NXP Semiconductors

MPVZ5150GC7U - 150kPa Vented Gauge Pressure Sensor | NXP

Артикул: MPVZ5150GC7U ✓ Активен
В наличии Отправка в течение 1–3 рабочих дней
0.2 V to 4.7 V Vdss 8-DIP (Case 867F, 10.67 x 10.67 x 12.96 mm) Package
От $8.64 USD / шт.
MOQ: 1 |
Цена обновлена: 2026-10-15
Оптовые цены
Кол-во Цена за ед. Итого
1 $13.5 $13,50
10 $12.15 $121,50
100 $10.8 $1.080,00
500 $9.72 $4.860,00
1.000 $8.64 $8.640,00
ℹ️ Все цены указаны в USD

MPVZ5150GC7U Обзор

The NXP MPVZ5150GC7U is an integrated silicon pressure sensor with on-chip signal conditioning, temperature compensation, and calibration, designed for a wide range of microcontroller and microprocessor applications. Housed in an 8-pin DIP (Case 867F) package, it provides an analog output of 0.2 V to 4.7 V proportional to applied pressure over a 0 to 150 kPa (0 to 21.76 PSI) vented gauge range, with a top-port male 0.13" (3.17 mm) tube interface.

A piezoresistive transducer, also called a MEMS pressure sensor or silicon strain-gauge sensor, is a device that converts applied pressure into a small differential voltage using diffused resistors on a silicon diaphragm. The on-chip ASIC conditions this raw signal, applies temperature compensation across the -40 °C to +125 °C range, and normalizes the output so the device produces a near-linear analog voltage directly readable by an MCU ADC.

Key features include ±1.5 % maximum pressure accuracy over 0 °C to 85 °C, an ratiometric analog output proportional to a 4.75 V to 5.25 V supply, and a typical response time of 1.0 ms. The 8-DIP through-hole package (10.67 x 10.67 x 12.96 mm) simplifies prototyping and breadboarding, while the integrated calibration eliminates external compensation components. The device also provides ESD protection rated above 1000 V HBM on sensor pins per industry test methods.

Typical applications include HVAC pressure monitoring, medical respiratory equipment, weather stations, altimeters, industrial process control, and appliance water-level sensing. Because the output spans nearly the full 0-5 V ADC range of most 5 V microcontrollers, no external amplifier is needed in many designs. The vented gauge reference makes it ideal for applications where barometric compensation is desired, such as portable altimeters and weather instruments.

When designing with this part, add a 0.01 µF to 0.1 µF decoupling capacitor close to VDD, and consider a low-pass RC filter on VOUT if the host ADC is sensitive to high-frequency noise. Avoid liquids contacting the silicone gel coating inside the port, and route the supply trace away from switching nodes to preserve the ratiometric accuracy.

Аналоги без доработки для MPVZ5150GC7U — тот же корпус, pin-to-pin совместимость. Компоненты в других корпусах, требующие переработки PCB, исключены.

Варианты в этой серии

Модели той же серии, совместимые без доработки с MPVZ5150GC7U (тот же форм-фактор и посадочное место) — отличается по Media Compatibility, Mounting Type, Operating Pressure Range, Output Type, Supply Voltage.

NXP Semiconductors
Media Compatibility: Dry non-corrosive gases (reference port vented to ambient)
Mounting Type: Through-Hole
Operating Pressure Range: 0 kPa to 10 kPa (0 PSI to 1.45 PSI)
Сравнить с MPVZ5150GC7U →
NXP Semiconductors
Media Compatibility: Non-corrosive, non-ionic media (dry air, dry gases)
Mounting Type: Surface Mount
Operating Pressure Range: 0 kPa to 10 kPa
Сравнить с MPVZ5150GC7U →

Инструмент быстрого сравнения — выберите альтернативные компоненты для сравнения бок о бок:

MPVZ5150GC6T1

✅ Прямая замена
📦 8-DIP (Case 867F)
same die, same package, same 0-150 kPa, 0.2-4.7 V output; T1 = tape & reel, U = tube

📋 Справочный аналог (нет в каталоге)

MPVZ5150GC6U

✅ Прямая замена
📦 8-DIP (Case 867F)
same die, tube version of the C7U part; identical electrical specs

📋 Справочный аналог (нет в каталоге)

MPXV5010GC7U

✅ Прямая замена
NXP Semiconductors
📦 8-DIP (Case 867F)
Differential / Gauge · 0 kPa to 10 kPa · 4.75 V to 5.25 V (typ. 5.0 V) · 4.5 V · 0.2 V to 0.85 V · 0 °C to +85 °C

✓ В наличии

$10.05 / шт.

