INA125TDA1 - Precision Instrumentation Amplifier Die | TI
MPN: INA125TDA1 ✓ NakahandaINA125TDA1 Ulas
An instrumentation amplifier is a specialized analog amplifier that measures the voltage difference between two inputs while rejecting signals common to both inputs. Within the amplifier hierarchy, an instrumentation amplifier is a differential amplifier optimized for high input impedance, accurate gain control, and excellent common-mode rejection. This makes it more useful than a general-purpose operational amplifier for sensor outputs, bridge circuits, and other systems where large common-mode voltages may coexist with a small differential signal.
The INA125TDA1 provides a gain of up to 10,000, a minimum CMRR of 107 dB, and a nominal bandwidth of 0.15 MHz. Its integrated precision voltage reference can support bridge excitation and other measurement systems that require an internal reference. The listed maximum input bias current of 0.025 uA is also useful in high-impedance sensor applications because it minimizes disturbance of the source being measured.
Internally, the device combines instrumentation-amplifier signal conditioning with a precision reference in one circuit. The broad gain range supports applications ranging from moderate-level sensor signals to millivolt-level inputs. Because gain and bandwidth trade against one another in practical signal chains, the usable bandwidth generally decreases at higher gains, so the selected gain must be checked against the required measurement bandwidth and settling behavior.
Typical uses include load-cell and strain-gauge front ends, precision bridge measurement, low-level differential sensing, industrial instrumentation, and laboratory signal conditioning. The die format is particularly relevant to manufacturers that require bare-die assembly, wafer-level integration, or customized packaging rather than a standard leaded or surface-mount package.
Design work should begin with the manufacturer's INA125 pin-description table and electrical-characteristics table because the exposed die requires assembly-specific bonding and the exact terminal assignments are critical. Designers should also verify gain-set resistor values, reference loading, supply headroom, output swing, input common-mode limits, and the bandwidth required at the selected gain before releasing a production design.
This page combines the die-level device information, verified pricing record, functional family comparisons, and application-specific engineering guidance to support sourcing and design decisions. It distinguishes the bare-die INA125TDA1 from packaged INA125 devices and emphasizes why package, pinout, qualification, and thermal requirements must be verified during replacement planning.
Mga alternatibo na pwedeng ilagay na INA125TDA1 — parehas na package, pin-to-pin na katugmang. Hindi kasama ang mga bahagi ng iba't-ibang package na nangangailangan ng pagpapaayos ng PCB.
Wala ng magagamit na drop-in alternatibo para sa produkto na ito.
Hilingin ang AlternatiboINA125TDA1 Mga Pinakamataas na Rating at Electrical Characteristics
| Device Type | Single-circuit instrumentation amplifier with precision voltage reference |
| Number of Circuits | 1 circuit |
| Maximum Voltage Gain | 10,000 V/V |
| Minimum Common-Mode Rejection Ratio | 107 dB |
| Nominal Bandwidth | 0.15 MHz |
| Maximum Average Bias Current | 0.025 uA |
| Package Type | Rectangular die |
| Number of Terminals | 17 terminals |
| Die Width | 1.9558 mm |
| Mounting Form | No-lead die assembly |
| Reference | Integrated precision voltage reference |
| Input Type | Differential input |
| Common-Mode Rejection | 107 dB minimum |
Gabay sa Pin Configuration ng INA125TDA1 rectangular die
Pin configuration para sa INA125TDA1 (rectangular die package). Ang analog component na ito ay may input, output, at power supply pins. Sumangguni sa datasheet ng manufacturer para sa offset null, compensation, at enable pin configurations. Perpekto para sa signal conditioning at amplifier circuits.
Wala ng detalyadong pinout data na magagamit para sa INA125TDA1.
Sumangguni sa datasheet para sa buong pin configuration.
Tipikal na mga Gamit
INA125TDA1 ay nararapat para sa 6 aplikasyons: Load-Cell Front End, Precision Bridge Measurement, Low-Level Differential Sensing, Industrial Instrumentation, Laboratory Signal Conditioning, Custom Semiconductor Integration.
Load-Cell Front End
The INA125TDA1 fits load-cell and strain-gauge measurements that produce small differential signals in the presence of a much larger common-mode bridge excitation. Its maximum voltage gain of 10,000 supports high-gain signal extraction, while the 107 dB minimum common-mode rejection ratio helps prevent excitation voltage from dominating the measurement. The integrated precision voltage reference can support bridge-oriented designs. During implementation, verify the actual bridge excitation scheme, gain-set resistor network, input common-mode limits, output swing, and the 0.15 MHz nominal bandwidth at the intended gain.
Inirekomenda
Precision Bridge Measurement
INA125TDA1 is appropriate for precision bridge excitation and readout circuits where excitation accuracy, common-mode rejection, and differential gain determine measurement quality. A maximum gain of 10,000 can increase millivolt-level bridge imbalance to a more useful output range, while the integrated precision voltage reference provides a local reference option. The design must account for gain-dependent bandwidth, reference stability, bridge impedance, resistor tolerance, and input bias current. A custom die assembly also requires a controlled pad map, orientation procedure, and electrical test plan.
