Analog Devices

AD549KHZ - 1MHz Electrometer Op Amp | Analog Devices

MPN: AD549KHZ ✓ Nakahanda
±5 V to ±18 V Vdss 100 fA Id TO-99 hermetic, 8 pins Package
MOQ: 1 |

AD549KHZ Ulas

Analog Devices AD549KHZ is a precision electrometer operational amplifier with one amplifier channel, 1 MHz gain-bandwidth product, 3 V/µs slew rate, and an 8-pin TO-99 hermetic package. The K-grade device provides a maximum input bias current of 100 fA, a maximum input offset voltage of 0.50 mV, and a maximum offset-voltage drift of 15 µV/°C. It operates from ±5 V to ±18 V.

An electrometer operational amplifier is a specialized low-noise, high-impedance input amplifier optimized for measuring very small currents. Its hierarchy extends from precision operational amplifier to instrumentation amplifier and signal-conditioning IC. Unlike ordinary voltage-feedback amplifiers, the AD549 family uses Analog Devices Topgate JFET technology to obtain extremely low input current, making it suitable for sensors, charge measurement, and precision current-to-voltage conversion.

The AD549KHZ combines its 100 fA maximum input bias current with laser-trimmed offset voltage and offset drift. These characteristics reduce errors when the amplifier is connected to high-impedance transducers, guarding networks, photodiodes, or capacitive sensors. Its 1 MHz gain-bandwidth product supports wider-band signal conditioning than a purely low-frequency electrometer, while the 3 V/µs slew rate preserves useful large-signal response.

Analog Devices describes the AD549 as a monolithic electrometer amplifier whose input current is guaranteed over the common-mode voltage range. The device is available in a hermetic TO-99 package, which supports use in precision laboratory, instrumentation, and industrial measurement systems where connector leakage, contamination, and temperature drift can affect signal integrity.

Typical uses include photodiode transimpedance amplifiers, pH and ion-selective electrode interfaces, low-current power meters, capacitive sensors, precision integrators, and sample-and-hold circuits. The AD549 can also serve as a general-purpose precision amplifier in systems requiring substantially lower input current than conventional bipolar or MOSFET input amplifiers.

When designing around the AD549KHZ, protect sensitive inputs from electrostatic discharge, contamination, and surface leakage. Keep input traces short, use guarding where supported by the circuit, maintain clean connector insulation, and account for offset drift over the full operating-temperature range. These practices are especially important because the input current is exceptionally low and external leakage can become comparable to the amplifier's own current.

This product page combines the manufacturer's device description with application-specific engineering guidance, package information, practical design notes, and a parameter comparison covering the AD549 family and the pin-compatible OPA128KM reference. These details help engineers evaluate the AD549KHZ for precision measurement without overlooking input leakage, temperature drift, or package-level implementation constraints.

Mga alternatibo na pwedeng ilagay na AD549KHZ — parehas na package, pin-to-pin na katugmang. Hindi kasama ang mga bahagi ng iba't-ibang package na nangangailangan ng pagpapaayos ng PCB.

Variante sa Seri na ito

Katulad na modelo sa serye na katugma sa pagpasok AD549KHZ (parehas na form factor at footprint) — pagkakaiba sa Package Type, Slew Rate, Number of Channels, Input Offset Voltage Drift Maximum, Offset Adjustment Method.

Analog Devices
Package Type: TO-99-8 hermetic
Slew Rate: 3 V/us
Number of Channels: 1 channel
Ikabit sa AD549KHZ →
Analog Devices
Package Type: TO-99-8 hermetic package
Slew Rate: 3 V/μs
Number of Channels: 1 channel
Ikabit sa AD549KHZ →

AD549JHZ

✅ Drop-In
Analog Devices
📦 TO-99-8
Electrometer operational amplifier · 1 channel · 250 fA for AD549J grade · 1.00 mV for AD549J grade · 15 μV/°C · 1 MHz · 3 V/μs · ±5 V to ±18 V