Открыть даташит →

MPXV10GC7U

✅ Прямая замена
NXP Semiconductors
📦 8-DIP (Case 867F)
Vented Gauge · 0 kPa to 10 kPa (0 PSI to 1.45 PSI) · Analog Wheatstone Bridge (uncompensated mV) · 0 mV to 35 mV at 3 V supply · 3.5 mV/kPa nominal · 3 V to 6 V (3 V typical excitation)

✓ В наличии

$6.1 / шт.

Открыть даташит →

MPXV7002GC7U

✅ Прямая замена
📦 8-DIP (Case 867F)
bipolar +/-2 kPa differential vs 0-150 kPa gauge; pin-compatible 8-DIP

📋 Справочный аналог (нет в каталоге)

MPVZ5150GC7U Максимальные параметры и электрические характеристики

Pressure Type Vented Gauge
Operating Pressure Range 0 kPa to 150 kPa (0 PSI to 21.76 PSI)
Тип выхода Analog Voltage (ratiometric)
Диапазон выходного напряжения 0.2 V to 4.7 V
Напряжение питания 4.75 V to 5.25 V
Pressure Accuracy ±1.5 % (0 °C to 85 °C)
Рабочая температура -40 °C to +125 °C
Response Time 1.0 ms (typical)
Port Style Top Port, Male 0.13" (3.17 mm) Tube
Корпус 8-DIP (Case 867F, 10.67 x 10.67 x 12.96 mm)
Тип монтажа Through Hole
Статус RoHS Compliant
Technology Piezoresistive (MEMS) with ASIC signal conditioning
Media Compatibility Dry air and non-corrosive gases (silicone gel isolation)

Конфигурация выводов MPVZ5150GC7U

DIP-8 Package Pinout Diagram DIP-8 8-pin dual inline, 7.62mm pitch, JEDEC MS-001. 1 8 2 7 3 6 4 5 DIP-8
Контакт 1 VOUT — Analog ratiometric output voltage (0.2 V to 4.7 V)
Контакт 2 GND — Common ground
Контакт 3 VDD — Positive supply voltage (4.75 V to 5.25 V)
Контакт 4 NC — Not connected (per datasheet)
Контакт 5 NC — Not connected (per datasheet)
Контакт 6 NC — Not connected (per datasheet)
Контакт 7 NC — Not connected (per datasheet)
Контакт 8 NC — Not connected (per datasheet)

Типичное применение

MPVZ5150GC7U подходит для 6 применениеs: Barometric Weather Stations, HVAC Airflow & Duct Monitoring, Medical Respiratory Equipment, Industrial Process Pressure Monitoring, Portable Altimeters & Handheld Instruments, Appliance Water-Level Sensing (Pneumatic Method).

🌐

Barometric Weather Stations

The MPVZ5150GC7U's 0 to 150 kPa vented gauge range matches the barometric pressure envelope (typically 87 to 108 kPa at sea level) with full scale headroom. Its 0.2 V to 4.7 V ratiometric output drives a 5 V MCU ADC directly, providing approximately 4.5 mV/Pa of usable resolution. The vented gauge reference means the back of the die equalizes to ambient pressure through the port, so no separate barometric correction is needed when the enclosure is also vented to atmosphere.

🏭

HVAC Airflow & Duct Monitoring

In HVAC duct pressure monitoring the MPVZ5150GC7U delivers 0.2 V to 4.7 V for 0 to 150 kPa, well above the typical 0 to 2.5 kPa duct static pressure range, giving the ADC ample resolution at the low end. The 1 ms response time tracks fan-induced pressure fluctuations, while the integrated temperature compensation holds ±1.5 % accuracy across the 0 to 85 °C control-loop range. The top-port tube inlet connects directly to a pitot or static pressure probe without tubing adapters.

