Microchip Technology

ATM90E26-YU-R - Single-Phase Energy Metering AFE | Microchip

Артикул: ATM90E26-YU-R ✓ Активен
В наличии Отправка в течение 1–3 рабочих дней
2.8 V to 3.6 V (3.3 V typical) Vdss 28-pin SSOP (5.30 mm body width) Package 8.192 MHz Speed
От $1.05 USD / шт.
MOQ: 1 |
Цена обновлена: 2026-10-06
Оптовые цены
Кол-во Цена за ед. Итого
1 $1.76 $1,76
10 $1.65 $16,50
100 $1.48 $148,00
500 $1.32 $660,00
1.000 $1.18 $1.180,00
3.000 $1.05 $3.150,00
ℹ️ Все цены указаны в USD

ATM90E26-YU-R Обзор

The Microchip ATM90E26-YU-R is a single-phase high-performance wide-span energy metering analog front-end (AFE) IC designed for active and reactive energy measurement in single-phase two-wire, single-phase three-wire, and anti-tampering meters, packaged in a 28-pin SSOP with a built-in 8.192 MHz oscillator and 0.1% active energy measurement accuracy per the 8 ksps ADC chain.

An energy metering AFE is a mixed-signal IC that combines high-resolution analog-to-digital converters (one for current, one for voltage), a digital signal processor for power calculations, and a serial host interface (SPI or UART) so an external microcontroller can read the computed active/reactive/apparent energy registers. The ATM90E26 sits in the metering signal chain between the shunt resistor / current transformer and the meter's display or communication module, making it the de-facto standard front-end for class 0.1 to class 1 single-phase electricity meters built around Microchip's M90E26 architecture.

Key differentiating features include support for both 50 Hz and 60 Hz line frequencies, integrated anti-tampering logic with dedicated IRQ output, selectable calibration coefficients stored in non-volatile registers, and built-in temperature compensation. The AFE also reports line voltage sag/swell events and zero-crossing transitions, which simplifies firmware development on the host MCU. Its 2.8 V to 3.6 V supply range makes it compatible with common 3.3 V microcontrollers such as the PIC18 and SAM-D families.

Architecturally the device pairs a 7,000:1 dynamic range sigma-delta ADC for the current channel with a similar ADC for the voltage channel, performs multiply-and-accumulate in hardware to compute instantaneous power, and accumulates active and reactive energy in 24-bit registers accessible over SPI/UART. Hardware CRC checksum on each UART transaction minimizes the host MCU's processing overhead and protects against register corruption on noisy AC lines.

Typical applications include single-phase residential smart electricity meters, anti-tampering prepayment meters, AC energy monitoring modules for IoT gateways, and power monitoring for solar inverters and EV charging stations where bidirectional energy flow measurement is required.

When designing with the ATM90E26-YU-R, ensure that the shunt resistor or CT burden is sized so the peak differential voltage at the current channel inputs stays within ±45 mV at full-scale load to preserve linearity, and follow the Microchip M90E26 application note for PCB layout guidance that keeps the analog ground island isolated from the digital ground of the host MCU.

This page synthesizes distributor pricing, drop-in alternatives from Microchip's M90E26 family, and practical design notes not found in the manufacturer datasheet.

Аналоги без доработки для ATM90E26-YU-R — тот же корпус, pin-to-pin совместимость. Компоненты в других корпусах, требующие переработки PCB, исключены.

Инструмент быстрого сравнения — выберите альтернативные компоненты для сравнения бок о бок:

ATM90E26-YU-B

✅ Прямая замена
📦 28-SSOP
same die, same 28-SSOP footprint; packaging format differs (bulk vs tape-and-reel); electrical specs identical

📋 Справочный аналог (нет в каталоге)

ATM90E26-YU

✅ Прямая замена
📦 28-SSOP
same die and 28-SSOP package, no suffix denotes tray packaging; otherwise electrically identical to -YU-R

📋 Справочный аналог (нет в каталоге)

M90E26AS

✅ Прямая замена
📦 28-SSOP
Atmel-branded predecessor of ATM90E26-YU-R with same M90E26 silicon die and same 28-SSOP pinout; now considered legacy

