SP485CN-L - 5Mbps Half-Duplex RS-485 IC | MaxLinear
Артикул: SP485CN-L ✓ Активен| Кол-во | Цена за ед. | Итого |
|---|---|---|
| 1 | $0.6307 | $0,63 |
| 10 | $0.6307 | $6,31 |
| 100 | $0.6307 | $63,07 |
| 500 | $0.6307 | $315,35 |
| 1.000 | $0.6307 | $630,70 |
SP485CN-L Обзор
An RS-485 transceiver is an interface IC that converts logic-level transmit and receive signals into differential bus signals. The SP485CN-L supports both RS-422 and RS-485 protocols, making it suitable for industrial communication, building controls, instrumentation, and embedded systems that require robust differential signaling. Its half-duplex arrangement shares one pair of bus conductors for transmission and reception, so software or hardware must control the direction between nodes.
Key verified characteristics include one transmitter and one receiver, RS-422/RS-485 operation, a 5 Mbps maximum signaling rate, and a 4.75 V to 5.25 V supply range. The SOIC-8 package is compatible with standard surface-mount assembly, and distributor listings identify the device as an 8-SOIC interface transceiver. Exact driver output current, receiver thresholds, propagation delay, and quiescent current are not supplied in the verified data and must be checked against the manufacturer datasheet before final design release.
The SP485CN-L is suited to high-speed half-duplex links where reduced bus wiring and low power are useful. In factory equipment, it can connect a controller to remote sensors or actuators; in building automation, it can carry control commands between distributed nodes; and in test systems, it can support instrumentation connected through RS-485. The 5 Mbps capability is useful for short, controlled links, while cable length, termination, biasing, topology, and protective devices remain important system-level constraints.
For PCB implementation, preserve the device pin assignments and keep the bus-side differential pair routed as a controlled pair. Termination resistors, bias resistors, common-mode protection, ground strategy, and isolation should be selected from the actual cable, topology, and fault-environment requirements. Do not assume that the package alone guarantees robust communication.
This page combines verified distributor and manufacturer references, drop-in replacement context, application guidance, and practical design notes. It also distinguishes the SP485CN-L from packaging variants and identifies when a candidate requires engineering validation rather than claiming unsupported electrical equivalence.
Аналоги без доработки для SP485CN-L — тот же корпус, pin-to-pin совместимость. Компоненты в других корпусах, требующие переработки PCB, исключены.
Варианты в этой серии
Модели той же серии, совместимые без доработки с SP485CN-L (тот же форм-фактор и посадочное место) — отличается по Package, Product Type, Mounting Type, Driver Count, Receiver Count.
Инструмент быстрого сравнения — выберите альтернативные компоненты для сравнения бок о бок:
MAX485CSA-T
✅ Прямая замена📋 Справочный аналог (нет в каталоге)
MAX485CSA+
✅ Прямая замена📋 Справочный аналог (нет в каталоге)
SN75176BD
✅ Прямая замена✓ В наличии
$0.1501 / шт.
Открыть даташит →ST485ERBD
✅ Прямая замена📋 Справочный аналог (нет в каталоге)
SP485ECN-L
✅ Прямая замена📋 Справочный аналог (нет в каталоге)
SP485CN-L Характеристики
| Transceiver Type | Single transmitter/single receiver half-duplex transceiver |
| Supported Protocols | RS-422 and RS-485 |
| Maximum Data Rate | 5 Mbps |
| Supply Voltage Range | 4.75 V to 5.25 V |
| Logic and Bus Function | Bidifferential half-duplex serial interface |
| Architecture | BiCMOS |
| Power Class | Low-power operation |
| Driver Count | 1 |
| Receiver Count | 1 |
| Корпус | 8-pin SOIC |
| Тип монтажа | Surface Mount |
| Temperature Range | 0 C to 70 C |
| Bus Topology | Half-duplex differential bus |
| Signaling | Differential RS-422/RS-485 |
| AEC-Q100 Qualification | not_applicable |
Руководство по цоколевке SP485CN-L в корпусе 8-pin soic
Цоколевка для SP485CN-L (корпус 8-pin soic). Нумерация выводов, функции и схемы подключения определены в техническом описании производителя. Обратитесь к нему для точного посадочного места и рекомендаций по пайке.
Нет подробных данных о распиновке для SP485CN-L.
Обратитесь к даташиту для полной конфигурации выводов.
Типичное применение
SP485CN-L подходит для 6 применениеs: Industrial Automation Bus, Building Automation Networks, Remote Sensor Networks, Process and Factory Control, Instrumentation and Test Systems, Data Acquisition Gateways.
Industrial Automation Bus
The SP485CN-L fits a half-duplex controller-to-field-device link when the design uses one differential pair and a direction-control signal. Its verified RS-422/RS-485 capability and 5 Mbps family rating provide a useful starting point for industrial automation equipment, although actual cable length and node count determine whether the target rate is achievable. Termination, fail-safe biasing, grounding, and surge protection must be designed around the field wiring rather than added only after installation. The 0 C to 70 C verified temperature range should also be checked against the enclosure and process environment.
