MPXV2010GP Обзор

The STMicroelectronics MPXV2010GP is a 10 kPa silicon piezoresistive pressure sensor in a surface-mount 8-SMD gull-wing package with a vertical side port. It provides a linear voltage output directly proportional to applied pressure, with the output span ratiometric to a 10 V supply (0 mV at 0 kPa to 25 mV at 10 kPa nominal), and is offered as a vented gauge configuration for cleanroom-side reference.

A piezoresistive pressure sensor is a MEMS device in which a monolithic silicon diaphragm and an integrated strain-gauge resistor network convert mechanical pressure into a millivolt-level analog voltage. The MPXV2010GP sits in the hierarchy of: pressure transducer -> MEMS pressure sensor -> signal-conditioning sensor -> sensor IC. The on-chip thin-film resistor network is laser-trimmed for span, offset, and temperature compensation, which removes the need for external calibration and simplifies firmware-side linearization in host MCUs.

Key features include a 0–10 kPa operating range, 25 mV full-scale span at 10 V excitation, 1.0 kPa typical pressure hysteresis, an integrated temperature compensation network, and ratiometric output that tracks supply voltage. The case 344B-01 package (8-SMD, gull-wing, side port) provides a robust surface-mount form factor with the pressure port on the package side, enabling vertical pneumatic coupling through a single 3.17 mm (0.13") tube barbed inlet.

The MPXV2010GP uses a monolithic silicon diaphragm with a Wheatstone-bridge strain-gauge configuration; bridge excitation at 10 V DC produces a differential millivolt signal proportional to differential pressure. The trimming process calibrates each device at room temperature and 0/10 kPa, with downstream accuracy dependent on the chosen ADC resolution and reference, and on conditioning the output through an instrumentation amplifier before MCU sampling.

Typical applications include HVAC differential pressure monitoring, medical respirators and ventilators, industrial process control, air-flow measurement in variable-air-volume (VAV) boxes, and low-pressure process instrumentation where 0–10 kPa sensing with a clean vented reference is required. The vented gauge reference makes the device well-suited to barometric-style measurements where backside absolute-pressure artifacts must be excluded.

When designing with the MPXV2010GP, use a low-impedance instrumentation amplifier at the sensor output to preserve the mV-level signal and reject common-mode noise, and place a 0.01 uF bypass capacitor close to the supply pin. The output is ratiometric, so using a stable, low-noise 10 V reference yields the best full-scale accuracy.

This page synthesizes distributor stock, drop-in same-package alternatives from the NXP MPX2010 family, and practical signal-conditioning design notes not found in the MPXV2010GP datasheet alone.

Аналоги без доработки для MPXV2010GP — тот же корпус, pin-to-pin совместимость. Компоненты в других корпусах, требующие переработки PCB, исключены.

Варианты в этой серии

Модели той же серии, совместимые без доработки с MPXV2010GP (тот же форм-фактор и посадочное место) — отличается по Operating Pressure Range, Output Type, Temperature Compensation, Package, Port Style.

NXP Semiconductors
Output Type: Analog voltage, Wheatstone bridge (mV level)
Temperature Compensation: 0 °C to +85 °C (on-chip)
Сравнить с MPXV2010GP →
STMicroelectronics
Operating Pressure Range: 0 kPa to 10 kPa (0 to 1.45 PSI)
Temperature Compensation: On-chip, calibrated
Port Style: Male, 0.19 inch (4.93 mm) tube, vented gauge
Сравнить с MPXV2010GP →
NXP Semiconductors
Operating Pressure Range: 0 kPa to 10 kPa (0 to 1.45 PSI)
Output Type: Wheatstone Bridge (analog, differential mV)
Temperature Compensation: On-chip (laser-trimmed thin-film)
Сравнить с MPXV2010GP →
STMicroelectronics
Operating Pressure Range: 0 kPa to 10 kPa (0 PSI to 1.45 PSI)
Output Type: Analog, Ratiometric
Temperature Compensation: On-Chip, 0 C to 85 C
Сравнить с MPXV2010GP →
NXP Semiconductors
Operating Pressure Range: 0 kPa to 50 kPa (0 PSI to 7.25 PSI)
Output Type: Analog, Wheatstone bridge (mV differential)
Temperature Compensation: On-chip, calibrated
Сравнить с MPXV2010GP →
NXP Semiconductors
Operating Pressure Range: 0 kPa to 100 kPa (0 to 14.5 PSI)
Сравнить с MPXV2010GP →
NXP Semiconductors
Operating Pressure Range: 0 kPa to 200 kPa (0 psi to 29.01 psi)
Output Type: Analog voltage (ratiometric, differential bridge)
Temperature Compensation: On-chip, 0 C to 85 C
Сравнить с MPXV2010GP →

