MAX202EEWE-T - 2/2 120kbps RS-232 Transceiver | Maxim
Артикул: MAX202EEWE-T ✓ АктивенMAX202EEWE-T Обзор
An RS-232 transceiver is an interface IC that bridges a logic-level UART or other serial controller and a physical RS-232 port. It combines line drivers, which convert low-voltage logic signals into RS-232 levels, with receivers, which convert bipolar RS-232 signals back into logic levels. Within the hierarchy of interface ICs, it is a dedicated serial-interface transceiver for point-to-point industrial, instrumentation, and embedded communications.
The MAX202EEWE-T provides two transmit channels and two receive channels, allowing full-duplex RS-232 communication from one package. Its maximum specified data rate of 120 kbps covers legacy serial links, industrial equipment, barcode systems, and control interfaces. Operation from a single 5 V supply simplifies system power design because the integrated charge pump generates the negative voltage required by the RS-232 drivers.
The device's integrated charge pump and single-supply architecture eliminate the external negative rail and associated charge-pump capacitors normally required by discrete RS-232 interface designs. Its 16-pin SOIC package is a surface-mount package in the SOIC family, and the EWE ordering code identifies the wide SOIC, tape-and-reel configuration. A complete 16-pin pin description is required before assigning PCB tracks or confirming connector-side signal names.
Typical uses include RS-232 links between microcontrollers and industrial peripherals, test and measurement instruments, service consoles, security equipment, and legacy data-acquisition systems. The two-driver, two-receiver arrangement is particularly useful for full-duplex links that carry data in both directions through one RS-232 port.
For PCB implementation, keep the supply bypass capacitor close to the V+ and ground connections, route driver and receiver outputs away from sensitive low-level signals, and treat the exposed connector-side pins as harsh industrial environments. The ±15 kV HBM rating provides useful device protection, but it does not eliminate the need for system-level surge and ESD mitigation.
This page combines the manufacturer interface specifications, ordering-code details, practical PCB guidance, and verified drop-in alternatives. It also identifies where pinout, package quantity, and compliance details require confirmation from the official MAX202E datasheet before production release.
Аналоги без доработки для MAX202EEWE-T — тот же корпус, pin-to-pin совместимость. Компоненты в других корпусах, требующие переработки PCB, исключены.
Варианты в этой серии
Модели той же серии, совместимые без доработки с MAX202EEWE-T (тот же форм-фактор и посадочное место) — отличается по Mounting Type, Nominal Supply Voltage.
MAX202EWE+T
✅ Прямая заменаУточнить цену
Открыть даташит →MAX202ECWE+T
✅ Прямая заменаУточнить цену
Открыть даташит →TRS202E
✅ Прямая замена📋 Справочный аналог (нет в каталоге)
MAX202EEWE-T Характеристики
| Driver/Receiver Configuration | 2 drivers / 2 receivers |
| Transceiver Type | 2/2 full-duplex RS-232 transceiver |
| Maximum Data Rate | 120 kbps |
| Supply Voltage Range | 4.5 V to 5.5 V |
| Nominal Supply Voltage | 5 V |
| ESD Protection | ±15 kV HBM |
| Interface Standard | EIA/TIA-232E and CCITT V.28 |
| Integrated Charge Pump | Yes |
| Корпус | 16-pin wide SOIC |
| Package Width | 7.50 mm |
| Тип монтажа | Surface-mount SMD |
| Packaging | Tape and reel |
Руководство по цоколевке MAX202EEWE-T в корпусе 7.50 mm
Цоколевка для MAX202EEWE-T (корпус 7.50 mm). Нумерация выводов, функции и схемы подключения определены в техническом описании производителя. Обратитесь к нему для точного посадочного места и рекомендаций по пайке.
Нет подробных данных о распиновке для MAX202EEWE-T.
Обратитесь к даташиту для полной конфигурации выводов.
Типичное применение
MAX202EEWE-T подходит для 6 применениеs: Industrial Controller Serial Port, Test and Measurement Instrument, Service Console and Configuration Port, Embedded Data Acquisition Unit, Security and Access Equipment, Legacy Serial Adapter.
Industrial Controller Serial Port
The MAX202EEWE-T is appropriate for an industrial controller that must communicate with a legacy RS-232 instrument over a full-duplex link. Its two drivers and two receivers provide balanced channel count for bidirectional traffic, while the 120 kbps maximum data rate covers many UART-based control protocols. Single 5 V operation is useful where a negative rail would otherwise require a charge-pump circuit. The manufacturer rates the interface for EIA/TIA-232E and CCITT V.28 operation and includes ±15 kV HBM ESD protection. In a finished controller, add connector-side surge protection and maintain a low-impedance ground path between the transceiver and the connected equipment.
Рекомендуется
Test and Measurement Instrument
The MAX202EEWE-T can provide the host-side RS-232 interface in test and measurement equipment that uses an asynchronous serial command set. The 2/2 channel arrangement supports transmit and receive paths within one device, and the 120 kbps capability is suitable for many instrument-control protocols operating below that limit. Because the device needs only a 5 V supply, instrument designers can avoid a separate negative RS-232 rail. The integrated charge pump and ±15 kV HBM protection are valuable in benchtop and production-test environments where the serial connector is handled frequently, although external protection may still be needed for surge events.
Рекомендуется
Service Console and Configuration Port
The MAX202EEWE-T fits a service console or configuration interface that must connect a controller board to a computer or maintenance terminal. Two drivers and two receivers allow full-duplex command and response traffic, while the 120 kbps rate is compatible with many legacy serial consoles. Its single 5 V supply requirement simplifies auxiliary interface design in systems that already operate from 5 V. The 16-pin wide SOIC package is also practical for automated board assembly. Place the interface close to the connector, keep ground return paths short, and use appropriate external protection when the cable can be connected or disconnected during operation.
