A SLIC, or Subscriber Line Interface Circuit, is the analog front end that connects a telephone line to a digital voice processor. It performs line-state monitoring, hook detection, ring detection, impedance control, DC feed, and overvoltage protection. In a ProSLIC architecture, the SLIC and voice codec are combined to reduce external components while providing a complete dual-channel line interface for central-office equipment, Voice over Packet equipment, and legacy telephone adapters.
The SI3225-G-GQ supports two circuits and is specified for both 3.3 V and 5 V supply operation. Its reported 65 mA supply current supports low-power line-interface designs. The device also implements the BORSCHT functions used for off-hook and on-hook line supervision. External bulk-ringer support distinguishes this device from SLIC variants that generate ringing internally.
The GCI interface supports direct connection to a DSP, while PCM and SPI interfaces provide additional digital connectivity options. Internal diagnostics assist development and production testing by helping identify line-interface operating conditions. The 64-TQFP package provides 64 external connections for two complete analog channels and their associated digital control, power, and interface signals.
Typical uses include central-office line-card assemblies, digital subscriber line equipment, Voice over IP media gateways, embedded telephony controllers, and multi-channel analog telephone adapters. The dual-channel architecture is particularly useful when the surrounding system must handle two subscriber lines while maintaining a common digital backplane and control interface.
Layout should prioritize short analog line paths, proper return connections, and compliant isolation or protection networks. Use the manufacturer's pin-description table, application schematic, and layout guidance when assigning tracks because the analog line pins are sensitive to parasitic capacitance, surge transients, and ground-current coupling. Decoupling and protection components should follow the recommended values and placement shown in the manufacturer documentation.
Аналоги без доработки для SI3225-G-GQ — тот же корпус, pin-to-pin совместимость. Компоненты в других корпусах, требующие переработки PCB, исключены.
Варианты в этой серии
Модели той же серии, совместимые без доработки с SI3225-G-GQ (тот же форм-фактор и посадочное место) — отличается по Package, Product Type.
SI3225-G-GQR
✅ Прямая замена📋 Справочный аналог (нет в каталоге)
SI3225-G-FQR
✅ Прямая замена📋 Справочный аналог (нет в каталоге)
SI3225-GQ
✅ Прямая заменаУточнить цену
Открыть даташит →SI3225-G-GQ Характеристики
| Product Type | Dual-channel SLIC/codec interface IC |
| Number of Circuits | 2 circuits |
| Digital Interfaces | GCI, PCM, and SPI |
| Supply Voltage Options | 3.3 V and 5 V |
| Ток потребления | 65 mA |
| Power Dissipation | 941 mW |
| Диапазон рабочих температур | -40 °C to +85 °C |
| Корпус | 64-pin TQFP, 10 mm × 10 mm |
| Тип монтажа | Surface mount |
| Ringing Support | External bulk-ringer support |
| Line Functions | BORSCHT functions |
| Analog Line Support | Dual balanced and unbalanced ringing line functions |
| Diagnostics | Internal diagnostics |
| Lead-Free Status | Lead-free |
| Automotive Qualification | Not applicable |
Руководство по цоколевке SI3225-G-GQ в корпусе 64-pin tqfp, 10 mm × 10 mm
Цоколевка для SI3225-G-GQ (корпус 64-pin tqfp, 10 mm × 10 mm). Нумерация выводов, функции и схемы подключения определены в техническом описании производителя. Обратитесь к нему для точного посадочного места и рекомендаций по пайке.
Нет подробных данных о распиновке для SI3225-G-GQ.
Обратитесь к даташиту для полной конфигурации выводов.
Типичное применение
SI3225-G-GQ подходит для 6 применениеs: Voice over IP Media Gateway, Central Office Line Card, Analog Telephone Adapter, PBX Line Interface Module, Industrial VoIP Station, Voice Testing and Diagnostic Equipment.
Voice over IP Media Gateway
The SI3225-G-GQ fits a two-line Voice over IP media gateway because it integrates both subscriber-line interface circuits and codec functionality on one device. Its GCI, PCM, and SPI interfaces allow the gateway to connect through the digital architecture selected for the host DSP or communications processor. With a specified 65 mA supply current, the device supports two lines without requiring two separate SLIC packages. The host software must implement BORSCHT control, hook and ring-state reporting, line impedance management, and the selected digital framing format.
Рекомендуется
Central Office Line Card
The SI3225-G-GQ can terminate two analog subscriber lines on a central-office line card while sharing a common DSP backplane. Its 64-pin TQFP arrangement provides separate analog line connections together with GCI, PCM, and SPI control paths, allowing the card to support multiple line-processing modes. The external bulk-ringer feature is useful when the card architecture centralizes ringing generation. For field deployment, the line interface must be combined with the appropriate overvoltage, surge, isolation, and longitudinal balance networks.
