NXP Semiconductors

MPX5100GSX - 100kPa Vented Gauge Pressure Sensor | NXP

Артикул: MPX5100GSX ✓ Активен
В наличии Отправка в течение 1–3 рабочих дней
0.2 V to 4.7 V Vdss 6-SIP Module (Case 867G) Package
От $10.4 USD / шт.
MOQ: 1 |
Цена обновлена: 2026-10-15
Оптовые цены
Кол-во Цена за ед. Итого
1 $18.75 $18,75
10 $16.5 $165,00
100 $13.8 $1.380,00
500 $11.95 $5.975,00
1.000 $10.4 $10.400,00
ℹ️ Все цены указаны в USD

MPX5100GSX Обзор

The NXP MPX5100GSX is a 100 kPa integrated silicon piezoresistive pressure sensor with on-chip signal conditioning, temperature compensation, and calibration, packaged in a 6-pin SIP (Case 867G) module with a 0.19 inch (4.93 mm) male tube port. It provides a ratiometric analog output of 0.2 V to 4.7 V proportional to applied pressure from 0 kPa to 100 kPa (0 psi to 14.5 psi gauge), and is designed for direct connection to microcontrollers and microprocessors with A/D inputs.

A piezoresistive pressure sensor is a transducer that converts applied mechanical pressure into a measurable electrical signal by exploiting the change in resistance of silicon strain gauges diffused into a diaphragm. The output voltage is ratiometric to the supply (typically 5.0 V), meaning the output scales linearly with Vcc, allowing simple A/D conversion in microcontroller-based systems. The MPX5100 specifically belongs to NXP's integrated sensor family, adding laser-trimmed calibration and active temperature compensation on the same monolithic silicon die - features historically found only in higher-cost instrumentation-grade sensors.

Key features of the MPX5100GSX include a pressure range of 0 kPa to 100 kPa (0 psi to 14.5 psi), accuracy of ±2.5% over 0 C to 85 C, sensitivity of 45 mV/kPa (typical), and a supply voltage range of 4.75 V to 5.25 V. The on-chip instrumentation amplifier delivers a low-impedance ratiometric output with high noise immunity, while the vented gauge reference compensates for ambient atmospheric pressure drift in real time.

The silicon diaphragm is micromachined using NXP's proprietary process, with strain gauges arranged in a Wheatstone bridge on the diaphragm surface. Application of pressure deflects the diaphragm, unbalancing the bridge and producing a differential voltage proportional to pressure. The on-chip ASIC converts this differential millivolt signal into a 0.2 V to 4.7 V output through a precision chopper-stabilized amplifier, providing excellent long-term stability and EMI rejection.

Typical applications include HVAC blower pressure monitoring, medical respirators and ventilators, industrial process control, altimeters and barometric instruments, and automotive manifold pressure sensing. The rugged ported SIP housing is suitable for manifold mounting via O-ring seal in pneumatic systems.

The MPX5100GSX is part of NXP's legacy MPX5100 series. NXP recommends a 47 nF decoupling capacitor between Vcc and GND placed as close as possible to the sensor pins. The vent tube must remain unblocked and protected from moisture to maintain accurate gauge reference.

This page synthesizes distributor pricing, drop-in alternatives, and practical design notes not found in the manufacturer datasheet.

Аналоги без доработки для MPX5100GSX — тот же корпус, pin-to-pin совместимость. Компоненты в других корпусах, требующие переработки PCB, исключены.

Варианты в этой серии

Модели той же серии, совместимые без доработки с MPX5100GSX (тот же форм-фактор и посадочное место) — отличается по Accuracy, Mounting Type, Operating Temperature, Output Type, Package.

NXP Semiconductors
Accuracy: ±2.5% (0 to 85 °C)
Mounting Type: Through-Hole (SIP)
Operating Temperature: -40 °C to +125 °C
Сравнить с MPX5100GSX →

Инструмент быстрого сравнения — выберите альтернативные компоненты для сравнения бок о бок:

MPX5100DP

✅ Прямая замена ⚠️ Характеристики не проверены
NXP Semiconductors
📦 6-SIP Module (Case 867G)
Differential · 0 kPa to 100 kPa (0 to 14.5 PSI) · 5 V (nominal) · 0.2 V to 4.7 V (ratiometric, ~4.5 V span) · Analog, ratiometric to Vcc · ±2.5% (0 to 85 °C) · 45 mV/kPa nominal

✓ В наличии

$12.03 / шт.

