V300B48C150BG - 150W 48V Isolated DC-DC Converter Module | Vicor
Артикул: V300B48C150BG ✓ Активен| Кол-во | Цена за ед. | Итого |
|---|---|---|
| 1 | $285 | $285,00 |
| 10 | $270.5 | $2.705,00 |
| 100 | $245.75 | $24.575,00 |
| 500 | $220 | $110.000,00 |
| 1.000 | $198.5 | $198.500,00 |
V300B48C150BG Обзор
An isolated DC-DC converter module is a packaged power supply subsystem that combines an isolation transformer, control circuitry, and output rectification in a single chassis-mountable brick or module format. Isolated modules sit hierarchically below the broader class of board-mount DC-DC converters and above discrete switch-mode power supply designs; they are essential when system grounds must remain separate, when safety regulations demand reinforced isolation, or when a single high-voltage bus must be tapped to produce intermediate rails. Vicor Maxi-series parts in particular target high-density, high-efficiency (>90%) conversion with Vicor's proprietary zero-current-switching (ZCS) and zero-voltage-switching (ZVS) topologies.
Key features of the V300B48C150BG include ±0.4% set-point accuracy from no-load to full-load, input surge withstand of 400 V for 100 ms, programmable output voltage trim from approximately 10% to 110% of nominal, and Vicor's standard 9-DIP through-hole module form factor. Typical efficiency reaches approximately 88-90% at nominal line and full load, which substantially reduces thermal management overhead compared with discrete solutions in the same power range. The integrated output over-voltage, over-current, and over-temperature protections are internal and self-recovering.
Technically, the converter relies on a forward-topology primary stage feeding a high-frequency isolation transformer, with synchronous rectification on the secondary producing the 48 V low-impedance output. Because the module is a complete brick, designers can treat it as a black-box 48 V power source with predictable line/load regulation and no external compensation network beyond the input/output bulk capacitors. The unit operates over a typical -20 °C to +100 °C baseplate temperature range with adequate heatsinking.
Typical applications include industrial automation PLCs, 48 V telecom and PoE power distribution hubs, railway and traction auxiliary converters, defense and avionics power conditioning, and renewable-energy battery voltage step-down to 48 V intermediate rails. In each case the wide 375 Vdc input envelope accepts rectified 230 Vac or 277 Vac sources directly, eliminating a front-end PFC stage in many designs.
When integrating this module, observe Vicor's guidance on input fuse selection (a fast-acting high-voltage fuse is required for safety), output capacitor ESR limits, and baseplate grounding for EMI suppression. Avoid wiring input and output returns to a common chassis node unless the application explicitly tolerates ground-loop noise, since the module provides reinforced isolation in part design.
This page synthesizes distributor pricing, drop-in Vicor-family alternatives, and practical integration notes that complement rather than duplicate the manufacturer datasheet.
Аналоги без доработки для V300B48C150BG — тот же корпус, pin-to-pin совместимость. Компоненты в других корпусах, требующие переработки PCB, исключены.
Инструмент быстрого сравнения — выберите альтернативные компоненты для сравнения бок о бок:
V300B48C150BL
✅ Прямая замена📋 Справочный аналог (нет в каталоге)
V300B48C150BN
✅ Прямая замена📋 Справочный аналог (нет в каталоге)
V300B48M150BG
✅ Прямая замена ⚠️ Характеристики не проверены📋 Справочный аналог (нет в каталоге)
V300C48C150BG
✅ Прямая замена📋 Справочный аналог (нет в каталоге)
V300B48C150BG Максимальные параметры и электрические характеристики
| Топология | Isolated DC-DC Converter Module |
| Количество выходов | 1 |
| Input Voltage (Min) | 180 V |
| Input Voltage (Max) | 375 V |
| Input Surge Withstand | 400 V for 100 ms |
| Output Voltage (Nominal) | 48 V |
| Output Voltage (Trim Range) | Approximately 10% to 110% of nominal |
| Выходной ток (макс.) | 3.13 A |
| Output Power (Max) | 150 W |
| Line/Load Regulation | ±0.4% (no load to full load) |
| Efficiency (Typical) | Approximately 88-90% at nominal line and full load |
| Package / Mounting Type | 9-DIP Module, Through Hole |
| Protections | Over-Voltage, Over-Current, Over-Temperature (internal, self-recovering) |
Конфигурация выводов V300B48C150BG
| Контакт 1 | +IN — Positive input voltage (180-375 Vdc) |
| Контакт 2 | +IN — Positive input voltage (180-375 Vdc), parallel pin for high current |
| Контакт 3 | -IN — Negative input voltage (input return) |
| Контакт 4 | -IN — Negative input voltage (input return), parallel pin |
| Контакт 5 | ON/OFF — Module enable (refer to Vicor datasheet for active polarity) |
| Контакт 6 | TRIM — Output voltage trim (10% to 110% of nominal) |
| Контакт 7 | +OUT — Positive output (48 V nominal) |
| Контакт 8 | -OUT — Negative output (output return) |
| Контакт 9 | BASEPLATE — Chassis/baseplate ground, thermal mounting surface |
Типичное применение
V300B48C150BG подходит для 7 применениеs: Industrial PLC and Distributed Power Backplane, Telecom 48 V Power Distribution Hub, Railway and Traction Auxiliary Power, Defense and Avionics Power Conditioning, Renewable-Energy Battery Step-Down to 48 V Bus, Medical Imaging and Diagnostic Equipment, Datacenter 48 V Distribution Architecture.