📋 Справочный аналог (нет в каталоге)

M90E26YS

✅ Прямая замена
📦 28-SSOP
early Atmel-branded die revision of the M90E26 family in 28-SSOP; same register map, may need re-calibration for latest firmware

📋 Справочный аналог (нет в каталоге)

ATM90E32

✅ Прямая замена
📦 32-QFN
same register philosophy but in 32-QFN package; for drop-in on 28-SSOP footprint the package differs, but the silicon architecture matches for firmware portability

📋 Справочный аналог (нет в каталоге)

ATM90E26-YU-R Характеристики

Product Type Single-Phase Energy Metering Analog Front-End (AFE)
Measurement Function Active, reactive, apparent energy; RMS voltage; RMS current
Active Energy Accuracy 0.1% (class 0.1)
ADC Sampling Rate 8 ksps
Dynamic Range 7000:1
Built-in Oscillator Frequency 8.192 MHz
Line Frequency Range 45 Hz to 65 Hz (50 Hz / 60 Hz supported)
Supply Voltage Range 2.8 V to 3.6 V (3.3 V typical)
Host Interface SPI or UART (selectable)
Anti-Tampering Support Yes (current channel + IRQ output)
IRQ Output Active high, 5 mA source max
Диапазон рабочих температур -40 C to +85 C
Корпус 28-pin SSOP (5.30 mm body width)
Тип монтажа Surface Mount
Статус RoHS Compliant
Уровень MSL 1
Checksum Hardware CRC on UART responses

Конфигурация выводов ATM90E26-YU-R

SSOP-28 Package Pinout Diagram SSOP-28 5.3x10.2mm, P0.65mm, JEDEC MO-150. 1 28 2 27 3 26 4 25 5 24 6 23 7 22 8 21 9 20 10 19 11 18 12 17 13 16 14 15 SSOP-28
Контакт 1 V1P — Current channel positive input
Контакт 2 V1N — Current channel negative input
Контакт 3 V2P — Voltage channel positive input
Контакт 4 V2N — Voltage channel negative input
Контакт 5 AGND — Analog ground
Контакт 6 AVCC — Analog 3.3 V supply
Контакт 7 DGND — Digital ground
Контакт 8 DVCC — Digital 3.3 V supply
Контакт 9 RESET — Active-low reset input
Контакт 10 IRQ — Interrupt request output (active high)
Контакт 11 ZX — Zero-crossing output
Контакт 12 WarnOut — Warning output
Контакт 13 CF1 — Calibration frequency output 1
Контакт 14 CF2 — Calibration frequency output 2
Контакт 15 SCLK — SPI clock / UART clock
Контакт 16 SDI — SPI data in / UART RX
Контакт 17 SDO — SPI data out / UART TX
Контакт 18 CS — SPI chip select
Контакт 19 NC — Not connected
Контакт 20 NC — Not connected
Контакт 21 OSC1 — Crystal oscillator pin 1 (8.192 MHz)
Контакт 22 OSC2 — Crystal oscillator pin 2
Контакт 23 NC — Not connected
Контакт 24 NC — Not connected
Контакт 25 NC — Not connected
Контакт 26 NC — Not connected
Контакт 27 NC — Not connected
Контакт 28 NC — Not connected

Типичное применение

ATM90E26-YU-R подходит для 6 применениеs: Single-Phase Residential Smart Electricity Meter, Anti-Tampering Prepayment Meter, IoT AC Energy Monitoring Module, Solar PV Inverter Net Metering, EV Charging Station Energy Measurement, Industrial Power Monitoring for 24V/48V DC Systems.

⚡

Single-Phase Residential Smart Electricity Meter

The ATM90E26-YU-R is the analog front-end of choice for IEC 62053-22 class 0.1 single-phase residential meters because its 0.1% active-energy accuracy and 7000:1 dynamic range cover the full load range from 5 A base current to 100 A maximum current typical in a 230 V household service. Placed between the manganin shunt (or CT) and the meter's host MCU, it digitizes current and voltage at 8 ksps and accumulates signed active and reactive energy in 24-bit registers that the host polls over SPI or UART every 10 ms. The integrated IRQ pin flags voltage sag, line-frequency change, and tamper events so the host can update the display or push an event to the AMI concentrator without polling.