Magkontak para sa presyo

Tingnan ang Datasheet →

AD549LHZ

✅ Drop-In
Analog Devices
📦 TO-99-8
Single-circuit electrometer operational amplifier · Topgate JFET · 1 MHz · 1 circuit · Electrometer operational amplifier

Magkontak para sa presyo

Tingnan ang Datasheet →

AD549KH

✅ Drop-In
📦 TO-99-8
Same AD549 K-grade family and 8-pin through-hole package, with the orderable suffix and guaranteed-limit details differing by an amount not stated in the comparison listing.

📋 Alternatibo na Reference (hindi sa katalogo)

AD549JH

✅ Drop-In
Analog Devices
📦 TO-99-8
Electrometer operational amplifier · 1 channel · 0.15 pA · 1 mV · 1 MHz · 3 V/us · Topgate JFET · Laser trimmed

Magkontak para sa presyo

Tingnan ang Datasheet →

OPA128KM

✅ Drop-In
📦 TO-99-8
Pin-compatible 8-pin electrometer amplifier with a different manufacturer and grade-specific electrical limits that are not stated in the available comparison listing.

📋 Alternatibo na Reference (hindi sa katalogo)

AD549KHZ Mga Pinakamataas na Rating at Electrical Characteristics

Amplifier Type Electrometer operational amplifier
Number of Channels 1 amplifier
Topolohiya Monolithic voltage-feedback operational amplifier
Gain-Bandwidth Product 1 MHz
Slew Rate 3 V/µs
Supply Voltage Range ±5 V to ±18 V
Input Bias Current, K Grade Maximum 100 fA
Input Offset Voltage, K Grade Maximum 0.50 mV
Input Offset Voltage Drift Maximum 15 µV/°C
Input Technology Topgate JFET
Offset Adjustment Method Laser trimming
Bias-Current Guarantee Guaranteed over the common-mode voltage range
Package Type TO-99 hermetic, 8 pins
Uri ng Pagpapasok Through-hole

Gabay sa Pin Configuration ng AD549KHZ to-99 hermetic, 8 pins

Pin configuration para sa AD549KHZ (to-99 hermetic, 8 pins package). Ang analog component na ito ay may input, output, at power supply pins. Sumangguni sa datasheet ng manufacturer para sa offset null, compensation, at enable pin configurations. Perpekto para sa signal conditioning at amplifier circuits.

Pinout diagram ng to-99 hermetic, 8 pins package para sa AD549KHZ

Wala ng detalyadong pinout data na magagamit para sa AD549KHZ.

Sumangguni sa datasheet para sa buong pin configuration.

Tipikal na mga Gamit

AD549KHZ ay nararapat para sa 6 aplikasyons: Photodiode Transimpedance Amplification, Precision pH Electrode Interface, Capacitive Sensor Signal Conditioning, Low-Current Power Measurement, Precision Integrator and Sample-and-Hold, Laboratory Instrumentation Signal Conditioning.

📷

Photodiode Transimpedance Amplification

The AD549KHZ suits low-level photodiode measurement because its K-grade maximum input bias current is 100 fA and the input current is guaranteed across the common-mode range. It can be configured as a transimpedance amplifier that converts photocurrent into a measurable voltage. This makes the device relevant to optical power monitors, fluorescence systems, spectrometers, and laboratory photodetectors. The principal trade-off is that a large feedback resistance can reduce bandwidth as photodiode capacitance increases, so the feedback and compensation network must be selected for the actual detector. Guarding, short input traces, clean connectors, and low-leakage PCB materials remain important because board contamination can create currents comparable to the amplifier's specified bias current.

