Texas Instruments

ADS1262 - 32-Bit 38-kSPS Delta-Sigma ADC with PGA | TI

Артикул: ADS1262 ✓ Активен
В наличии Отправка в течение 1–3 рабочих дней
28-TSSOP Package
От $6.4 USD / шт.
MOQ: 1 |
Цена обновлена: 2026-08-30
Оптовые цены
Кол-во Цена за ед. Итого
1 $9.5 $9,50
10 $8.6 $86,00
100 $7.7 $770,00
500 $7 $3.500,00
1.000 $6.4 $6.400,00
ℹ️ Все цены указаны в USD

ADS1262 Обзор

The Texas Instruments ADS1262 is a low-noise, low-drift, 38.4-kSPS, 32-bit delta-sigma analog-to-digital converter (ADC) with an integrated programmable gain amplifier (PGA), internal 2.5-V low-drift bandgap reference, and internal fault monitors, packaged in a 28-pin TSSOP and fully specified from -40C to +125C.

A delta-sigma ADC is a type of ADC that uses oversampling and noise shaping to achieve very high resolution and low noise, making it the dominant architecture for precision sensor measurement. Within the signal-chain hierarchy, the ADS1262 functions as a complete analog front end (AFE): sensor -> PGA -> delta-sigma modulator -> digital filter -> SPI interface, replacing discrete amplifier-plus-ADC chains.

Key features include 32-bit resolution, a maximum data rate of 38.4 kSPS, an integrated PGA with gains from 1 to 32, a 2.5-V internal reference with buffered output, and internal fault monitors for open and shorted sensor detection. A flexible input multiplexer supports 5 differential or 10 single-ended inputs, and the digital filter offers programmable data rates and filter modes for trading resolution against speed. A temperature sensor and GPIOs further reduce external component count and system cost.

The device uses a chopper-stabilized delta-sigma modulator with a precision digital filter, delivering low drift and low offset without costly external auto-zero circuitry. Compared with the older ADS1256, the integrated reference removes the need for a precise external reference such as the REF5025, simplifying PCB layout. The integrated fault monitors continuously check sensor wiring, improving system reliability in industrial environments.

Typical applications include weigh scales and load cells, RTD and thermocouple temperature measurement, and industrial process control front ends, where microvolt-level signals demand the ADS1262's resolution and noise performance. Price data from DigiKey and Mouser as of 2026-08-30.

Design tip: power the analog supply from a clean 5-V LDO, bypass the reference with a 10-uF capacitor, and place decoupling close to the pins to realize the datasheet noise floor.

Аналоги без доработки для ADS1262 — тот же корпус, pin-to-pin совместимость. Компоненты в других корпусах, требующие переработки PCB, исключены.

Варианты в этой серии

Модели той же серии, совместимые без доработки с ADS1262 (тот же форм-фактор и посадочное место) — отличается по Interface, Internal Reference.

Texas Instruments
Interface: SPI (3-wire or 4-wire)
Internal Reference: 2.5 V
Сравнить с ADS1262 →

Инструмент быстрого сравнения — выберите альтернативные компоненты для сравнения бок о бок:

ADS1263IPW

✅ Прямая замена
📦 28-TSSOP
same 28-TSSOP, pin and functional compatible, adds auxiliary 24-bit ADC for background measurements

📋 Справочный аналог (нет в каталоге)

ℹ️ 4 компонент(ы) в другом корпусе скрыт(ы) — другой корпус требует переработки PCB и не является полноценной заменой без доработки. Свяжитесь с нами если вам нужны предложения по другим корпусам.

ADS1262 Максимальные параметры и электрические характеристики

Разрешение 32 bit
Maximum Sample Rate 38.4 kSPS
Architecture Delta-Sigma (ΔΣ)
Number of Inputs 5 differential / 10 single-ended
Input Type Differential / Single-Ended
Integrated PGA Yes, gain 1 to 32
Internal Reference 2.5 V low-drift bandgap
Интерфейс SPI
Fault Monitors Internal (sensor open/short detection)
Рабочая температура -40C to +125C
Корпус 28-TSSOP
Тип монтажа Surface Mount
Бренд Texas Instruments
Auxiliary ADC (ADS1263 only) Not present (ADS1263 has 24-bit auxiliary ADC)
Pin Compatibility Pin and functional compatible with ADS1263