💊

Medical Respiratory Equipment

The MPVZ5150GC7U's ±1.5 % accuracy over 0 °C to 85 °C and 1 ms response support breath-cycle pressure sensing in CPAP, ventilator, and spirometer designs within the 0 to 150 kPa range. The silicone-gel isolation protects the die from exhaled humidity and condensate. The ratiometric 0.2 V to 4.7 V output can drive the ADC of an ARM Cortex-M medical MCU. Compliance documentation for medical use is the integrator's responsibility, not the component vendor's.

🏭

Industrial Process Pressure Monitoring

The MPVZ5150GC7U handles non-corrosive industrial gases up to 150 kPa with on-chip calibration, making it well matched to factory pneumatic lines, filter-status indicators, and tank-head pressure monitoring. The 8-DIP through-hole package simplifies hand-soldered prototypes and field replacements, and the -40 °C to +125 °C operating range covers most indoor industrial environments. The output is ratiometric to VDD, so drift in the 5 V supply scales both VDD and VOUT together, keeping calibration intact.

📱

Portable Altimeters & Handheld Instruments

The MPVZ5150GC7U's 0 to 150 kPa range covers the full atmospheric envelope from sea level to about 12 km altitude, where barometric pressure drops to ~20 kPa. The vented gauge reference means the sensor subtracts weather-driven pressure changes automatically when used in an altitude-hold application, simplifying firmware. Battery-powered designs benefit from the modest 5 V supply current, and the 8-DIP through-hole package simplifies hand assembly for low-volume handheld runs.

⚡

Appliance Water-Level Sensing (Pneumatic Method)

In pneumatic water-level sensors, a tube routed to the bottom of a tank delivers trapped air pressure to the MPVZ5150GC7U proportional to water column. With 150 kPa full scale, the sensor can measure water columns up to about 15 m, covering most residential appliance and small-tank use cases. The silicone-gel isolation protects the die from occasional condensation. The vented gauge configuration requires the sensor housing to be at atmospheric pressure, achieved through the top-port vent path.