Рекомендуется
Embedded Data Acquisition Unit
The MAX202EEWE-T can serve as the RS-232 interface on an embedded data-acquisition unit that must exchange commands and sampled data with a host computer. The 120 kbps ceiling provides ample bandwidth for many low-rate telemetry protocols and avoids the complexity of a modern high-speed physical layer. The integrated charge pump removes the need for an external negative voltage generator, while the device's 2/2 organization supports simultaneous transmit and receive paths. For deployments near motors, relays, or long external cables, add coordinated grounding and connector-side surge protection because device ESD ratings do not by themselves suppress system-level transients.
Рекомендуется
Security and Access Equipment
The MAX202EEWE-T is suitable for access-control and security equipment that exposes a wired RS-232 configuration or status port to a technician's terminal. The device provides the required EIA/TIA-232E and CCITT V.28 interface behavior at rates up to 120 kbps, along with ±15 kV HBM ESD protection for handling-sensitive environments. Its integrated charge pump and single 5 V operation reduce the number of power rails required beside the controller. The final enclosure should still define cable length, grounding, and surge requirements, because the transceiver rating addresses device-level ESD immunity rather than complete protection of the external port.
Рекомендуется
Legacy Serial Adapter
The MAX202EEWE-T can be used in a compact legacy serial adapter that converts a modern controller connector to an RS-232 port. The 16-pin wide SOIC package supports compact surface-mount construction, while two drivers and two receivers enable a full-duplex interface. Operation from 4.5 V to 5.5 V provides flexibility around common 5 V systems, and the integrated charge pump supplies the interface voltage needed by RS-232 drivers. At the board boundary, include a defined signal ground, route outputs away from sensitive logic, and select external protection according to the maximum cable exposure and installation environment.
Рекомендуется
Сводка рекомендуемых товаров
Справочные инженерные данные для MAX202EEWE-T — сравнение, рекомендации по проектированию и информация о соответствии.
Руководство по выбору
Сравнение с аналогами
| Параметр | Этот товар | MAX202EWE+T | MAX202ECWE+T | TRS202E |
|---|---|---|---|---|
| Package | 16-SOIC wide | 16-SOIC wide | 16-SOIC wide | 16-SOIC |
| Brand | Maxim Integrated | Maxim Integrated | Maxim Integrated | Texas Instruments |
| Driver/Receiver Configuration | 2/2 | 2/2 | 2/2 | 2/2 |
| Maximum Data Rate | 120 kbps | 120 kbps | 120 kbps | 120 kbps |
| Supply Voltage Range | 4.5 V to 5.5 V | 4.5 V to 5.5 V | 4.5 V to 5.5 V | 4.5 V to 5.5 V |
| Single-Supply Operation | Yes | Yes | Yes | Yes |
| ESD Protection | ±15 kV HBM | ±15 kV HBM | ±15 kV HBM | Enhanced IEC61000-4-2 ESD protection |
| Interface Standards | EIA/TIA-232E and CCITT V.28 | EIA/TIA-232E and CCITT V.28 | EIA/TIA-232E and CCITT V.28 | RS-232 / V.28 |
| Integrated Charge Pump | Yes | Yes | Yes | Yes |
Ключевые отличия
- Full-duplex 2/2 RS-232 channel arrangement (против TRS202E)
- 120 kbps RS-232 operation from a single 5 V supply (против MAX202EWE+T)
- Manufacturer-specified ±15 kV HBM ESD protection (против TRS202E)
Заметки по проектированию
Place the local 5 V bypass capacitor as close as practical to the device supply and ground pins. The MAX202EEWE-T operates from 4.5 V to 5.5 V and uses an integrated charge pump, so the external supply network must provide a low-impedance 5 V rail while keeping switching and digital currents away from the analog reference return. Verify capacitor voltage rating, effective capacitance after DC-bias derating, and trace resistance against the load transient requirements of the finished interface.
Use the official 16-pin pin-description table when laying out the wide SOIC footprint. Do not infer connector-side signal names from a narrow SOIC or TSSOP variant because the package drawings may place the same functional signals on different pins. Keep driver outputs and receiver inputs away from clocks, reset signals, and precision analog traces. Provide a direct ground return to the connector reference where possible, and keep the RS-232 traces short relative to the external cable.
The MAX202EEWE-T provides ±15 kV HBM device-level ESD protection, but a cable-connected interface can also experience system-level surges and discharges that exceed that rating. Add a connector-side protection network when the port is accessible, selected for the data rate, line impedance, and installation environment. Keep the protected connector section physically separate from sensitive logic and route surge current directly to chassis or signal ground according to the product's grounding strategy.
Do not treat every MAX202E suffix as electrically and mechanically interchangeable. The wide SOIC, narrow SOIC, and TSSOP order codes have different footprints, and reel or temperature suffixes can change how the component is ordered. Before substitution, verify the exact package width, pin count, pin names, temperature grade, and lifecycle status. For a board already laid out for the MAX202EEWE-T, compare the candidate directly against the official pin table rather than relying only on the family name.
Информация о соответствии
The interface supports EIA/TIA-232E and CCITT V.28 and has ±15 kV HBM ESD protection. Specific RoHS, REACH, lead-free, halogen-free, and conflict-minerals declarations require confirmation from the manufacturer product page or declaration.