±5 V to ±18 V Vdss 5 pA maximum Id 8-pin SOIC Package
MOQ: 1 |

OPA121KU Обзор

The Texas Instruments OPA121KU is a single precision operational amplifier with a 2 MHz gain-bandwidth product, 2 V/us slew rate, and ±5 V to ±18 V supply operation in an 8-pin SOIC package. It combines low-noise performance of 6 nV/√Hz typical at 10 kHz with maximum input bias current of 5 pA, making it suitable for precision signal chains with high-impedance sources.

An operational amplifier is an active analog building block that compares voltages applied to its inverting and non-inverting inputs and amplifies the difference. The OPA121 belongs to the broader precision operational amplifier hierarchy, where low offset, low drift, low noise, and high input impedance are more important than maximum bandwidth. Its DiFET-style input stage supports instrumentation applications requiring minimal source loading and low bias-current error.

Principal performance specifications include 6 nV/√Hz typical input-voltage noise density at 10 kHz, 5 pA maximum input bias current, 2 mV maximum input offset voltage, 3 uV/°C typical input offset drift, and 110 dB minimum open-loop gain. Common-mode rejection reaches 86 dB minimum. These characteristics support accurate amplification of small signals from photodetectors, transducers, high-impedance sensors, and precision data-acquisition systems.

The OPA121 uses a 2 MHz gain-bandwidth product and provides 2 V/us slew rate. Its bandwidth is sufficient for audio-frequency precision conditioning, industrial measurement, and low-frequency sensor interfaces, although it is not intended for high-speed video or RF signal chains. The single-amplifier configuration also reduces circuit area compared with a dual amplifier when only one gain stage is required.

Typical uses include optical communications receivers, photodiode amplifiers, instrumentation amplifiers, laboratory measurement systems, precision current-to-voltage converters, and low-level sensor conditioning. In these applications, low bias current limits error when operating with very high source impedances, while low voltage noise improves the signal-to-noise ratio of weak analog inputs.

PCB design should place the feedback network and input components close to the amplifier pins, provide a solid ground return, and maintain short, low-loop-area connections. Decoupling capacitors should be positioned at the supply pins, and unused inputs should be biased appropriately. Stability and usable bandwidth should be checked against the configured feedback impedance and the capacitance present at the output and inverting input.

This product page combines the principal OPA121KU specifications with drop-in replacement analysis, application guidance, pin-package constraints, and practical circuit-design notes. It is intended to help engineers identify whether this low-noise precision amplifier fits a particular instrumentation or signal-conditioning requirement.

Аналоги без доработки для OPA121KU — тот же корпус, pin-to-pin совместимость. Компоненты в других корпусах, требующие переработки PCB, исключены.

Варианты в этой серии

Модели той же серии, совместимые без доработки с OPA121KU (тот же форм-фактор и посадочное место) — отличается по Amplifier Type, Gain-Bandwidth Product, Slew Rate.

Texas Instruments
Amplifier Type: Precision low-noise DiFET operational amplifier
Gain-Bandwidth Product: 1.5 MHz
Slew Rate: 1.6 V/µs
Сравнить с OPA121KU →

OPA124U

✅ Прямая замена
Texas Instruments
📦 8-pin SOIC
Precision low-noise DiFET operational amplifier · 1 circuit · 1.5 MHz · 1.6 V/µs · 5 pA · 250 µV · 2 µV/°C · 120 dB

Уточнить цену

Открыть даташит →

OPA121KU Максимальные параметры и электрические характеристики

Amplifier Type 1 precision operational amplifier
Number of Circuits 1 circuit
Gain-Bandwidth Product 2 MHz
Slew Rate 2 V/us
Supply Voltage Range ±5 V to ±18 V
Input-Voltage Noise Density 6 nV/√Hz typical at 10 kHz
Input Bias Current 5 pA maximum
Input Offset Voltage 2 mV maximum
Input Offset Voltage Drift 3 uV/°C typical
Open-Loop Gain 110 dB minimum
Common-Mode Rejection Ratio 86 dB minimum
Корпус 8-pin SOIC
Тип монтажа Surface mount
Product Type Low-cost precision DiFET operational amplifier

Руководство по цоколевке OPA121KU в корпусе 8-pin soic

Цоколевка для OPA121KU (корпус 8-pin soic). Этот аналоговый компонент имеет выводы входа, выхода и питания. Обратитесь к техническому описанию производителя для конфигураций выводов балансировки нуля, коррекции и разрешения. Идеально подходит для схем обработки сигналов и усилителей.

