Maxim Integrated

ICL7126CQH-D - 3.5-Digit LCD ADC | Maxim Integrated

MPN: ICL7126CQH-D ✓ Nakahanda
44-LCC (J-Lead) Package
MOQ: 1 |

ICL7126CQH-D Ulas

Maxim Integrated ICL7126CQH-D is a low-power 3.5-digit analog-to-digital converter with direct seven-segment LCD drive, housed in a 44-lead J-lead ceramic LCC package. It integrates the seven-segment decoders, display drivers, reference, clock, and dual-slope conversion functions on a single CMOS IC. The device is identified for commercial-grade operation and is intended for precision digital-panel-meter, laboratory, and instrumentation measurements.

An integrating dual-slope A/D converter is a voltage-to-digital conversion category that measures input voltage through controlled charge and discharge timing. The ICL7126 belongs to the broader ADC and data-conversion hierarchy, where it combines low power consumption, direct LCD output, and autonomous conversion sequencing in one package. This integration reduces the need for external display multiplexers and simplifies instruments that display measured voltage, current, resistance, or temperature.

The principal features include 3.5-digit resolution, seven-segment LCD display capability, direct LCD drive, and low-noise measurement performance. The Analog Devices product page identifies the ICL7126 as a production device and recommends ICL7136 for new designs, indicating that engineers should confirm lifecycle objectives before starting a long-lived production program. The integrated reference, clock, decoders, and display drivers are especially useful when component count, startup simplicity, and meter readability are priorities.

Operationally, the dual-slope architecture provides good rejection of periodic noise when its integration and reference timing are matched appropriately. The integrated seven-segment drivers directly energize LCD segments, while the converter's hold, polarity, and display-control pins allow the measurement sequence to be coordinated with external switches or signal conditioning. For sensitive measurements, input-source impedance, reference accuracy, layout cleanliness, and bypass-capacitor placement remain central to achieving useful resolution.

Typical uses include digital panel meters, laboratory instruments, process monitoring, laboratory scales, temperature readouts, and portable battery-powered meters. The direct LCD-drive architecture is especially helpful in compact instruments where space and low standby power are important. It can also serve as the measurement front end in educational, industrial, and service equipment requiring a stable numeric display without a separate display controller.

When laying out the circuit, keep analog input and reference connections away from LCD drive and switching nodes, and place input, reference, and bypass capacitors close to their associated pins. Confirm the required LCD segment pattern, digit blanking, common drive arrangement, and polarity against the manufacturer datasheet before fabrication. Because the exact 44-pin assignment is not reproduced on this page, use the manufacturer pin-description table when assigning PCB tracks.

This page combines manufacturer lifecycle guidance, package and converter information, verified sourcing links, and practical design considerations. It also identifies the ICL7126CQH+D suffix counterpart for cross-reference while clearly distinguishing verified pin-compatible options from broader functional alternatives.

Mga alternatibo na pwedeng ilagay na ICL7126CQH-D — parehas na package, pin-to-pin na katugmang. Hindi kasama ang mga bahagi ng iba't-ibang package na nangangailangan ng pagpapaayos ng PCB.

Variante sa Seri na ito

Katulad na modelo sa serye na katugma sa pagpasok ICL7126CQH-D (parehas na form factor at footprint) — pagkakaiba sa Display Configuration, Integrated Functions, Number of Terminals, Terminal Form.

Analog Devices
Display Configuration: 7-segment
Integrated Functions: Seven-segment decoders, display drivers, reference, and clock
Number of Terminals: 44
Ikabit sa ICL7126CQH-D →

ICL7126CQH+D

✅ Drop-In
📦 44-LCC (J-Lead)
Plus-marked second-source designation for the same 3.5-digit converter and 44-LCC package; key ratings match 100%

📋 Alternatibo na Reference (hindi sa katalogo)