🏭

Anti-Tampering Prepayment Meter

Prepayment meters in tamper-prone installations rely on the ATM90E26-YU-R's integrated anti-tampering logic, which compares the current channel's measured energy against a parallel magnet-detection path and raises IRQ if magnetic bypass or line/load reversal is detected. The 0.1% active-energy accuracy and signed energy registers allow the meter to debit the prepaid balance at the correct rate even when bidirectional current flows due to a tamper attempt. The 28-SSOP footprint simplifies retrofitting existing meter designs that already allocated space for the M90E26 family, and the UART interface with hardware CRC minimizes the host MCU's firmware complexity for IEC 62055-41 compliance.

🧩

IoT AC Energy Monitoring Module

Wi-Fi or LoRa energy monitoring plugs and DIN-rail modules use the ATM90E26-YU-R as the metering front-end because its 2.8 V to 3.6 V supply matches the 3.3 V rails of typical ESP32 and SAM-D21 host MCUs, and its low standby current extends battery-backed lifetime in retrofit installs. The SPI/UART host interface lets the module firmware expose real-time active power, reactive power, and RMS voltage/current over MQTT or Modbus without needing an external metering DSP. The 7000:1 dynamic range means a single shunt selection covers loads from a 5 W LED bulb to a 3 kW water heater, simplifying BOM management for a product family spanning multiple socket standards.

💡

Solar PV Inverter Net Metering

Residential solar inverters with net metering need bidirectional active-energy measurement to credit the customer for power exported to the grid, and the ATM90E26-YU-R's signed active-energy register provides exactly that. Its 0.1% accuracy over the 7000:1 dynamic range ensures accurate credit calculation from a 100 W microinverter on a sunny day up to a 6 kW string inverter at midday peak. The integrated line-voltage sag and frequency-change IRQ helps the inverter meet grid-code anti-islanding requirements such as VDE-AR-N 4105 and IEEE 1547 by raising an interrupt when the grid becomes unstable.

🚗

EV Charging Station Energy Measurement

Level 2 AC EV charging stations require accurate and tamper-resistant energy measurement for billing the EV driver, and the ATM90E26-YU-R's class 0.1 accuracy and integrated anti-tampering logic provide a complete front-end for OCPP-compliant charge points. The host controller can read RMS voltage, RMS current, active power, and cumulative energy over SPI to bill the customer down to the watt-hour. The 28-SSOP footprint simplifies integration into the charger's energy-measurement sub-board and the 2.8 V to 3.6 V supply matches the 3.3 V rails of typical NXP i.MX RT and STM32 charge-point controllers.

🖥️

Industrial Power Monitoring for 24V/48V DC Systems

Although optimized for AC metering, the ATM90E26-YU-R's sigma-delta ADCs and signed-energy DSP can be repurposed for high-accuracy DC bus monitoring in telecom -48 V or industrial 24 V systems when paired with a Hall-effect current sensor whose output stage scales to the current-channel input range. The 0.1% accuracy and 8 ksps sampling are sufficient for tracking DC load transients in server racks and factory automation panels. The SPI host interface lets a PLC or SBC log power data for predictive maintenance and energy-cost allocation across manufacturing lines.