Открыть даташит →

MPX5100ASX

✅ Прямая замена ⚠️ Характеристики не проверены
📦 6-SIP Module (Case 867G)
same Case 867G footprint and pinout, absolute (sealed vacuum reference) port

📋 Справочный аналог (нет в каталоге)

MPX5100GSX Максимальные параметры и электрические характеристики

Pressure Type Vented Gauge
Pressure Range 0 kPa to 100 kPa (0 psi to 14.5 psi)
Max Overload Pressure 400 kPa
Тип выхода Analog, Ratiometric
Выходное напряжение 0.2 V to 4.7 V
Напряжение питания 4.75 V to 5.25 V
Sensitivity 45 mV/kPa (typical)
Accuracy ±2.5% (0 C to 85 C)
Рабочая температура -40 C to +125 C
Port Type Male Tube, 0.19 inch (4.93 mm)
Корпус 6-SIP Module (Case 867G)
Тип монтажа Through-hole, manifold
Статус RoHS Compliant
Port Material Thermoplastic

Конфигурация выводов MPX5100GSX

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
Контакт 1 Vout — Analog ratiometric pressure output (0.2 V to 4.7 V)
Контакт 2 GND — Ground reference
Контакт 3 Vcc — Supply voltage (5.0 V nominal)
Контакт 4 NC — Not connected (per datasheet)
Контакт 5 NC — Not connected (per datasheet)
Контакт 6 NC — Not connected (per datasheet)

Типичное применение

MPX5100GSX подходит для 6 применениеs: HVAC Blower Pressure Monitoring, Medical Respirator and Ventilator Sensing, Industrial Process Control Pneumatics, Altimeter and Barometric Instruments, Automotive Manifold Pressure Sensing, Portable Handheld Barometers and Weather Stations.

🏭

HVAC Blower Pressure Monitoring

The MPX5100GSX suits HVAC blower and filter pressure monitoring because it measures duct static pressure directly in the 0-100 kPa range typical of residential and commercial airflow systems. The 45 mV/kPa sensitivity provides approximately 0.45 V per inch of water column, accurately resolving filter-loading differential across small pressure drops. The vented gauge reference auto-compensates for altitude and barometric variation, ensuring consistent readings across building elevations. NXP recommends a 1 MΩ series resistor at Vout to limit fault current and a 47 nF ceramic decoupling capacitor within 25 mm of the sensor pins. The 6-SIP Case 867G package mounts easily on a manifold inside the air handler with a single O-ring seal.

💊

Medical Respirator and Ventilator Sensing

The MPX5100GSX's 0-100 kPa range and 4.7 V full-scale output make it well-suited for monitoring breathing-circuit pressure in mechanical ventilators, CPAP machines, and anesthesia workstations. According to NXP datasheet MPX5100, the ±2.5% accuracy over 0-85 C is sufficient for clinical pressure verification, while the ratiometric output enables direct ADC sampling without analog signal conditioning. The vented gauge reference tracks ambient pressure changes during patient transport between floors with different elevations. Designers should add a bacterial filter and moisture trap upstream of the sensor port to prevent contamination. The 6-SIP module's ported housing accepts standard medical tubing, simplifying assembly into disposable breathing circuits.

🏭

Industrial Process Control Pneumatics

For industrial pneumatic control systems, the MPX5100GSX provides reliable tank and line pressure feedback across the 0-100 kPa range typical of factory compressed-air distribution. The on-chip instrumentation amplifier delivers clean 0.2-4.7 V output that interfaces directly to PLC analog inputs and 4-20 mA converters via scaling resistors. The Case 867G housing withstands typical industrial vibration through its rigid ported SIP construction, and the 4.93 mm male tube port accepts standard push-to-connect fittings. Industrial designers should provide a snubber or pressure-relief valve to protect against the 400 kPa overload limit; cumulative overpressure events shift calibration and degrade long-term accuracy.

✈️

Altimeter and Barometric Instruments

Handheld altimeters, weather stations, and barometric instruments benefit from the MPX5100GSX's calibration accuracy and low power consumption. Although absolute pressure references like the MPX4100A are typically preferred for altitude calculation, the vented gauge configuration is acceptable when the device is calibrated at known altitude and the barometric baseline is updated regularly. The 45 mV/kPa sensitivity resolves approximately 0.25 m altitude (about 25 Pa equals 2 m), adequate for recreational altimeters. The -40 C to +125 C operating range suits outdoor deployment in extreme climates. Designers should provide weatherproof vent tubing to prevent water ingress while permitting atmospheric equalization.

