ADS1263IPW - 32-Bit Precision Delta-Sigma ADC | Texas Instruments
Артикул: ADS1263IPW ✓ АктивенADS1263IPW Обзор
A delta-sigma ADC is a category of data converter that uses oversampling, noise shaping, and digital filtering to achieve high resolution and excellent noise performance. The ADS1263 belongs to the ADC hierarchy, where it combines precision signal conditioning and conversion in one device. Its integrated PGA reduces the need for separate analog gain stages, while its reference and fault-monitor functions support sensor-ready measurement chains.
The principal features include 32-bit resolution, a maximum conversion rate of 38 kSPS, and support for as many as 10 analog inputs. The device also includes an auxiliary 24-bit delta-sigma ADC for background measurements, allowing primary-channel and auxiliary measurements to share the same precision-converter family. A 5 V supply and operation from -40°C to +125°C support industrial temperature requirements.
The low-noise, low-drift architecture is appropriate for slow but highly accurate sensor measurements. The programmable PGA can condition low-level bridge, thermocouple, strain-gauge, and pressure-sensor outputs before digitization. Integrated reference and internal fault-monitor functions help simplify system-level diagnostics, although the final accuracy of the complete measurement chain still depends on excitation, reference stability, input filtering, and PCB layout.
Typical uses include weighing systems, factory sensors, pressure and temperature measurement, portable instrumentation, and multichannel data-acquisition systems. The auxiliary ADC can perform background diagnostics while the main ADC handles the primary measurement path, which is useful in systems that monitor sensor health or operating conditions without adding a separate low-speed converter.
For PCB implementation, use a grounded analog plane beneath the converter, route the SPI interface away from sensitive analog inputs, place input and reference components close to their associated pins, and follow the manufacturer layout and grounding guidance. Verify the external reference arrangement, digital supply sequencing, and input common-mode limits before applying power.
This page organizes the ADS1263IPW specifications, verified pricing context, same-package alternatives, application guidance, and design notes into an engineering-focused reference for evaluating and implementing this precision ADC.
Аналоги без доработки для ADS1263IPW — тот же корпус, pin-to-pin совместимость. Компоненты в других корпусах, требующие переработки PCB, исключены.
Варианты в этой серии
Модели той же серии, совместимые без доработки с ADS1263IPW (тот же форм-фактор и посадочное место) — отличается по Package, Fault Monitors, Integrated PGA, Interface, Operating Temperature Range.
ADS1262IPW
✅ Прямая заменаУточнить цену
Открыть даташит →ADS1263IPW Максимальные параметры и электрические характеристики
| Разрешение | 32 bit |
| Maximum Conversion Rate | 38 kSPS |
| Analog Input Count | 5, 10 input |
| ADC Architecture | Delta-sigma |
| Programmable Gain Amplifier | Integrated |
| Voltage Reference | Integrated VREF |
| Auxiliary ADC Resolution | 24 bit delta-sigma |
| Auxiliary ADC Architecture | Delta-sigma |
| Напряжение питания | 5 V |
| Диапазон рабочих температур | -40°C to +125°C |
| Корпус | 28-pin TSSOP |
| Package Body Width | 4.40 mm |
| Lead Pitch | 0.65 mm |
| Lead Finish | Gold |
| Digital Interface | SPI |
| Тип монтажа | Surface mount |
| Internal Fault Monitors | Integrated |
Руководство по цоколевке ADS1263IPW в корпусе 4.40 mm
Цоколевка для ADS1263IPW (корпус 4.40 mm). Этот аналоговый компонент имеет выводы входа, выхода и питания. Обратитесь к техническому описанию производителя для конфигураций выводов балансировки нуля, коррекции и разрешения. Идеально подходит для схем обработки сигналов и усилителей.
Нет подробных данных о распиновке для ADS1263IPW.
Обратитесь к даташиту для полной конфигурации выводов.
Типичное применение
ADS1263IPW подходит для 6 применениеs: Precision Weighing Systems, Industrial Pressure and Flow Monitoring, Thermocouple and Temperature Acquisition, Multichannel Sensor Acquisition, Factory Automation Test Equipment, Portable Instrumentation and Diagnostics.
Precision Weighing Systems
The ADS1263IPW fits precision load-cell and strain-gauge measurement systems that require high resolution rather than high-bandwidth sampling. Its 32-bit delta-sigma converter, integrated programmable gain amplifier, and internal reference provide a compact acquisition path for small differential signals from bridge sensors. The 38-kSPS maximum conversion rate is suitable for updating weight or force values, while digital filtering can suppress mechanical vibration and power-supply noise. The auxiliary 24-bit ADC can separately monitor temperature, excitation status, or another slow diagnostic input without replacing the primary measurement channel. Designers should still account for bridge excitation drift, input settling, common-mode limits, and PCB thermal gradients to preserve the accuracy expected from a high-resolution converter.
Рекомендуется
Industrial Pressure and Flow Monitoring
The ADS1263IPW is appropriate for pressure transmitters, flow meters, and process-control inputs that present low-level analog signals over industrial temperature ranges. Its integrated PGA can condition differential sensor outputs, while the integrated reference and fault-monitor functions help simplify the measurement chain. The device operates from a 5 V supply and is specified across -40°C to +125°C, making it suitable for equipment placed near industrial machinery. The 38-kSPS rate supports responsive process measurements without requiring a high-speed ADC. Use the auxiliary ADC for slow background diagnostics such as sensor temperature or supply monitoring, and apply proper input filtering and shielded routing to prevent motor drives, relays, and switching supplies from corrupting low-level measurements.
