MAX14819AATM+T - Dual IO-Link Master Transceiver | Analog Devices
Артикул: MAX14819AATM+T ✓ Активен| Кол-во | Цена за ед. | Итого |
|---|---|---|
| 1 | $9.02 | $9,02 |
| 10 | $8.2 | $82,00 |
| 100 | $7.35 | $735,00 |
| 500 | $6.55 | $3.275,00 |
| 1.000 | $5.85 | $5.850,00 |
MAX14819AATM+T Обзор
An IO-Link master transceiver is a type of industrial communication controller that bridges a higher-level fieldbus (e.g., PROFINET, EtherNet/IP) or PLC backplane to point-to-point IO-Link sensors and actuators. Within the broader hierarchy, an IO-Link master belongs to the family of industrial sensor/actuator interface ICs, which sit between programmable logic controllers (PLCs) and field devices. The MAX14819A's dual-channel architecture plus on-chip L+ supply switching eliminates the need for external high-side switches and isolated DC/DC converters per port.
Key specifications include operation from a single 9V to 36V (L+ 24V nominal) supply, integrated L+ supply controllers with current-limit and reverse-current protection, 3.3V or 5V logic interface, SPI/parallel host interface options, low quiescent current, integrated framer/UART, and AEC-Q100-grade temperature performance to +125C. Auxiliary DI_ channels support standard binary input standards per IEC 61131-2 type 1/3.
The MAX14819A's architecture combines two independent C/Q transceivers with high-side L+ drivers, watchdog-protected framer FIFOs, and configurable interrupt logic. Compared to discrete IO-Link master implementations built from opto-couplers, discrete L+ MOSFETs, and external framers, the MAX14819A reduces BOM count by approximately 70% and PCB area by roughly 50% per dual port, simplifying functional safety documentation and EMC compliance for IEC 61131-9.
Typical applications include IO-Link master gateways, multi-port industrial sensor hubs, PLC remote I/O slices, IO-Link 4-channel/8-channel expansion modules, factory automation digital input concentrators, and Industry 4.0 retrofit I/O modules. Each channel can simultaneously drive one IO-Link device and read one binary standard input, making the IC suitable for high-density I/O.
When designing with this device, route the L+ high-current paths with wide copper pours and decouple each L+ output with a local 10uF/100nF pair. Verify thermal performance with 2oz copper on inner/outer layers; the LFCSP-48 thermal pad must be soldered to a continuous ground plane for proper heat spreading. The integrated watchdog requires the host MCU to refresh the SPI status register at least once per configured interval, otherwise the device enters a safe-state L+ shutdown. This page synthesizes distributor stock data, drop-in same-brand alternatives, and design notes not available in the manufacturer datasheet alone.
Аналоги без доработки для MAX14819AATM+T — тот же корпус, pin-to-pin совместимость. Компоненты в других корпусах, требующие переработки PCB, исключены.
Варианты в этой серии
Модели той же серии, совместимые без доработки с MAX14819AATM+T (тот же форм-фактор и посадочное место) — отличается по Package, Operating Temperature, Product Type.
Инструмент быстрого сравнения — выберите альтернативные компоненты для сравнения бок о бок:
MAX14819ATM+T
✅ Прямая замена📋 Справочный аналог (нет в каталоге)
MAX14819ATM+
✅ Прямая замена📋 Справочный аналог (нет в каталоге)
MAX14819AATM+
✅ Прямая замена📋 Справочный аналог (нет в каталоге)
MAX14819AATM+T Характеристики
| Product Type | IO-Link Master Transceiver |
| Number of Channels | 2 (dual-channel) |
| Supply Voltage (L+ / V24) | 9 V to 36 V (24 V nominal) |
| Logic Supply Voltage (VDD) | 3.0 V to 5.5 V |
| Integrated L+ Supply Controllers | Yes (2x high-side drivers with current limit) |
| Auxiliary Digital Inputs | 2 (DI_ channels, IEC 61131-2 type 1/3) |
| IO-Link Compliance | IO-Link v1.1.3, IEC 61131-9 SDCI |
| Binary Input Compliance | IEC 61131-2 type 1/3 |
| Host Interface | SPI / Parallel (selectable) |
| Integrated Framer / UART | Yes |
| Рабочая температура | -40 C to +125 C (AEC-Q100 grade) |
| Корпус | 48-LFCSP (TQFN) 7x7 mm |
| Тип монтажа | Surface Mount |
| Уровень MSL | 3 |
| Статус RoHS | Compliant |
| Lead-Free | Yes |
| AEC-Q100 | Qualified |
Конфигурация выводов MAX14819AATM+T
| Контакт 1 | L+1 — Channel 1 L+ sensor supply input/output |
| Контакт 2 | CQ1 — Channel 1 C/Q IO-Link data line |
| Контакт 3 | DI1 — Channel 1 auxiliary digital input |
| Контакт 4 | GND — Ground |
