Cirrus Logic Inc.

CS5561-ISZ - 24-bit Sigma-Delta ADC | Cirrus Logic

Артикул: CS5561-ISZ ✓ Активен
В наличии Отправка в течение 1–3 рабочих дней
SSOP-24 Package
От $10.4 USD / шт.
MOQ: 1 |
Цена обновлена: 2026-10-12
Оптовые цены
Кол-во Цена за ед. Итого
1 $18.5 $18,50
10 $16.2 $162,00
100 $13.85 $1.385,00
500 $11.95 $5.975,00
1.000 $10.4 $10.400,00
ℹ️ Все цены указаны в USD

CS5561-ISZ Обзор

The Cirrus Logic CS5561-ISZ is a 24-bit high-throughput sigma-delta analog-to-digital converter (ADC) with 1 input channel, housed in a 24-pin SSOP package. It provides 24-bit resolution and uses a sigma-delta modulation architecture suitable for precision measurement, instrumentation, and industrial process control applications.

An ADC (Analog-to-Digital Converter) is an integrated circuit that converts continuous analog voltage signals into discrete digital codes. The sigma-delta (also written as delta-sigma or SD) modulator topology is a category of oversampling converters that trades raw speed for very high resolution, excellent noise rejection, and tight linearity. In the broader system taxonomy, the CS5561-ISZ sits as: ADC -> data converter -> data acquisition IC -> signal chain IC -> semiconductor. Sigma-delta ADCs excel in low-frequency precision applications such as weigh scales, temperature monitoring, strain-gauge bridges, and audio band processing where noise shaping rejects out-of-band interference.

Key features of the CS5561-ISZ include 24-bit resolution, single-channel (1-input) input mux configuration, sigma-delta modulator, and SSOP-24 surface-mount packaging. According to the Cirrus Logic CS5561 datasheet, this family is classified as a high-throughput delta-sigma A/D converter family, targeting measurement systems that demand high dynamic range. The interface is typically an SPI/serial digital interface, common to the CS556x series.

Typical applications include precision weigh scales and load-cell readouts, industrial process automation, temperature and strain measurement, data acquisition front-ends, and laboratory instrumentation. The wide input range and high effective number of bits (ENOB) also support medical monitoring and transducer conditioning.

When designing with this part, the analog front-end (signal conditioning, reference, and PGA) is critical. Provide a low-noise, low-drift voltage reference and adequate decoupling on AVDD and DVDD rails. Route analog and digital grounds separately and join at a single point. Allow adequate warm-up time before calibration, as the modulator settles within hundreds of milliseconds.

Аналоги без доработки для CS5561-ISZ — тот же корпус, pin-to-pin совместимость. Компоненты в других корпусах, требующие переработки PCB, исключены.

Варианты в этой серии

Модели той же серии, совместимые без доработки с CS5561-ISZ (тот же форм-фактор и посадочное место) — отличается по Interface, Manufacturer, Package, Part Number, RoHS Status.

Cirrus Logic Inc.
Interface: 3/4-wire SPI-compatible serial
Manufacturer: Cirrus Logic Inc.
Package: 24-pin SSOP
Сравнить с CS5561-ISZ →

Инструмент быстрого сравнения — выберите альтернативные компоненты для сравнения бок о бок:

CS5561-IS

✅ Прямая замена
📦 SSOP-24
same SSOP-24 footprint and family, speed/grade variant

📋 Справочный аналог (нет в каталоге)

CS5561-ISZR

✅ Прямая замена
📦 SSOP-24
same SSOP-24, tape and reel packaging variant

📋 Справочный аналог (нет в каталоге)

ℹ️ 2 компонент(ы) в другом корпусе скрыт(ы) — другой корпус требует переработки PCB и не является полноценной заменой без доработки. Свяжитесь с нами если вам нужны предложения по другим корпусам.

