LT1014ISW - Quad Precision Op Amp, 16-SO | ADI
Артикул: LT1014ISW ✓ АктивенLT1014ISW Обзор
A precision operational amplifier is a voltage-feedback amplifier that uses high open-loop gain to reduce differential input error and produce an output proportional to the voltage between its differential inputs. The LT1014 belongs to the operational-amplifier, analog-signal-conditioning, semiconductor, and power-management application hierarchy. Four amplifiers in one package can support instrumentation channels, active filters, threshold circuits, and current-loop signal conditioning while reducing board area.
The LT1014’s principal features combine low offset, low drift, high common-mode rejection, and high power-supply rejection. The 50 µV offset specification is particularly useful because the quad configuration does not provide offset-null terminals. A guaranteed maximum supply current of 500 µA supports low-power instrumentation, while the 350 µA operating current cited by Analog Devices highlights its low-power biasing. Single-supply operation also permits designs that cannot provide a negative rail.
The LT1013/LT1014 family uses precision design techniques that minimize input offset voltage, input bias current, and supply-current demand. The 0.07 pA/√Hz current-noise figure makes the amplifier suitable for high-impedance transducers, and the 8 million open-loop gain supports accurate closed-loop amplification. Common-mode rejection of 117 dB and power-supply rejection of 120 dB help preserve signal integrity when supply noise or input common-mode voltage is present.
Typical applications include battery-powered precision instrumentation, strain-gauge signal conditioners, thermocouple amplifiers, instrumentation amplifiers, 4 mA-to-20 mA current-loop transmitters, multiple-limit threshold detectors, and active filters. The device is also appropriate for multiple gain blocks where four precision channels must fit into a compact analog front end.
When designing with the LT1014, check input and output voltage limits under the selected single- or dual-supply condition and provide stable bypass capacitance at the supply pins. High-impedance layouts should minimize leakage and guard sensitive input nodes, while precision measurements require resistor networks with suitable noise, tolerance, and thermal characteristics.
This page organizes the electrical characteristics, package information, drop-in alternatives, comparison data, and application guidance needed to evaluate the LT1014ISW as a precision quad operational amplifier. Use the manufacturer datasheet pin-description table when assigning PCB signals and verify the complete operating limits against the intended supply configuration.
Аналоги без доработки для LT1014ISW — тот же корпус, pin-to-pin совместимость. Компоненты в других корпусах, требующие переработки PCB, исключены.
Варианты в этой серии
Модели той же серии, совместимые без доработки с LT1014ISW (тот же форм-фактор и посадочное место) — отличается по Low-Voltage Noise, Number of Amplifiers, Package.
LT1014DSW
✅ Прямая заменаУточнить цену
Открыть даташит →LT1014DDW
✅ Прямая заменаУточнить цену
Открыть даташит →LT1014DIDWR
✅ Прямая замена📋 Справочный аналог (нет в каталоге)
TLE2144CDWR
✅ Прямая замена📋 Справочный аналог (нет в каталоге)
LT1014ISW Максимальные параметры и электрические характеристики
| Number of Amplifiers | 4 amplifiers |
| Precision | 50 µV offset voltage |
| Input Offset Voltage | 50 µV maximum |
| Input Offset Drift | 0.3 µV/°C |
| Input Offset Current | 0.15 nA |
| Open-Loop Gain | 8 million V/V |
| Common-Mode Rejection Ratio | 117 dB |
| Power-Supply Rejection Ratio | 120 dB |
| Low-Voltage Noise | 0.55 µV peak-to-peak from 0.1 Hz to 10 Hz |
| Input Current Noise | 0.07 pA/√Hz |
| Ток потребления | 500 µA maximum |
| Typical Supply Current | 350 µA |
| Supported Supply Configuration | ±15 V or single 5 V |
| Single-Supply Input Range | Input range extends to ground |
| Рабочая температура | -40 °C to +85 °C |
| Корпус | 16-lead SOIC, 2.64 mm height |
Руководство по цоколевке LT1014ISW в корпусе 16-lead soic, 2.64 mm height
Цоколевка для LT1014ISW (корпус 16-lead soic, 2.64 mm height). Этот аналоговый компонент имеет выводы входа, выхода и питания. Обратитесь к техническому описанию производителя для конфигураций выводов балансировки нуля, коррекции и разрешения. Идеально подходит для схем обработки сигналов и усилителей.
Нет подробных данных о распиновке для LT1014ISW.
Обратитесь к даташиту для полной конфигурации выводов.
Типичное применение
LT1014ISW подходит для 6 применениеs: Battery-Powered Precision Instrumentation, Strain-Gauge Signal Conditioning, Thercocouple Amplification, 4 mA to 20 mA Current-Loop Transmitters, Instrumentation Amplifier Front Ends, Active Filters and Multiple Gain Blocks.