Рекомендуется
Thermocouple and Temperature Acquisition
The ADS1263IPW can serve as the precision conversion stage in multi-channel temperature-acquisition equipment, including thermocouple and resistance-based sensor systems. Its 32-bit resolution provides ample code depth for low-level signals, and the integrated PGA helps bring sensor outputs into the converter’s usable range. The low-noise, low-drift architecture is particularly relevant when temperature accuracy is limited by the measurement electronics rather than the sensor itself. The auxiliary ADC can monitor ambient temperature or a reference junction during background measurements. Because thermocouple signals are small, engineers should pay close attention to input protection, cold-junction compensation, differential routing, isolation boundaries, and filtering rather than treating resolution alone as the limiting factor.
Рекомендуется
Multichannel Sensor Acquisition
The ADS1263IPW supports multichannel industrial acquisition by accepting up to 10 analog inputs and multiplexing them through a high-resolution delta-sigma conversion path. This arrangement is useful for systems that scan pressure, temperature, position, or resistance sensors while prioritizing resolution and noise performance over waveform bandwidth. The programmable PGA allows selected channels to use appropriate conditioning ranges, and the 38-kSPS conversion rate provides useful update speed for many slow industrial variables. The auxiliary ADC adds a separate low-speed background path for status monitoring. System-level channel count can still be limited by mux resistance, settling time, source impedance, and the selected digital filter, so each analog branch should be designed to present a stable impedance during conversion.
Рекомендуется
Factory Automation Test Equipment
The ADS1263IPW is suitable for factory test and calibration systems that measure low-level analog parameters during automated production. Its 32-bit resolution, integrated PGA, reference, and fault monitors can reduce the number of discrete precision components around the converter, while the SPI interface supports connection to a controller or data-acquisition processor. The maximum 38-kSPS rate is adequate for many production measurements that do not require high-speed sampling. The auxiliary ADC is useful for background monitoring of fixture conditions or a secondary diagnostic channel. For reliable test results, warm up the analog section as required, keep high-current switching paths away from the measurement traces, and use the manufacturer’s layout and grounding techniques to prevent test-fixture errors from masking converter performance.
Рекомендуется
Portable Instrumentation and Diagnostics
The ADS1263IPW is useful in portable measurement instruments where low power, compactness, and diagnostic visibility are important. Its integrated PGA, reference, auxiliary ADC, and fault-monitor resources reduce the number of external analog components and provide a way to check operating conditions alongside the primary measurement. The 32-bit resolution supports precision readings from resistive, pressure, and level sensors, while the 28-pin TSSOP package supports compact board layouts. A microcontroller can configure the converter and retrieve data over SPI. For battery-powered equipment, account for conversion rate and digital-filter settings when estimating energy use. Use a stable reference arrangement, adequate analog bypassing, and controlled grounding to preserve repeatability across battery voltage and ambient-temperature changes.
Рекомендуется
Сводка рекомендуемых товаров
Справочные инженерные данные для ADS1263IPW — сравнение, рекомендации по проектированию и информация о соответствии.
Руководство по выбору
Сравнение с аналогами
| Параметр | Этот товар | ADS1262IPW |
|---|---|---|
| Package | 28-pin TSSOP | 28-pin TSSOP |
| Brand | Texas Instruments | Texas Instruments |
| Maximum Conversion Rate | 38 kSPS | 38.4 kSPS |
| ADC Architecture | Delta-sigma | Delta-sigma |
| Programmable Gain Amplifier | Integrated | Integrated |
| Auxiliary ADC | 24-bit delta-sigma auxiliary ADC | Not provided |
| Voltage Reference | Integrated VREF | Integrated |
| Internal Fault Monitors | Integrated | Integrated |
| Operating Temperature Range | -40°C to +125°C | -40°C to +125°C |
Ключевые отличия
- Adds an independent auxiliary measurement converter (против ADS1262IPW)
- Combines precision conversion and signal conditioning (против ADS1262IPW)
- Documented pin and function compatibility (против ADS1262IPW)
Заметки по проектированию
Route differential analog inputs as a compact, matched pair and keep the complete analog signal path away from SPI clock, chip-select, and switching-supply nodes. Place the input filtering network and reference components close to their associated pins, and follow the manufacturer’s grounding and layout example. A TSSOP footprint provides limited trace escape space, so component placement and analog-ground partitioning can materially affect noise performance.
Do not treat the 32-bit resolution as the complete system-accuracy specification. Verify the selected PGA gain against the sensor’s common-mode range, allow analog inputs to settle after multiplexing, and confirm the input voltage limits at every operating condition. Also check the auxiliary-ADC and fault-monitor registers in firmware so the ADS1263 is configured consistently with the intended measurement sequence.
Use the manufacturer’s recommended analog and digital supply bypassing network, with each capacitor positioned close to its supply pin and connected through a short return path. Separate noisy switching-current paths from reference and analog return current to reduce supply coupling. Because accuracy depends on reference stability, avoid sharing sensitive reference routing with loads that produce thermal or current disturbances.
SPI signals should have controlled source impedance, series damping where required, and return paths that do not share noisy analog nodes. Establish digital signal levels and timing margins for the selected SPI clock rate. For multiplexed inputs, calculate the settling time available under the programmed data rate and ensure sensor impedance and filter capacitance meet the converter’s acquisition requirements.