ICL7126CQH-D - 3.5-Digit LCD ADC | Maxim Integrated
MPN: ICL7126CQH-D ✓ Hoạt độngICL7126CQH-D Tóm tắt
An integrating dual-slope A/D converter is a voltage-to-digital conversion category that measures input voltage through controlled charge and discharge timing. The ICL7126 belongs to the broader ADC and data-conversion hierarchy, where it combines low power consumption, direct LCD output, and autonomous conversion sequencing in one package. This integration reduces the need for external display multiplexers and simplifies instruments that display measured voltage, current, resistance, or temperature.
The principal features include 3.5-digit resolution, seven-segment LCD display capability, direct LCD drive, and low-noise measurement performance. The Analog Devices product page identifies the ICL7126 as a production device and recommends ICL7136 for new designs, indicating that engineers should confirm lifecycle objectives before starting a long-lived production program. The integrated reference, clock, decoders, and display drivers are especially useful when component count, startup simplicity, and meter readability are priorities.
Operationally, the dual-slope architecture provides good rejection of periodic noise when its integration and reference timing are matched appropriately. The integrated seven-segment drivers directly energize LCD segments, while the converter's hold, polarity, and display-control pins allow the measurement sequence to be coordinated with external switches or signal conditioning. For sensitive measurements, input-source impedance, reference accuracy, layout cleanliness, and bypass-capacitor placement remain central to achieving useful resolution.
Typical uses include digital panel meters, laboratory instruments, process monitoring, laboratory scales, temperature readouts, and portable battery-powered meters. The direct LCD-drive architecture is especially helpful in compact instruments where space and low standby power are important. It can also serve as the measurement front end in educational, industrial, and service equipment requiring a stable numeric display without a separate display controller.
When laying out the circuit, keep analog input and reference connections away from LCD drive and switching nodes, and place input, reference, and bypass capacitors close to their associated pins. Confirm the required LCD segment pattern, digit blanking, common drive arrangement, and polarity against the manufacturer datasheet before fabrication. Because the exact 44-pin assignment is not reproduced on this page, use the manufacturer pin-description table when assigning PCB tracks.
This page combines manufacturer lifecycle guidance, package and converter information, verified sourcing links, and practical design considerations. It also identifies the ICL7126CQH+D suffix counterpart for cross-reference while clearly distinguishing verified pin-compatible options from broader functional alternatives.
Bộ thay thế dễ dàng lắp đặt cho ICL7126CQH-D — cùng gói, chân-to-chân tương thích. Các bộ phận yêu cầu hàn PCB bị loại trừ.
Các biến thể trong loạt này
Các mẫu cùng loạt có thể lắp đặt dễ dàng tương thích với ICL7126CQH-D (cùng hình factor và footprint) — khác nhau ở Display Configuration, Integrated Functions, Number of Terminals, Terminal Form.
ICL7126CQH+D
✅ Drop-In📋 Tham chiếu thay thế (không có trong danh mục)
ICL7126CQH-D Tỷ lệ tối đa & tính chất điện
| Converter Type | Dual-slope A/D converter |
| Độ phân giải | 3.5 digits |
| Display Configuration | Seven-segment LCD |
| Display Drive | Direct LCD drive |
| Hộp | 44-LCC (J-Lead) |
| Number of Terminals | 44 terminals |
| Package Code | QCCJ |
| Terminal Form | J-bend |
| Package Shape | Square |
| Temperature Grade | Commercial |
| Integrated Functions | Seven-segment decoders, display drivers, reference, clock, and A/D converter |
| Power Class | Low-power CMOS A/D converter |
| Input Noise | 15 pV peak-to-peak |
| Over-Range Recovery | Guaranteed first-reading recovery from over-range |
| Zero-Input Behavior | Zero input gives zero reading |
Hướng dẫn cấu hình chân ICL7126CQH-D square
Cấu hình chân cho ICL7126CQH-D (square gói). Thành phần số hiệu này có chân đầu vào, đầu ra và nguồn cung cấp. Tham khảo tài liệu thông số kỹ thuật của nhà sản xuất để biết cấu hình chân bù, bù trừ và chân kích hoạt. Hoàn hảo cho điều kiện tín hiệu và mạch khuếch đại.
Không có dữ liệu chân cụ thể sẵn có cho ICL7126CQH-D.
Tham khảo: tài liệu kỹ thuật cho cấu hình chân đầy đủ.
Ứng dụng tiêu biểu
ICL7126CQH-D phù hợp cho 6 Áp dụngs: Digital Panel Meters, Laboratory Voltage Meters, Temperature Monitoring Instruments, Process Control Displays, Portable Battery Instruments, Educational Measurement Equipment.
Digital Panel Meters
The ICL7126CQH-D fits digital panel meters because its 3.5-digit dual-slope converter drives seven-segment LCD displays directly, reducing the need for a separate display decoder and driver. The integrated reference, clock, decoders, and display drivers simplify a compact meter implementation, while the commercial-grade 44-LCC J-lead package supports leaded through-hole assembly. For stable measurements, keep the input path and reference network away from display nodes and verify the selected LCD segment and common-drive arrangement against the manufacturer pinout.