Battery-Powered Precision Instrumentation
The LT1014ISW fits portable measurement systems because four precision amplifiers share a 16-lead SOIC package while the device supports a single 5 V supply and guarantees 500 µA maximum supply current. Its 50 µV offset voltage and 0.3 µV/°C drift help preserve accuracy as battery voltage and ambient temperature vary. Use the quad arrangement for sensor conditioning, gain stages, and active filtering while limiting board area. The principal design consideration is total system current, because sensor excitation, reference circuits, and output stages may consume more power than the amplifiers themselves.
Рекомендуется
Strain-Gauge Signal Conditioning
The LT1014ISW is appropriate for strain-gauge bridges where low offset and high common-mode rejection reduce errors in small differential signals. Its 50 µV maximum offset voltage and 117 dB CMRR provide a strong starting point for precision bridge amplifiers, while 120 dB PSRR helps isolate the measurement from supply variation. Use low-leakage board materials and guard techniques around high-impedance input nodes. The amplifier cannot remove bridge imbalance by itself, so resistor-network matching and calibration remain important parts of the measurement chain.
Рекомендуется
Thercocouple Amplification
The LT1014ISW can amplify thermocouple signals whose microvolt-level changes require low offset, low drift, and low current noise. The 50 µV maximum input offset and 0.3 µV/°C drift are meaningful relative to many temperature sensors, while 0.07 pA/√Hz current noise benefits high-impedance input arrangements. Use cold-junction compensation, input filtering, and open-circuit detection around the amplifier. Care should be taken to prevent thermocouple lead resistance and leakage from creating errors larger than the amplifier’s specified input error.
Рекомендуется
4 mA to 20 mA Current-Loop Transmitters
Analog Devices identifies current-loop transmitters as an LT1014 application, and the LT1014ISW supports this role with low offset, high CMRR, and single 5 V operation. The four amplifiers can support input conditioning, active filtering, gain stages, and output-loop drive functions. The device’s 500 µA maximum supply current is useful in transmitter designs, although the complete loop power budget also includes voltage references and output stages. The design should verify output swing, load compliance, loop resistance, and isolation requirements under the worst operating condition.
Рекомендуется
Instrumentation Amplifier Front Ends
The LT1014ISW can implement the amplifier section of a precision instrumentation front end where common-mode rejection, offset control, and low power are important. Its 8 million open-loop gain, 117 dB CMRR, and 120 dB PSRR support accurate signal amplification, while four channels can reduce component count in multi-axis or multi-sensor systems. Matched feedback resistors should be used to preserve gain accuracy, and input bias-current compensation may be required for very high source impedances. Stable reference and bypass components complete the instrumentation chain.
Рекомендуется
Active Filters and Multiple Gain Blocks
The LT1014ISW fits active-filter and multiple-gain-block designs because it provides four precision amplifiers with low offset, high open-loop gain, and low supply current. The 8 million V/V open-loop gain supports accurate closed-loop gain, while low input offset reduces DC errors in filter passbands. Use resistor and capacitor selections appropriate to the required noise, stability, and tolerance goals. Decoupling should be placed close to the supply pins, and unused amplifier channels should be configured according to the manufacturer’s recommended stability practices.
Рекомендуется
Сводка рекомендуемых товаров
Справочные инженерные данные для LT1014ISW — сравнение, рекомендации по проектированию и информация о соответствии.
Руководство по выбору
Сравнение с аналогами
| Параметр | Этот товар | LT1014DSW | LT1014DDW | LT1014DIDWR | TLE2144CDWR |
|---|---|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Texas Instruments |
| Package | 16-SO | 16-SO | 16-SO | 16-SO | 16-SO |
| Amplifier Count | 4 amplifiers | 4 amplifiers | 4 amplifiers | 4 amplifiers | 4 amplifiers |
Ключевые отличия
- Established LT1014 precision characteristics (против TLE2144CDWR)
- Four precision amplifiers in one compact package (против LM2902N/PB)
- Low-power single-supply operation (против LM324ADR)
Заметки по проектированию
Place the supply bypass capacitors immediately adjacent to the positive and negative supply pins, and keep the high-impedance input nodes away from switching nodes and long copper traces. For strain-gauge, thermocouple, and current-loop inputs, use guarding, clean insulation, and leakage-controlled board materials. The LT1014’s low current noise can be undermined if PCB contamination or humidity creates a leakage path comparable to the sensor source impedance.
Do not treat the single-supply input range extending to ground as permission for input voltages outside the absolute-maximum limits. Check the common-mode range across temperature, verify output swing under the expected load, and include adequate supply headroom for transient overshoot. Also account for input bias current when working with high source impedances; low voltage noise alone does not guarantee low total measurement error.
Use matched feedback resistors when multiple channels require consistent gain, and calculate resistor noise and thermal drift as part of the overall precision budget. The amplifier’s 50 µV maximum offset and 0.3 µV/°C drift are meaningful, but they do not remove errors caused by unequal resistor ratios, thermocouple junctions, or input bias current. Stable reference and compensation networks are especially important in precision instrumentation and current-loop transmitters.
Информация о соответствии
No explicit RoHS, REACH, lead-free, halogen-free, or conflict-minerals statement was included in the cited product information. AEC-Q100 status is not applicable because this is an analog operational amplifier rather than an automotive-qualified device.