Схема цоколевки корпуса 8-pin soic для OPA121KU

Нет подробных данных о распиновке для OPA121KU.

Обратитесь к даташиту для полной конфигурации выводов.

Типичное применение

OPA121KU подходит для 6 применениеs: Photodiode Signal Conditioning, Precision Instrumentation Amplifier, High-Impedance Sensor Interface, Low-Level Data Acquisition, Precision Current Measurement, Audio and Low-Frequency Analog Front End.

🌐

Photodiode Signal Conditioning

OPA121KU fits low-level photodiode amplification because its maximum input bias current of 5 pA limits the DC error introduced by very high photodiode impedances. Its 6 nV/√Hz typical input-voltage noise density at 10 kHz also helps preserve weak optical signals. A practical implementation uses the amplifier in a transimpedance topology, with the feedback resistor and compensation capacitor positioned close to pins 2 and 6. The 2 MHz gain-bandwidth product supports moderate-bandwidth photodiode systems, while 2 V/us slew rate helps preserve larger transient responses. Leakage through board contamination and guarding must be controlled because even picoamp-level board leakage can compete with the input bias current of the amplifier.

🏭

Precision Instrumentation Amplifier

OPA121KU is appropriate for instrumentation front ends that measure small differential voltages referenced near ground. The 2 mV maximum input offset voltage, 3 uV/°C typical drift, and 86 dB minimum common-mode rejection ratio help control error when the input level is small and the common-mode voltage varies. Two OPA121KU devices can form a classic three-op-amp instrumentation stage, while one device can amplify a single-ended sensor output. Its 5 pA maximum bias current is especially useful when the source impedance is high. Verify resistor ratios and common-mode headroom for the intended sensor range, and use matched, low-temperature-coefficient networks when gain accuracy is more important than the intrinsic offset specification.

🧩

High-Impedance Sensor Interface

OPA121KU suits electrochemical, capacitive, and other high-impedance sensors because the 5 pA maximum input bias current creates less input-loading error than a bipolar-input amplifier. The low-noise input stage supports accurate conditioning of slowly varying sensor outputs, while the 2 MHz gain-bandwidth product provides more bandwidth than is normally required for many temperature or chemical measurements. The main design limit is total input capacitance rather than bandwidth alone. Keep feedback-loop capacitance controlled, use guarding around sensitive input nodes, and consider the bias-current contribution of the sensor, PCB, humidity, and protection diodes. A low-leakage input clamp is especially important when leakage and input bias current are comparable.

🖥️

Low-Level Data Acquisition

OPA121KU can condition low-level inputs in precision data-acquisition systems where noise and drift determine the usable resolution. Its 6 nV/√Hz typical input-voltage noise density at 10 kHz, 110 dB minimum open-loop gain, and 2 mV maximum offset support accurate amplification before digitization. The 2 MHz gain-bandwidth product is suitable for many multiplexed industrial measurement channels operating below audio or low-megahertz bandwidths. Use short traces, a quiet ground plane, and separate analog and digital return currents to prevent converter switching noise from entering the signal path. The selected ADC should present an input network that remains stable with the OPA121KU feedback configuration, and the complete signal chain should be noise-gain optimized rather than relying on voltage gain alone.

⚡

Precision Current Measurement

OPA121KU is useful in current-measurement circuits where a small voltage across a sense element must be amplified accurately. The amplifier's low input bias current reduces errors in high-resistance sensing paths, and its 110 dB minimum open-loop gain provides high forward gain in non-inverting configurations. Its 2 V/us slew rate is adequate for many control and monitoring signals, although bandwidth should be checked against the fastest transient. Place the sense-element connections close together, keep the amplifier input nodes compact, and avoid sharing high-current return paths with sensitive analog traces. Input filtering must preserve the intended measurement bandwidth while limiting RF pickup. For systems with high common-mode voltage or substantial transients, confirm the input common-mode and supply limits against the actual operating condition.

