SI3226-E-FQ - Dual ProSLIC Telecom Interface | Skyworks Solutions
MPN: SI3226-E-FQ ✓ NakahandaSI3226-E-FQ Ulas
The SI3226-E-FQ belongs to the ProSLIC family of integrated voice and line-interface circuits. A Subscriber Line Interface Concept, or SLIC, provides the analog termination and control functions required to connect a telephone line to a digital voice system. In combination with a linefeed interface circuit, the SI3226-E-FQ can implement a complete two-channel analog telephone interface while operating from a single 3.3 V supply. This integration reduces the number of external interface functions required in a voice-access design.
Key documented characteristics include two integrated SLIC channels, single-supply operation at 3.3 V, support for PCM, SPI, or GCI digital interfaces, and a 64-TQFP package with a 10 mm by 10 mm body. The device is identified as RoHS compliant and uses a PQFP/TQFP-style 64-pin package. Its architecture is intended for telecommunications equipment where a compact, integrated two-channel subscriber-line interface is preferred over a collection of separate analog and codec functions.
The SI3226x family is described by the manufacturer as implementing two complete FXS telephony interfaces in one package. That architecture is particularly useful when a system must support two analog phone lines while exchanging voice data with a host processor or digital transport device. The host-side digital interface handles control and PCM traffic, while the analog side implements the subscriber-line termination functions required for voice service.
Typical telecom applications include Voice over IP endpoint boards, analog telephone gateways, digital loop carrier equipment, embedded voice systems, and customer-premises telephony products. The 3.3 V supply requirement simplifies power architecture compared with designs requiring separate higher-voltage line-interface rails. The 64-TQFP footprint is mechanically substantial for a high-pin-count mixed-signal device but remains compatible with conventional surface-mount PCB assembly.
When designing around the SI3226-E-FQ, preserve the manufacturer’s recommended line-interface topology and separate the sensitive analog line side from digital clocks and switching circuitry. Confirm external component values, termination requirements, digital-interface timing, and thermal performance against the manufacturer’s current datasheet and reference design before release to production.
Mga alternatibo na pwedeng ilagay na SI3226-E-FQ — parehas na package, pin-to-pin na katugmang. Hindi kasama ang mga bahagi ng iba't-ibang package na nangangailangan ng pagpapaayos ng PCB.
Variante sa Seri na ito
Katulad na modelo sa serye na katugma sa pagpasok SI3226-E-FQ (parehas na form factor at footprint) — pagkakaiba sa Package, Product Type, Supply Voltage.
SI3226-E-GQ
✅ Drop-InMagkontak para sa presyo
Tingnan ang Datasheet →SI3226-E-FQ Mga Spesipikasyon
| Product Type | Subscriber Line Interface Concept (SLIC) and CODEC |
| Number of Channels | 2 channels |
| Volte ng Pagbibigay | 3.3 V single supply |
| Digital Interface | PCM, SPI, or GCI |
| Packhaging | 64-TQFP |
| Package Body Size | 10 mm x 10 mm |
| Uri ng Pagpapasok | Surface mount |
| Telephone Interface | Two complete FXS telephony interfaces |
| Technology | CMOS |
| Package Outline Reference | MS-026ACD |
| Tindminan RoHS | Compliant |
| Lead Status | Lead-free |
| Bilang ng Pins | 64 pins |
| Linefeed Requirement | External linefeed IC required for complete analog telephone interface |
Gabay sa Pin Configuration ng SI3226-E-FQ ms-026acd
Pin configuration para sa SI3226-E-FQ (ms-026acd package). Ang pagnunumero ng pin, mga function, at connection diagram ay tinukoy sa datasheet ng manufacturer. Sumangguni dito para sa eksaktong footprint at mga alituntunin sa soldering.
Wala ng detalyadong pinout data na magagamit para sa SI3226-E-FQ.
Sumangguni sa datasheet para sa buong pin configuration.
Tipikal na mga Gamit
SI3226-E-FQ ay nararapat para sa 6 aplikasyons: Voice over IP Analog Gateway, Two-Port Analog Telephone Adapter, Digital Loop Carrier Subscriber Node, Embedded Voice Communication Appliance, Industrial Voice Monitoring Terminal, Customer Premises Voice Access Unit.