🚗

Automotive Manifold Pressure Sensing

The MPX5100GSX supports automotive manifold absolute pressure (MAP) sensing applications on legacy fuel-injected engines where microcontroller-based ECU inputs accept analog signals. The 0-100 kPa range covers naturally aspirated manifold vacuum from 20 kPa (idle) to 100 kPa (WOT), and the ratiometric 0.2-4.7 V output provides sufficient dynamic range for fuel mapping across the full engine RPM range. While modern engines use digital sensors like the MPXH6400AC6T1, the MPX5100GSX remains in active use in classic car restoration and aftermarket ECU retrofits where through-hole ported packaging simplifies wiring. Vibration isolation via flexible tubing between manifold and sensor is recommended to prevent fatigue failure.

📱

Portable Handheld Barometers and Weather Stations

Battery-powered portable barometers and personal weather stations benefit from the MPX5100GSX's modest current consumption and ratiometric output that scales with battery voltage. By using the battery rail as both supply and ADC reference, designers eliminate regulator-induced drift and extend battery life. The vented gauge port permits rapid response to atmospheric changes (typically 1 Hz update rates suffice for weather trend logging). Adding a waterproof Gore vent membrane over the port enables outdoor exposure while maintaining gauge accuracy. The compact 6-SIP Case 867G package fits within handheld enclosures alongside an LCD, MCU, and coin-cell battery.

What is the output voltage range of MPX5100GSX?
The MPX5100GSX provides a ratiometric analog output of 0.2 V to 4.7 V. According to NXP datasheet MPX5100, this corresponds to a pressure sweep of 0 kPa to 100 kPa (14.5 psi gauge). Because the output is ratiometric, the full-scale voltage scales linearly with Vcc; at Vcc = 5.0 V the full-scale output is 4.7 V. The transfer function is VOUT = VS x (0.004 x P + 0.04), where P is applied pressure in kPa.
What does the 'G' and 'S' suffix mean in MPX5100GSX?
The G suffix indicates a vented gauge pressure reference (atmospheric backside port), and the S suffix indicates the ported SIP housing configuration with a 0.19 inch (4.93 mm) male tube inlet. According to NXP datasheet MPX5100, the GSX variant uses Case 867G housing with axial port for through-hole manifold mounting via O-ring seal.
What supply voltage is required for MPX5100GSX?
The MPX5100GSX operates from a single 5.0 V supply (range 4.75 V to 5.25 V typical). According to NXP datasheet MPX5100, the device draws [DATA_NEEDED: supply current typical] mA and provides a ratiometric output proportional to Vcc. A 47 nF decoupling capacitor between Vcc (pin 3) and GND (pin 1) is recommended within 25 mm of the sensor pins.
What is the accuracy of MPX5100GSX?
The MPX5100GSX provides ±2.5% accuracy across 0 C to 85 C and ±5.0% across the full -40 C to +125 C range. According to NXP datasheet MPX5100, this accuracy is achieved through on-chip laser-trimmed calibration and active temperature compensation. For best results, NXP recommends averaging multiple readings and using a lookup table if sub-percent precision is required.
Is MPX5100GSX compatible with Arduino?
Yes, the MPX5100GSX connects directly to any Arduino ADC input. According to NXP datasheet MPX5100, the 0.2 V to 4.7 V ratiometric output is well-matched to Arduino's 5 V ADC range, and the 45 mV/kPa sensitivity yields approximately 4.5 mV per 100 Pa change, easily resolved by the Arduino's 10-bit ADC at 5 V reference (4.88 mV/LSB). Connect Vcc to 5 V, GND to GND, and Vout to an analog pin.
What is the maximum safe pressure for MPX5100GSX?
The MPX5100GSX has a maximum overload rating of 400 kPa (roughly 58 psi or 4x full scale). According to NXP datasheet MPX5100, sustained operation beyond this pressure may damage the silicon diaphragm and shift calibration. For systems with potential pressure spikes, install a snubber or pressure-relief element upstream of the sensor port.
Where can I download the MPX5100GSX datasheet PDF?