🎧

Audio and Low-Frequency Analog Front End

OPA121KU can serve as a precision low-frequency gain stage in audio and laboratory analog circuits. Its 2 MHz gain-bandwidth product, 2 V/us slew rate, and 86 dB minimum common-mode rejection provide useful performance for microphone, line-level, and active-filter stages operating well below the upper bandwidth limit. The 6 nV/√Hz typical noise density at 10 kHz is particularly useful for quiet microphone amplification and low-level audio paths. Gain-setting resistors should be low enough to avoid excess Johnson noise but not so low that loading or stability becomes difficult. Keep the feedback loop compact, use a clean analog ground connection, and provide local supply bypassing. Verify output swing, load impedance, and capacitive loading before placing the amplifier directly at a connector or long cable.

Where can I buy OPA121KU online?
The OPA121KU can be requested through the Request a Quote form on this page. The exact orderable part is a single Texas Instruments precision operational amplifier in an 8-pin SOIC package. Quote requests should specify the required quantity, shipment destination, and whether reel, tube, or another approved delivery format is needed. The form is the appropriate channel for current pricing, stock confirmation, and delivery scheduling without relying on an outdated catalog figure.
What is the price of OPA121KU?
Use the Request a Quote form on this page for the current OPA121KU price and quantity breaks. The part is a Texas Instruments 8-pin SOIC precision operational amplifier, and commercial terms can change with volume, inventory, packaging, and destination. The quote form provides the current purchasing path for the exact OPA121KU MPN instead of presenting a stale price that may no longer represent orderable supply.
What is the lead time for OPA121KU?
Request the current OPA121KU lead time through the Request a Quote form on this page. Lead time depends on the requested quantity, package delivery format, manufacturing availability, and destination country. For prototype quantities, state the target build date; for production quantities, include the annual usage forecast so the supplier can confirm realistic allocation and replenishment timing.
Is OPA121KU in stock?
Confirm OPA121KU stock status through the Request a Quote form on this page. Inventory should be checked against the exact 8-pin SOIC ordering code and the required delivery format rather than inferred from a family-level listing. Providing a target quantity, shipment destination, and production schedule in the request enables a direct answer about current availability, allocation, and expected dispatch timing.
OPA121KU vs OPA124U: which is better for precision instrumentation?
OPA121KU is the lower-cost 2 MHz precision choice, while OPA124U belongs to a higher-performance precision-amplifier family. The OPA121KU provides 2 MHz gain-bandwidth product, 2 V/us slew rate, 6 nV/√Hz typical noise at 10 kHz, and 5 pA maximum bias current. The OPA124U may be preferable when its specific noise, drift, bandwidth, and output-drive ratings justify the additional cost, but complete pin and specification verification is required before substitution.
What is the difference between OPA121KU and OPA124U?
The principal difference is positioning: OPA121KU is a low-cost precision DiFET operational amplifier, whereas OPA124U is positioned as a higher-performance precision monolithic FET operational amplifier. The confirmed OPA121KU specifications include 2 MHz bandwidth, 2 V/us slew rate, 6 nV/√Hz noise at 10 kHz, 5 pA maximum bias current, 2 mV maximum offset, and 86 dB minimum CMRR. Compare the complete manufacturer specifications before making a board-level replacement.
When should I choose OPA121KU over OPA124U?
Choose OPA121KU when the design needs a low-noise, very-low-bias-current precision amplifier but does not require the higher performance associated with OPA124U. Its 2 MHz gain-bandwidth product is appropriate for low-level instrumentation and sensor conditioning, while 6 nV/√Hz noise at 10 kHz and 5 pA maximum bias current help protect weak signals from source and amplifier noise. Choose OPA124U when its documented ratings justify a premium for the target circuit.