Industrial PLC and Distributed Power Backplane
Why V300B48C150BG fits: The V300B48C150BG accepts 180-375 Vdc directly from rectified industrial mains, eliminating a front-end AC/DC stage for PLC backplanes. Its 150 W continuous output and 48 V 3.13 A capability feed downstream POL converters that power logic, analog, and motion sub-systems on a standard 24 V or 48 V industrial bus. How it is used and performance: Mounted on the DIN-rail or chassis backplane with a small high-voltage fuse on the +IN line; supplies 48 V to downstream brick or POL converters at typical efficiency 88-90% with ±0.4% regulation from no-load to full-load, which keeps PLC analog rails stable for sensor signal acquisition loops.
Рекомендуется
Telecom 48 V Power Distribution Hub
Why V300B48C150BG fits: Telecom central offices and remote radio heads run on standardized -48 V or +48 V distribution buses; the V300B48C150BG's 48 V output at 3.13 A draws cleanly from a 300 V rectified telecom front-end and re-presents the rail at telecom-grade isolation. Reinforced isolation between input and output is essential for the floating-bus architectures that PoE and small-cell base stations require. How it is used and performance: Connected between the high-voltage intermediate bus and the 48 V distribution frame, it sustains ±0.4% regulation across load transients, supporting switched-mode baseband and RF amplifier rails without adding common-mode noise.
Рекомендуется
Railway and Traction Auxiliary Power
Why V300B48C150BG fits: Rolling-stock auxiliary converters operate from 600 Vdc or 750 Vdc traction buses; the V300B48C150BG's 375 Vdc maximum input cannot accept these voltages directly but pairs naturally with a Vicor pre-stage or with battery/catenary-fed 300 V intermediate rails in light-rail and metro subsystems that step down to 48 V for passenger-information displays, door controls, and on-board communications. How it is used and performance: Delivered inside a fan-cooled tray or heatsink assembly, it provides the vibration-resistant, isolated 48 V supply demanded by EN 50155 railway standards when used within its rated thermal envelope.
Рекомендуется
Defense and Avionics Power Conditioning
Why V300B48C150BG fits: Military and avionics platforms frequently derive 270 Vdc or 300 Vdc intermediate buses from generators or rectified AC; the V300B48C150BG accepts 180-375 Vdc input and produces an isolated 48 V 150 W supply for radar processing, flight-control electronics, and electronic-countermeasure subsystems. Reinforced isolation and integrated OVP/OCP/OTP reduce secondary fault monitoring overhead in safety-critical systems. How it is used and performance: Qualified vicariously through Vicor Maxi-series heritage tests, the module is bolted to a chassis spreader plate that doubles as heatsink and EMI ground; it sustains regulated 48 V across MIL-STD-704 transient profiles when sized within rated headroom.
Рекомендуется
Renewable-Energy Battery Step-Down to 48 V Bus
Why V300B48C150BG fits: Solar and energy-storage inverters often produce 300-400 Vdc intermediate rails; the V300B48C150BG taps this directly to produce an isolated 48 V 150 W supply that feeds battery management boards, monitoring gateways, and auxiliary sub-systems without an extra isolation transformer. How it is used and performance: Mounted in the inverter cabinet with input fusing and pre-charge, it holds ±0.4% regulation across the generator's wide DC operating window, with surge withstand of 400 V for 100 ms to absorb inductive transients from the renewable source.
Рекомендуется
Medical Imaging and Diagnostic Equipment
Why V300B48C150BG fits: Medical imaging and diagnostic equipment demand reliable isolated power with strict leakage and patient-safety considerations; the V300B48C150BG's reinforced isolation and integrated protections suit ancillary subsystems such as patient-monitoring displays and imaging workstation power rails fed from a 300 Vdc medical-grade intermediate bus. How it is used and performance: Connected inside the medical chassis with documented creepage/clearance paths, it provides 88-90% efficient 48 V that downstream isolated DC-DC converters further transform to logic and analog rails; this architecture satisfies IEC 60601-1 isolation principles when cascaded appropriately within a 2 x MOPP design.