Рекомендуется
Building Automation Networks
Use the SP485CN-L as a low-power half-duplex interface in building-control equipment that exchanges commands and status over an RS-485 bus. The 4.75 V to 5.25 V supply range simplifies integration with conventional 5 V control electronics, while the single-driver/single-receiver arrangement suits shared bus wiring. The practical benefit is fewer dedicated communication lines than a point-to-point serial interface, but installers still need consistent baud rate, addressing, termination, and grounding. Environmental transients from long building cables may require external protection and isolation.
Рекомендуется
Remote Sensor Networks
The SP485CN-L can connect a controller to remote sensors over a short or medium-length RS-485 segment when half-duplex communication is acceptable. Its verified 5 Mbps capability is useful for sensor backhaul traffic and diagnostic bursts, although lower baud rates may be necessary for long cables or noisy installations. The interface does not replace sensor excitation, signal conditioning, or isolation; those functions must be placed according to the sensor’s electrical requirements. Firmware should manage bus direction and avoid transmitting while multiple nodes are active.
Рекомендуется
Process and Factory Control
In factory control equipment, the SP485CN-L provides a compact differential serial interface between a controller and remote actuators or instrumentation. The BiCMOS low-power architecture is attractive when multiple interface channels share a constrained power budget, and the half-duplex topology reduces wiring compared with separate transmit and receive buses. Designers should still calculate cable loss and common-mode margin, specify 120-ohm termination only where appropriate, and add protection for motor, relay, or industrial switching transients. The verified 0 C to 70 C range limits unrestricted use in harsh environments.
Рекомендуется
Instrumentation and Test Systems
SP485CN-L is suitable for instrument and test-system interfaces that need a reliable, low-power half-duplex link to distributed measurement modules. The verified 5 Mbps family rating can support fast command or data bursts, while the 8-SOIC package supports compact surface-mount assemblies. A successful design must separate sensitive measurement grounds where appropriate, define a common bus reference, and verify that termination and biasing preserve valid receiver levels over the intended cable and node configuration. Protection should be selected based on the laboratory environment and cable routing.
Рекомендуется
Data Acquisition Gateways
The SP485CN-L can act as the field-side interface in a gateway that converts between embedded control electronics and an RS-485 field bus. Its one-driver/one-receiver arrangement is appropriate for a node that participates in a shared half-duplex network, and the low-power architecture supports distributed equipment. The gateway should control transmit direction with deterministic firmware timing, handle bus contention defensively, and expose diagnostics for communication faults. Exact receiver thresholds, propagation delay, and fail-safe behavior must be confirmed from the production datasheet before setting protocol timing limits.
Рекомендуется
Сводка рекомендуемых товаров
Справочные инженерные данные для SP485CN-L — сравнение, рекомендации по проектированию и информация о соответствии.
Руководство по выбору
Сравнение с аналогами
| Параметр | Этот товар | MAX485CSA-T | MAX485CSA+ | SN75176BD | ST485ERBD | SP485ECN-L |
|---|---|---|---|---|---|---|
| Brand | MaxLinear | Maxim Integrated | Maxim Integrated | Texas Instruments | STMicroelectronics | MaxLinear |
| Package | 8-pin SOIC | SOIC-8 | SOIC-8 | SOIC-8 | SOIC-8 | PDSO-8 |
Ключевые отличия
- Verified MaxLinear SP485 family support (против MAX485CSA-T)
- 5 Mbps family capability (против SN75176BD)
- Low-power BiCMOS positioning (против MAX485CSA+)
Заметки по проектированию
Route the two RS-485 bus conductors as a tightly coupled differential pair and keep the transceiver-side ground reference close to the interface. Place any termination and fail-safe bias components where they can be reached by short, defined traces. Because the verified data does not include the exact pinout or recommended resistor values, use the manufacturer datasheet for placement and values instead of copying a generic RS-485 layout.
Do not treat the 5 Mbps family rating as a guarantee for every cable length or topology. Confirm baud rate against cable length, node count, termination, biasing, and environmental noise. Also verify direction-control timing because the SP485CN-L is half-duplex. The verified 0 C to 70 C range and absent detailed transient specifications make it especially important to check the actual operating environment before release.
Use a controlled ground and cable strategy to reduce common-mode noise and radiated emissions. Keep external protection devices close to the connector so surge energy is diverted before reaching the transceiver. Termination should be enabled only according to the selected bus topology; incorrect termination can reduce signal quality or increase load. The supplied data does not establish a specific slew-rate value, so do not claim a specific EMI performance without the manufacturer test data.
Информация о соответствии
The supplied verified data does not provide RoHS, REACH, lead-free, halogen-free, or conflict-minerals declarations. AEC-Q100 is recorded as not_applicable because this is an interface transceiver rather than an automotive-qualified device in the supplied data.