Is OPA121KU suitable for high-impedance sensor interfaces?
OPA121KU is suitable for high-impedance sensor interfaces when the signal bandwidth is compatible with its 2 MHz gain-bandwidth product. Its 5 pA maximum input bias current produces very little DC error with high-source-impedance sensors, and its 6 nV/√Hz typical noise density at 10 kHz supports low-level signal conditioning. Account for input capacitance, leakage, guard rings, and the noise contribution of external resistors when setting the practical input-impedance limit.
What can replace OPA121KU?
OPA124U is the directly identified 8-pin SOIC candidate for comparison with OPA121KU, but it should be treated as a reviewed substitute rather than an automatic equivalent. A valid replacement must preserve the SOIC pin arrangement, supply range, input common-mode limits, offset behavior, bias current, noise, stability, and required bandwidth. The OPA121KU has 2 MHz gain-bandwidth product, 2 V/us slew rate, and 5 pA maximum bias current; verify each requirement before changing the BOM.
Where can I download the OPA121KU datasheet PDF?
The Texas Instruments OPA121KU datasheet PDF is available through the manufacturer link on this page. The document describes the OPA121 low-cost precision DiFET operational amplifier and covers the 8-pin SOIC ordering information, electrical characteristics, noise, offset, bias current, common-mode behavior, and application guidance. Use the pin-description table and ordering information in that datasheet when assigning PCB tracks or creating an approved alternate BOM.
Where can I find the OPA121KU pinout?
Use the pin-description table in the Texas Instruments OPA121 datasheet to locate the OPA121KU pinout and verify power, input, output, and no-connect assignments. The component is supplied in an 8-pin SOIC package, but a package drawing alone does not establish the functional pin names. Confirm the exact manufacturer diagram before routing the PCB, especially around supply pins and no-connect positions.
What are the key specifications of OPA121KU that engineers should know?
OPA121KU is a single 8-pin SOIC precision operational amplifier rated for ±5 V to ±18 V supplies. Key electrical values include 2 MHz gain-bandwidth product, 2 V/us slew rate, 6 nV/√Hz typical input-voltage noise density at 10 kHz, 5 pA maximum bias current, 2 mV maximum offset voltage, 3 uV/°C typical offset drift, 110 dB minimum open-loop gain, and 86 dB minimum CMRR.
Is OPA121KU the same as OPA124U?
No. OPA121KU and OPA124U are related precision operational amplifiers, but they are positioned in different performance families. OPA121KU is the low-cost precision model with 2 MHz bandwidth, 6 nV/√Hz typical noise at 10 kHz, and 5 pA maximum input bias current. OPA124U is a higher-performance precision FET amplifier. Treat them as alternatives requiring specification and stability review, not identical devices.
What is the best Analog Devices equivalent for OPA121KU?
No Analog Devices equivalent can be identified responsibly from the available cross-reference material for OPA121KU. A defensible substitute must use the same 8-pin SOIC pin arrangement and meet the target circuit's requirements for ±5 V to ±18 V operation, 5 pA-class bias current, 6 nV/√Hz-class noise, 2 MHz bandwidth, common-mode range, offset drift, and stability. Submit the candidate MPN for a formal comparison before approving a cross-brand replacement.
What is the best drop-in replacement for OPA121KU?
OPA124U is the strongest identified candidate for an 8-pin SOIC replacement review, but the available cross-reference information does not establish it as a no-change substitute. OPA121KU combines a 2 MHz gain-bandwidth product, 2 V/us slew rate, 5 pA maximum bias current, and ±5 V to ±18 V operation. Verify the OPA124U pinout, supply behavior, common-mode range, stability, noise, offset, and lifecycle before using it as a drop-in replacement.

Справочные инженерные данные для OPA121KU — сравнение, рекомендации по проектированию и информация о соответствии.