Рекомендуется
Datacenter 48 V Distribution Architecture
Why V300B48C150BG fits: Next-generation hyperscale datacenters are migrating to 48 V server racks to reduce distribution losses; the V300B48C150BG's 48 V 150 W output complements intermediate-bus converters for GPU blade clusters fed from 300 Vdc battery-backed distribution. Reinforced isolation meets the safety-barrier requirements of high-density rack deployments. How it is used and performance: Used as a high-side isolated brick feeding point-of-load regulators, it provides ±0.4% regulation that keeps GPU voltage rails within tolerance even under transient compute bursts, optimizing rack PUE compared with legacy 12 V architectures.
Рекомендуется
Сводка рекомендуемых товаров
Справочные инженерные данные для V300B48C150BG — сравнение, рекомендации по проектированию и информация о соответствии.
Руководство по выбору
Сравнение с аналогами
| Параметр | Этот товар | V300B48C150BL | V300B48C150BN | V300B48M150BG | V300C48C150BG |
|---|---|---|---|---|---|
| Brand | Vicor | Vicor | Vicor | Vicor | Vicor |
| Package | 9-DIP Module | 9-DIP Module (same) | 9-DIP Module (same) | 9-DIP Module (same) | 9-DIP Module (same) |
| Input Voltage Range | 180 V to 375 V | 180 V to 375 V | 180 V to 375 V | 180 V to 375 V | 180 V to 375 V |
| Output Voltage | 48 V | 48 V | 48 V | 48 V | 48 V |
| Output Power | 150 W | 150 W | 150 W | 150 W | 150 W |
| Regulation | ±0.4% | ±0.4% | ±0.4% | ±0.4% | ±0.4% |
| Mounting | Through Hole | Through Hole | Through Hole | Through Hole | Through Hole |
| Special Option | Standard industrial grade (BG) | Rev. L factory option | Rev. N factory option | Military/extended grade (M) | C-grade factory option |
Ключевые отличия
- Wide 180-375 Vdc input envelope (против Discrete forward converter at 150 W)
- Integrated reinforced isolation (против Discrete transformer-based design)
- Vicor Maxi-series ecosystem (против Generic third-party DC-DC module)
- Programmable output trim 10-110% (против Fixed-output DC-DC brick)
Заметки по проектированию
Recommended: Install a fast-acting high-voltage fuse on the +IN line rated for the DC input voltage with an interrupt rating above the available fault current. Estimated: with a 375 Vdc bus and 150 W load, input current is approximately 0.44 A; size the fuse so it clears before internal MOSFET damage occurs. Vicor's Maxi-series datasheet recommends a specific fuse family because the brick's internal protection assumes an external clearing device. Pair the fuse with an inrush-limiting thermistor or active pre-charge to keep input-side stress within the module's 400 V 100 ms surge rating.
Estimated: at full 150 W load and approximately 88% efficiency, the module dissipates roughly 20 W internally as heat. With the baseplate bolted to an aluminum spreader plate, verify junction and baseplate temperatures stay inside the published derating curve (typical baseplate rating -20 °C to +100 °C). For continuous full-load operation, mount the baseplate to a chassis spreader with thermal interface material and design airflow adequate to keep the baseplate below 90 °C at worst-case ambient; otherwise the internal OTP will limit usable output power.
Recommended: Keep input and output loops physically separated and minimize loop area on the PCB to reduce common-mode and differential-mode EMI. The 9-DIP through-hole leads are positioned for low-inductance bussing; route +IN and -IN as a tight differential pair from the source connector, and likewise +OUT/-OUT from the output capacitor bank to the load. Connect the baseplate ground to chassis with a low-impedance bond (star washer or conductive gasket) to provide both thermal contact and a quiet EMI reference. Maintain the creepage and clearance distances stated by Vicor in the datasheet since this product works at hazardous voltage levels.
Critical: do not exceed 400 V on the input under any condition, including during adjacent power supply turn-on or capacitor inrush. Avoid connecting input and output returns to the same chassis node unless isolation is intentionally defeated; this product is reinforced-isolated. Do not assume pin 5 (ON/OFF) polarity is active-high without checking your specific Maxi-series datasheet revision - some Vicor generations are active-low. Finally, do not operate the module without the recommended minimum output capacitance stated in the datasheet, or output ripple and stability will degrade.
Информация о соответствии
Detailed RoHS, REACH, and lead-free status for the V300B48C150BG are not present in the verified web data; designers should request the latest material declaration from Vicor. AEC-Q100 is not applicable for this through-hole DC-DC converter module since it is not an automotive-grade IC.