AD549KHZ - 1MHz Electrometer Op Amp | Analog Devices
MPN: AD549KHZ ✓ Hoạt độngAD549KHZ Tóm tắt
An electrometer operational amplifier is a specialized low-noise, high-impedance input amplifier optimized for measuring very small currents. Its hierarchy extends from precision operational amplifier to instrumentation amplifier and signal-conditioning IC. Unlike ordinary voltage-feedback amplifiers, the AD549 family uses Analog Devices Topgate JFET technology to obtain extremely low input current, making it suitable for sensors, charge measurement, and precision current-to-voltage conversion.
The AD549KHZ combines its 100 fA maximum input bias current with laser-trimmed offset voltage and offset drift. These characteristics reduce errors when the amplifier is connected to high-impedance transducers, guarding networks, photodiodes, or capacitive sensors. Its 1 MHz gain-bandwidth product supports wider-band signal conditioning than a purely low-frequency electrometer, while the 3 V/µs slew rate preserves useful large-signal response.
Analog Devices describes the AD549 as a monolithic electrometer amplifier whose input current is guaranteed over the common-mode voltage range. The device is available in a hermetic TO-99 package, which supports use in precision laboratory, instrumentation, and industrial measurement systems where connector leakage, contamination, and temperature drift can affect signal integrity.
Typical uses include photodiode transimpedance amplifiers, pH and ion-selective electrode interfaces, low-current power meters, capacitive sensors, precision integrators, and sample-and-hold circuits. The AD549 can also serve as a general-purpose precision amplifier in systems requiring substantially lower input current than conventional bipolar or MOSFET input amplifiers.
When designing around the AD549KHZ, protect sensitive inputs from electrostatic discharge, contamination, and surface leakage. Keep input traces short, use guarding where supported by the circuit, maintain clean connector insulation, and account for offset drift over the full operating-temperature range. These practices are especially important because the input current is exceptionally low and external leakage can become comparable to the amplifier's own current.
This product page combines the manufacturer's device description with application-specific engineering guidance, package information, practical design notes, and a parameter comparison covering the AD549 family and the pin-compatible OPA128KM reference. These details help engineers evaluate the AD549KHZ for precision measurement without overlooking input leakage, temperature drift, or package-level implementation constraints.
Bộ thay thế dễ dàng lắp đặt cho AD549KHZ — cùng gói, chân-to-chân tương thích. Các bộ phận yêu cầu hàn PCB bị loại trừ.
Các biến thể trong loạt này
Các mẫu cùng loạt có thể lắp đặt dễ dàng tương thích với AD549KHZ (cùng hình factor và footprint) — khác nhau ở Package Type, Slew Rate, Number of Channels, Input Offset Voltage Drift Maximum, Offset Adjustment Method.
AD549JHZ
✅ Drop-InLiên hệ để biết giá
Xem tài liệu →AD549LHZ
✅ Drop-InLiên hệ để biết giá
Xem tài liệu →AD549KH
✅ Drop-In📋 Tham chiếu thay thế (không có trong danh mục)
AD549JH
✅ Drop-InLiên hệ để biết giá
Xem tài liệu →OPA128KM
✅ Drop-In📋 Tham chiếu thay thế (không có trong danh mục)
AD549KHZ Tỷ lệ tối đa & tính chất điện
| Amplifier Type | Electrometer operational amplifier |
| Number of Channels | 1 amplifier |
| Cấu trúc | Monolithic voltage-feedback operational amplifier |
| Gain-Bandwidth Product | 1 MHz |
| Slew Rate | 3 V/µs |
| Supply Voltage Range | ±5 V to ±18 V |
| Input Bias Current, K Grade Maximum | 100 fA |
| Input Offset Voltage, K Grade Maximum | 0.50 mV |
| Input Offset Voltage Drift Maximum | 15 µV/°C |
| Input Technology | Topgate JFET |
| Offset Adjustment Method | Laser trimming |
| Bias-Current Guarantee | Guaranteed over the common-mode voltage range |
| Package Type | TO-99 hermetic, 8 pins |
| Kiểu lắp đặt | Through-hole |
Hướng dẫn cấu hình chân AD549KHZ to-99 hermetic, 8 pins
Cấu hình chân cho AD549KHZ (to-99 hermetic, 8 pins gói). Thành phần số hiệu này có chân đầu vào, đầu ra và nguồn cung cấp. Tham khảo tài liệu thông số kỹ thuật của nhà sản xuất để biết cấu hình chân bù, bù trừ và chân kích hoạt. Hoàn hảo cho điều kiện tín hiệu và mạch khuếch đại.