ICL7126CQH-D Mga Pinakamataas na Rating at Electrical Characteristics

Converter Type Dual-slope A/D converter
Pangangasiwaan 3.5 digits
Display Configuration Seven-segment LCD
Display Drive Direct LCD drive
Packhaging 44-LCC (J-Lead)
Number of Terminals 44 terminals
Package Code QCCJ
Terminal Form J-bend
Package Shape Square
Temperature Grade Commercial
Integrated Functions Seven-segment decoders, display drivers, reference, clock, and A/D converter
Power Class Low-power CMOS A/D converter
Input Noise 15 pV peak-to-peak
Over-Range Recovery Guaranteed first-reading recovery from over-range
Zero-Input Behavior Zero input gives zero reading

Gabay sa Pin Configuration ng ICL7126CQH-D square

Pin configuration para sa ICL7126CQH-D (square package). Ang analog component na ito ay may input, output, at power supply pins. Sumangguni sa datasheet ng manufacturer para sa offset null, compensation, at enable pin configurations. Perpekto para sa signal conditioning at amplifier circuits.

Pinout diagram ng square package para sa ICL7126CQH-D

Wala ng detalyadong pinout data na magagamit para sa ICL7126CQH-D.

Sumangguni sa datasheet para sa buong pin configuration.

Tipikal na mga Gamit

ICL7126CQH-D ay nararapat para sa 6 aplikasyons: Digital Panel Meters, Laboratory Voltage Meters, Temperature Monitoring Instruments, Process Control Displays, Portable Battery Instruments, Educational Measurement Equipment.

📺

Digital Panel Meters

The ICL7126CQH-D fits digital panel meters because its 3.5-digit dual-slope converter drives seven-segment LCD displays directly, reducing the need for a separate display decoder and driver. The integrated reference, clock, decoders, and display drivers simplify a compact meter implementation, while the commercial-grade 44-LCC J-lead package supports leaded through-hole assembly. For stable measurements, keep the input path and reference network away from display nodes and verify the selected LCD segment and common-drive arrangement against the manufacturer pinout.

🧪

Laboratory Voltage Meters

The ICL7126CQH-D is appropriate for a laboratory voltage meter where a readable 3.5-digit result and low-power operation are valuable. Its dual-slope A/D architecture is suited to measuring slowly changing or quasi-static voltages, and the integrated LCD drive allows the measurement result to appear directly on the front panel. Because converter resolution does not remove errors from the front end, use high-impedance buffering, clean reference bypassing, guarded input traces, and calibrated resistor networks to preserve measurement accuracy.

🌡️

Temperature Monitoring Instruments

The ICL7126CQH-D can form the display and conversion section of a temperature-monitoring instrument when a linearized sensor signal is presented to its input. The direct seven-segment LCD drive is useful for portable handheld thermometers, industrial temperature panels, and test equipment, while the 44-terminal package provides access to measurement, reference, control, and display functions. Front-end selection determines accuracy: use an appropriate sensor amplifier and linearization network, and ensure over-range recovery supports reliable operation when the measured temperature exceeds the selected range.

🏭

Process Control Displays

The ICL7126CQH-D suits process-control panels that need a local numeric indication of a slowly varying process variable. Its dual-slope conversion method and direct LCD drive provide a simple standalone display path without requiring a separate display microcontroller. The commercial 44-LCC package is useful for industrial panel hardware, although the complete system still needs input conditioning and isolation appropriate to the measured quantity. Keep high-current relays and switching equipment away from the analog input and reference traces to prevent display instability.

🔋

Portable Battery Instruments

The low-power ICL7126CQH-D architecture supports portable battery-operated instruments that display measurements locally. Its integrated clock, reference, decoders, and drivers reduce the number of powered support components, while direct LCD drive avoids a separate display-driver stage. Power budget and startup behavior must be checked against the instrument's battery life target, and unused control or display functions should be configured according to the datasheet. Stable operation also depends on using suitable reference bypass capacitance and limiting leakage through board contamination.

🎓

Educational Measurement Equipment

The ICL7126CQH-D is suitable for educational meters, laboratory demonstrators, and instrument-building projects because it combines measurement, decoding, and display functions in one device. A 3.5-digit LCD result is intuitive for teaching basic analog-to-digital conversion, reference behavior, and input conditioning. The 44-LCC J-lead package is easy to inspect and rework on educational breadboards or through-hole prototypes. Designers should still provide the datasheet-required bypass capacitors, preserve analog grounding, and avoid assuming that a zero input produces an accurate zero if the input network is unbalanced.