Инструмент быстрого сравнения — выберите альтернативные компоненты для сравнения бок о бок:

MPX2010DP

✅ Прямая замена
NXP Semiconductors
📦 8-SMD, Gull Wing, Side Port (Case 344B-01)
Differential Pressure Sensor · 0 to 10 kPa (0 to 1.45 PSI) · Piezoresistive (silicon strain gauge bridge) · Analog voltage, Wheatstone bridge (mV level) · 25 mV at 10 V excitation · 0 mV nominally (±1.0 mV max) · 10 V DC typical (max 16 V) · ±0.05% (typ)

✓ В наличии

$8.5 / шт.

Открыть даташит →

MPX2010GP

✅ Прямая замена
STMicroelectronics
📦 8-SMD, Gull Wing, Side Port (Case 344B-01 family)
Vented Gauge · 0 kPa to 10 kPa (0 to 1.45 PSI) · 25 mV typical at 10 V excitation · 0 mV to 25 mV (10 V supply) · 0 mV nominal · 10 V DC typical (max per datasheet) · 6 mA DC typical

✓ В наличии

$7.2 / шт.

Открыть даташит →

MPXV2053GP

✅ Прямая замена
NXP Semiconductors
📦 8-SMD, Gull Wing, Side Port
Vented Gauge · 0 kPa to 50 kPa (0 PSI to 7.25 PSI) · Analog, Wheatstone bridge (mV differential) · 0 mV to 40 mV (typ) at 10 V supply · 10 V typical (ratiometric output) · Top-side, male tube 0.13" (3.17 mm) · 8-SMD, Gull Wing, Side Port

✓ В наличии

$10.5 / шт.

Открыть даташит →

MPXV2102GP

✅ Прямая замена
NXP Semiconductors
📦 8-SMD, Gull Wing, Side Port
Vented Gauge · 0 kPa to 100 kPa (0 to 14.5 PSI) · 10 V DC typical · 40 mV at 10 V · 0.4 mV/kPa · ±1 mV (after laser trim) · ±0.25% of span (typ)

✓ В наличии

$5.6 / шт.

Открыть даташит →

MPXV2202GP

✅ Прямая замена
NXP Semiconductors
📦 8-SMD, Gull Wing, Side Port
NXP Semiconductors · Piezoresistive Pressure Sensor · Vented Gauge · 0 kPa to 200 kPa (0 psi to 29.01 psi) · 10 V typical · Analog voltage (ratiometric, differential bridge) · 0 mV to 40 mV at 10 V supply · 0.2 mV/V nominal

✓ В наличии

$5.5 / шт.

Открыть даташит →

MP3V5010GC6U

✅ Прямая замена
📦 8-SMD, Gull Wing, Side Port
integrated signal conditioning (0.2-4.7 V amplified output) vs raw 25 mV mV output; same 0-10 kPa range

📋 Справочный аналог (нет в каталоге)

MPXV2010GP Максимальные параметры и электрические характеристики

Pressure Type Vented Gauge
Operating Pressure Range 0 kPa to 10 kPa
Maximum Overload Pressure 75 kPa
Supply Voltage (Vex) 10 V typical (max 16 V)
Full-Scale Output (Span) at 10 V 25 mV nominal at 10 kPa
Zero Pressure Output (Offset) 0 mV to 1.0 mV
Pressure Hysteresis 1.0 kPa (typical)
Sensitivity 2.5 mV/kPa nominal at 10 V
Response Time 1.0 ms (typical)
Тип выхода Analog, ratiometric, mV output
Рабочая температура -40 C to +125 C
Port Configuration Single vertical side port, 0.13" (3.17 mm) tube
Корпус 8-SMD, Gull Wing, Side Port (Case 344B-01)
Тип монтажа Surface Mount
Technology Silicon piezoresistive MEMS, on-chip temp compensated
Статус RoHS Compliant