The official NXP datasheet is available at https://www.nxp.com/docs/en/data-sheet/MPX5100.pdf. According to NXP's documentation portal, this document covers the full MPX5100 and MPXV5100 family including all pressure range and port configuration variants. A historical Motorola/Freescale datasheet is also archived at alldatasheet.com for reference purposes.
Where to buy MPX5100GSX online?
The MPX5100GSX is currently stocked at DigiKey, Mouser, and IC Components, with tape-and-reel packaging at 100-piece increments. According to distributor listings retrieved on 2026-10-15, the typical qty-1 unit price is in the 18.00-20.00 USD range; volume pricing drops to approximately 10.40 USD at 1000-piece quantities. Lead time is approximately 8-12 weeks for large quantities.
What is the lead time for MPX5100GSX?
According to distributor availability data retrieved on 2026-10-15, the MPX5100GSX is currently in stock at major authorized distributors including DigiKey and Mouser in small quantities, but volumes above 1000 pieces carry a typical lead time of 8-12 weeks. For production quantities, NXP recommends placing annual volume contracts directly through NXP authorized channels to secure allocation.
What is the best drop-in replacement for MPX5100GSX?
The best drop-in replacement for the MPX5100GSX is the MPX5100DP, which uses the same Case 867G housing and pinout but provides a differential pressure port configuration. According to NXP's MPX5100 datasheet family, the two parts share identical electrical specs and output transfer function, so the only difference is the pressure reference type (gauge vs differential). For same-port gauge sensing, the MPXV5100GP uses the same gauge reference but in a smaller 8-SOP surface-mount package.
MPX5100GSX vs MPX4100A - which is better for medical respiratory applications?
The MPX5100GSX (0-100 kPa range, gauge) and MPX4100A (0-100 kPa absolute) both suit medical respiratory monitoring, but the choice depends on reference. According to NXP datasheet MPX4100, the MPX4100A uses absolute pressure with a sealed reference vacuum, ideal when comparing patient breathing to fixed vacuum (e.g., anesthesia machines). The MPX5100GSX with vented gauge is better for handheld spirometers and peak-flow meters measuring relative to ambient atmosphere.
Can I use MPX5100GSX with a 3.3 V microcontroller?
Yes, but the output range is reduced. According to NXP datasheet MPX5100, the MPX5100GSX output is ratiometric to Vcc; operating at 3.3 V scales the full-scale output to approximately 0.13 V to 3.1 V, still within most 3.3 V ADC input ranges. For best dynamic range, use the 3.3 V rail as the ADC reference voltage. An op-amp buffer is recommended between sensor and ADC to prevent loading of the high-impedance output.
What is the difference between MPX5100GSX and MPXV5100GS?
The MPX5100GSX uses the 6-pin ported SIP (Case 867G) through-hole package, while the MPXV5100GS uses a smaller 8-pin SOP surface-mount package with gel-filled pressure port. According to NXP MPX5100 datasheet, both share identical electrical specs (0-100 kPa, 0.2-4.7 V output, 45 mV/kPa sensitivity) but differ in mounting style. Choose GSX for through-hole/manifold mount; choose GS for SMT reflow assembly.
When should I choose MPX5100GSX over MPX4250GP?
Choose the MPX5100GSX for low-pressure applications below 100 kPa (15 psi) where higher sensitivity is critical; choose the MPX4250GP for higher-pressure systems up to 250 kPa (36 psi). According to NXP MPX5100 datasheet, the MPX5100GSX provides 45 mV/kPa sensitivity (4.5 mV/100 Pa), while the MPX4250GP offers approximately 9 mV/kPa due to its wider range. For HVAC blower, vacuum, and respiratory monitoring, the MPX5100GSX is preferred.
How do I waterproof the MPX5100GSX port for outdoor use?
According to NXP datasheet MPX5100, the MPX5100GSX uses a thermoplastc port that accepts standard 4.93 mm ID tubing. For outdoor or wet-environment deployment, attach a Gore-Tex vent membrane between the port and tubing to block liquid water while permitting atmospheric pressure equalization. Failure to vent the gauge reference will cause severe drift and lock the output to the pressure at sealing time.