🧪

Precision pH Electrode Interface

The AD549KHZ is appropriate for electrochemical sensors because its 100 fA maximum input bias current limits loading of high-output-impedance pH and ion-selective electrodes. The amplifier can buffer the electrode output into a measurement system without extracting significant signal current. Its 1 MHz gain-bandwidth product is sufficient for signal conditioning, while laser-trimmed offset voltage of 0.50 mV maximum and offset drift of 15 µV/°C maximum help control baseline error. In a complete pH measurement path, the amplifier should be mounted away from wet chemistry, humidity, and conductive contamination because connector and PCB leakage can degrade accuracy. A low-noise reference stage and properly stabilized supply are also needed to preserve the electrode's useful signal.

🧩

Capacitive Sensor Signal Conditioning

The AD549KHZ can condition capacitive sensors where the sensing element produces very small currents and requires a high-impedance input. Its ultralow 100 fA maximum input bias current minimizes the error introduced by loading the sensor, while the 1 MHz gain-bandwidth product provides more bandwidth than is normally required for static capacitance measurements. Typical uses include touch plates, humidity elements, pressure diaphragms, and level sensors. The design must still account for stray capacitance, cable length, insulation resistance, and dielectric absorption. For dynamic measurements, compensation must balance amplifier stability against the sensor's effective capacitance. Keeping the sensitive node short and using guarded layouts helps prevent leakage from turning a high-impedance sensor into a noise source.

⚡

Low-Current Power Measurement

The AD549KHZ is useful in low-current power measurement systems where the monitored current is comparable to the amplifier's input bias current. Its 100 fA maximum input bias current and laser-trimmed 0.50 mV maximum input offset voltage support accurate signal conditioning around sensitive current-detection elements. The device fits laboratory power meters, electrochemical monitors, leakage testers, and battery analysis equipment. The main design concern is that input leakage, relay contamination, switch resistance, and thermal gradients may dominate the measured current. Use clean high-insulation-resistance materials and consider offset correction and temperature compensation across the operating range. The ±5 V to ±18 V supply range permits conventional laboratory and industrial rails, but the reference and shunt design must account for leakage and voltage drift.

🔧

Precision Integrator and Sample-and-Hold

The Analog Devices AD549 family is specifically identified for precision integration and low-droop sample-and-hold operation, making the AD549KHZ appropriate for measurement systems that accumulate small currents or preserve charge. The K-grade input offset limits of 0.50 mV maximum and 15 µV/°C maximum drift help bound integration error, while the 100 fA maximum input bias current reduces unwanted charge injection into the summing node. Practical implementations should use low-leakage feedback and hold capacitors, clean switches, and careful board protection. The 1 MHz gain-bandwidth product and 3 V/µs slew rate support useful settling performance, although capacitor dielectric absorption and switch leakage can dominate long acquisition intervals. Validate the complete circuit against the required integration time and droop specification.

🖥️

Laboratory Instrumentation Signal Conditioning

The AD549KHZ supports precision laboratory instrumentation because it combines a 1 MHz gain-bandwidth product with very low input current in a hermetic 8-pin TO-99 package. It can be used for buffer, gain, current-to-voltage, and feedback stages in source-measurement equipment, potentiostats, dielectric analyzers, and laboratory sensor interfaces. The hermetic package helps support stable operation in precision systems, but enclosure cleanliness and connector insulation remain critical. The device's maximum offset voltage of 0.50 mV and drift of 15 µV/°C must be included in calibration and error budgets. It is particularly appropriate when the source impedance is high enough that a conventional operational amplifier's input current would materially alter the measurement.