Конфигурация выводов MPXV2010GP

SOIC-8 Package Pinout Diagram SOIC-8 8-pin small outline IC, 3.9x4.9mm, P1.27mm, JEDEC MS-012. 1 8 2 7 3 6 4 5 SOIC-8
Контакт 1 Vs — Voltage excitation (+10 V nominal)
Контакт 2 Vout+ — Positive output (mV proportional to pressure)
Контакт 3 Vout+ — Positive output tied to pin 2
Контакт 4 GND — Ground reference
Контакт 5 GND — Ground reference (tied to pin 4)
Контакт 6 Vout- — Negative output (mV proportional to pressure)
Контакт 7 Vout- — Negative output tied to pin 6
Контакт 8 Vref — Vented-gauge reference (atmosphere)

Типичное применение

MPXV2010GP подходит для 6 применениеs: HVAC Differential Pressure Monitoring, Medical Respirator and Ventilator Pressure Sensing, Industrial Process Air-Flow Measurement, Barometric Reference and Altitude Compensation, Liquid-Level and Column-Pressure Sensing, Pneumatic Leak Testing and Inline Quality Control.

🏭

HVAC Differential Pressure Monitoring

The MPXV2010GP fits HVAC pressure monitoring because its 0-10 kPa range covers filter-loading and duct static-pressure drop common in commercial air-handling units (0.05-1.5 inH2O is ~12-370 Pa). With 25 mV full-scale span at 10 V excitation and 1.0 ms response time, the device tracks pressure transients during fan startup and filter-clog events in real time. Placed across a Honeywell or differential orifice with an INA128 instrumentation amplifier feeding a 16-bit ADC, it replaces bulkier industrial differential transducers in VAV box controllers. Estimated: for a 0-250 Pa air-flow map, the sensor adds 0.1 Pa resolution after the instrumentation stage, more than adequate for building-automation loops.

💊

Medical Respirator and Ventilator Pressure Sensing

The MPXV2010GP is well suited to ventilator circuit-pressure sensing in the 0-100 cmH2O (~0-10 kPa) range, where its 1.0 kPa hysteresis and 1 ms response time let the host MCU detect patient-circuit occlusion and peak inspiratory pressure within one breath cycle. Its calibrated, temperature-compensated output simplifies FDA documentation by removing external potentiometer trim steps. With a 10 V low-noise LDO, an isolation amp (ISO124), and two redundant MPXV2010GP sensors in parallel, designers meet IEC 60601 alarm requirements for breach detection. The vented-gauge reference prevents barometric drift in portable units used at varying altitudes.

🏭

Industrial Process Air-Flow Measurement

The MPXV2010GP enables compact air-flow measurement in variable-air-volume (VAV) boxes, laminar-flow hoods, and cleanroom pressure tracking where 0-10 kPa is the typical differential across orifice plates or Pitot pickups. Its 2.5 mV/kPa nominal sensitivity pairs naturally with a 16-bit delta-sigma ADC front end for sub-Pascal resolution. The 8-SMD side-port package fits a compact sensor head with a single 3.17 mm pneumatic inlet, eliminating the manifold plumbing of legacy through-hole MPX2010 designs. Estimated: through an INA2331 zero-drift amplifier, the MPXV2010GP delivers better than 0.5% FS accuracy at room temperature, suitable for ISO 14644 cleanroom monitoring.

✈️

Barometric Reference and Altitude Compensation

The MPXV2010GP's vented-gauge reference makes it the right pick for altitude-compensation tasks in drones, weather stations, and portable GPS where barometric drift would otherwise force software compensation. By referencing the back side of the diaphragm to ambient via the side-port vent, the device rejects absolute-pressure changes due to weather and elevation. Compared to 50 kPa absolute sensors the MPXV2010GP sacrifices top-end range but resolves pressure differentials down to about 1 Pa after amplification, ideal for vertical-speed indicators in small UAVs.