Được đề xuất
Laboratory Voltage Meters
The ICL7126CQH-D is appropriate for a laboratory voltage meter where a readable 3.5-digit result and low-power operation are valuable. Its dual-slope A/D architecture is suited to measuring slowly changing or quasi-static voltages, and the integrated LCD drive allows the measurement result to appear directly on the front panel. Because converter resolution does not remove errors from the front end, use high-impedance buffering, clean reference bypassing, guarded input traces, and calibrated resistor networks to preserve measurement accuracy.
Được đề xuất
Temperature Monitoring Instruments
The ICL7126CQH-D can form the display and conversion section of a temperature-monitoring instrument when a linearized sensor signal is presented to its input. The direct seven-segment LCD drive is useful for portable handheld thermometers, industrial temperature panels, and test equipment, while the 44-terminal package provides access to measurement, reference, control, and display functions. Front-end selection determines accuracy: use an appropriate sensor amplifier and linearization network, and ensure over-range recovery supports reliable operation when the measured temperature exceeds the selected range.
Được đề xuất
Process Control Displays
The ICL7126CQH-D suits process-control panels that need a local numeric indication of a slowly varying process variable. Its dual-slope conversion method and direct LCD drive provide a simple standalone display path without requiring a separate display microcontroller. The commercial 44-LCC package is useful for industrial panel hardware, although the complete system still needs input conditioning and isolation appropriate to the measured quantity. Keep high-current relays and switching equipment away from the analog input and reference traces to prevent display instability.
Được đề xuất
Portable Battery Instruments
The low-power ICL7126CQH-D architecture supports portable battery-operated instruments that display measurements locally. Its integrated clock, reference, decoders, and drivers reduce the number of powered support components, while direct LCD drive avoids a separate display-driver stage. Power budget and startup behavior must be checked against the instrument's battery life target, and unused control or display functions should be configured according to the datasheet. Stable operation also depends on using suitable reference bypass capacitance and limiting leakage through board contamination.
Được đề xuất
Educational Measurement Equipment
The ICL7126CQH-D is suitable for educational meters, laboratory demonstrators, and instrument-building projects because it combines measurement, decoding, and display functions in one device. A 3.5-digit LCD result is intuitive for teaching basic analog-to-digital conversion, reference behavior, and input conditioning. The 44-LCC J-lead package is easy to inspect and rework on educational breadboards or through-hole prototypes. Designers should still provide the datasheet-required bypass capacitors, preserve analog grounding, and avoid assuming that a zero input produces an accurate zero if the input network is unbalanced.
Được đề xuất
Tóm tắt các sản phẩm được đề xuất
Dữ liệu tham khảo kỹ thuật cho ICL7126CQH-D — so sánh, hướng dẫn thiết kế và thông tin tuân thủ.
Hướng dẫn chọn lựa
So sánh với các sản phẩm thay thế
| Tham số | Sản phẩm này | ICL7126CQH+D |
|---|---|---|
| Brand | Maxim Integrated | Maxim Integrated |
| Package | 44-LCC (J-Lead) | 44-LCC (J-Lead) |
| Converter Type | Dual-slope A/D converter | Dual-slope A/D converter |
| Resolution | 3.5 digits | 3.5 digits |
| Display Configuration | Seven-segment LCD | Seven-segment LCD |
| Display Drive | Direct LCD drive | Direct LCD drive |
| Temperature Grade | Commercial | Commercial |
| Input Noise | 15 pV peak-to-peak | 15 pV peak-to-peak |
| Number of Terminals | 44 terminals | 44 terminals |
Bảo phân biệt quan trọng
- Integrated measurement and LCD-display function (vsICL7126CQH+D)
- Compatible commercial-grade 44-LCC mechanical format (vsICL7126CQH+D)
- Identical direct LCD measurement feature set (vsICL7126CQH+D)
Ghi chú thiết kế
Separate the analog measurement area from LCD drive and other switching nodes. Route the converter input and reference connections as short, guarded traces, and place the required input, reference, and bypass capacitors close to the associated device pins. The J-lead package provides generous spacing between leads, but lead spacing alone does not prevent capacitive coupling. Use a continuous ground plane where practical and keep high-impedance input traces away from clock and display-driver tracks.
Input-source impedance materially affects the usable resolution and settling behavior of a integrating A/D converter. Use the manufacturer input-capacitance and acquisition guidance to select the source impedance, and avoid excessive cable length in low-level measurement paths. If the source is high impedance, add suitable guarding, shielding, or local input buffering. Validate the complete front end with the intended source rather than evaluating the converter in isolation.
Do not infer LCD compatibility from the digit count alone. Confirm the segment mapping, digit count, common-drive configuration, drive levels, and polarity for the actual display using the device data sheet and display documentation. Also verify the package's pin-one orientation and all 44 terminal assignments before fabrication. A display that appears correct on a breadboard can still fail in production if unused drive or control pins are left in the wrong state.
Thông tin tuân thủ
The device is identified as commercial grade. RoHS, REACH, lead-free, halogen-free, and conflict-minerals declarations were not identified for the exact ordering code.