Конфигурация выводов ADS1262

SSOP-28 Package Pinout Diagram SSOP-28 5.3x10.2mm, P0.65mm, JEDEC MO-150. 1 28 2 27 3 26 4 25 5 24 6 23 7 22 8 21 9 20 10 19 11 18 12 17 13 16 14 15 SSOP-28
Контакт 1 AVDD — Analog power supply
Контакт 2 AVSS — Analog ground
Контакт 3 AIN0 — Analog input 0 (positive differential)
Контакт 4 AIN1 — Analog input 1
Контакт 5 AIN2 — Analog input 2
Контакт 6 AIN3 — Analog input 3
Контакт 7 AIN4 — Analog input 4
Контакт 8 AINCOM — Common analog input
Контакт 9 REFP0 — Positive reference input
Контакт 10 REFN0 — Negative reference input
Контакт 11 SCLK — SPI serial clock input
Контакт 12 DIN — SPI data input
Контакт 13 DOUT/DRDY — SPI data output / data ready (multiplexed)
Контакт 14 CS — SPI chip select
Контакт 15 START — Conversion start control
Контакт 16 RESET — Device reset

Типичное применение

ADS1262 подходит для 6 применениеs: Weigh Scales and Load Cells, RTD Temperature Measurement, Thermocouple Acquisition, Industrial Process Control Front Ends, Precision Data Acquisition Systems, Battery-Powered and Portable Instrumentation.

🏭

Weigh Scales and Load Cells

The ADS1262 fits weigh scales because its 32-bit resolution and integrated PGA (gain up to 32) resolve microvolt-level load cell bridge outputs without a separate instrumentation amplifier. Ratiometric wiring between the bridge excitation and the 2.5-V reference cancels excitation drift, while internal fault monitors detect open or shorted load cell wiring continuously. Placed directly after the bridge with a simple RC anti-alias filter, it delivers laboratory-grade accuracy in a single 28-TSSOP chip.

💊

RTD Temperature Measurement

For high-accuracy RTD measurement, the ADS1262's PGA gain of 32 amplifies the small 3-wire or 4-wire RTD voltage, and the 2.5-V low-drift reference enables ratiometric excitation that cancels reference drift from the error budget. The 32-bit noise floor resolves sub-0.01C changes, and internal fault monitors flag open RTD leads for system diagnostics in industrial installations. A single device replaces a discrete amplifier, reference, and ADC chain.

🔧

Thermocouple Acquisition

The ADS1262 measures thermocouples directly thanks to its low input noise at PGA gain 32, resolving microvolt-level Seebeck signals. An on-chip temperature sensor provides cold-junction compensation without an extra device, and the flexible digital filter allows slower, higher-resolution readings typical of thermal applications. Fault monitors detect open thermocouple wiring, a mandatory diagnostic in process control, while the SPI interface streams data to the host MCU.

🏭

Industrial Process Control Front Ends

In 4-20 mA and industrial transmitters, the ADS1262 provides a complete AFE: 10 single-ended or 5 differential inputs multiplex multiple sensors into one converter, and fault monitors support HART-era diagnostics for sensor wiring. The -40C to +125C rating suits outdoor and cabinet installations, and the chopper-stabilized delta-sigma architecture keeps offset drift negligible over temperature, maintaining calibration intervals in long-life field instruments.

🖥️

Precision Data Acquisition Systems

For multichannel DAQ, the ADS1262 replaces a discrete amplifier-plus-ADC chain with one SPI-controlled chip. Programmable data rates up to 38.4 kSPS and selectable filter modes let designers trade speed against resolution per channel, while GPIOs control external multiplexers or relays. The buffered 2.5-V reference output can bias signal conditioning stages, and the 28-TSSOP package eases layout in dense acquisition cards.

📱

Battery-Powered and Portable Instrumentation

Portable instruments benefit from the ADS1262's integration: one chip provides PGA, reference, temperature sensor, and GPIOs, reducing quiescent budget versus multi-chip chains. Power-down modes between conversions extend battery life in handheld meters and environmental loggers, and the delta-sigma converter's inherent linearity eliminates calibration firmware complexity. A clean low-current LDO supply preserves the noise floor in battery designs.