Сводка рекомендуемых товаров

MPL3115A2 Companion digital altimeter/barometer for redundancy Используется в: Barometric Weather Stations, Medical Respiratory Equipment, Portable Altimeters & Handheld Instruments MMA8451F3L Tilt/temperature sensor in weather station housing Используется в: Barometric Weather Stations, HVAC Airflow & Duct Monitoring, Industrial Process Pressure Monitoring, Portable Altimeters & Handheld Instruments, Appliance Water-Level Sensing (Pneumatic Method) MPXV5010GC7U NXP Semiconductors Используется в: HVAC Airflow & Duct Monitoring, Appliance Water-Level Sensing (Pneumatic Method) MPXV7002GC7U Differential low-pressure sensor for flow element Используется в: Medical Respiratory Equipment MPX4250AP NXP Semiconductors Используется в: Industrial Process Pressure Monitoring
What is the operating pressure range of the MPVZ5150GC7U?
The MPVZ5150GC7U measures pressure from 0 kPa to 150 kPa (0 to 21.76 PSI) in a vented gauge configuration. According to the NXP datasheet, the transducer output spans 0.2 V at 0 kPa to 4.7 V at 150 kPa, giving a sensitivity of approximately 30 mV/kPa over the compensated range. Vented gauge means the back side of the die references ambient barometric pressure, so the reading naturally compensates for weather changes.
What is the output voltage range of the MPVZ5150GC7U?
The MPVZ5150GC7U output voltage ranges from 0.2 V to 4.7 V for pressures between 0 kPa and 150 kPa. The output is ratiometric, meaning it scales proportionally with the 4.75 V to 5.25 V supply voltage. This allows the device to be interfaced directly with 5 V microcontrollers and ADCs without an external amplifier. Designers should budget for the 0.2 V offset when computing low-pressure readings.
Where can I buy the MPVZ5150GC7U online?
The MPVZ5150GC7U is in stock at DigiKey (DigiKey part 2513455) and Mouser as of 2026-10-15, with same-day shipping available from both authorized distributors. Pricing scales down to approximately $8.64 per unit at 1000-piece quantities. The part is also listed at Hotenda and through Rochester Electronics for longer-term supply. XAIPART offers stock at $13.50 for prototype quantities.
What is the price of the MPVZ5150GC7U in 2026?
The MPVZ5150GC7U is priced at approximately $13.50 per unit at qty-1 as of 2026-10-15, with volume pricing dropping to $8.64 per unit at 1000-piece quantity. The MPVZ5150 family has held stable pricing for several years because NXP maintains the design and the through-hole 8-DIP package requires no exotic tooling. For OEM pricing beyond 5k units, request a quote from NXP franchised distributors.
What is the lead time for the MPVZ5150GC7U?
The MPVZ5150GC7U is currently in active production with no lead-time warnings as of 2026-10-15. DigiKey lists it as ships-today for small quantities, and Mouser maintains stock across most volume breaks. NXP does not list a PCN or EOL notice for the MPVZ5150 family. For high-volume commitments (10k+), contact NXP sales to lock a 12-month supply agreement.
What is the difference between MPVZ5150GC7U and MPXV5010GC7U?
The MPVZ5150GC7U measures 0 to 150 kPa (0 to 21.76 PSI), while the MPXV5010GC7U measures 0 to 10 kPa (0 to 1.45 PSI) - a 15:1 range difference. Both share the same Case 867F 8-DIP package and pinout, making them mechanical drop-in alternatives if your application can accept either pressure range. The MPXV5010GC7U is preferable for very low-pressure differential sensing such as HVAC duct airflow.
What is the difference between MPVZ5150GC7U and MPXV10GC7U?
The MPVZ5150GC7U measures 0 to 150 kPa vented gauge, while the MPXV10GC7U measures 0 to 10 kPa (0 to 1.45 PSI) in the same 8-DIP Case 867F package. For typical barometric and weather-station use the MPVZ5150GC7U is the right choice, while MPXV10GC7U suits very low-pressure airflow or vacuum sensing. Both are pin-compatible, but the output scaling differs - choose based on the maximum pressure in your system, not connector preference.
When should I choose MPVZ5150GC7U over MPXV5010GC7U?
Choose the MPVZ5150GC7U when your system pressure exceeds 10 kPa, such as barometric measurement, weather instruments, or industrial pneumatic monitoring up to 150 kPa. Choose the MPXV5010GC7U when measuring low differential pressure such as HVAC duct airflow, respirator flow, or cleanroom pressure, where the higher resolution of the 10 kPa range provides better ADC counts per Pascal. Both share the 8-DIP package and pinout, so the same PCB can host either sensor.
What is the best drop-in replacement for MPVZ5150GC7U?
The closest drop-in replacement for the MPVZ5150GC7U is the MPVZ5150GC6T1, which is the same die in the same 8-DIP Case 867F package with the same 0 to 150 kPa range and 0.2 V to 4.7 V output. The "T1" suffix denotes tape-and-reel packaging for high-volume assembly, while "C7U" denotes the tube/rail variant for prototyping. Both carry identical electrical specifications and share the same datasheet, so they are functionally interchangeable.
What cross-brand equivalent exists for MPVZ5150GC7U?
There is no widely-recognized cross-brand drop-in equivalent for the MPVZ5150GC7U at the 0 to 150 kPa vented gauge range in the 8-DIP Case 867F package. Honeywell and TE Connectivity offer similar analog-output pressure sensors, but they require different packages, port styles, or supply voltages. For a true pin-compatible cross-brand alternative, the closest match is the Honeywell 26PC series, which uses a different DIP pinout and would require PCB rework.
Where can I download the MPVZ5150GC7U datasheet PDF?
The official MPVZ5150GC7U datasheet is available as a free PDF download from NXP at https://www.nxp.com/mcds/MPVZ5150GC7U.pdf, or via the product family datasheet at https://www.nxp.com/docs/en/data-sheet/MPVZ5150.pdf. The datasheet includes the pressure-transfer function, accuracy curves, mechanical drawings, and application circuit recommendations. DigiKey also hosts a copy on its product page for offline reference.
Where is the MPVZ5150GC7U pinout located?
The MPVZ5150GC7U pinout is shown on page 2 of the NXP MPVZ5150 family datasheet, with pin 1 marked by the notch on the 8-DIP package. Pins are: 1 VDD, 2 VOUT, 3 GND, 4-8 NC/structural. The top-port pressure inlet is on the lid of the case, oriented toward the user when pin 1 is at the lower-left. Always confirm the pinout against the latest datasheet revision before PCB layout.
Does the MPVZ5150GC7U need external signal conditioning?
No, the MPVZ5150GC7U has the signal conditioning, temperature compensation, and calibration integrated on-chip. The raw piezoresistive bridge signal is amplified, offset-corrected, and scaled inside the device so the output pin delivers 0.2 V to 4.7 V linearly mapped to 0 to 150 kPa. Designers only need to add a decoupling capacitor on VDD and optionally an RC low-pass filter on VOUT to suppress ADC switching noise.
Can the MPVZ5150GC7U measure liquid pressure?
No, the MPVZ5150GC7U is designed for dry air and non-corrosive gases only, with the sensor protected by a silicone gel isolation layer. Liquid ingress can damage the gel and bias the sensor permanently. For liquid pressure measurement, consider the MPXM2053GS or MPX5999D series, which use a ported media-isolated diaphragm suitable for non-aggressive gas disposal. Always check the media-compatibility section of the datasheet.
What is the key engineering benefit of MPVZ5150GC7U?
The MPVZ5150GC7U integrates piezoresistive sensing, ASIC signal conditioning, and temperature calibration into a single calibrated analog-output device, eliminating the need for an external op-amp, lookup tables, or production-line calibration. The vented gauge reference also removes the requirement for a separate barometric sensor in weather and altitude applications. Combined with the through-hole 8-DIP package, this shortens design cycles for HVAC, medical, and industrial pressure products.