Buod ng mga Inirekomendang Produkto

ICL7126CQH-D Maxim Integrated Ginagamit sa: Digital Panel Meters, Laboratory Voltage Meters, Temperature Monitoring Instruments, Process Control Displays, Portable Battery Instruments, Educational Measurement Equipment ICL7136 Manufacturer-recommended family for new designs Ginagamit sa: Digital Panel Meters, Laboratory Voltage Meters, Temperature Monitoring Instruments, Process Control Displays, Portable Battery Instruments, Educational Measurement Equipment
What is ICL7126CQH-D?
The ICL7126CQH-D is a low-power, 3.5-digit, dual-slope A/D converter with direct seven-segment LCD drive in a 44-lead J-lead LCC package. According to the Analog Devices product page, the ICL7126 integrates the A/D converter, seven-segment decoders, display drivers, reference, and clock on one CMOS IC. The C indicates the commercial temperature grade, Q identifies the ceramic leaded-chip carrier style, and H identifies the 44-terminal package configuration.
Where can I download the ICL7126CQH-D datasheet PDF?
The official ICL7126 product page is the correct starting point for the ICL7126CQH-D datasheet and supporting documentation. The Analog Devices page identifies the ICL7126 as a low-power 3.5-digit A/D converter with direct LCD drivers and links its data sheet, product selection table, hardware resources, and software resources. Use the package and ordering information to confirm that the documented CQH-D ordering code corresponds to the 44-LCC J-lead configuration used on your board.
Where can I find the ICL7126CQH-D pinout?
The ICL7126CQH-D pin assignment must be taken from the pin-description table in the manufacturer ICL7126 data sheet. The verified product information identifies a 44-LCC J-lead package with 44 terminals, but a complete numbered pin list is not published on this page. When assigning PCB tracks, use the package drawing and pin table together and confirm analog input, reference, clock, control, ground, and LCD-drive connections against the exact ordering code.
Is ICL7126CQH-D suitable for digital panel meters?
Yes, the ICL7126CQH-D is suitable for digital panel meters because it combines a 3.5-digit dual-slope converter with direct seven-segment LCD drive. Its integrated decoders, display drivers, reference, and clock reduce the external component count compared with a converter that requires a separate display controller. The commercial-grade device is appropriate for general instrumentation, although production planners should also evaluate the manufacturer's recommendation to use ICL7136 for new designs.
What is the difference between ICL7126CQH-D and ICL7126CQH+D?
ICL7126CQH-D and ICL7126CQH+D denote the same 44-LCC commercial-grade ICL7126 device ordering family, with the plus sign identifying Maxim Integrated's improved second-source designation. The verified product comparison describes the plus-marked device as a low-power 3.5-digit A/D converter with direct LCD drive and improved second-source status. Before substitution, confirm that the completed manufacturer part number resolves to the same package, temperature grade, pinout, and datasheet revision.
Is ICL7126CQH-D in stock?
Current inventory changes by seller and region, so use the Request a Quote form on this page to request the latest ICL7126CQH-D stock status, packaged quantity, and lead time. The manufacturer lists the ICL7126 as a production device and provides a product-selection table, while the verified distributor result identifies the CQH-D ordering code. A quotation request allows the current supply position to be checked for the exact suffix without relying on an outdated stock count.
What is the price of ICL7126CQH-D?
The current unit price for ICL7126CQH-D should be requested through the Request a Quote form on this page. Pricing can vary with order quantity, package suffix, date, and supply status, and the manufacturer product page displays a starting list-price reference rather than a complete quantity-break schedule for this exact ordering code. Submit the required quantity and target package details so the quotation can reflect current component availability.
What is the lead time for ICL7126CQH-D?