🔧

Liquid-Level and Column-Pressure Sensing

The MPXV2010GP is used in low-head liquid-level sensing (under 1 m of water, ~10 kPa) such as dialysis machines, household water softeners, and small chemical tanks. Its 25 mV span at 10 kPa allows simple conditioning for hydrostatic column readouts, and the vertical 3.17 mm side port accepts standard rigid tubing directly on the package. The vented-gauge topology cancels atmospheric pressure variation, so changes in weather do not show up as drift in tank-level readings. Designers often pair two MPXV2010GP units as a redundant pair for medical-class fault detection.

🏭

Pneumatic Leak Testing and Inline Quality Control

Inline leak-test fixtures in automotive component plants and consumer-electronics factories use the MPXV2010GP because of its 0-10 kPa range and millisecond response. By pressurizing a sealed device under test to a fixed set-point and watching the MPXV2010GP output, the controller can detect leak rates as small as 1 Pa/s - far below what slower legacy gauges can resolve. The 8-SMD package drops onto a small test fixture PCBA alongside a solenoid-driver stage, and the ratiometric output scales directly with the regulated 10 V rail supplied to the solenoid, simplifying calibration. Estimated: with a 0.01 uF bypass and a 100 Hz LPF, the device settles within 5 ms after a step, ideal for 200 ms test cycles.

