OPA121KU - 2MHz Low-Noise Precision Op Amp | Texas Instruments
부품 번호: OPA121KU ✓ 활성OPA121KU 개요
An operational amplifier is an active analog building block that compares voltages applied to its inverting and non-inverting inputs and amplifies the difference. The OPA121 belongs to the broader precision operational amplifier hierarchy, where low offset, low drift, low noise, and high input impedance are more important than maximum bandwidth. Its DiFET-style input stage supports instrumentation applications requiring minimal source loading and low bias-current error.
Principal performance specifications include 6 nV/√Hz typical input-voltage noise density at 10 kHz, 5 pA maximum input bias current, 2 mV maximum input offset voltage, 3 uV/°C typical input offset drift, and 110 dB minimum open-loop gain. Common-mode rejection reaches 86 dB minimum. These characteristics support accurate amplification of small signals from photodetectors, transducers, high-impedance sensors, and precision data-acquisition systems.
The OPA121 uses a 2 MHz gain-bandwidth product and provides 2 V/us slew rate. Its bandwidth is sufficient for audio-frequency precision conditioning, industrial measurement, and low-frequency sensor interfaces, although it is not intended for high-speed video or RF signal chains. The single-amplifier configuration also reduces circuit area compared with a dual amplifier when only one gain stage is required.
Typical uses include optical communications receivers, photodiode amplifiers, instrumentation amplifiers, laboratory measurement systems, precision current-to-voltage converters, and low-level sensor conditioning. In these applications, low bias current limits error when operating with very high source impedances, while low voltage noise improves the signal-to-noise ratio of weak analog inputs.
PCB design should place the feedback network and input components close to the amplifier pins, provide a solid ground return, and maintain short, low-loop-area connections. Decoupling capacitors should be positioned at the supply pins, and unused inputs should be biased appropriately. Stability and usable bandwidth should be checked against the configured feedback impedance and the capacitance present at the output and inverting input.
This product page combines the principal OPA121KU specifications with drop-in replacement analysis, application guidance, pin-package constraints, and practical circuit-design notes. It is intended to help engineers identify whether this low-noise precision amplifier fits a particular instrumentation or signal-conditioning requirement.
드롭인 대체품: OPA121KU — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.
이 시리즈의 변형
다음과 드롭인 호환되는 동일 시리즈 모델: OPA121KU (동일 폼 팩터 및 풋프린트) — 차이점: Amplifier Type, Gain-Bandwidth Product, Slew Rate.
OPA124U
✅ 드롭인가격 문의
데이터시트 보기 →OPA121KU 최대 정격 & 전기적 특성
| Amplifier Type | 1 precision operational amplifier |
| Number of Circuits | 1 circuit |
| Gain-Bandwidth Product | 2 MHz |
| Slew Rate | 2 V/us |
| Supply Voltage Range | ±5 V to ±18 V |
| Input-Voltage Noise Density | 6 nV/√Hz typical at 10 kHz |
| Input Bias Current | 5 pA maximum |
| Input Offset Voltage | 2 mV maximum |
| Input Offset Voltage Drift | 3 uV/°C typical |
| Open-Loop Gain | 110 dB minimum |
| Common-Mode Rejection Ratio | 86 dB minimum |
| 패키지 | 8-pin SOIC |
| 실장 유형 | Surface mount |
| Product Type | Low-cost precision DiFET operational amplifier |
OPA121KU 8-pin soic 핀 구성 가이드
OPA121KU(8-pin soic 패키지)의 핀 구성입니다. 이 아날로그 부품에는 입력, 출력, 전원 공급 핀이 있습니다. 오프셋 널, 보상, 인에이블 핀 구성은 제조사 데이터시트를 참조하십시오. 신호 컨디셔닝 및 증폭기 회로에 이상적입니다.
다음에 대한 상세 핀아웃 데이터 없음: OPA121KU.
다음을 참조하십시오: 데이터시트 전체 핀 구성은 다음을 참조하십시오.
일반적인 애플리케이션
OPA121KU 적합 용도: 6 애플리케이션s: Photodiode Signal Conditioning, Precision Instrumentation Amplifier, High-Impedance Sensor Interface, Low-Level Data Acquisition, Precision Current Measurement, Audio and Low-Frequency Analog Front End.
Photodiode Signal Conditioning
OPA121KU fits low-level photodiode amplification because its maximum input bias current of 5 pA limits the DC error introduced by very high photodiode impedances. Its 6 nV/√Hz typical input-voltage noise density at 10 kHz also helps preserve weak optical signals. A practical implementation uses the amplifier in a transimpedance topology, with the feedback resistor and compensation capacitor positioned close to pins 2 and 6. The 2 MHz gain-bandwidth product supports moderate-bandwidth photodiode systems, while 2 V/us slew rate helps preserve larger transient responses. Leakage through board contamination and guarding must be controlled because even picoamp-level board leakage can compete with the input bias current of the amplifier.
추천
Precision Instrumentation Amplifier
OPA121KU is appropriate for instrumentation front ends that measure small differential voltages referenced near ground. The 2 mV maximum input offset voltage, 3 uV/°C typical drift, and 86 dB minimum common-mode rejection ratio help control error when the input level is small and the common-mode voltage varies. Two OPA121KU devices can form a classic three-op-amp instrumentation stage, while one device can amplify a single-ended sensor output. Its 5 pA maximum bias current is especially useful when the source impedance is high. Verify resistor ratios and common-mode headroom for the intended sensor range, and use matched, low-temperature-coefficient networks when gain accuracy is more important than the intrinsic offset specification.