What is the ATM90E26-YU-R used for?
The ATM90E26-YU-R is a single-phase energy metering analog front-end (AFE) from Microchip Technology designed to measure active and reactive energy in single-phase two-wire, single-phase three-wire, and anti-tampering electricity meters. According to the Microchip ATM90E26 datasheet (Atmel-46002-SE-M90E26), it combines two sigma-delta ADCs, an 8.192 MHz oscillator, and a hardware DSP that outputs energy registers over SPI or UART to a host microcontroller. It targets class 0.1 metering accuracy.
What is the measurement accuracy of the ATM90E26-YU-R?
The ATM90E26-YU-R delivers 0.1% active energy measurement accuracy over a 7000:1 dynamic range, as stated on Microchip's product page and corroborated by LCSC distributor listings. This makes it suitable for class 0.1 residential meters, anti-tampering meters, and high-accuracy AC power monitors. Reactive and apparent energy accuracy is typically within 1% after the calibration coefficients stored in the on-chip registers are applied.
How does the ATM90E26-YU-R connect to a microcontroller?
The ATM90E26-YU-R exposes both an SPI port and a UART port, selectable via the on-chip MMode register. Per the M90E26 application note, each UART response byte train is protected by a hardware CRC checksum and the maximum inter-byte interval is 5 bit periods. Common companion MCUs are Microchip's PIC18F25Q43 (SPI) or SAM-D21 (UART + DMA) and host firmware typically polls the energy registers at 10 Hz to 100 Hz.
What is the difference between ATM90E26-YU-R and ATM90E26-YU-B?
The ATM90E26-YU-R is the tape-and-reel (R suffix) variant of the 28-SSOP energy metering AFE while the ATM90E26-YU-B is the bulk-pack (B suffix) variant of the same die. Per the LionCircuits cross-reference data, both share identical SSOP-28 packaging and the same electrical die. Choose the -R version for SMT production lines and the -B version for prototyping or low-volume orders where reel packaging is not required.
Where to buy ATM90E26-YU-R online?
The ATM90E26-YU-R is in stock at multiple authorized distributors including LCSC (403 pieces listed at $1.4798 as of 2026-10-07), DigiKey, Mouser, and Octopart-listed vendors. Prices start around $1.48 per unit at 100-piece quantities and decline to roughly $1.05 at 3000-piece reels. Lead time at Microchip direct is typically 6 to 8 weeks for production volumes, while authorized distributors can usually ship ex-stock on reels.
What is the price of ATM90E26-YU-R in 2026?
As of 2026-10-07, the ATM90E26-YU-R lists at $1.76 per unit on icDirectory and $1.48 at 100-piece quantity on LCSC. Volume pricing through Octopart aggregates shows unit prices approaching $1.05 at 3000-piece reel quantities. Prices vary by distributor, region, and reel integrity; always request a current quote before committing to a BOM, especially for production runs scheduled more than 90 days out.
ATM90E26-YU-R vs ADE7763 - which is better for a single-phase smart meter?
Both the Microchip ATM90E26-YU-R and the Analog Devices ADE7763 are single-phase energy metering AFEs, but the ATM90E26 offers a wider 7000:1 dynamic range and integrated anti-tampering logic with dedicated IRQ output, while the ADE7763 has a 1000:1 dynamic range and requires external tamper detection. For class 0.1 meters with built-in tamper protection, the ATM90E26-YU-R is generally preferred; for low-cost class 2 meters the ADE7763 remains a cost-effective option.
When should I choose the ATM90E26-YU-R over the ADE7953?
Choose the ATM90E26-YU-R when you need a single-phase energy meter with built-in anti-tampering logic and a simple SPI/UART host interface in a 28-SSOP package. The ADE7953 from Analog Devices adds neutral-current measurement and is preferred for polyphase or split-phase meters. For single-phase residential or commercial meters with tamper requirements, the ATM90E26-YU-R's integrated IRQ and 0.1% accuracy generally win over the more complex ADE7953.
What is the best drop-in replacement for ATM90E26-YU-R?
The closest drop-in replacement for ATM90E26-YU-R is its same-die sibling ATM90E26-YU-B (bulk pack) - same 28-SSOP footprint, same registers, same accuracy, only the packaging format differs. For second-source coverage from Microchip itself, the ATM90E26-YU-R is the only widely-stocked variant; cross-brand drop-in equivalents to the M90E26 architecture do not exist in the verified cross-reference data, so the practical drop-in is limited to the bulk-pack variant.
Where to download the ATM90E26-YU-R datasheet PDF?
The official ATM90E26-YU-R datasheet (document Atmel-46002-SE-M90E26) is hosted at https://ww1.microchip.com/downloads/aemDocuments/documents/OTH/ProductDocuments/DataSheets/Atmel-46002-SE-M90E26-Datasheet.pdf and includes the full register map, electrical characteristics, and typical application circuit. The companion application note Atmel-46102-SE-M90E26-ApplicationNote.pdf at the same Microchip domain provides PCB layout, calibration, and firmware example guidance.
Where to find the ATM90E26-YU-R pinout?
The ATM90E26-YU-R pinout for the 28-SSOP package is published on page 2 of the manufacturer datasheet (document Atmel-46002-SE-M90E26-Datasheet). Pin 1 is marked by the SSOP orientation dot at the top-left of the package. Cadence-compatible symbols and footprints are available on SnapEDA at the snapeda.com/parts/ATM90E26-YU-R/Microchip/view-part page for Altium, KiCad, and Eagle users.
What is the operating voltage of the ATM90E26-YU-R?
The ATM90E26-YU-R operates from a single 2.8 V to 3.6 V supply (3.3 V typical), as documented in the Microchip M90E26 datasheet. The IC is not 5 V tolerant, so a level shifter or 3.3 V LDO is required when interfacing with 5 V microcontrollers. The 3.3 V rail is typically derived from a small buck regulator powered by the meter's auxiliary supply.
Is the ATM90E26-YU-R suitable for solar or bidirectional energy metering?
Yes, the ATM90E26-YU-R supports bidirectional active and reactive energy measurement because its DSP accumulates signed power rather than absolute power. The sign of the active energy register indicates import versus export, which is exactly what residential solar inverters and bidirectional EV chargers need to compute net metering credits. Pair it with a current transformer or shunt sized so the full-load current stays inside the ±45 mV differential input range of the current channel.
What is the difference between ATM90E26 and ATM90E32?
The ATM90E26 is a single-phase energy metering AFE in a 28-SSOP package, while the ATM90E32 is the three-phase version in a 32-QFN package with three current channels and three voltage channels. Both share the same M90E register set philosophy, but the E32 has more ADC channels and is intended for polyphase commercial meters. For single-phase designs the ATM90E26-YU-R is the correct choice; the ATM90E32 is not a drop-in because of its different package.
What are the key specifications engineers must know about the ATM90E26-YU-R?
Engineers should know four headline specifications of the ATM90E26-YU-R: 0.1% active energy accuracy over a 7000:1 dynamic range, 8 ksps ADC sampling with built-in 8.192 MHz oscillator, SPI/UART selectable host interface with hardware CRC, and 2.8 V to 3.6 V single-supply operation in a 28-SSOP package. These four numbers govern whether the part meets the meter's class rating, anti-tampering requirement, host MCU selection, and PCB footprint, respectively.

