BCM6123TD1E5126T00 vs BCM6123TD1E5126T01 Ikinahambing
Detalyadong pagkakahiwalay na pagkakahambing ng BCM6123TD1E5126T00 sa pamamagitan ng Vicor at BCM6123TD1E5126T01 sa pamamagitan ng Vicor. Ikinahambing ang mga pangunahing paglalarawan, mga tama ng elektriko, paakay, kalagayan ng buhay, presyo, at pagkakaroon upang makita ang pinakamahusay na komponente para sa iyong mga kinakailangang pang disenyo.
Vicor
BCM6123TD1E5126T00 - 380V/47.5V 25.7A Isolated BCM Bus Converter | Vicor
BCM6123TD1E5126T00 ✓ NakahandaPagsanggunian na paghahambing
| Parametro | BCM6123TD1E5126T00 | BCM6123TD1E5126T01 |
|---|---|---|
| Brand | Vicor | Vicor |
| Kategorya | DC-DC Converters | DC-DC Converters |
| Katayuan ng Lifecycle | Aktibo | Aktibo |
| Topolohiya | Sine Amplitude Converter (SAC), fixed-ratio isolated | Sine Amplitude Converter (SAC), isolated fixed-ratio |
| Hanay ng Voltage ng Input | 260 V to 410 V (380 V nominal) | 260 V to 410 V |
| Output Voltage (Nominal) | 47.5 V (fixed K-factor ≈ 1:8 step-down) | — |
| Continuous Output Current | 25.7 A | 25.7 A |
| Peak Efficiency | 97.9 % | 97.9% |
| Power Density | 1876 W/in³ | 1876 W/in³ |
| Isolation Voltage | 4242 VDC | — |
| Throughput Power (approx.) | ~1220 W | — |
| Packhaging | BCM6123 through-hole ChiP | Through-hole ChiP (BCM6123) |
| Uri ng Pagpapasok | Through Hole | — |
| Control Interface | Analog | — |
| Parallel Operation | Yes, for multi-kW arrays | Supported for multi-kW arrays |
| Protections | OV, OC, UV, short-circuit, thermal shutdown | OV, OC, UV, short circuit, thermal |
| Output Regulation | Unregulated (fixed K factor) | — |
| Tindminan RoHS | [DATA_NEEDED: RoHS status] | [DATA_NEEDED: RoHS status] |
| Temperature na Operasyon | [DATA_NEEDED: operating temperature range] | -40°C to +125°C (see derating curves) |
| Transformation Ratio (K) | — | 1/8 (K=1/8) |
| Nominal Input Voltage | — | 380 V |
| Output Voltage (nominal) | — | 47.5 V |
| Continuous Output Power | — | 1220 W (47.5 V x 25.7 A) |
| Isolation Voltage (Input to Output) | — | 4242 VDC |
| Device Grade | — | T01 (telemetry/control) |
| Cooling Method | — | Forced air or cold-plate recommended for full load |