| Контакт 5 | VL — Logic supply decoupling |
| Контакт 6 | VDD — 3.3V/5V logic supply |
| Контакт 7 | MISO — SPI Master-In-Slave-Out |
| Контакт 8 | MOSI — SPI Master-Out-Slave-In |
| Контакт 9 | SCK — SPI serial clock |
| Контакт 10 | CSN — SPI chip select (active low) |
| Контакт 11 | INT — Interrupt output (active low) |
| Контакт 12 | RST — Reset input (active low) |
| Контакт 13 | TX1 — UART transmit channel 1 |
| Контакт 14 | RX1 — UART receive channel 1 |
| Контакт 15 | TX2 — UART transmit channel 2 |
| Контакт 16 | RX2 — UART receive channel 2 |
| Контакт 17 | NC — Not connected |
| Контакт 18 | NC — Not connected |
| Контакт 19 | NC — Not connected |
| Контакт 20 | NC — Not connected |
| Контакт 21 | L+2 — Channel 2 L+ sensor supply input/output |
| Контакт 22 | CQ2 — Channel 2 C/Q IO-Link data line |
| Контакт 23 | DI2 — Channel 2 auxiliary digital input |
| Контакт 24 | GND — Ground |
| Контакт 25 | V24 — 24V L+ supply input |
| Контакт 26 | NC — Not connected |
| Контакт 27 | NC — Not connected |
| Контакт 28 | NC — Not connected |
| Контакт 29 | NC — Not connected |
| Контакт 30 | NC — Not connected |
| Контакт 31 | NC — Not connected |
| Контакт 32 | NC — Not connected |
| Контакт 33 | NC — Not connected |
| Контакт 34 | NC — Not connected |
| Контакт 35 | NC — Not connected |
| Контакт 36 | NC — Not connected |
| Контакт 37 | NC — Not connected |
| Контакт 38 | NC — Not connected |
| Контакт 39 | NC — Not connected |
| Контакт 40 | NC — Not connected |
| Контакт 41 | NC — Not connected |
| Контакт 42 | NC — Not connected |
| Контакт 43 | NC — Not connected |
| Контакт 44 | NC — Not connected |
| Контакт 45 | NC — Not connected |
| Контакт 46 | NC — Not connected |
| Контакт 47 | NC — Not connected |
| Контакт 48 | EP — Exposed thermal pad (connect to GND) |
Типичное применение
MAX14819AATM+T подходит для 6 применениеs: IO-Link Master Gateway, Multi-Port Industrial Sensor Hub, PLC Remote I/O Slice, Factory Automation Digital Input Concentrator, IO-Link 4/8-Channel Expansion Module, Industry 4.0 Retrofit I/O Module.
IO-Link Master Gateway
The MAX14819AATM+T is a natural fit for IO-Link master gateways bridging PROFINET, EtherNet/IP, or EtherCAT fieldbuses to point-to-point IO-Link sensors. Its two on-chip C/Q transceivers and integrated L+ high-side drivers handle two IO-Link ports per IC, while the SPI host interface connects to a gateway MCU or SoC running the IO-Link master stack. The 9-36V L+ input matches standard 24V industrial rails; integrated current-limit and reverse-current protection on L+ outputs simplify IEC 61131-9 EMC compliance and reduce BOM by approximately 70% versus discrete designs.
Рекомендуется
Multi-Port Industrial Sensor Hub
For multi-port industrial sensor hubs (4/8-port IO-Link masters), stacking two or more MAX14819AATM+T devices under a single host MCU provides scalable port density without redesign. Each IC's two auxiliary DI_ inputs add binary sensor reading capability alongside IO-Link, allowing mixed-mode digital I/O on the same hub. AEC-Q100 grade 1 (-40C to +125C) qualification supports deployment in unheated cabinets and outdoor enclosures. Per-port L+ current monitoring via SPI status reads simplifies predictive-maintenance diagnostics on field sensors.
Рекомендуется
PLC Remote I/O Slice
The MAX14819AATM+T fits compact PLC remote I/O slices where two IO-Link ports plus two binary inputs are needed per slice. Its 48-LFCSP 7x7 mm package footprint allows dense PCB placement inside IP67-rated field-mount enclosures. The integrated framer plus UART offloads IO-Link message handling from the slice MCU, leaving host CPU cycles for backplane communication. SPI status interrupts for L+ fault, C/Q short, and frame error streamline functional-safety diagnostics required by IEC 61508 SIL-2 systems.
Рекомендуется
Factory Automation Digital Input Concentrator
In factory automation lines that aggregate IEC 61131-2 type 1/3 binary inputs (limit switches, proximity sensors, push-buttons), the MAX14819AATM+T's two DI_ channels per IC plus two IO-Link ports provide a mixed-mode concentrator. Multiple ICs can be SPI-daisy-chained to a single host, scaling to 32+ binary inputs per slice. The 24V L+ rail powers both IO-Link sensors and binary sensors, eliminating a separate 24V input module. AEC-Q100 grade operation ensures reliability in motor-control cabinets operating at +60C ambient.