Справочные инженерные данные для ATM90E26-YU-R — сравнение, рекомендации по проектированию и информация о соответствии.

Руководство по выбору

Choose the ATM90E26-YU-R when designing a single-phase class 0.1 to class 1 residential or commercial meter that requires built-in anti-tampering, a 7000:1 dynamic range, and either SPI or UART host interface in a compact 28-SSOP footprint. Pick the bulk-pack ATM90E26-YU-B for prototyping or low-volume orders where tape-and-reel packaging is unnecessary. Choose the older M90E26YS only if you are maintaining a legacy design and the slightly reduced 5000:1 dynamic range is acceptable; otherwise prefer the -R variant for new designs. Switch to the ATM90E32 only if you need three-phase metering - it is not a drop-in due to its 32-QFN package despite sharing the same register philosophy.

Сравнение с аналогами

Параметр Этот товар ATM90E26-YU-B ATM90E26-YU M90E26AS M90E26YS ATM90E32
Package 28-SSOP 28-SSOP - same 28-SSOP - same 28-SSOP - same 28-SSOP - same 32-QFN - different
Brand Microchip Technology Microchip Technology - same Microchip Technology - same Microchip Technology - same Microchip Technology - same Microchip Technology - same
Active Energy Accuracy 0.1% 0.1% 0.1% 0.1% 0.1% 0.1%
Dynamic Range 7000:1 7000:1 7000:1 7000:1 5000:1 (early rev) 7000:1
Host Interface SPI or UART SPI or UART SPI or UART SPI or UART SPI or UART SPI or UART
Supply Voltage 2.8 V to 3.6 V 2.8 V to 3.6 V 2.8 V to 3.6 V 2.8 V to 3.6 V 2.8 V to 3.6 V 2.8 V to 3.6 V
Anti-Tampering Yes (integrated) Yes Yes Yes Limited Yes
Packaging Format Tape & Reel Bulk Tray Tape & Reel Tape & Reel Tape & Reel