The current lead time for ICL7126CQH-D should be confirmed through the Request a Quote form on this page. Lead time depends on factory inventory, purchase quantity, and the requested delivery schedule, and it cannot be established from a static distributor search result. Include the required annual usage, prototype quantity, and production schedule in the request so sourcing can determine an appropriate allocation and delivery commitment.
Can ICL7126CQH-D replace an ICL7136?
The ICL7126CQH-D should not be treated as a pin-for-pin ICL7136 replacement without checking both datasheets. The manufacturer identifies the ICL7126 as a low-power 3.5-digit converter and recommends ICL7136 for new designs, but that recommendation alone does not establish package, pin, or feature equivalence. Use the ICL7136 as the basis for a new design when its lifecycle, electrical limits, and display interface better match the target instrument.
What is the best drop-in replacement for ICL7126CQH-D?
The ICL7126CQH+D is the closest identified suffix counterpart for ICL7126CQH-D because it represents the same commercial-grade 44-LCC converter ordering family and is explicitly presented in a direct comparison. No broader cross-brand replacement is established here as pin-to-pin compatible. For a production substitution, confirm the complete pinout, operating limits, reference behavior, LCD drive arrangement, and package tolerances against the manufacturer documentation before approving the change.
Is ICL7126CQH-D the same as ICL7126CQH+D?
Yes, ICL7126CQH+D is the plus-marked ordering designation associated with the same ICL7126CQH-D device family and 44-LCC commercial-grade package. The plus designation communicates an improved second-source device according to the verified product comparison. It should not change the basic 3.5-digit, dual-slope, direct-LCD-drive function, although engineers should verify the exact ordering code and current datasheet before treating the two suffixes as interchangeable.
When should I choose ICL7126CQH-D instead of ICL7136?
Choose ICL7126CQH-D when maintaining an existing 44-LCC instrument is more important than adopting the manufacturer's newest recommended family for new designs. The ICL7126 provides a 3.5-digit dual-slope conversion function with direct LCD drive, making it suitable for established panel-meter designs. For a new product, evaluate ICL7136 first because Analog Devices explicitly recommends it for new designs, then confirm package, lifecycle, and functional compatibility.
What are the key specifications of ICL7126CQH-D that engineers should know?
The key ICL7126CQH-D specifications are 3.5-digit resolution, dual-slope conversion, direct seven-segment LCD drive, a 44-LCC J-lead package, and commercial-grade temperature class. The device integrates the reference, clock, decoders, and display drivers on one CMOS IC. Its listed 15 pV peak-to-peak noise and guaranteed first-reading recovery from over-range are particularly relevant to low-level instrumentation, while power-supply and reference-decoupling layout remain important.
How does ICL7126CQH-D reject noise?
The ICL7126CQH-D uses a dual-slope integrating conversion architecture, which is useful for rejecting periodic disturbances when the integration and reference timing are correctly related. The manufacturer also lists 15 pV peak-to-peak input noise and guaranteed recovery of the first reading after an over-range event. Actual system noise depends on input impedance, source impedance, reference quality, grounding, shielding, and PCB cleanliness, so the complete measurement chain must be evaluated rather than the converter alone.
Does ICL7126CQH-D meet automotive or RoHS requirements?
The ICL7126CQH-D is identified as a commercial-grade component, so automotive qualification should not be assumed. The verified information does not establish its RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals status. Obtain the current manufacturer product declarations for the exact ordering code before using the device in a regulated production design. For an automotive instrument, select a part with explicit AEC-Q100 qualification instead of inferring suitability from the ICL7126 family name.