Inirekomenda
Low-Level Differential Sensing
The INA125TDA1 can condition low-level differential outputs from sensors when the design benefits from high common-mode rejection rather than a conventional single-ended amplifier stage. Its 0.025 uA maximum average bias current is favorable for high-impedance sources, while the 107 dB minimum CMRR helps reject shared noise or voltage on both inputs. Engineers should verify whether the sensor output is truly differential, confirm the usable bandwidth at the selected gain, and keep routing symmetrical to minimize conversion of common-mode disturbance into differential error.
Inirekomenda
Industrial Instrumentation
INA125TDA1 supports custom industrial instrumentation that must amplify differential sensor signals under varying common-mode conditions. The high maximum gain of 10,000 and 107 dB minimum CMRR provide useful headroom for low-amplitude process measurements, while the precision reference supports systems requiring a controlled internal reference. For factory equipment, the die should be integrated into a qualified assembly with stable thermal behavior, protected routing, clean grounding, and appropriate calibration. Validate the complete channel against environmental noise, electrical isolation requirements, and long-term offset and drift performance.
Inirekomenda
Laboratory Signal Conditioning
INA125TDA1 can serve as the analog front end of a laboratory measurement instrument when small differential signals require adjustable gain and strong common-mode rejection. Its maximum gain of 10,000 accommodates sensitive sensor and bridge inputs, and the integrated precision voltage reference may simplify reference architecture for specialized equipment. Instrument designers should account for the nominal 0.15 MHz bandwidth, gain-bandwidth behavior, settling requirements, input capacitance, and output-drive limitations. Bare-die assembly also makes thermal characterization and post-assembly calibration especially relevant to instrument-level accuracy.
Inirekomenda
Custom Semiconductor Integration
The rectangular 17-terminal die format makes INA125TDA1 suitable for manufacturers integrating the INA125 directly into a custom module, wafer-level assembly, or application-specific semiconductor package. The 1.9558 mm listed die width provides a physical constraint for bonding and layout planning, while the single-circuit instrumentation amplifier and precision reference support a compact analog front end. Integration engineering must define pad assignment, die orientation, clean handling, wire-bond or flip-chip parameters, heat dissipation, continuity tests, and final calibration. The finished assembly should be validated against the electrical performance of the packaged INA125 family.
Inirekomenda
Buod ng mga Inirekomendang Produkto
Impormasyon ng Talumpati sa Engineering for INA125TDA1 — ikabit, gabay sa disenyo, at impormasyon ng pagsunod sa kautusan.
Paunawang Hanapin
Ikabit sa Mga Alternatibo
| Parametro | Ito ang Producto |
|---|---|
| Package | Rectangular 17-terminal die |
| Brand | Texas Instruments |
| Circuit Count | 1 circuit |
| Maximum Voltage Gain | 10,000 V/V |
| Minimum Common-Mode Rejection Ratio | 107 dB |
| Nominal Bandwidth | 0.15 MHz |
| Maximum Average Bias Current | 0.025 uA |
| Integrated Reference | Precision voltage reference |
Pangunahing mga Pagkakaiba
- Bare-die integration format (kumpara saINA128)
- Integrated precision voltage reference (kumpara saINA828)
- High common-mode rejection (kumpara saINA128)
Talaan ng Disenyo
Use the manufacturer terminal-description table to create the bonding map before layout work begins. Maintain symmetrical routing between the differential inputs, place gain-setting components close to their specified terminals, and provide a low-impedance return for every supply and reference connection. Because the device is supplied as a die, document die orientation, pad numbering, bond sequence, and inspection criteria as part of the assembly drawing rather than relying on a conventional package land pattern.
Treat the input network, reference connection, and output path as high-impedance precision analog routes. Keep copper and switching nodes away from the die pads, use short differential connections, and return analog current through a quiet ground structure. The 0.15 MHz nominal bandwidth should be treated as a starting characteristic rather than a guaranteed bandwidth at every gain; verify gain-bandwidth behavior, settling, capacitive loading, and output drive in the manufacturer electrical-characteristics table.
Do not substitute a packaged INA125 variant or a different instrumentation-amplifier family solely by function. The die dimensions, terminal count, pad assignment, reference implementation, gain network, and package parasitics can differ materially. Before releasing a replacement, compare input common-mode range, output swing, gain error, CMRR, offset, noise, bandwidth, supply range, and reference performance, then repeat thermal and functional testing after the new assembly is built.
Develop a thermal plan around the assembled die, copper, substrate, bond wires, and enclosure rather than the die alone. The listed die width of 1.9558 mm does not establish junction temperature or allowable dissipation, and those figures cannot be inferred without the assembly geometry and operating conditions. Correlate temperature-sensitive measurements during characterization, define safe handling limits for assembly, and verify production calibration across the intended ambient range.
Impormasyon ng Pagsunod sa Kautusan
No explicit RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals status is stated for this die ordering option. Confirm the applicable quality and environmental documentation with Texas Instruments before qualification.