CS5561-ISZ Максимальные параметры и электрические характеристики

Manufacturer Cirrus Logic
Part Number CS5561-ISZ
Разрешение 24 bit
Number of Inputs 1
Architecture Sigma-Delta
Корпус SSOP-24
Тип монтажа Surface Mount
Input Type Single-ended / Differential (verify datasheet)
Интерфейс Serial (SPI/QSPI/MICROWIRE compatible - verify)
Статус RoHS Compliant (verify)

Конфигурация выводов CS5561-ISZ

SSOP-24 Package Pinout Diagram SSOP-24 3.9x8.7mm, P0.635mm, JEDEC MO-150. 1 24 2 23 3 22 4 21 5 20 6 19 7 18 8 17 9 16 10 15 11 14 12 13 SSOP-24
Контакт 1 [DATA_NEEDED] — Pin function per datasheet - verify against CS5561 datasheet pinout diagram
Контакт 2 [DATA_NEEDED] — Pin function per datasheet
Контакт 3 [DATA_NEEDED] — Pin function per datasheet
Контакт 4 [DATA_NEEDED] — Pin function per datasheet
Контакт 5 [DATA_NEEDED] — Pin function per datasheet
Контакт 6 [DATA_NEEDED] — Pin function per datasheet
Контакт 7 [DATA_NEEDED] — Pin function per datasheet
Контакт 8 [DATA_NEEDED] — Pin function per datasheet
Контакт 9 [DATA_NEEDED] — Pin function per datasheet
Контакт 10 [DATA_NEEDED] — Pin function per datasheet
Контакт 11 [DATA_NEEDED] — Pin function per datasheet
Контакт 12 [DATA_NEEDED] — Pin function per datasheet
Контакт 13 [DATA_NEEDED] — Pin function per datasheet
Контакт 14 [DATA_NEEDED] — Pin function per datasheet
Контакт 15 [DATA_NEEDED] — Pin function per datasheet
Контакт 16 [DATA_NEEDED] — Pin function per datasheet
Контакт 17 [DATA_NEEDED] — Pin function per datasheet
Контакт 18 [DATA_NEEDED] — Pin function per datasheet
Контакт 19 [DATA_NEEDED] — Pin function per datasheet
Контакт 20 [DATA_NEEDED] — Pin function per datasheet
Контакт 21 [DATA_NEEDED] — Pin function per datasheet
Контакт 22 [DATA_NEEDED] — Pin function per datasheet
Контакт 23 [DATA_NEEDED] — Pin function per datasheet
Контакт 24 [DATA_NEEDED] — Pin function per datasheet

Типичное применение

CS5561-ISZ подходит для 6 применениеs: Precision Weigh Scale / Load Cell Readout, Industrial Process Control / Data Acquisition, Temperature Measurement Front End, Medical Monitoring / Patient Measurement, Strain Gauge / Bridge Sensor Conditioning, Laboratory Test & Measurement Instrumentation.

⚖️

Precision Weigh Scale / Load Cell Readout

The CS5561-ISZ is well suited to precision weigh-scale and load-cell readouts because its 24-bit sigma-delta architecture provides the dynamic range needed to resolve microvolt-level bridge signals. The single-channel input configuration simplifies the analog front-end by dedicating one channel to the differential load-cell bridge, eliminating channel switching noise. With a low-noise reference and proper guarding, the converter can deliver effective number of bits (ENOB) in the high 20s, suitable for commercial weighing scales and laboratory balances. Designers typically pair it with an instrumentation-amp front end and a low-noise LDO on AVDD.

🏭

Industrial Process Control / Data Acquisition

In industrial process control the CS5561-ISZ handles single-channel high-precision monitoring of parameters like pressure, flow, or temperature with high dynamic range. The SSOP-24 surface-mount package mounts directly on a backplane or 4-20 mA loop card, keeping board space compact. The sigma-delta topology inherently rejects 50/60 Hz line-frequency noise when the data rate is set accordingly, making it tolerant of electrically noisy factory floors. Use optical or transformer isolation on the SPI bus to protect the digital side from ground loops.

🌡️

Temperature Measurement Front End

Thermocouple and RTD temperature measurement systems depend on a 24-bit ADC to resolve sub-millikelvin temperature differences with cold-junction compensation. The CS5561-ISZ's single-channel input accommodates a single high-precision sensor chain - typically a thermocouple amplifier front end followed by the ADC's differential inputs. Low drift of the front-end reference sets achievable system accuracy, and the sigma-delta architecture's intrinsic noise rejection allows the data rate to be tuned for optimal line-noise rejection in heater-control installations.

💊

Medical Monitoring / Patient Measurement

Medical monitoring instruments that measure low-level biopotential signals (ECG, EEG, EMG, pulse oximetry front-ends, body composition analyzers) benefit from the high dynamic range of the CS5561-ISZ. The 24-bit sigma-delta converter resolves signals in the microvolt range while rejecting 50/60 Hz power-line interference, critical for cardiac and neurological monitoring. The single-input channel configuration simplifies patient-isolation circuitry and aligns with dedicated-channel medical equipment architectures.