Không có dữ liệu chân cụ thể sẵn có cho AD549KHZ.
Tham khảo: tài liệu kỹ thuật cho cấu hình chân đầy đủ.
Ứng dụng tiêu biểu
AD549KHZ phù hợp cho 6 Áp dụngs: Photodiode Transimpedance Amplification, Precision pH Electrode Interface, Capacitive Sensor Signal Conditioning, Low-Current Power Measurement, Precision Integrator and Sample-and-Hold, Laboratory Instrumentation Signal Conditioning.
Photodiode Transimpedance Amplification
The AD549KHZ suits low-level photodiode measurement because its K-grade maximum input bias current is 100 fA and the input current is guaranteed across the common-mode range. It can be configured as a transimpedance amplifier that converts photocurrent into a measurable voltage. This makes the device relevant to optical power monitors, fluorescence systems, spectrometers, and laboratory photodetectors. The principal trade-off is that a large feedback resistance can reduce bandwidth as photodiode capacitance increases, so the feedback and compensation network must be selected for the actual detector. Guarding, short input traces, clean connectors, and low-leakage PCB materials remain important because board contamination can create currents comparable to the amplifier's specified bias current.
Được đề xuất
Precision pH Electrode Interface
The AD549KHZ is appropriate for electrochemical sensors because its 100 fA maximum input bias current limits loading of high-output-impedance pH and ion-selective electrodes. The amplifier can buffer the electrode output into a measurement system without extracting significant signal current. Its 1 MHz gain-bandwidth product is sufficient for signal conditioning, while laser-trimmed offset voltage of 0.50 mV maximum and offset drift of 15 µV/°C maximum help control baseline error. In a complete pH measurement path, the amplifier should be mounted away from wet chemistry, humidity, and conductive contamination because connector and PCB leakage can degrade accuracy. A low-noise reference stage and properly stabilized supply are also needed to preserve the electrode's useful signal.
Được đề xuất
Capacitive Sensor Signal Conditioning
The AD549KHZ can condition capacitive sensors where the sensing element produces very small currents and requires a high-impedance input. Its ultralow 100 fA maximum input bias current minimizes the error introduced by loading the sensor, while the 1 MHz gain-bandwidth product provides more bandwidth than is normally required for static capacitance measurements. Typical uses include touch plates, humidity elements, pressure diaphragms, and level sensors. The design must still account for stray capacitance, cable length, insulation resistance, and dielectric absorption. For dynamic measurements, compensation must balance amplifier stability against the sensor's effective capacitance. Keeping the sensitive node short and using guarded layouts helps prevent leakage from turning a high-impedance sensor into a noise source.
Được đề xuất
Low-Current Power Measurement
The AD549KHZ is useful in low-current power measurement systems where the monitored current is comparable to the amplifier's input bias current. Its 100 fA maximum input bias current and laser-trimmed 0.50 mV maximum input offset voltage support accurate signal conditioning around sensitive current-detection elements. The device fits laboratory power meters, electrochemical monitors, leakage testers, and battery analysis equipment. The main design concern is that input leakage, relay contamination, switch resistance, and thermal gradients may dominate the measured current. Use clean high-insulation-resistance materials and consider offset correction and temperature compensation across the operating range. The ±5 V to ±18 V supply range permits conventional laboratory and industrial rails, but the reference and shunt design must account for leakage and voltage drift.