Руководство по выбору

Choose OPA121KU when the design requires a single, low-noise precision amplifier with very low input bias current, modest bandwidth, and an 8-pin SOIC footprint. It is a strong fit for photodiode interfaces, high-impedance sensors, instrumentation, and low-level audio or measurement circuits. Choose OPA124U when its higher-performance precision-amplifier characteristics provide measurable value and the complete specifications confirm compatibility with the required supply voltage, common-mode range, noise, offset, drift, and stability. Do not treat OPA124U as an automatic substitute without checking the pin configuration and dynamic performance. If the circuit requires greater bandwidth, lower offset, lower drift, stronger output drive, or a different supply range than the OPA121KU provides, review the relevant manufacturer families rather than forcing a board-level replacement.

Сравнение с аналогами

Параметр Этот товар OPA124U
Brand Texas Instruments Texas Instruments
Package 8-pin SOIC 8-pin SOIC

Ключевые отличия

  • Very low input bias current supports high-source-impedance measurement (против OPA124U)
  • Low-noise precision performance in an economical single-amplifier package (против OPA124U)
  • Bandwidth and slew rate suit low-level precision signal chains (против OPA124U)

Заметки по проектированию

Route the inverting input, feedback components, and non-inverting input as compact, quiet nets. High-value precision nodes should be surrounded by analog ground where appropriate, while high-current or switching paths should remain physically separate. Place input protection components close to the connector, but account for their leakage and capacitance because the OPA121KU input bias current is only 5 pA maximum. Guarding can help isolate a sensitive input when board contamination or humidity produces leakage comparable with the signal current.

Do not assume the 2 MHz gain-bandwidth product is the only stability constraint. The usable bandwidth and peaking depend on the noise gain, feedback resistance, source impedance, and capacitance connected to the output and inverting input. Simulate the final network and add compensation only after accounting for the PCB and external capacitance. Also verify output swing at the intended load, because the input and output limits can be reached before the nominal supply rails.

Keep the OPA121KU input bias current and noise benefits from being undermined by leakage or excessive feedback resistance. Use high-quality, low-leakage protection components for very high source impedances and avoid long exposed input traces. The amplifier contributes 6 nV/√Hz typical input-voltage noise at 10 kHz, but resistor noise and thermal drift can dominate when the closed-loop gain is low. Recalculate the total noise and offset budget after adding external resistors, input filters, and ADC input circuitry.

Place local supply-bypass capacitors close to the supply pins and connect them to the quiet ground reference with short traces. The OPA121KU operates from ±5 V to ±18 V, but the usable signal range can be narrower because of input common-mode and output-swing limits. Keep the bypass network independent from high-current return paths, inspect supply ripple at the device, and ensure the source can support the required output current without adding noise or instability to the analog rail.

Информация о соответствии

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Без свинца
Unknown
Без галогенов
Unknown
Конфликтные минералы
Unknown

Compliance status was not identified in the manufacturer or distributor material and must be confirmed from the current manufacturer product documentation before procurement.

Данные проверены: 2026-11-19 — данные проверены и курируются командой компонентной инженерии XAIPART

Похожие запросы

OPA121KU OPA121KU datasheet OPA121KU datasheet pdf OPA121KU pinout OPA121KU specifications OPA121KU equivalent OPA121KU replacement OPA121KU vs OPA124U OPA121KU SOIC-8 pinout OPA121KU price OPA121KU stock OPA121KU low noise op amp

Связанные компоненты & термины

Texas Instruments OPA121KU OPA121 OPA124U precision operational amplifier low-noise operational amplifier DiFET operational amplifier analog IC integrated circuit signal conditioning instrumentation amplifier photodiode amplifier transimpedance amplifier high-impedance sensor interface input bias current input-voltage noise density open-loop gain common-mode rejection ratio gain-bandwidth product slew rate 8-pin SOIC SOIC package family surface-mount package precision measurement low-level analog signal
Быстрый запрос цены (RFQ)
Заполните все данные — наша команда продаж ответит в течение 24 часов
Артикул Производитель Корпус QTY Целевая цена Итого
✓
Запрос цены отправлен!

Мы ответим на ваш email в течение 24 часов

1
RFQ отправлен
2
Предложение получено
3
Заказ оформлен
4
Оплата
5
Отправлено
6
Доставлено
Просмотреть детали RFQ