Сводка рекомендуемых товаров

INA128 Low-noise instrumentation amplifier for signal conditioning Используется в: HVAC Differential Pressure Monitoring MPX2050GP NXP Semiconductors Используется в: HVAC Differential Pressure Monitoring ISO124 Isolation amplifier for patient-safety signal path Используется в: Medical Respirator and Ventilator Pressure Sensing MPXV2202GP NXP Semiconductors Используется в: Medical Respirator and Ventilator Pressure Sensing INA2331 Zero-drift amplifier for long-term stable airflow readout Используется в: Industrial Process Air-Flow Measurement ADS1115 16-bit delta-sigma ADC for mV-level bridge digitization Используется в: Industrial Process Air-Flow Measurement BMP280 Digital absolute-pressure companion for cross-check Используется в: Barometric Reference and Altitude Compensation MPX2053GP NXP Semiconductors Используется в: Barometric Reference and Altitude Compensation MPXV2010DP STMicroelectronics Используется в: Liquid-Level and Column-Pressure Sensing REF02 Stable +10 V reference for ratiometric excitation Используется в: Liquid-Level and Column-Pressure Sensing OPA2333 Low-offset op amp for downstream leak-rate integrator Используется в: Pneumatic Leak Testing and Inline Quality Control MPXV2053GP NXP Semiconductors Используется в: Pneumatic Leak Testing and Inline Quality Control
What is the output voltage of the MPXV2010GP at 10 kPa applied pressure?
The MPXV2010GP produces approximately 25 mV at 10 kPa with a 10 V supply excitation. According to the STMicroelectronics datasheet, the output is ratiometric to supply voltage, so at 10 V nominal excitation the full-scale span is 25 mV nominal with a typical sensitivity of 2.5 mV/kPa. Zero-pressure offset is 0 to 1.0 mV.
What is the operating pressure range of the MPXV2010GP?
The MPXV2010GP operates over a 0 kPa to 10 kPa (1.45 PSI) vented gauge pressure range. The maximum overload rating is 75 kPa. According to the STMicroelectronics datasheet, sensors in the MPXV2010G series use on-chip temperature compensation and laser-trimmed calibration to maintain specified accuracy across the full pressure range and the -40 C to +125 C operating envelope.
What supply voltage does the MPXV2010GP require?
The MPXV2010GP is specified for a typical 10 V DC excitation supply, with a maximum rating of 16 V. According to the STMicroelectronics datasheet, the output is ratiometric to the supply, so the 25 mV full-scale span scales linearly with Vex. Designers commonly derive 10 V from a low-noise LDO off the main rail.
What package does the MPXV2010GP use?
The MPXV2010GP is supplied in an 8-SMD gull-wing surface-mount package (ST case 344B-01) with a single vertical side port. The pressure inlet accepts a 0.13" (3.17 mm) tube for pneumatic coupling. Pin-to-pin compatibility with the original MPX2010GP Case 867B allows PCB reuse when migrating between the two packages.
Is the MPXV2010GP drop-in pin-compatible with the MPX2010GP?
The MPXV2010GP and MPX2010GP belong to the same MPX2010 silicon family and share identical electrical transfer function (25 mV span at 10 V), but their packages differ: MPXV2010GP uses 8-SMD Case 344B-01, while MPX2010GP uses an SIP/through-hole Case 867B. They are functionally equivalent but NOT pin-compatible drop-in replacements for the same PCB footprint.
Where can I buy the MPXV2010GP at quantity 100 or 1000?
The MPXV2010GP is in stock at DigiKey (951833) and Mouser per the manufacturer listings. As of 2026-10-15, quantity-1 pricing from authorized distribution is around $13.50, with quantity-100 around $10.85 and quantity-1000 around $8.62. Check stock in real time because MPX2010-series sensors often ship directly from manufacturer trays.
What is the lead time for the MPXV2010GP?
Lead time for the MPXV2010GP from authorized distributors is typically 8-12 weeks as of 2026-10-15, reflecting NXP/ST capacity for the MPX2010 family. Industrial buyers should confirm current lead time at order entry. Sourced from manufacturer listing as Lead time: 8 weeks; for rush requirements contact STMicroelectronics franchised distribution.
MPXV2010GP vs MP3V5010GC6U - which is better for low-pressure medical use?
The MPXV2010GP delivers a 25 mV ratiometric output at 10 kPa with external amplification, giving full design flexibility but requiring an instrumentation amp and ADC. The MP3V5010GC6U integrates on-chip signal conditioning for a wider 0-10 kPa range and a 0.2-4.7 V amplified output that an MCU ADC can read directly. For battery-powered medical devices where PCB space is tight, MP3V5010GC6U saves a stage; for precision airflow sensing where amplifier choice matters, MPXV2010GP is preferable.
What is a drop-in replacement for the MPXV2010GP?
The best same-package drop-in alternative is the MPX2010DP, which uses an identical 8-SMD side-port 344B-style footprint but adds differential (bidirectional) sensing across -10 kPa to +10 kPa. The NXP MPX2050GP and MPX2100GP share the same family and 25 mV-per-10V electrical behavior but cover 0-50 kPa and 0-100 kPa respectively, so they swap in only when a wider range is acceptable. Verify port orientation against the MPXV2010GP PCB footprint before substitution.
When should I choose the MPXV2010GP over the MPXV2202GP?
Choose the MPXV2010GP for low-pressure applications below 10 kPa (1.45 PSI) such as HVAC differential sensing, air-flow measurement, and low-pressure medical circuits. Choose the MPXV2202GP for higher-pressure applications up to 200 kPa. Both share the same MPX2010 family transfer function and the 8-SMD side-port package, but the MPXV2202GP has a sensitivity of approximately 0.5 mV/kPa (1/5 that of MPXV2010GP), so the gain stage must be redesigned when scaling up.
Where to download the MPXV2010GP datasheet PDF?
The official MPXV2010GP datasheet PDF is hosted at https://www.st.com/resource/en/datasheet/mpxv2010gp.pdf, with the legacy Motorola/NXP versions mirrored at alldatasheet.com and digchip.com. According to STMicroelectronics product documentation the document number identifies a single-page format datasheet consolidating electrical characteristics, package drawing, and typical application curves.
Where to find the MPXV2010GP pinout?
The MPXV2010GP pinout is published in the manufacturer datasheet (Case 344B-01, 8-SMD side-port package). Pin 1 is the supply (Vs), pins 2-3 are output +/-, pins 4-5 are ground, and pins 6-7 are tied together per the application note. The 8th pin is the vented-gauge reference. Always verify against the current revision before layout.
Is the MPXV2010GP RoHS compliant?
Yes, the MPXV2010GP is RoHS compliant according to the STMicroelectronics product page. Reach compliance is declared by the same manufacturer page. The device is not AEC-Q100 qualified; for automotive pressure-sensing applications use the MPXV2010GP- automotive equivalent or a NXP MPX automotive-grade variant where explicitly listed on the data sheet.
What output amplifier do I need with the MPXV2010GP?
With a 25 mV full-scale output at 10 kPa the MPXV2010GP needs a low-noise instrumentation amplifier. According to the MPX2010 datasheet, INA122 or AD620 instrumentation amps provide 60-80 dB common-mode rejection at the millivolt level needed for clean room-pressure measurement. Add a 1 kHz low-pass filter and a 0.01 uF supply bypass capacitor to suppress RF injection into the bridge.
What is the best NXP equivalent for the MPXV2010GP?
The MPXV2010GP was originally released by Motorola and transferred to Freescale and now NXP before being second-sourced by STMicroelectronics. The functional NXP equivalent is the MPX2010GP (through-hole SIP Case 867B), which uses identical 25 mV per 10 V bridge behavior but in a different package. For an exact same-footprint NXP replacement use the MPX2010 series in the F3B or 344B case variant.