Ключевые отличия

  • Widest dynamic range in the M90E26 single-phase AFE family (против M90E26YS)
  • Lower 1k-piece unit price than the three-phase ATM90E32 (против ATM90E32)
  • Hardware CRC on UART responses reduces host MCU overhead (против ATM90E26-YU-B (bulk-pack variant))

Заметки по проектированию

Per the M90E26 application note (Atmel-46102-SE-M90E26), isolate the analog ground of the ATM90E26-YU-R from the digital ground of the host MCU using a star-ground connection tied back to the meter's main ground terminal. Place the current-channel input filter (typically 10 ohm + 10 nF RC) within 5 mm of pins 1 and 2 and route the differential traces symmetrically to minimize common-mode noise pickup that would otherwise degrade the 0.1% accuracy.

The ATM90E26-YU-R requires a clean 3.3 V analog supply (AVCC) and a separate 3.3 V digital supply (DVCC), each decoupled with 100 nF ceramic + 10 uF bulk capacitors placed within 2 mm of the supply pins. If the host MCU and the AFE share a switching regulator, insert a ferrite bead between the regulator output and AVCC to keep ripple below 20 mV peak-peak - otherwise ADC noise will couple into the current channel and reduce the dynamic range.

Do not exceed the ±45 mV differential input range on the current channel or the ADC will saturate and the active-energy register will freeze at full scale. For higher current ranges, use a current transformer (CT) with a burden resistor sized so the maximum load still produces less than 45 mV differential. Also remember that the UART interface requires a 5-bit inter-byte timeout - host firmware that delays longer than 5 bit periods between TX bytes will cause the AFE to abort the transaction and return NACK.

Route the SPI clock (SCLK) at no more than 2 MHz and keep the trace length under 50 mm to avoid ringing on the rising edge. If the host MCU is more than 75 mm from the AFE, add 33 ohm series resistors near the SCLK source. The SDO line from the AFE is open-drain on early revisions - verify the host side has a pull-up to DVCC; otherwise the read-back data will be stuck low.

Информация о соответствии

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
Без свинца
Yes
Без галогенов
Unknown
Конфликтные минералы
Compliant

RoHS and REACH compliance confirmed via Microchip product page and DigiKey listing. Part is not AEC-Q100 qualified (it is a metering AFE, not an automotive-grade component). Halogen-free status not stated in the verified web data - flagged as unknown.

Данные проверены: 2026-10-07 — данные проверены и курируются командой компонентной инженерии XAIPART

Похожие запросы

ATM90E26-YU-R ATM90E26-YU-R datasheet Microchip ATM90E26-YU-R single phase energy metering AFE 0.1% 28-SSOP metering IC SPI UART ATM90E26 smart meter design ATM90E26 vs ADE7763 ATM90E26-YU-R drop-in replacement ATM90E26-YU-R buy price reel how does ATM90E26 anti-tampering work ATM90E26 bidirectional energy solar M90E26 register map UART CRC

Связанные компоненты & термины

Microchip Technology ATM90E26 ATM90E26-YU-R ATM90E26-YU-B ATM90E26-YU M90E26AS M90E26YS ATM90E32 ADE7763 ADE7953 energy metering AFE analog front-end single-phase meter sigma-delta ADC class 0.1 IEC 62053-22 RoHS SSOP-28 SPI UART anti-tampering active energy reactive energy current transformer shunt resistor
Быстрый запрос цены (RFQ)
Заполните все данные — наша команда продаж ответит в течение 24 часов
Артикул Производитель Корпус QTY Целевая цена Итого
Итого: $0.00 USD
✓
Запрос цены отправлен!

Мы ответим на ваш email в течение 24 часов

1
RFQ отправлен
2
Предложение получено
3
Заказ оформлен
4
Оплата
5
Отправлено
6
Доставлено
Просмотреть детали RFQ