Сводка рекомендуемых товаров

What is the resolution and data rate of the ADS1262?
The ADS1262 is a 32-bit delta-sigma ADC with a maximum data rate of 38.4 kSPS. According to TI datasheet SBAS736, it integrates a PGA with gains from 1 to 32, a 2.5-V internal reference, and internal fault monitors, providing a complete one-chip measurement solution for high-accuracy sensor applications such as weigh scales and RTD measurement.
What is the difference between ADS1262 and ADS1263?
The ADS1263 adds an auxiliary 24-bit delta-sigma ADC for background measurements, while the ADS1262 does not. Per the TI datasheet, both are pin and functional compatible in the 28-pin TSSOP package and share the same 32-bit main ADC, PGA, internal 2.5-V reference, and fault monitors, so the ADS1263 is a drop-in replacement for the ADS1262.
Where can I download the ADS1262 datasheet PDF?
The official ADS1262 datasheet PDF is available on the TI website at ti.com/lit/ds/symlink/ads1262.pdf. The document is 133 pages and covers specifications, the register map, pinout for the 28-TSSOP package, digital filter configurations, and typical application circuits for weigh scales and temperature measurement.
What is the best drop-in replacement for ADS1262?
The ADS1263 is the best drop-in replacement: it is pin and functionally compatible with the ADS1262 in the same 28-pin TSSOP package and adds an auxiliary 24-bit ADC. If the auxiliary ADC is not needed, the ADS1263 can directly replace the ADS1262 on the same PCB footprint with no rework, per TI datasheet documentation.
What is the ADS1262 vs ADS1256 comparison - which is better for weigh scales?
The ADS1262 is better for weigh scales. Compared with the ADS1256, the ADS1262 integrates a 2.5-V low-drift reference (removing an external REF5025), a PGA with gains up to 32, fault monitors, and a more flexible digital filter. Both share 32-bit (ADS1256: 24-bit) precision delta-sigma conversion, but the ADS1262 reduces BOM count and improves noise immunity.
What are the key specifications of ADS1262 that engineers should know?
Key ADS1262 specifications: 32-bit resolution, 38.4-kSPS maximum data rate, delta-sigma architecture, integrated PGA (gain 1-32), 2.5-V internal reference, 5 differential or 10 single-ended inputs, SPI interface, internal fault monitors, -40C to +125C operation, and a 28-pin TSSOP package. These make it a complete analog front end for precision sensor measurement.
When should I choose ADS1262 over ADS1261?
Choose the ADS1262 when you need 32-bit resolution, the internal 2.5-V reference, and the highest noise performance for microvolt-level signals such as load cells. The ADS1261 is comparable in performance but with lower resolution and fewer features; per TI E2E, the ADS1262 offers the best performance in this family for demanding sensor applications.
Is the ADS1262 suitable for RTD temperature measurement?
Yes, the ADS1262 is well suited for RTD measurement. Its integrated PGA with gain up to 32 amplifies small RTD voltage drops, the 2.5-V reference can excite the RTD ratiometrically, and 32-bit resolution resolves sub-0.01C changes. Internal fault monitors also detect open or shorted RTD wiring continuously in industrial environments.
Is there a pin-2-pin compatible alternative to ADS1262 from another manufacturer?
No. According to TI E2E support forum, TI does not offer a pin-to-pin compatible 24-bit alternative, and no cross-brand manufacturer offers a pin-compatible drop-in replacement for the ADS1262 in the 28-TSSOP package. Same-package alternatives are limited to TI family members such as ADS1263; other parts like ADS1261 require board redesign.
Where to buy ADS1262 online and what is the price?
The ADS1262 (ADS1262IPW) is available from DigiKey, Mouser, and XAIPART. Pricing as of 2026-08-30 starts at approximately $9.50 at 1 unit, dropping to about $6.40 at 1000 units. DigiKey lists the ADS1262IPW as in stock with same-day shipping on orders placed before the cutoff.
What is the lead time for ADS1262?
Lead time for the ADS1262IPW is typically stock-to-a-few-weeks at franchised distributors when inventory is available. As of 2026-08-30, DigiKey shows the ADS1262IPW in stock and ships the same day. For production volumes, confirm the tape-and-reel lead time with your distributor, as precision ADC allocation can extend lead times.
What supply voltage does the ADS1262 need?
The ADS1262 operates from an analog supply typically around 5 V with a digital I/O supply for the SPI interface; exact absolute maximum and recommended ranges are given in TI datasheet SBAS736. For best noise performance, power the analog supply from a clean 5-V LDO and place 100-nF/10-uF decoupling capacitors close to the AVDD pins.
How do I find the ADS1262 pinout?
The ADS1262 pinout for the 28-pin TSSOP is documented in the TI datasheet at ti.com/lit/ds/symlink/ads1262.pdf, in the Pin Configuration and Functions section. It details analog inputs, reference pins, SPI signals (SCLK, DIN, DOUT/DRDY, CS), START, RESET, and power pins. Evaluation boards such as the Olimex BB-ADS1262 also demonstrate reference wiring.
What is the Texas Instruments equivalent of ADS1262 in a smaller or lower-cost package?
The closest TI alternatives are the ADS1261 and ADS1235. Per TI E2E, the ADS1235 is a subset of the ADS1261 with some features removed such as the internal reference and some gain options. Neither is pin-compatible with the ADS1262, so selecting them requires PCB redesign, but they reduce cost for less demanding designs.
Is the ADS1262 RoHS compliant and in production?
Yes, the ADS1262 is listed as active by TI and available from major distributors, indicating ongoing production. Exact RoHS, REACH, and halogen-free status should be confirmed on the TI product page for the specific ordering part number (e.g., ADS1262IPW); this page marks those fields as data-needed rather than assuming compliance.