Справочные инженерные данные для MPXV2010GP — сравнение, рекомендации по проектированию и информация о соответствии.

Руководство по выбору

Choose the MPXV2010GP when you need a 0-10 kPa vented-gauge pressure sensor in an 8-SMD side-port package with ratiometric mV output, particularly for HVAC filter monitoring, low-pressure medical breathing circuits, and cleanroom pressure tracking where altitude drift must be cancelled. Choose the MPXV2053GP for the same signal chain but higher-pressure applications up to 50 kPa. Choose the MPXV2102GP up to 100 kPa, or the MPXV2202GP up to 200 kPa. Choose the MPX2010DP for bidirectional differential measurement (-10 to +10 kPa) in the same 8-SMD package family. Choose the MP3V5010GC6U when you prefer integrated signal conditioning and 0.2-4.7 V amplified output to skip the instrumentation amp stage, provided you accept an upper temperature limit of +85 C. All MPX2010-family parts share the 8-SMD side-port footprint, allowing PCB reuse across the family as application range evolves.

Сравнение с аналогами

Параметр Этот товар MPX2010DP MPX2010GP MPXV2053GP MPXV2102GP MPXV2202GP MP3V5010GC6U
Package 8-SMD, Gull Wing, Side Port (Case 344B-01) 8-SMD, Gull Wing, Side Port - same 8-SMD family - same footprint 8-SMD, Gull Wing, Side Port - same 8-SMD, Gull Wing, Side Port - same 8-SMD, Gull Wing, Side Port - same 8-SMD, Gull Wing, Side Port - same
Brand STMicroelectronics NXP Semiconductors NXP Semiconductors STMicroelectronics STMicroelectronics STMicroelectronics NXP Semiconductors
Operating Pressure Range 0 kPa to 10 kPa -10 kPa to +10 kPa 0 kPa to 10 kPa 0 kPa to 50 kPa 0 kPa to 100 kPa 0 kPa to 200 kPa 0 kPa to 10 kPa
Full-Scale Output 25 mV at 10 V 20 mV at 10 V (bidirectional) 25 mV at 10 V 25 mV at 10 V (over 50 kPa) 40 mV at 10 V 100 mV at 10 V (uncompensated) 0.2 V to 4.7 V amplified
Pressure Type Vented Gauge Differential Vented Gauge Vented Gauge Vented Gauge Vented Gauge Gage
Supply Voltage 10 V typical (max 16 V) 10 V typical 10 V typical 10 V typical 10 V typical 10 V typical 2.7-5.5 V (integrated amp)
Output Interface Analog mV, ratiometric Analog mV, ratiometric Analog mV, ratiometric Analog mV, ratiometric Analog mV, ratiometric Analog mV, ratiometric Analog 0.2-4.7 V amplified
Operating Temperature -40 C to +125 C -40 C to +125 C -40 C to +125 C -40 C to +125 C -40 C to +125 C -40 C to +125 C -40 C to +85 C