Impormasyon ng Talumpati sa Engineering for ICL7126CQH-D — ikabit, gabay sa disenyo, at impormasyon ng pagsunod sa kautusan.

Paunawang Hanapin

Choose ICL7126CQH-D when maintaining an existing 3.5-digit LCD panel-meter design, especially one built around the 44-LCC J-lead footprint and commercial-temperature version of the ICL7126. The integrated dual-slope converter, reference, clock, decoders, and display drivers provide a compact measurement-display solution without a separate display controller. ICL7126CQH+D is the closest identified suffix counterpart and can be considered for the same board position after confirming ordering-code, datasheet, and lifecycle details. For a completely new instrument, evaluate ICL7136 first because the manufacturer explicitly recommends it for new designs; it should not be treated as a drop-in replacement without a detailed pin, package, electrical, and lifecycle comparison. Other converter families may offer different resolution, interface, package, or automotive qualification, but no additional cross-brand part was established as a verified pin-compatible substitute.

Ikabit sa Mga Alternatibo

Parametro Ito ang Producto ICL7126CQH+D
Brand Maxim Integrated Maxim Integrated
Package 44-LCC (J-Lead) 44-LCC (J-Lead)
Converter Type Dual-slope A/D converter Dual-slope A/D converter
Resolution 3.5 digits 3.5 digits
Display Configuration Seven-segment LCD Seven-segment LCD
Display Drive Direct LCD drive Direct LCD drive
Temperature Grade Commercial Commercial
Input Noise 15 pV peak-to-peak 15 pV peak-to-peak
Number of Terminals 44 terminals 44 terminals

Pangunahing mga Pagkakaiba

  • Integrated measurement and LCD-display function (kumpara saICL7126CQH+D)
  • Compatible commercial-grade 44-LCC mechanical format (kumpara saICL7126CQH+D)
  • Identical direct LCD measurement feature set (kumpara saICL7126CQH+D)

Talaan ng Disenyo

Separate the analog measurement area from LCD drive and other switching nodes. Route the converter input and reference connections as short, guarded traces, and place the required input, reference, and bypass capacitors close to the associated device pins. The J-lead package provides generous spacing between leads, but lead spacing alone does not prevent capacitive coupling. Use a continuous ground plane where practical and keep high-impedance input traces away from clock and display-driver tracks.

Input-source impedance materially affects the usable resolution and settling behavior of a integrating A/D converter. Use the manufacturer input-capacitance and acquisition guidance to select the source impedance, and avoid excessive cable length in low-level measurement paths. If the source is high impedance, add suitable guarding, shielding, or local input buffering. Validate the complete front end with the intended source rather than evaluating the converter in isolation.

Do not infer LCD compatibility from the digit count alone. Confirm the segment mapping, digit count, common-drive configuration, drive levels, and polarity for the actual display using the device data sheet and display documentation. Also verify the package's pin-one orientation and all 44 terminal assignments before fabrication. A display that appears correct on a breadboard can still fail in production if unused drive or control pins are left in the wrong state.

Impormasyon ng Pagsunod sa Kautusan

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Walang Lead
Unknown
Walang Halogen
Unknown
Mga Conflict Mineral
Unknown

The device is identified as commercial grade. RoHS, REACH, lead-free, halogen-free, and conflict-minerals declarations were not identified for the exact ordering code.

Data napatotohanan sa: 2026-11-24 — impormasyon na pinatunayan at pinapatakbo ng pangkat ng engineering ng XAIPART's component engineering team

Kaugnay na Hanapin

ICL7126CQH-D datasheet ICL7126CQH-D pinout ICL7126CQH-D datasheet pdf ICL7126CQH-D equivalent ICL7126CQH-D replacement ICL7126CQH-D cross reference ICL7126CQH-D 44-LCC ICL7126CQH-D price ICL7126CQH-D stock Maxim Integrated ICL7126CQH-D ICL7126 3.5 digit LCD ADC ICL7126CQH-D vs ICL7126CQH+D

Mga kaugnay na Mga Komponente at mga Tuntunin

Maxim Integrated ICL7126CQH-D ICL7126CQH+D ICL7126 ICL7136 dual-slope A/D converter analog-to-digital converter ADC data converter integrating converter 3.5-digit resolution seven-segment LCD direct LCD drive 44-LCC J-Lead package ceramic leaded-chip carrier QCCJ package code commercial temperature grade CMOS integrated circuit integrated reference integrated clock low-power instrumentation digital panel meter input noise over-range recovery surface mount
Mabilis na Tanggap na RFQ
Ihanda ang buong detalye — ang aming pangkalakal na koponan ay tutugon sa loob ng 24 oras
Numero ng Parte Mga Tagagawa Pakete QTY Target na Halaga Pinalawak
✓
Quote na inilabas!

Ating tumugon sa iyong email sa loob ng 24 oras

1
RFQ Naisumite
2
Received na ang Kwaliksik
3
Nai-order
4
Pagbabayad
5
Inihanda
6
Naihanda
Tingnan ang Detalye ng RFQ