Được đề xuất
Precision Integrator and Sample-and-Hold
The Analog Devices AD549 family is specifically identified for precision integration and low-droop sample-and-hold operation, making the AD549KHZ appropriate for measurement systems that accumulate small currents or preserve charge. The K-grade input offset limits of 0.50 mV maximum and 15 µV/°C maximum drift help bound integration error, while the 100 fA maximum input bias current reduces unwanted charge injection into the summing node. Practical implementations should use low-leakage feedback and hold capacitors, clean switches, and careful board protection. The 1 MHz gain-bandwidth product and 3 V/µs slew rate support useful settling performance, although capacitor dielectric absorption and switch leakage can dominate long acquisition intervals. Validate the complete circuit against the required integration time and droop specification.
Được đề xuất
Laboratory Instrumentation Signal Conditioning
The AD549KHZ supports precision laboratory instrumentation because it combines a 1 MHz gain-bandwidth product with very low input current in a hermetic 8-pin TO-99 package. It can be used for buffer, gain, current-to-voltage, and feedback stages in source-measurement equipment, potentiostats, dielectric analyzers, and laboratory sensor interfaces. The hermetic package helps support stable operation in precision systems, but enclosure cleanliness and connector insulation remain critical. The device's maximum offset voltage of 0.50 mV and drift of 15 µV/°C must be included in calibration and error budgets. It is particularly appropriate when the source impedance is high enough that a conventional operational amplifier's input current would materially alter the measurement.
Được đề xuất
Tóm tắt các sản phẩm được đề xuất
Dữ liệu tham khảo kỹ thuật cho AD549KHZ — so sánh, hướng dẫn thiết kế và thông tin tuân thủ.
Hướng dẫn chọn lựa
So sánh với các sản phẩm thay thế
| Tham số | Sản phẩm này | AD549JHZ | AD549LHZ | AD549KH | AD549JH | OPA128KM |
|---|---|---|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Texas Instruments |
| Package | TO-99-8 hermetic | TO-99-8 | TO-99-8 | TO-99-8 | TO-99-8 | TO-99-8 |
| Mounting Type | Through-hole | Through-hole | Through-hole | Through-hole | Through-hole | Through-hole |
| Number of Pins | 8 pins | 8 pins | 8 pins | 8 pins | 8 pins | 8 pins |
| Amplifier Type | Electrometer operational amplifier | Electrometer operational amplifier | Electrometer operational amplifier | Electrometer operational amplifier | Electrometer operational amplifier | Electrometer operational amplifier |
Bảo phân biệt quan trọng
- Tighter K-grade input offset limit than the J-grade family option (vsAD549JHZ)
- Documented offset and bias-current grading for precision error budgets (vsAD549LHZ)
- Pin-compatible precision electrometer option from a different manufacturer (vsOPA128KM)
Ghi chú thiết kế
Keep the sensitive input node physically short and isolate it from high-impedance leakage paths. Use clean connector insulation, low-contamination PCB materials, and guard structures where the manufacturer's circuit recommendations permit them. Because the AD549KHZ has a 100 fA maximum K-grade input bias current, leakage caused by moisture, flux residue, or contaminated connectors can become a significant measurement error. Avoid routing guard and input traces in parallel where capacitive coupling could affect settling.
Use the hermetic TO-99-8 package in a socketed or carefully handled through-hole layout, and observe standard precautions for electrostatic-sensitive precision devices. Maintain short feedback paths and place the feedback resistor directly across the relevant amplifier pins. For photodiode, capacitive-sensor, and pH-electrode circuits, separate sensitive input routing from digital, switching, and power-conversion nodes. Confirm every connection against the AD549 datasheet pin-description table rather than a generic TO-99 outline.
Do not evaluate offset performance only at room temperature. The AD549KHZ has a maximum offset drift of 15 µV/°C, so long measurement intervals or wide ambient changes can accumulate error even when the 0.50 mV maximum input offset voltage is acceptable. Include drift, bias current, common-mode range, leakage, and reference-node stability in the uncertainty budget. The ±5 V to ±18 V supply requirement must also be met with correctly decoupled bipolar rails.
Thông tin tuân thủ
The manufacturer product page and datasheet identify the AD549 as an Analog Devices precision electrometer operational amplifier. Specific RoHS, REACH, AEC-Q100, lead-free, halogen-free, and conflict-minerals declarations were not identified in the cited product information.