ADM3052BRWZ - Isolated CAN Transceiver with Regulator | Analog Devices
Артикул: ADM3052BRWZ ✓ Активен| Кол-во | Цена за ед. | Итого |
|---|---|---|
| 1 | $6.5 | $6,50 |
| 10 | $5.85 | $58,50 |
| 100 | $5.2 | $520,00 |
| 500 | $4.68 | $2.340,00 |
| 1.000 | $4.96 | $4.960,00 |
ADM3052BRWZ Обзор
An isolated CAN transceiver is a component that provides galvanic isolation between the CAN protocol controller and the physical bus, protecting the logic side from high common-mode voltages, ground loops, and electrical noise. It integrates a digital isolator, a CAN transceiver, and often a DC-DC converter or regulator to power the isolated side. In the hierarchy of CAN interface components, it sits above a standard transceiver by adding isolation, which is critical in industrial, automotive, and building automation systems where long bus lengths and differing ground potentials are common.
Key features include a 5 kVrms isolation rating, a bus-side linear regulator with 5V output, and compliance with ISO 11898-2. The device offers a common-mode voltage range of -12V to +12V and a common-mode transient immunity of 25 kV/µs, ensuring robust operation in noisy environments. It also features thermal shutdown protection and a logic-side supply range of 3.0V to 5.5V, making it versatile for various controller interfaces.
Technically, the ADM3052 integrates a 3-channel iCoupler digital isolator for the TXD, RXD, and a control signal, eliminating the need for a separate isolation barrier. The integrated linear regulator simplifies power supply design by generating the isolated 5V bus supply from a higher input voltage, reducing component count and board space. The device is specified for the industrial temperature range of -40°C to +85°C and is available in a 16-lead SOIC-W package.
Typical applications include industrial fieldbus networks, building automation systems, automotive diagnostics, and any CAN bus requiring galvanic isolation. The integrated regulator is particularly useful in systems where a 24V supply is available, as it can directly power the bus side without an external DC-DC converter.
When designing with the ADM3052, ensure proper PCB layout with adequate creepage and clearance for the isolation barrier, and place decoupling capacitors close to the VCC and V+ pins. The bus-side regulator requires an output capacitor for stability, and the input voltage must not exceed the absolute maximum rating of 27V.
Аналоги без доработки для ADM3052BRWZ — тот же корпус, pin-to-pin совместимость. Компоненты в других корпусах, требующие переработки PCB, исключены.
Варианты в этой серии
Модели той же серии, совместимые без доработки с ADM3052BRWZ (тот же форм-фактор и посадочное место) — отличается по Package, Data Rate, Isolation Voltage, Operating Temperature Range, Protocol.
Инструмент быстрого сравнения — выберите альтернативные компоненты для сравнения бок о бок:
ADM3052BRWZ-REEL7
✅ Прямая замена📋 Справочный аналог (нет в каталоге)
ADM3053BRWZ
✅ Прямая замена ⚠️ Характеристики не проверены✓ В наличии
$3.8 / шт.
Открыть даташит →ADM3051BRWZ
✅ Прямая замена ⚠️ Характеристики не проверены✓ В наличии
$1.6 / шт.
Открыть даташит →ISO1050DW
✅ Прямая замена ⚠️ Характеристики не проверены📋 Справочный аналог (нет в каталоге)
ADM3054BRWZ
✅ Прямая замена ⚠️ Характеристики не проверены✓ В наличии
$3.1 / шт.
Открыть даташит →ADM3052BRWZ Характеристики
| Type | Isolated CAN Transceiver |
| Number of Drivers | 1 |
| Number of Receivers | 1 |
| Скорость передачи данных | 1 Mbps |
| Isolation Voltage | 5 kVrms |
| Logic Supply Voltage | 3.0 V to 5.5 V |
| Bus-Side Regulator Input | 5 V to 27 V |
| Regulated Output Voltage | 5 V |
| Common-Mode Voltage Range | -12 V to +12 V |
| Common-Mode Transient Immunity | 25 kV/µs |
| Диапазон рабочих температур | -40°C to +85°C |
| Корпус | 16-Lead SOIC-W |
| Тип монтажа | Surface Mount |
| Статус RoHS | Compliant |
| Standards | ISO 11898-2 |
Конфигурация выводов ADM3052BRWZ
| Контакт 1 | VCC — Logic supply voltage (3.0V to 5.5V) |
| Контакт 2 | GND — Logic ground |
| Контакт 3 | TXD — Transmit data input |
| Контакт 4 | RXD — Receive data output |
| Контакт 5 | V+ — Bus-side regulator input (5V to 27V) |
| Контакт 6 | VOUT — Regulated 5V output for bus side |
| Контакт 7 | GNDBUS — Bus-side ground |
| Контакт 8 | CANH — CAN high bus line |
| Контакт 9 | CANL — CAN low bus line |
| Контакт 10 | GNDBUS — Bus-side ground |
| Контакт 11 | NC — No connect |
| Контакт 12 | NC — No connect |
| Контакт 13 | NC — No connect |
| Контакт 14 | NC — No connect |
| Контакт 15 | NC — No connect |
| Контакт 16 | NC — No connect |
Типичное применение
ADM3052BRWZ подходит для 6 применениеs: Industrial Fieldbus Networks, Building Automation Systems, Automotive Diagnostics, Medical Equipment, Renewable Energy Systems, Transportation and Rail.