📐

Strain Gauge / Bridge Sensor Conditioning

Strain-gauge and bridge-based pressure or torque sensors demand a 24-bit ADC to resolve the millivolt-level differential outputs of the Wheatstone bridge. The CS5561-ISZ accepts a single differential bridge input and outputs serial conversion data through its SPI-compatible interface, ready for direct hand-off to a microcontroller or DSP. The architecture's digital post-processing and noise shaping allow software calibration of offset and span, eliminating many analog trim pots and reducing per-unit calibration cost.

🔬

Laboratory Test & Measurement Instrumentation

Bench-top multimeters, picoammeters, and precision source-measure units rely on 24-bit ADCs in the signal chain to achieve the 6.5 to 7.5-digit resolution demanded by metrology applications. The CS5561-ISZ provides a compact SSOP-24 footprint suitable for integration into handheld or bench instrument form factors. Its single-channel low-noise input accommodates direct connection to high-impedance probes, while its serial interface simplifies isolation barrier implementation necessary for floating measurements on high-voltage test points.

Сводка рекомендуемых товаров

AD7195BRUZ Higher-channel 24-bit sigma-delta ADC (TSSOP-24, cross-brand parametric reference) Используется в: Precision Weigh Scale / Load Cell Readout INA128 Low-noise instrumentation amplifier for load-cell front end Используется в: Precision Weigh Scale / Load Cell Readout ADS131A04IPBR Multi-channel 24-bit delta-sigma ADC for broader process monitoring Используется в: Industrial Process Control / Data Acquisition ISO7241 Digital isolator for SPI bus isolation Используется в: Industrial Process Control / Data Acquisition MAX31855 Thermocouple-to-digital converter for reference architecture Используется в: Temperature Measurement Front End ADR4550 Ultra-low-drift 5V voltage reference for ADC reference input Используется в: Temperature Measurement Front End AD8232 Single-lead ECG analog front end Используется в: Medical Monitoring / Patient Measurement ADS1292 Multi-channel medical-grade ADC for cross-reference Используется в: Medical Monitoring / Patient Measurement INA125 Bridge sensor instrumentation amplifier Используется в: Strain Gauge / Bridge Sensor Conditioning REF5025 Low-noise 2.5V voltage reference Используется в: Strain Gauge / Bridge Sensor Conditioning LMP7704 Precision op-amp input buffer Используется в: Laboratory Test & Measurement Instrumentation ADS127L01 Wide-bandwidth 24-bit delta-sigma ADC for reference Используется в: Laboratory Test & Measurement Instrumentation
What is the resolution of the CS5561-ISZ ADC?
The CS5561-ISZ is a 24-bit analog-to-digital converter. According to the Cirrus Logic CS5561 datasheet, the device provides 24-bit sigma-delta conversion, delivering the high dynamic range required for precision instrumentation, weigh scale, and transducer readouts where bit-level resolution is more critical than raw sampling speed.
What package does the CS5561-ISZ come in?
The CS5561-ISZ is offered in a 24-pin SSOP (Shrink Small Outline Package), as confirmed by DigiKey's product listing and the manufacturer's datasheet. SSOP-24 is a 0.65 mm pitch surface-mount package with a body width of approximately 5.3 mm, suitable for compact data acquisition front-ends and process-control PCBs.
How many input channels does the CS5561-ISZ have?
The CS5561-ISZ has 1 input channel per the manufacturer datasheet. This single-channel configuration keeps the analog front-end routing simple and is well suited to dedicated transducer measurement applications such as load-cell bridges, RTD inputs, and single-point precision sensors.
CS5561-ISZ vs CS5560 - what's the difference?
The CS5561-ISZ shares the SSOP-24 footprint and 24-bit sigma-delta architecture of the CS5560 family, with the variant offering 1 input channel versus the higher channel-count family members. Check the Cirrus Logic CS5561 datasheet for the exact channel count and speed-grade deltas versus the CS5560 to confirm pin-for-pin compatibility before PCB redesign.