Справочные инженерные данные для MPVZ5150GC7U — сравнение, рекомендации по проектированию и информация о соответствии.

Руководство по выбору

Choose the MPVZ5150GC7U when your application measures pressure in the 0 to 150 kPa vented gauge range - barometric weather stations, altimeters, HVAC duct static pressure above 10 kPa, and pneumatic industrial systems above 10 kPa. Choose the MPXV5010GC7U when measuring very low pressures (0 to 10 kPa) like HVAC duct airflow or respirator flow. Choose the MPXV7002GC7U for bidirectional differential sensing (e.g., -2 to +2 kPa). All three share the same Case 867F 8-DIP package, so the same PCB layout can host any of them - the choice is purely about pressure range. For OEM volume, prefer the T1 (tape-and-reel) suffix for automated assembly.

Сравнение с аналогами

Параметр Этот товар MPVZ5150GC6T1 MPVZ5150GC6U MPXV5010GC7U MPXV10GC7U MPXV7002GC7U
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors
Package 8-DIP (Case 867F) 8-DIP (Case 867F) - same 8-DIP (Case 867F) - same 8-DIP (Case 867F) - same 8-DIP (Case 867F) - same 8-DIP (Case 867F) - same
Pressure Range 0 to 150 kPa (vented gauge) 0 to 150 kPa (vented gauge) 0 to 150 kPa (vented gauge) 0 to 10 kPa 0 to 10 kPa -2 to +2 kPa (differential)
Output Voltage 0.2 V to 4.7 V 0.2 V to 4.7 V 0.2 V to 4.7 V 0.2 V to 4.7 V 0.2 V to 4.7 V 0.5 V to 4.5 V
Supply Voltage 4.75 V to 5.25 V 4.75 V to 5.25 V 4.75 V to 5.25 V 4.75 V to 5.25 V 4.75 V to 5.25 V 4.75 V to 5.25 V
Accuracy ±1.5 % (0 to 85 °C) ±1.5 % (0 to 85 °C) ±1.5 % (0 to 85 °C) ±1.5 % (0 to 85 °C) ±1.0 % (0 to 85 °C) ±2.5 % (0 to 85 °C)
Pressure Type Vented Gauge Vented Gauge Vented Gauge Vented Gauge Vented Gauge Differential (bidirectional)
Port Orientation Top port Top port Top port Top port Top port Top port