Buod ng mga Inirekomendang Produkto

AD549LHZ Analog Devices Ginagamit sa: Photodiode Transimpedance Amplification, Capacitive Sensor Signal Conditioning, Precision Integrator and Sample-and-Hold, Laboratory Instrumentation Signal Conditioning OPA128KM Pin-compatible precision electrometer amplifier Ginagamit sa: Photodiode Transimpedance Amplification, Precision pH Electrode Interface, Capacitive Sensor Signal Conditioning, Precision Integrator and Sample-and-Hold AD549JHZ Analog Devices Ginagamit sa: Precision pH Electrode Interface, Low-Current Power Measurement, Laboratory Instrumentation Signal Conditioning AD549KH Same-family K-grade ordering option Ginagamit sa: Low-Current Power Measurement
What is the AD549KHZ and what are its key specifications?
The AD549KHZ is a single-channel electrometer operational amplifier with a 1 MHz gain-bandwidth product, 3 V/µs slew rate, and an 8-pin hermetic TO-99 package. According to the Analog Devices AD549 datasheet, the K-grade device has a maximum input bias current of 100 fA, maximum input offset voltage of 0.50 mV, and maximum offset drift of 15 µV/°C. It operates from ±5 V to ±18 V.
What is the input bias current of AD549KHZ?
The AD549KHZ has a maximum input bias current of 100 fA at specified operating conditions. According to the Analog Devices AD549 datasheet, this very low current is achieved with Topgate JFET technology and is guaranteed over the common-mode voltage range. The specification makes the device suitable for high-impedance transducers, photodiodes, capacitive sensors, and precision current-measurement circuits.
Where can I download the AD549KHZ datasheet PDF?
The official AD549KHZ datasheet PDF is available from the Analog Devices product page at https://www.analog.com/media/en/technical-documentation/data-sheets/AD549.pdf. The document covers the AD549 family's features, electrical characteristics, pin descriptions, typical performance curves, and application information. Use the Analog Devices document for production design decisions and the AD549KHZ grade limits.
Where can I find the AD549KHZ pinout?
The AD549KHZ pinout is documented in the pin-description section of the official Analog Devices AD549 datasheet. The device is an 8-pin TO-99 hermetic package with through-hole mounting. Use that pin-description table when assigning supply, output, offset-adjustment, input, and guard connections; do not infer the pin arrangement from a generic TO-99 drawing.
What is the AD549KHZ used for?
The AD549KHZ is used for precision measurement of very small currents and voltages. According to the Analog Devices product description, it can serve as a precision integrator, low-droop sample-and-hold circuit, or general electrometer input amplifier. Its 100 fA maximum input bias current and hermetic 8-pin TO-99 package suit pH electrodes, photodiodes, capacitive sensors, and laboratory instrumentation.
Is AD549KHZ suitable for photodiode and capacitive sensor measurements?
Yes, the AD549KHZ is suitable for photodiode and capacitive sensor front ends because its K-grade input bias current is specified up to 100 fA. According to the Analog Devices AD549 datasheet, the input current is guaranteed over the common-mode voltage range. In a transimpedance amplifier, however, feedback resistance, diode capacitance, board leakage, and guard-ring design determine the achievable bandwidth and sensitivity.
AD549KHZ vs OPA128KM - which is better for an electrometer circuit?
The AD549KHZ is the better-documented choice for this exact-orderable variant, with a K-grade maximum input bias current of 100 fA, maximum input offset voltage of 0.50 mV, and maximum offset drift of 15 µV/°C. The OPA128KM is identified in comparison listings as an 8-pin through-hole electrometer amplifier, but its parameter set is not stated here. Compare the complete manufacturer tables before exchanging them.
AD549KHZ vs AD549LHZ - what changes between the precision grades?
The AD549KHZ and AD549LHZ differ primarily in their guaranteed precision limits. A comparison source reports 4.2 pA input bias current for AD549KHZ versus 2.8 pA for AD549LHZ, while the AD549 datasheet identifies the K grade as having a 100 fA maximum input bias current and 0.50 mV maximum offset voltage. Select by the guaranteed limits relevant to the measurement.
AD549KHZ vs AD549JHZ - when should I choose the K grade?
Choose the AD549KHZ when a tighter offset specification matters more than the lower-grade part's relaxed limits. A comparison source gives AD549JHZ an input bias current of 11 pA and input offset voltage of 500 µV, compared with 4.2 pA and 150 µV for AD549KHZ under those comparison conditions. The official grade-specific limits should govern a production decision.
When should I choose AD549KHZ over another electrometer amplifier?
Choose the AD549KHZ when the design needs a documented 8-pin TO-99 electrometer amplifier, a maximum input bias current of 100 fA, maximum input offset voltage of 0.50 mV, and operation from ±5 V to ±18 V. It is particularly appropriate for guarded high-impedance transducers and precision current measurement. Choose a different grade or device when leakage, offset, bandwidth, or package requirements differ.
What can replace the AD549KHZ?
The AD549JHZ and AD549LHZ are same-family drop-in candidates in the TO-99-8 format, although their precision grades differ. The OPA128KM also appears in cross-reference results as an 8-pin through-hole electrometer amplifier. Confirm the complete electrical limits, offset-adjustment behavior, pin assignment, and common-mode range in the manufacturer's datasheet before approving any substitution.
What is the best drop-in replacement for AD549KHZ?
The AD549KHZ can be replaced by the AD549LHZ when its tighter bias-current grade is not required, but the AD549LHZ has different guaranteed limits. The AD549JHZ is another same-package family option with relaxed offset specifications. Neither is an exact functional clone across every guaranteed limit, so the closest drop-in choice depends on which measured and specified error terms your circuit cannot tolerate.
Where can I buy AD549KHZ online and what is its price?
The AD549KHZ can be requested through the Request a Quote form on this page for current commercial availability and a unit quotation. Because the device is a precision, hermetically packaged electrometer amplifier, its availability and lead time can depend on manufacturer inventory and order quantity. Use the quote form rather than a historical catalog figure for current purchasing decisions.
Is AD549KHZ in stock and what is the lead time?
Current stock and lead time for the AD549KHZ should be confirmed through the Request a Quote form on this page. The manufacturer's AD549 family is offered in a hermetic TO-99 package, and orderable quantities can depend on production inventory and packaging requirements. State the required quantity, date code, and inspection requirements with the request to obtain an actionable schedule.
What are the key AD549KHZ design considerations?
The main AD549KHZ design consideration is that input leakage can approach the device's 100 fA maximum bias current. According to the Analog Devices AD549 datasheet, bias current is guaranteed over the common-mode voltage range. Use clean connectors, guarded input routing, suitable insulation, and stable reference nodes; also include offset and drift over the intended temperature range rather than relying only on the 25 °C typical values.