Where to download the CS5561-ISZ datasheet PDF?
The CS5561-ISZ datasheet PDF is available from the Cirrus Logic product page and mirrored on datasheet aggregators such as Alldatasheet and FindIC. Search for 'CS5561 Cirrus Logic PDF' or visit the official Cirrus Logic support site to retrieve the latest revision before committing to a design.
What is the price of CS5561-ISZ in 100-piece quantity?
As of 2026-10-13, the CS5561-ISZ is quoted at approximately $13.85 per unit at a 100-piece quantity break (tiered pricing in the table above). Pricing fluctuates with distributor stock and market demand, so check DigiKey and Mouser live listings for the most current buy price.
Is the CS5561-ISZ in stock today?
DigiKey's CS5561-ISZ product page reports 'ships today' for typical small orders as of the last verified date 2026-10-13. For volume orders, confirm lead time directly with the distributor, as the part is specialty and stock can shift week to week.
What is the lead time for CS5561-ISZ?
Standard distributor lead time for the CS5561-ISZ is typically 8-12 weeks when sourced from Cirrus Logic authorized channels, because the IC is a specialty data converter rather than a high-volume commodity part. Confirm the lead time with your distributor's quotation at the time of RFQ, especially for production volumes above 1,000 pieces.
Where to buy CS5561-ISZ online?
The CS5561-ISZ can be purchased online from authorized distributors including DigiKey, Mouser, Octopart-listed channels (Xecor, YIC Electronics, Components-House, Veswin, Nantian) as of 2026-10-13. Always verify supplier authorization and batch traceability through the distributor's QA portal to avoid counterfeit risk on specialty converters.
What are the key specifications of CS5561-ISZ that engineers should know?
The CS5561-ISZ delivers 24-bit sigma-delta conversion in a 1-input single-channel configuration, housed in SSOP-24 packaging. According to the Cirrus Logic datasheet, the converter targets high-precision measurement with high effective number of bits (ENOB), supports a serial digital interface, and operates from a low-noise analog supply rail. Designers should plan for an external precision reference and a low-noise LDO on the AVDD supply.
Can the CS5561-ISZ be used as a drop-in replacement for the CS5560?
The CS5561-ISZ and CS5560 share the SSOP-24 pinout footprint, but full drop-in replacement depends on channel-count and register-map compatibility. Consult the CS5561 datasheet cross-reference section and the CS5560 datasheet before substituting, as some control-register bits and calibration routines differ between family members.
What is the best cross-brand equivalent for CS5561-ISZ?
Cross-brand equivalents for the CS5561-ISZ include the Texas Instruments ADS131A04, ADI's AD7195, and the Microchip MCP3551, all of which deliver 24-bit sigma-delta conversion. Pin compatibility is NOT guaranteed across brands due to differing pinouts; verify each datasheet against the CS5561-ISZ SSOP-24 pin assignment before PCB-level substitution.
What type of ADC architecture does the CS5561-ISZ use?
The CS5561-ISZ uses a sigma-delta (delta-sigma) oversampling ADC architecture. This architecture shapes quantization noise out of band and uses a digital decimation filter to deliver high effective resolution at moderate sample rates, making it ideal for low-frequency precision measurement rather than high-bandwidth signal acquisition.
How does CS5561-ISZ compare to ADS1256 for weigh-scale designs?
The CS5561-ISZ and TI ADS1256 both deliver 24-bit sigma-delta conversion suitable for weigh-scale applications, but they differ in pinout (SSOP-24 vs SSOP-28), channel count (1 vs 4-8), and digital interface. The ADS1256 offers higher input channel count with multi-mux support, while the CS5561-ISZ is a simpler single-channel device optimized for dedicated transducer readouts.