추천
High-Impedance Sensor Interface
OPA121KU suits electrochemical, capacitive, and other high-impedance sensors because the 5 pA maximum input bias current creates less input-loading error than a bipolar-input amplifier. The low-noise input stage supports accurate conditioning of slowly varying sensor outputs, while the 2 MHz gain-bandwidth product provides more bandwidth than is normally required for many temperature or chemical measurements. The main design limit is total input capacitance rather than bandwidth alone. Keep feedback-loop capacitance controlled, use guarding around sensitive input nodes, and consider the bias-current contribution of the sensor, PCB, humidity, and protection diodes. A low-leakage input clamp is especially important when leakage and input bias current are comparable.
추천
Low-Level Data Acquisition
OPA121KU can condition low-level inputs in precision data-acquisition systems where noise and drift determine the usable resolution. Its 6 nV/√Hz typical input-voltage noise density at 10 kHz, 110 dB minimum open-loop gain, and 2 mV maximum offset support accurate amplification before digitization. The 2 MHz gain-bandwidth product is suitable for many multiplexed industrial measurement channels operating below audio or low-megahertz bandwidths. Use short traces, a quiet ground plane, and separate analog and digital return currents to prevent converter switching noise from entering the signal path. The selected ADC should present an input network that remains stable with the OPA121KU feedback configuration, and the complete signal chain should be noise-gain optimized rather than relying on voltage gain alone.
추천
Precision Current Measurement
OPA121KU is useful in current-measurement circuits where a small voltage across a sense element must be amplified accurately. The amplifier's low input bias current reduces errors in high-resistance sensing paths, and its 110 dB minimum open-loop gain provides high forward gain in non-inverting configurations. Its 2 V/us slew rate is adequate for many control and monitoring signals, although bandwidth should be checked against the fastest transient. Place the sense-element connections close together, keep the amplifier input nodes compact, and avoid sharing high-current return paths with sensitive analog traces. Input filtering must preserve the intended measurement bandwidth while limiting RF pickup. For systems with high common-mode voltage or substantial transients, confirm the input common-mode and supply limits against the actual operating condition.
추천
Audio and Low-Frequency Analog Front End
OPA121KU can serve as a precision low-frequency gain stage in audio and laboratory analog circuits. Its 2 MHz gain-bandwidth product, 2 V/us slew rate, and 86 dB minimum common-mode rejection provide useful performance for microphone, line-level, and active-filter stages operating well below the upper bandwidth limit. The 6 nV/√Hz typical noise density at 10 kHz is particularly useful for quiet microphone amplification and low-level audio paths. Gain-setting resistors should be low enough to avoid excess Johnson noise but not so low that loading or stability becomes difficult. Keep the feedback loop compact, use a clean analog ground connection, and provide local supply bypassing. Verify output swing, load impedance, and capacitive loading before placing the amplifier directly at a connector or long cable.
추천
추천 제품 요약
엔지니어링 참조 데이터: OPA121KU — 비교, 설계 지침 및 규정 준수 정보.
선택 가이드
대체품과의 비교
| 파라미터 | 이 제품 | OPA124U |
|---|---|---|
| Brand | Texas Instruments | Texas Instruments |
| Package | 8-pin SOIC | 8-pin SOIC |
주요 차별점
- Very low input bias current supports high-source-impedance measurement (vs OPA124U)
- Low-noise precision performance in an economical single-amplifier package (vs OPA124U)
- Bandwidth and slew rate suit low-level precision signal chains (vs OPA124U)
설계 노트
Route the inverting input, feedback components, and non-inverting input as compact, quiet nets. High-value precision nodes should be surrounded by analog ground where appropriate, while high-current or switching paths should remain physically separate. Place input protection components close to the connector, but account for their leakage and capacitance because the OPA121KU input bias current is only 5 pA maximum. Guarding can help isolate a sensitive input when board contamination or humidity produces leakage comparable with the signal current.
Do not assume the 2 MHz gain-bandwidth product is the only stability constraint. The usable bandwidth and peaking depend on the noise gain, feedback resistance, source impedance, and capacitance connected to the output and inverting input. Simulate the final network and add compensation only after accounting for the PCB and external capacitance. Also verify output swing at the intended load, because the input and output limits can be reached before the nominal supply rails.
Keep the OPA121KU input bias current and noise benefits from being undermined by leakage or excessive feedback resistance. Use high-quality, low-leakage protection components for very high source impedances and avoid long exposed input traces. The amplifier contributes 6 nV/√Hz typical input-voltage noise at 10 kHz, but resistor noise and thermal drift can dominate when the closed-loop gain is low. Recalculate the total noise and offset budget after adding external resistors, input filters, and ADC input circuitry.
Place local supply-bypass capacitors close to the supply pins and connect them to the quiet ground reference with short traces. The OPA121KU operates from ±5 V to ±18 V, but the usable signal range can be narrower because of input common-mode and output-swing limits. Keep the bypass network independent from high-current return paths, inspect supply ripple at the device, and ensure the source can support the required output current without adding noise or instability to the analog rail.
규정 준수 정보
Compliance status was not identified in the manufacturer or distributor material and must be confirmed from the current manufacturer product documentation before procurement.