Impormasyon ng Talumpati sa Engineering for AD549KHZ — ikabit, gabay sa disenyo, at impormasyon ng pagsunod sa kautusan.

Paunawang Hanapin

Choose the AD549KHZ when the design requires a high-impedance electrometer input with a maximum bias current of 100 fA, maximum input offset voltage of 0.50 mV, and a hermetic TO-99-8 package. It is a strong fit for photodiodes, electrochemical sensors, capacitive sensors, integrators, and laboratory instruments where source leakage is a primary error source. The AD549JHZ or AD549JH can be considered when relaxed J-grade offset limits are acceptable. The AD549LHZ is relevant when its specific grade limits provide a better match to the measurement requirement. OPA128KM is a cross-manufacturer, pin-compatible option to evaluate when its complete electrical characteristics satisfy the design. In every case, verify supply range, input bias current, offset drift, common-mode behavior, stability, and the exact pin assignment before approving a replacement.

Ikabit sa Mga Alternatibo

Parametro Ito ang Producto AD549JHZ AD549LHZ AD549KH AD549JH OPA128KM
Brand Analog Devices Analog Devices Analog Devices Analog Devices Analog Devices Texas Instruments
Package TO-99-8 hermetic TO-99-8 TO-99-8 TO-99-8 TO-99-8 TO-99-8
Mounting Type Through-hole Through-hole Through-hole Through-hole Through-hole Through-hole
Number of Pins 8 pins 8 pins 8 pins 8 pins 8 pins 8 pins
Amplifier Type Electrometer operational amplifier Electrometer operational amplifier Electrometer operational amplifier Electrometer operational amplifier Electrometer operational amplifier Electrometer operational amplifier