Рекомендуется
Analog Telephone Adapter
In an analog telephone adapter, the SI3225-G-GQ provides two line interfaces for connecting traditional handsets or fax equipment to a digital voice system. Integrating the SLIC and codec functions reduces the number of separate analog interface components, while GCI permits direct DSP control. The device's 3.3 V and 5 V supply options support varied telecommunications system architectures. Firmware should validate line-state transitions, ring cadence, voice-path startup, and impedance settings before enabling the adapter for field use.
Рекомендуется
PBX Line Interface Module
The SI3225-G-GQ is suitable for a two-channel PBX line module that must handle hook status, ring detection, DC feed, and analog voice termination. Its BORSCHT functions give the system a consistent hardware basis for line supervision, and the SPI or PCM connection can be used when the module architecture does not use GCI. Two channels per package can simplify routing and component placement compared with separate single-line devices. Production validation should include worst-case line current, off-hook impedance, ring voltage, and voice distortion under representative cable lengths.
Рекомендуется
Industrial VoIP Station
The SI3225-G-GQ can support an industrial VoIP station requiring two analog endpoints for legacy handsets, paging equipment, or analog peripherals. Its -40 °C to +85 °C operating range suits temperature-controlled industrial equipment, and internal diagnostics assist commissioning and fault isolation. Because the analog lines are exposed to ESD, ringing transients, and ground potential differences, the protection network must be designed around the application. The 10 mm by 10 mm TQFP also requires thermal-aware placement and a clean return path to the system ground plane.
Рекомендуется
Voice Testing and Diagnostic Equipment
The SI3225-G-GQ can be used in line-interface test equipment because it provides two controllable subscriber-line channels and internal diagnostics. GCI or PCM connectivity allows automated equipment to exercise hook, ring, DC-feed, and line-impedance conditions through the host controller. Dual-channel operation enables parallel testing without duplicating the complete front end. The test system must still account for real line voltage, current, and ringing exposure by using suitable protection and isolation networks. Diagnostic readings should be interpreted according to the manufacturer test and calibration procedure.
Рекомендуется
Сводка рекомендуемых товаров
Справочные инженерные данные для SI3225-G-GQ — сравнение, рекомендации по проектированию и информация о соответствии.
Руководство по выбору
Сравнение с аналогами
| Параметр | Этот товар | SI3225-G-GQR | SI3225-G-FQR | SI3225-GQ |
|---|---|---|---|---|
| Package | 64-pin TQFP (10 mm × 10 mm) | 64-pin TQFP (10 mm × 10 mm) | 64-pin TQFP (10 mm × 10 mm) | 64-pin TQFP (10 mm × 10 mm) |
| Brand | Silicon Labs | Skyworks Solutions | Skyworks Solutions | Silicon Labs |
| Device Function | Dual-channel SLIC/codec | Dual-channel SLIC/codec | Dual-channel SLIC/codec | Dual-channel SLIC/codec |
Ключевые отличия
- Two complete subscriber-line channels in one package (против SI3225-GQ)
- Three digital connectivity options (против SI3225-G-FQR)
- External bulk-ringer support and internal diagnostics (против SI3225-G-GQR)
- Specified operation across industrial temperatures (против SI3225-G-FQR)
Заметки по проектированию
Use the manufacturer application schematic and pin-description table to assign the 64 TQFP connections. Keep the two analog subscriber-line channels away from high-speed digital edges and switching-node return currents. Route each line as a matched, balanced pair where applicable, minimize stub lengths, and provide a continuous ground reference beneath the analog section. Confirm creepage and clearance against the protection devices and the highest applicable ringing or surge voltage.
Place the required bypass capacitors close to their associated supply and ground pins using the shortest possible ground-return path. Separate noisy digital return currents from the analog line circuitry and keep the 3.3 V or 5 V supply distribution controlled by the same decoupling recommendations that apply to the manufacturer reference design. Validate startup, shutdown, and supply-transient behavior in the complete line card rather than relying only on bench supply measurements.
Do not treat a similar SLIC/codec family member as interchangeable without checking line-region behavior, DSP firmware support, interface timing, and ordering codes. The SI3225-G-GQ requires GCI, PCM, or SPI compatibility as well as correct BORSCHT configuration. Also verify whether the board uses an external bulk ringer; internal-ringer variants can use different enabling procedures and protection assumptions, even when their package dimensions match.
Use the PCB thermal design and exposed-pad requirements specified by the manufacturer. The published maximum power dissipation is 941 mW, which can raise the junction temperature substantially if heat cannot escape through the package and board copper. Provide uninterrupted ground-plane area under the device where applicable, minimize thermal voids, and avoid placing it directly above heat-generating components. Confirm the operating-temperature margin in the worst ambient and line-power condition.
Информация о соответствии
The product listings identify the device as lead-free. No explicit RoHS, REACH, halogen-free, or conflict-minerals declaration was identified.