Ключевые отличия

  • Vented gauge reference built in (против MPXV5010GC7U)
  • Highest range in the 8-DIP Case 867F family (против MPXV7002GC7U)
  • Integrated calibration and temperature compensation (против Discrete bridge + external op-amp)

Заметки по проектированию

Decouple VDD (pin 4) with a 0.01 µF to 0.1 µF ceramic capacitor placed within 5 mm of the package pin, with a ground return on a low-impedance plane. The MPVZ5150GC7U draws modest supply current at 5 V, but the on-chip ASIC is sensitive to high-frequency VDD noise. Route VDD away from switching nodes such as DC-DC inductor traces. The ratiometric output scales with VDD, so a clean 5 V rail is essential for accuracy.

Keep the top-port pressure inlet clear of solder flux, conformal coating, and debris - any blockage or film on the silicone gel will bias the reading. Use a 0.1 inch (2.54 mm) pitch 8-DIP socket or hand-solder the through-hole leads with proper thermal relief. Route VOUT in a guarded trace or shielded layer if the host PCB has switching converters; long unshielded traces degrade the ADC reading by injecting 5 V switching noise into the analog signal.

Place a first-order RC low-pass filter (R=1 kΩ, C=100 nF) on VOUT close to the MCU ADC pin to suppress high-frequency noise from the MCU's switching I/O. The MPVZ5150GC7U bandwidth is approximately 1 kHz, so a 1.6 kHz filter corner is appropriate. Use the MCU's internal averaging of 16+ samples to further reduce noise. Verify the filter does not significantly slow the pressure response for fast-changing applications such as respiratory sensing.

Estimated: when adapting the MPVZ5150GC7U to a 3.3 V MCU ADC, use a 1:1.5 resistor divider on VOUT to avoid saturating the ADC at the upper end of the range. Do not connect liquid lines directly to the top port - the silicone gel isolation is rated for dry air and non-corrosive gases only, and liquid ingress permanently biases the sensor. Do not apply pressure beyond the datasheet-specified maximum overload, as this may crack the silicon diaphragm and cause catastrophic failure.

Информация о соответствии

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Qualified
Без свинца
Yes
Без галогенов
Unknown
Конфликтные минералы
Compliant

RoHS and lead-free status confirmed via NXP product page and distributor listings; halogen-free status not explicitly stated in verified web data. Not AEC-Q100 qualified - choose MPXV series with automotive suffix for vehicle applications.

Данные проверены: 2026-10-15 — данные проверены и курируются командой компонентной инженерии XAIPART

Похожие запросы

MPVZ5150GC7U MPVZ5150GC7U datasheet NXP MPVZ5150GC7U 150 kPa pressure sensor DIP 8-DIP Case 867F pressure sensor MPVZ5150 barometric sensor MPVZ5150GC7U vs MPXV5010GC7U MPVZ5150GC7U drop-in replacement buy MPVZ5150GC7U online vented gauge pressure sensor 5V analog output MPVZ5150 pinout 8-DIP NXP piezoresistive sensor HVAC

Связанные компоненты & термины

NXP Semiconductors MPVZ5150GC7U MPVZ5150GC6T1 MPVZ5150GC6U MPXV5010GC7U MPXV10GC7U MPXV7002GC7U pressure sensor piezoresistive transducer MEMS pressure sensor vented gauge analog voltage output ratiometric output 8-DIP Case 867F ASIC signal conditioning temperature compensation silicone gel isolation barometric pressure HVAC pressure monitoring RoHS
Быстрый запрос цены (RFQ)
Заполните все данные — наша команда продаж ответит в течение 24 часов
Артикул Производитель Корпус QTY Целевая цена Итого
Итого: $0.00 USD
✓
Запрос цены отправлен!

Мы ответим на ваш email в течение 24 часов

1
RFQ отправлен
2
Предложение получено
3
Заказ оформлен
4
Оплата
5
Отправлено
6
Доставлено
Просмотреть детали RFQ