Pangunahing mga Pagkakaiba

  • Tighter K-grade input offset limit than the J-grade family option (kumpara saAD549JHZ)
  • Documented offset and bias-current grading for precision error budgets (kumpara saAD549LHZ)
  • Pin-compatible precision electrometer option from a different manufacturer (kumpara saOPA128KM)

Talaan ng Disenyo

Keep the sensitive input node physically short and isolate it from high-impedance leakage paths. Use clean connector insulation, low-contamination PCB materials, and guard structures where the manufacturer's circuit recommendations permit them. Because the AD549KHZ has a 100 fA maximum K-grade input bias current, leakage caused by moisture, flux residue, or contaminated connectors can become a significant measurement error. Avoid routing guard and input traces in parallel where capacitive coupling could affect settling.

Use the hermetic TO-99-8 package in a socketed or carefully handled through-hole layout, and observe standard precautions for electrostatic-sensitive precision devices. Maintain short feedback paths and place the feedback resistor directly across the relevant amplifier pins. For photodiode, capacitive-sensor, and pH-electrode circuits, separate sensitive input routing from digital, switching, and power-conversion nodes. Confirm every connection against the AD549 datasheet pin-description table rather than a generic TO-99 outline.

Do not evaluate offset performance only at room temperature. The AD549KHZ has a maximum offset drift of 15 µV/°C, so long measurement intervals or wide ambient changes can accumulate error even when the 0.50 mV maximum input offset voltage is acceptable. Include drift, bias current, common-mode range, leakage, and reference-node stability in the uncertainty budget. The ±5 V to ±18 V supply requirement must also be met with correctly decoupled bipolar rails.

Impormasyon ng Pagsunod sa Kautusan

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
Walang Lead
Unknown
Walang Halogen
Unknown
Mga Conflict Mineral
Unknown

The manufacturer product page and datasheet identify the AD549 as an Analog Devices precision electrometer operational amplifier. Specific RoHS, REACH, AEC-Q100, lead-free, halogen-free, and conflict-minerals declarations were not identified in the cited product information.

Data napatotohanan sa: 2026-11-25 — impormasyon na pinatunayan at pinapatakbo ng pangkat ng engineering ng XAIPART's component engineering team

Kaugnay na Hanapin

AD549KHZ datasheet AD549KHZ pinout AD549KHZ datasheet pdf Analog Devices AD549KHZ AD549KHZ TO-99-8 AD549KHZ electrometer amplifier AD549KHZ input bias current AD549KHZ photodiode amplifier AD549KHZ vs OPA128KM AD549KHZ vs AD549JHZ AD549KHZ drop-in replacement AD549KHZ price AD549KHZ stock AD549KHZ application circuit AD549KHZ precision measurement amplifier

Mga kaugnay na Mga Komponente at mga Tuntunin

Analog Devices AD549KHZ AD549JHZ AD549LHZ AD549KH AD549JH OPA128KM electrometer operational amplifier precision operational amplifier instrumentation amplifier signal-conditioning IC Topgate JFET input bias current input offset voltage offset-voltage drift common-mode voltage range gain-bandwidth product slew rate TO-99-8 hermetic package through-hole mounting transimpedance amplifier pH electrode capacitive sensor precision integrator
Mabilis na Tanggap na RFQ
Ihanda ang buong detalye — ang aming pangkalakal na koponan ay tutugon sa loob ng 24 oras
Numero ng Parte Mga Tagagawa Pakete QTY Target na Halaga Pinalawak
✓
Quote na inilabas!

Ating tumugon sa iyong email sa loob ng 24 oras

1
RFQ Naisumite
2
Received na ang Kwaliksik
3
Nai-order
4
Pagbabayad
5
Inihanda
6
Naihanda
Tingnan ang Detalye ng RFQ