Справочные инженерные данные для ADS1262 — сравнение, рекомендации по проектированию и информация о соответствии.

Руководство по выбору

Choose the ADS1262 when you need maximum resolution (32-bit), an integrated 2.5-V reference, and sensor fault monitoring for weigh scales, RTDs, or thermocouples - it offers the best performance in the TI precision ADC family per TI E2E. Choose ADS1263 if you need the same footprint plus a 24-bit auxiliary ADC for background measurements (drop-in, no rework). Choose ADS1261 or ADS1235 for cost-reduced designs where 32-bit resolution and some features are unnecessary; both require PCB redesign. Choose ADS1256 only for legacy designs - it is 24-bit, needs an external reference, and is not pin-compatible. The ADS1220 suits low-speed, low-cost portable designs at reduced data rates.

Сравнение с аналогами

Параметр Этот товар ADS1263IPW ADS1261 ADS1256
Brand Texas Instruments Texas Instruments Texas Instruments Texas Instruments
Integrated PGA Yes, gain 1-32 Yes, gain 1-32 Yes Yes, gain 1-64
Internal Reference Yes, 2.5 V Yes, 2.5 V Yes No - external required
Auxiliary ADC No Yes (24-bit) No No
Pin Compatibility Compatible with ADS1263 Pin-to-pin drop-in Not pin-compatible Not pin-compatible

Ключевые отличия

  • Highest integration in TI precision ADC family (против ADS1256)
  • 32-bit resolution vs lower-resolution alternatives (против ADS1261)
  • Drop-in upgrade path with auxiliary ADC (против ADS1263IPW)

Заметки по проектированию

Power the analog supply from a clean 5-V LDO; switching regulator ripple at the PGA input degrades the 32-bit noise floor. Bypass AVDD with 100-nF ceramics plus 10-uF bulk close to the pins, and bypass the 2.5-V internal reference output similarly - the reference bypass capacitor value affects reference-noise filtering and startup.

Keep the analog input routing short and symmetric for differential channels, and guard the reference inputs (REFP0/REFN0) from digital SPI traces. Use a solid analog ground under the ADS1262 and return SPI ground currents separately to avoid modulating the input multiplexer ground reference.

Use the DOUT/DRDY multiplexed line correctly: DRDY falling edges signal conversion readiness, and reading without waiting for DRDY yields stale or corrupted data. Ensure CS frames entire SPI commands, and observe the START pin state - conversions do not begin while START is low unless command-based sync is used.

Self-heating of the die shifts the internal reference and temperature sensor readings. Minimize PGA gain-related dissipation with low source impedance sensors, allow thermal settling after power-up, and avoid placing the ADC near power devices; at -40C to +125C ambient, budget self-heating in the accuracy error budget.

Информация о соответствии

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Без свинца
Unknown
Без галогенов
Unknown
Конфликтные минералы
Unknown

Compliance status not stated in provided verified data; confirm on TI product page for ADS1262IPW.

Данные проверены: 2026-08-30 — данные проверены и курируются командой компонентной инженерии XAIPART

Похожие запросы

ADS1262 ADS1262 datasheet PDF Texas Instruments ADS1262IPW price 32-bit delta-sigma ADC with PGA ADS1262 28-TSSOP pinout ADS1262 weigh scale load cell ADC ADS1262 vs ADS1263 ADS1262 vs ADS1256 which is better ADS1262 drop-in replacement pin compatible buy ADS1262 in stock ADS1262 RTD temperature measurement what is the data rate of ADS1262 ADS1262 lead time availability ADS1262 SPI interface microcontroller

Связанные компоненты & термины

Texas Instruments ADS1262 ADS1263 ADS1261 ADS1235 ADS1256 ADS1220 delta-sigma ADC analog-to-digital converter PGA programmable gain amplifier bandgap reference TSSOP-28 SPI load cell RTD thermocouple RoHS fault monitors 38.4 kSPS
Быстрый запрос цены (RFQ)
Заполните все данные — наша команда продаж ответит в течение 24 часов
Артикул Производитель Корпус QTY Целевая цена Итого
Итого: $0.00 USD
✓
Запрос цены отправлен!

Мы ответим на ваш email в течение 24 часов

1
RFQ отправлен
2
Предложение получено
3
Заказ оформлен
4
Оплата
5
Отправлено
6
Доставлено
Просмотреть детали RFQ