Industrial Fieldbus Networks
The ADM3052BRWZ provides galvanic isolation and robust communication for industrial CAN networks. Its 5 kVrms isolation protects logic-side controllers from ground loops and high common-mode voltages common in factory automation. The integrated linear regulator simplifies power supply design by accepting 24V bus supplies and generating a regulated 5V for the bus side, reducing component count. With 1 Mbps data rate and -40°C to +85°C operation, it suits harsh industrial environments.
Рекомендуется
Building Automation Systems
In building automation, the ADM3052BRWZ enables reliable CAN communication between HVAC controllers, lighting systems, and security panels. The isolation barrier prevents ground potential differences between floors and equipment from disrupting data. The integrated regulator allows direct connection to 24V building power, eliminating separate DC-DC converters. Its compact SOIC-W package fits space-constrained control modules, and the 5 kVrms isolation meets safety requirements for equipment connected across different power domains.
Рекомендуется
Automotive Diagnostics
The ADM3052BRWZ is used in automotive diagnostic systems for CAN communication between ECUs and test equipment. Its isolation protects diagnostic tools from high common-mode voltages in vehicle electrical systems. The integrated regulator simplifies powering the bus side from the vehicle's 12V or 24V supply. With 1 Mbps data rate and robust transient immunity of 25 kV/µs, it ensures reliable communication in electrically noisy automotive environments. The -40°C to +85°C range covers under-hood and in-cabin temperature extremes.
Рекомендуется
Medical Equipment
The ADM3052BRWZ provides isolated CAN communication in medical devices such as patient monitors and imaging systems. The 5 kVrms isolation ensures patient safety by separating low-voltage control circuits from high-voltage power sections. The integrated regulator reduces board space and simplifies power design, which is critical in compact medical devices. Its low EMI and robust transient immunity help meet medical EMC standards. The wide temperature range and high reliability make it suitable for continuous operation in clinical environments.
Рекомендуется
Renewable Energy Systems
In solar inverters and wind turbines, the ADM3052BRWZ enables isolated CAN communication between power stages and control units. The isolation barrier protects low-voltage controllers from high-voltage DC buses and switching noise. The integrated linear regulator accepts the 24V auxiliary supply and generates a clean 5V for the bus side, eliminating external regulators. With 5 kVrms isolation and 25 kV/µs transient immunity, it withstands the harsh EMI environment of power electronics. Its industrial temperature range ensures reliable operation outdoors.
Рекомендуется
Transportation and Rail
The ADM3052BRWZ is used in railway and transportation systems for CAN communication between traction control, braking, and passenger information systems. Its 5 kVrms isolation provides safety isolation between different voltage domains, meeting railway standards. The integrated regulator simplifies powering the bus side from the train's 24V or 110V supply. With 1 Mbps data rate and robust transient immunity, it ensures reliable communication in the electrically noisy railway environment. The -40°C to +85°C range covers extreme outdoor conditions.
Рекомендуется
Сводка рекомендуемых товаров
Справочные инженерные данные для ADM3052BRWZ — сравнение, рекомендации по проектированию и информация о соответствии.
Руководство по выбору
Сравнение с аналогами
| Параметр | Этот товар | ADM3052BRWZ-REEL7 | ADM3053BRWZ | ADM3051BRWZ | ISO1050DW |
|---|---|---|---|---|---|
| Package | 16-Lead SOIC-W | 16-Lead SOIC-W | 16-Lead SOIC-W | 16-Lead SOIC-W | 16-Lead SOIC-W |
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Texas Instruments |
| Isolation | 5 kVrms | 5 kVrms | 5 kVrms | None | 5 kVrms |
| Integrated Regulator | Linear Regulator | Linear Regulator | DC-DC Converter | None | None |
| Data Rate | 1 Mbps | 1 Mbps | 1 Mbps | 1 Mbps | 1 Mbps |
| Logic Supply Voltage | 3.0V to 5.5V | 3.0V to 5.5V | 3.0V to 5.5V | 3.0V to 5.5V | 3.0V to 5.5V |
| Bus-Side Input Voltage | 5V to 27V | 5V to 27V | 5V to 27V | N/A | N/A |
| Common-Mode Transient Immunity | 25 kV/µs | 25 kV/µs | 25 kV/µs | N/A | 100 kV/µs |
Ключевые отличия
- Integrated linear regulator simplifies power design (против ISO1050DW)
- Higher isolation voltage than non-isolated alternatives (против ADM3051BRWZ)
- Lower cost and lower EMI than ADM3053 (против ADM3053BRWZ)
Заметки по проектированию
For the ADM3052BRWZ, maintain proper creepage and clearance distances under the SOIC-W package to achieve the 5 kVrms isolation rating. Use a PCB with at least 8 mm creepage between the logic and bus sides. Place a 100 nF decoupling capacitor close to VCC and a 10 µF capacitor on VOUT for regulator stability. Ensure the ground planes are separated under the isolation barrier.
The integrated linear regulator dissipates power as (V+ - VOUT) * IOUT. For example, with V+ = 24V and IOUT = 100 mA, dissipation is 1.9W, which may require thermal relief. Ensure the SOIC-W package has adequate copper area for heat sinking. If higher efficiency is needed, consider the ADM3053 with a DC-DC converter.
Do not exceed the absolute maximum input voltage of 27V on the V+ pin. The bus-side regulator output VOUT must be bypassed with a capacitor (e.g., 10 µF) to prevent oscillation. Also, ensure the logic supply VCC is within 3.0V to 5.5V; operating outside this range can cause communication errors. Refer to the datasheet for the recommended application circuit.
Информация о соответствии
RoHS compliant per Analog Devices product page. Not AEC-Q100 qualified. Lead-free per datasheet.