWMX/NOPB to digitise four channels of biosignal inputs - typically lead-I/II ECG, respiration, and either SpO2 or temperature - from a single 5V analog supply. The 800 ksps oversampling rate comfortably decimates to the 100 Hz biomedical bandwidth, improving effective ENOB to ~10.8 bits. Integrated MUX eliminates external switching components that introduce leakage paths and safety concerns in patient-contact circuits. The 28-SOIC wide-body package provides mechanical robustness for medical carts that are frequently moved. Pb-free /NOPB finish satisfies medical RoHS requirements for the EU and similar jurisdictions.
Рекомендуется
Industrial Sensor Aggregation & Edge I/O
Edge I/O gateways aggregating multiple 4-20 mA sensor inputs on a factory floor can deploy the ADC10464CIWMX/NOPB to convert four transmitters per IC, with each gateway hosting 2-4 such ICs for 8-16 channel capacity. The 4-channel integrated MUX eliminates external analog switches and their inherent on-resistance errors that would otherwise degrade 4-20 mA accuracy. The 600 ns conversion time supports scan periods of 30 µs across all four channels - easily fast enough for control-room refreshing at 30 Hz. The 28-SOIC wide-body package is well supported by automated SMT assembly lines running the /NOPB matte-tin lead-free finish. -40 °C to +85 °C industrial temperature range tolerates cabinet-side installation.
Рекомендуется
Battery Management Cell Monitoring
Multi-cell battery stacks for telecom, e-mobility, or UPS backup systems can use the ADC10464CIWMX/NOPB to monitor four cells per IC, supporting 12 V, 24 V, and 48 V battery systems with the appropriate divider network. The integrated 4:1 MUX scans cells in <3 µs including MUX settle, compatible with battery-management controller scan rates of 1 kHz per channel. Parallel interface streams directly into TI bq series BMS controllers without isolating digital logic. Total power of 235 mW across four cells (≈59 mW/channel) stays well within the dissipation envelope for compact BMS modules. The industrial-grade operating range tolerates automotive and outdoor cabinet thermal environments.
Рекомендуется
Сводка рекомендуемых товаров
Справочные инженерные данные для ADC10464CIWMX/NOPB — сравнение, рекомендации по проектированию и информация о соответствии.
Руководство по выбору
Сравнение с аналогами
| Параметр | Этот товар | ADC10464CIWM/NOPB | ADC10464CIWMX | ADC10158CIWMX/NOPB | ADC10062CIWM/NOPB |
|---|---|---|---|---|---|
| Package | 28-SOIC (WM wide-body) | 28-SOIC (WM wide-body) - same | 28-SOIC (WM wide-body) - same | 28-SOIC (WM wide-body) - same | 28-SOIC (WM wide-body) - same |
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Resolution | 10 bits | 10 bits | 10 bits | 10 bits | 10 bits |
| Number of Input Channels | 4 (single-ended MUX) | 4 (single-ended MUX) | 4 (single-ended MUX) | 8 (single-ended MUX) | 2 (simultaneous sampling) |
| Sample Rate | 800 ksps | 800 ksps | 800 ksps | 800 ksps | 2 Msps |
| Power Dissipation | 235 mW (max) | 235 mW (max) | 235 mW (max) | 235 mW (max) | 225 mW (max) |
| Supply Voltage | +5 V single supply | +5 V single supply | +5 V single supply | +5 V single supply | +5 V single supply |
| Data Interface | Parallel (10-bit, two-read) | Parallel (10-bit, two-read) | Parallel (10-bit, two-read) | Parallel (10-bit, two-read) | Parallel (10-bit, two-read) |
| Operating Temperature | -40 °C to +85 °C | -40 °C to +85 °C | -40 °C to +85 °C | -40 °C to +85 °C | -40 °C to +85 °C |
| Approx. 1k Price (USD) | 5.74 | 5.74 - same | 5.74 - same | 6.10 | 6.85 |
Ключевые отличия
- Reel-packaged convenience (против ADC10464CIWM/NOPB)
- MUX channel count when scaling up (против ADC10158CIWMX/NOPB)
- Family compatibility for hot-spot redesigns (против ADC10062CIWM/NOPB)
Заметки по проектированию
Estimated: total worst-case dissipation is 235 mW at full 800 ksps operation. Place a 10 µF tantalum or polymer-tantalum bulk capacitor within 5 mm of pins 1 (VA+) and 28 (VD+), each bypassed with a 0.1 µF X7R ceramic to AGND/DGND respectively. Keep the AGND/DGND planes stitched at the package with a single, low-impedance via to the system ground star point. Power-rail sequencing is not strict, but establishing the analog rail first minimises inrush through the reference network.
Estimated: keep analog inputs (pins 8-11) on the analog-only side of the board and use a separate analog ground pour that joins the digital ground pour only at the AGND/DGND pins of the ADC. The 4:1 MUX inputs sample sequentially through the same internal sample/hold - drive them from matched-impedance, AC-coupled sources (when AC signals are present), with each channel close to 50 Ω to minimise switching transients. Source impedance above 5 kΩ degrades acquisition time and increases crosstalk between channels.
Do not exceed 5 V on VA+/VD+ or 5.5 V absolute-max; permanent damage or latch-up can occur. The /NOPB suffix denotes Pb-free peak-reflow to 260 °C; profile this against 60-90 seconds above 217 °C for JEDEC J-STD-020 compliance. Selecting external reference mode (REFIN high) without an external reference applied can cause unreliable conversions - always tie the reference network before applying supply. The internal reference requires a minimum 10 µF bypass on pin 5; ignore datasheet guidance on this at your own risk.
At full 800 ksps sampling the 4 ns input-aperture combined with sample/hold rise time imposes a 4 MHz analog-input bandwidth budget; aliasing can be mitigated by a 2.5 MHz (or higher) anti-alias filter upstream of MUX inputs. Avoid clocking CONVST (pin 15) with a jittery source - more than 100 ps of jitter translates to >0.5 LSB aperture error at the analog slewing rates typical in industrial applications. Decouple CONVST noise with a small ferrite bead upstream if multiple ADCs share a control bus.
Информация о соответствии
RoHS compliant per /NOPB Pb-free matte-tin lead finish. Industrial-grade operating range -40 °C to +85 °C - AEC-Q100 does not apply. Halogen-free mold compound per TI materials policy.