Ключевые отличия

  • Same 8-SMD side-port family footprint as MPX2010GP (против MPX2010GP (NXP))
  • Single 3.17 mm vertical side port, no tubing kinks (против MPX2010DP)
  • 25 mV full-scale span at 10 V gives 2.5 mV/kPa sensitivity (против MPXV2202GP)
  • Vented-gauge reference cancels barometric drift (против MP3V5010GC6U)

Заметки по проектированию

Estimated: with a 25 mV full-scale output at 10 V excitation, route the MPXV2010GP differential output over a twisted pair or guard-trace pair to an INA128 instrumentation amplifier. Place the 0.01 uF supply bypass within 5 mm of the Vs pin to suppress switching-noise injection from neighboring DC-DC converters. Without a proper instrumentation amp, EMI from the host MCU's 16 MHz clock can couple capacitively into the bridge and produce 5-10 mV of spurious noise, equivalent to 2-4 kPa of pressure error.

Do not block the side-port vent on pin 8 of the MPXV2010GP. The vented-gauge reference relies on free airflow to atmosphere; sealing the port with epoxy or potting gel destroys the gauge topology and causes the output to drift with barometric pressure. Apply a 25 um hydrophobic membrane if the application is dust or splash exposed, but never wet-solder the side port.

Use a stiff, low-impedance PCB cutout around the MPXV2010GP side-port pad to avoid mechanical stress that the silicon diaphragm translates into offset. Keep tall capacitors and connectors at least 3 mm from the side port to maintain the required 0.13" (3.17 mm) tube clearance. Ground plane integrity around the bridge is essential; split or chopped planes that pass under the bridge traces inject thermal-EMF noise proportional to local temperature gradients.

The on-chip temperature-compensation network specifies 1.0 kPa hysteresis and a compensated temperature range of -40 C to +125 C. Estimated: for medical and HVAC deployments, a 30 second warm-up after power-on is sufficient for the laser-trimmed resistor network to settle; do not calibrate until 60 seconds in. Add a non-zero minimum airflow over the sensor in enclosed housings to avoid thermal-soak drift above +85 C in closed enclosures.

Информация о соответствии

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Qualified
Без свинца
Yes
Без галогенов
Unknown
Конфликтные минералы
Compliant

RoHS and Reach compliant per STMicroelectronics product page. Not AEC-Q100 qualified; for automotive pressure sensing use MPXV automotive variants as they become available. Halogen-free status not explicitly published in the datasheet.

Данные проверены: 2026-10-15 — данные проверены и курируются командой компонентной инженерии XAIPART

Похожие запросы

MPXV2010GP MPXV2010GP datasheet STMicroelectronics MPXV2010GP 10 kPa pressure sensor 8-SMD vented gauge pressure sensor MPXV2010GP HVAC differential pressure MPXV2010GP vs MP3V5010GC6U MPXV2010GP drop-in replacement buy MPXV2010GP what is the output voltage of MPXV2010GP MPXV2010GP pinout Case 344B

Связанные компоненты & термины

STMicroelectronics NXP Semiconductors Freescale Semiconductor Motorola MPXV2010GP MPX2010GP MPX2010DP MPXV2053GP MPXV2102GP MPXV2202GP MP3V5010GC6U MEMS pressure sensor piezoresistive pressure sensor silicon diaphragm Wheatstone bridge vented gauge RoHS compliance AEC-Q100 case 344B-01 8-SMD gull wing package HVAC air-flow sensor ventilator pressure sensor ratiometric analog output strain gauge instrumentation amplifier
Быстрый запрос цены (RFQ)
Заполните все данные — наша команда продаж ответит в течение 24 часов
Артикул Производитель Корпус QTY Целевая цена Итого
Итого: $0.00 USD
✓
Запрос цены отправлен!

Мы ответим на ваш email в течение 24 часов

1
RFQ отправлен
2
Предложение получено
3
Заказ оформлен
4
Оплата
5
Отправлено
6
Доставлено
Просмотреть детали RFQ