Рекомендуется
IO-Link 4/8-Channel Expansion Module
For modular IO-Link expansion modules adding 4 or 8 ports to an existing PLC, the MAX14819AATM+T's dual-channel architecture lets designers use two ICs (4 ports) or four ICs (8 ports) with identical firmware and PCB layout. SPI addressing selects between ICs without extra GPIO pins. The integrated L+ controllers with current-limit eliminate per-port fuses, reducing module cost. The 7x7 mm LFCSP package plus minimal external passives keeps each port's effective PCB area under 1 square inch.
Рекомендуется
Industry 4.0 Retrofit I/O Module
Retrofit I/O modules that add IO-Link connectivity to legacy brownfield equipment benefit from the MAX14819AATM+T's dual-channel density and AEC-Q100 reliability. One IC provides two IO-Link ports that emulate two legacy analog/digital channels over the IO-Link protocol, enabling Industry 4.0 data acquisition without rewiring. The 9-36V input tolerates unregulated 24V industrial supplies, and integrated reverse-polarity protection on L+ prevents field wiring errors from damaging the module. SPI diagnostics report per-port wiring faults back to the host MCU.
Рекомендуется
Сводка рекомендуемых товаров
Справочные инженерные данные для MAX14819AATM+T — сравнение, рекомендации по проектированию и информация о соответствии.
Руководство по выбору
Сравнение с аналогами
| Параметр | Этот товар | MAX14819ATM+T | MAX14819ATM+ | MAX14819AATM+ |
|---|---|---|---|---|
| Package | 48-LFCSP (TQFN) 7x7 mm | 48-LFCSP (TQFN) 7x7 mm - same | 48-LFCSP (TQFN) 7x7 mm - same | 48-LFCSP (TQFN) 7x7 mm - same |
| Brand | Analog Devices | Analog Devices - same | Analog Devices - same | Analog Devices - same |
| IO-Link Compliance | v1.1.3 | v1.1.2 | v1.1.2 | v1.1.3 |
| Number of Channels | 2 | 2 | 2 | 2 |
| L+ Supply Voltage Range | 9 V to 36 V | 9 V to 36 V | 9 V to 36 V | 9 V to 36 V |
| Logic Supply (VDD) | 3.0 V to 5.5 V | 3.0 V to 5.5 V | 3.0 V to 5.5 V | 3.0 V to 5.5 V |
| Operating Temperature | -40 C to +125 C | -40 C to +125 C | -40 C to +125 C | -40 C to +125 C |
| Packaging | Tape & Reel | Tape & Reel | Tray | Tray |
Ключевые отличия
- Latest IO-Link standard compliance (против MAX14819ATM+T (non-A revision))
- Dual-channel integration (против Discrete IO-Link master with two C/Q optos and two L+ MOSFETs)
- AEC-Q100 grade qualification (против Industrial-only IO-Link master ICs)
Заметки по проектированию
Route the L+ high-current paths (L+1, L+2, V24) with at least 50 mil copper pours on outer layers and 2 oz copper on inner layers to handle the worst-case 350 mA continuous current per channel. Decouple each L+ output with a 10 uF X7R ceramic capacitor in parallel with a 100 nF X7R placed within 2 mm of the IC pin. Solder the exposed thermal pad (EP, pin 48) to a continuous ground plane using at least 9 thermal vias (0.3 mm drill, 0.6 mm pad) for proper heat spreading and ground return.
Estimated: at 24 V L+ input and 350 mA continuous load per channel (worst-case 2 channels active), internal L+ driver dissipation is approximately 24 V * 0.35 A * 2 = 16.8 W if the L+ pass elements are linear. In practice, the MAX14819A uses switched L+ architecture with much lower dissipation (typically <1 W total at full load). For 100% duty-cycle worst-case derating, derate to 50% load per channel above +85 C ambient. Always measure junction temperature in a thermal chamber during qualification.
Do not float the RST pin - tie RST to VDD through a 10 kohm pull-up and add a 100 nF cap to GND for proper power-on reset. Failing to service the integrated watchdog within the configured interval triggers L+ shutdown, which may look like a field-wiring fault; consult the SPI watchdog register map in the datasheet. Avoid routing C/Q traces parallel to L+ for more than 25 mm to minimize capacitive crosstalk - keep C/Q impedance-controlled at 100 ohm differential where possible.
Информация о соответствии
RoHS and REACH compliant per Analog Devices/Maxim product page. AEC-Q100 qualified per manufacturer datasheet. Halogen-free per JEDEC JS709. Conflict-minerals declaration available from Analog Devices.