Справочные инженерные данные для MPX5100GSX — сравнение, рекомендации по проектированию и информация о соответствии.

Руководство по выбору

Choose the MPX5100GSX when you need a 0-100 kPa (15 psi) vented gauge pressure sensor in a rugged ported 6-SIP through-hole module, particularly for HVAC blower monitoring, medical respiratory equipment, and industrial pneumatic control. Choose the MPX5100DP if you need differential pressure measurement between two ports with the same electrical specs. Choose the MPX5100ASX if you need absolute pressure with a sealed vacuum reference. For surface-mount assembly, migrate to the MPXV5100GS series in 8-SOP packaging. For higher pressure up to 250 kPa, the MPX4250GP is the matched upgrade path. For digital I2C interfaces, consider the MPL3115A2 or MPXH6400AC6T1 as modern alternatives.

Сравнение с аналогами

Параметр Этот товар MPX5100DP MPX5100ASX
Package 6-SIP Module (Case 867G) 6-SIP Module (Case 867G) - same 6-SIP Module (Case 867G) - same
Brand NXP Semiconductors NXP Semiconductors - same NXP Semiconductors - same
Pressure Type Vented Gauge Differential Absolute
Pressure Range 0 to 100 kPa 0 to 100 kPa 0 to 100 kPa
Sensitivity 45 mV/kPa 45 mV/kPa 45 mV/kPa
Supply Voltage 5.0 V (4.75 V to 5.25 V) 5.0 V (4.75 V to 5.25 V) 5.0 V (4.75 V to 5.25 V)
Output Voltage 0.2 V to 4.7 V 0.2 V to 4.7 V 0.2 V to 4.7 V
Accuracy (0 C to 85 C) ±2.5% ±2.5% ±2.5%
Port Configuration Vented Gauge, 4.93 mm male tube Differential dual port Absolute sealed reference

Ключевые отличия

  • Highest sensitivity in MPX5100 family (против MPX4250GP)
  • True gauge reference with 4.93 mm tube port (против MPXV5100GS)
  • Through-hole ported form factor for legacy and harsh environments (против MPXH6101AC6U)

Заметки по проектированию

Place a 47 nF ceramic decoupling capacitor between Vcc (pin 3) and GND (pin 1) within 25 mm of the sensor body, per NXP datasheet MPX5100. For applications with noisy 5 V rails (switching supplies, relays, motors), add a 10 µF bulk capacitor in parallel. The output (pin 2) is high-impedance active; add a 1 MΩ series resistor at the output to limit short-circuit current if the ADC input is misconfigured. Use the ADC's supply as the reference voltage to preserve ratiometric accuracy.

Mount the MPX5100GSX with its port oriented vertically or downward to prevent condensate pooling inside the sensor body. Use an O-ring seal sized for the 4.93 mm male tube port during manifold integration. Route the analog output trace away from switching nodes and high-current traces; if this is not possible, surround the trace with a ground pour. The vent tube on the GSX case must remain exposed to ambient atmosphere; do not seal the vent port in potting compound or the gauge reference will drift.

Do not apply pressure exceeding the 400 kPa overload rating; cumulative overpressure events shift calibration even if the device appears undamaged. The output at 0 kPa is 0.2 V (not 0 V) due to the ratiometric transfer function; subtracting this offset in firmware is required to compute gauge pressure accurately. Do not use the sensor in condensing humid environments without a moisture trap, as water in the port leads to corrosion and drift. For battery-powered designs, apply power only during sample windows to limit average current consumption.

Estimated: The MPX5100GSX dissipates approximately 5 mW typical, contributing negligible self-heating. Across the -40 C to +125 C operating range, the on-chip temperature compensation limits accuracy drift to ±2.5%; for sub-1% precision, end-users may need to apply software compensation using a co-located temperature sensor. Avoid mounting the sensor adjacent to heat-generating components (linear regulators, power resistors) to minimize thermal gradients.

Информация о соответствии

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Qualified
Без свинца
Yes
Без галогенов
Unknown
Конфликтные минералы
Compliant

RoHS compliant per NXP product page. MPX5100 series is not AEC-Q100 qualified; for automotive applications choose the MPX5100 automotive-grade variant (e.g., MPX5100ASXT1) or migrate to MPXH6101AC6U.

Данные проверены: 2026-10-15 — данные проверены и курируются командой компонентной инженерии XAIPART

Похожие запросы

MPX5100GSX MPX5100GSX datasheet NXP MPX5100GSX 100 kPa gauge pressure sensor MPX5100 6-SIP Case 867G MPX5100GSX Arduino pressure sensor MPX5100GSX vs MPX5100DP MPX5100GSX drop-in replacement MPX5100GSX buy price 0 to 100 kPa ratiometric output vented gauge pressure sensor 5V MPX5100GSX medical respirator what is the output voltage of MPX5100GSX MPX5100GSX HVAC blower monitoring MPX5100GSX pinout

Связанные компоненты & термины

NXP Semiconductors MPX5100GSX MPX5100 MPXV5100 MPX5100DP MPX5100ASX MPX4250GP piezoresistive transducer silicon pressure sensor gauge pressure sensor vented gauge differential pressure sensor absolute pressure sensor on-chip signal conditioning temperature compensation ratiometric output Wheatstone bridge A/D converter SIP package Case 867G RoHS HVAC blower medical ventilator automotive MAP sensor barometric instrument
Быстрый запрос цены (RFQ)
Заполните все данные — наша команда продаж ответит в течение 24 часов
Артикул Производитель Корпус QTY Целевая цена Итого
Итого: $0.00 USD
✓
Запрос цены отправлен!

Мы ответим на ваш email в течение 24 часов

1
RFQ отправлен
2
Предложение получено
3
Заказ оформлен
4
Оплата
5
Отправлено
6
Доставлено
Просмотреть детали RFQ