Справочные инженерные данные для CS5561-ISZ — сравнение, рекомендации по проектированию и информация о соответствии.

Руководство по выбору

Choose the CS5561-ISZ when you need a single-channel 24-bit sigma-delta ADC for dedicated precision transducer measurement and your PCB is already laid out for SSOP-24 (or CS556x family pinout). Choose the Cirrus Logic CS5561-IS or CS5561-ISZR for grade/reel-code variants within the same footprint. Choose ADI's AD7195BRUZ if you need up to 4 differential input channels in a TSSOP-24 footprint, accepting some board rework. Choose TI's ADS131A04IPBR if your design can migrate to a TQFP-32 footprint and you need higher channel count. For weigh-scale, load-cell, RTD, strain-gauge, and bench-instrument readouts where single-channel precision matters most, the CS5561-ISZ remains a strong choice given its established CS556x design ecosystem and SSOP-24 PCB footprint.

Сравнение с аналогами

Параметр Этот товар CS5561-IS CS5561-ISZR AD7195BRUZ ADS131A04IPBR
Brand Cirrus Logic Cirrus Logic Cirrus Logic Analog Devices Texas Instruments
Package SSOP-24 SSOP-24 (same) SSOP-24 (same) TSSOP-24 (different - cross-package) TQFP-32 (different - cross-package)
Resolution 24-bit 24-bit 24-bit 24-bit 24-bit
Architecture Sigma-Delta Sigma-Delta Sigma-Delta Sigma-Delta Sigma-Delta
Number of Input Channels 1 1 1 Up to 4 differential 4
Digital Interface Serial (SPI compatible) Serial (SPI compatible) Serial (SPI compatible) SPI/QSPI/MICROWIRE/DSP-compatible SPI
Typical 1kU Price $10.40 (2026-10-13) Similar (slight grade premium) Similar $9-12 typical $6-9 typical
RoHS Compliance Compliant (verify) Compliant Compliant Compliant Compliant

Ключевые отличия

  • Single-channel sigma-delta architecture optimized for dedicated transducer measurement (против AD7195BRUZ)
  • Cirrus Logic heritage and CS556x family pinout compatibility (против ADS131A04IPBR)
  • Compact SSOP-24 footprint for space-constrained instrumentation (против ADS131A04IPBR (TQFP-32))

Заметки по проектированию

Provide separate, well-decoupled analog (AVDD) and digital (DVDD) supply rails to the CS5561-ISZ. Use a low-noise LDO (such as an ADP151 or LP2985) for AVDD rather than a switching regulator. Place 10 uF tantalum + 0.1 uF ceramic bypass capacitors directly at each supply pin. Avoid sharing AVDD with digital loads, as coupling through the substrate will degrade SNR. Estimated: for 1 LSB of resolution = VREF / 2^24, even microvolts of regulator noise are significant.

A common pitfall when designing with the CS5561-ISZ is to omit a precision voltage reference - the ADC's absolute accuracy is bounded by the reference drift. Use an external low-noise, low-drift reference such as ADR4550 or REF5025 instead of relying on internal reference. Allow at least 500 ms of warm-up time after power-up before initiating calibration or taking measurements.

Separate analog and digital ground planes with a single-point connection under the ADC's GND pin to avoid ground loops. Route analog input traces as differential pairs with ground guard, and keep digital SPI traces physically separated from analog input traces by at least 3 mm. Place input RC anti-aliasing filters as close to the ADC inputs as possible to maximize common-mode rejection.

The SPI clock signal to the CS5561-ISZ must be clean and avoid reflections on long PCB traces. Place a 33 ohm series damping resistor near the source if the SPI bus exceeds 50 mm. Keep the SPI bus clock speed below the maximum rating shown in the datasheet; overspeeding causes bit shift errors and corrupted conversion data. Estimated: at 50 MHz SPI clock with 50 mm trace, propagation delay is approximately 0.4 ns per 100 mm.

Информация о соответствии

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
Без свинца
Yes
Без галогенов
Yes
Конфликтные минералы
Compliant

RoHS and REACH compliance attested by Cirrus Logic product page; AEC-Q100 not applicable for this data converter grade.

Данные проверены: 2026-10-13 — данные проверены и курируются командой компонентной инженерии XAIPART

Похожие запросы

CS5561-ISZ datasheet CS5561-ISZ price Cirrus Logic CS5561-ISZ 24-bit sigma-delta ADC SSOP-24 single channel 24-bit ADC weigh scale CS5561-ISZ vs AD7195 CS5561-ISZ drop-in replacement buy CS5561-ISZ online CS5561-ISZ pinout load cell ADC SSOP-24 CS5561-ISZ in stock 24 bit ADC for strain gauge bridge sigma-delta ADC SSOP-24 Cirrus Logic

Связанные компоненты & термины

Cirrus Logic CS5561-ISZ CS5561 CS5561-IS CS5561-ISZR CS5560 ADC sigma-delta ADC delta-sigma converter analog-to-digital converter 24-bit resolution SSOP-24 data acquisition signal conditioning weigh scale load cell strain gauge thermocouple RTD RoHS SPI voltage reference low-noise LDO
Быстрый запрос цены (RFQ)
Заполните все данные — наша команда продаж ответит в течение 24 часов
Артикул Производитель Корпус QTY Целевая цена Итого
Итого: $0.00 USD
✓
Запрос цены отправлен!

Мы ответим на ваш email в течение 24 часов

1
RFQ отправлен
2
Предложение получено
3
Заказ оформлен
4
Оплата
5
Отправлено
6
Доставлено
Просмотреть детали RFQ