Voice over IP Analog Gateway
The SI3226-E-FQ fits a two-line Voice over IP gateway because it integrates two FXS telephony interfaces into one 64-TQFP device and operates from a single 3.3 V supply. A host processor can exchange PCM or control traffic through the supported digital interface while the analog section connects each subscriber line. This architecture reduces the number of separate SLIC devices required for a two-port gateway and keeps the supply rail count relatively simple. Confirm host clocking, linefeed selection, channel timing, and voice-path parameters against the manufacturer’s reference design before production.
Inirekomenda
Two-Port Analog Telephone Adapter
The SI3226-E-FQ supports a compact two-port analog telephone adapter by providing two subscriber-line interface channels with digital connectivity to the adapter’s voice processor. Its single 3.3 V operating supply simplifies power planning compared with a system using multiple line-interface components. The 10 mm by 10 mm 64-TQFP package provides ample pins for power, control, digital communication, and analog connections. Final board design must follow the manufacturer’s recommended linefeed topology, component values, isolation strategy, and routing guidance for sensitive analog line signals.
Inirekomenda
Digital Loop Carrier Subscriber Node
The SI3226-E-FQ is suitable for the subscriber-node section of a digital loop carrier because it implements two FXS interfaces and supports PCM, SPI, or GCI digital connectivity. A carrier processor can therefore control voice channels through a common digital bus while the ProSLIC handles the analog subscriber side. The 3.3 V single-supply architecture helps limit power-conversion complexity in space-constrained access nodes. Verify line capacitance, on-hook power behavior, ring cadence, digital latency, and system timing with the manufacturer’s electrical specifications for each deployment profile.
Inirekomenda
Embedded Voice Communication Appliance
The SI3226-E-FQ can provide two analog telephone ports in an embedded voice appliance that bridges legacy handsets or fax equipment with a digital voice system. Its dual-channel ProSLIC configuration avoids using two separate codec-plus-line-interface assemblies, while the digital interface links the device to an embedded processor or communications controller. The 3.3 V supply operation supports compact power-system design. Designers should verify boot sequencing, firmware or host-driver requirements, ring voltage generation through the external linefeed path, and thermal performance in the final enclosure.
Inirekomenda
Industrial Voice Monitoring Terminal
The SI3226-E-FQ is appropriate for industrial voice terminals that need one or two analog line interfaces for monitoring, intercom, or remote communications equipment. Its two channels allow a single device to manage multiple subscriber-facing ports, while PCM, SPI, or GCI connectivity supports integration with a digital controller. The single 3.3 V supply is useful in industrial embedded systems with a common low-voltage rail. The design should include isolation and surge protection appropriate to external telephone lines, and all protection networks should be validated against the manufacturer’s reference schematic.
Inirekomenda
Customer Premises Voice Access Unit
The SI3226-E-FQ is well suited to a customer-premises voice access unit requiring two analog FXS services with digital backhaul. A central processor can manage call control and voice transport while the integrated ProSLIC provides the subscriber-side analog interface. Its 3.3 V single-supply operation can simplify system-level power design, and the dual-channel arrangement reduces component count on a dense voice-access board. Engineering review should include thermal rise, linefeed component selection, PCB creepage requirements, digital trace isolation, and compatibility with the selected host processor’s PCM or GCI implementation.
Inirekomenda
Buod ng mga Inirekomendang Produkto
Impormasyon ng Talumpati sa Engineering for SI3226-E-FQ — ikabit, gabay sa disenyo, at impormasyon ng pagsunod sa kautusan.
Paunawang Hanapin
Ikabit sa Mga Alternatibo
| Parametro | Ito ang Producto | SI3226-E-GQ |
|---|---|---|
| Brand | Skyworks Solutions | Skyworks Solutions |
| Package | 64-TQFP, 10 mm x 10 mm | 64-TQFP, 10 mm x 10 mm |
| Device Type | Dual-channel SLIC/CODEC | Dual-channel SLIC/CODEC |
| Number of Channels | 2 channels | 2 channels |
| Supply Voltage | 3.3 V single supply | 3.3 V single supply |
| Digital Interface | PCM, SPI, or GCI | PCM, SPI, or GCI |
| Telephone Interface | Two FXS interfaces | Two FXS interfaces |
| Linefeed Arrangement | External linefeed IC required | External linefeed IC required |
| Technology | CMOS | CMOS |
Pangunahing mga Pagkakaiba
- Integrates two FXS channels in one device (kumpara saSI3226-E-GQ)
- Single 3.3 V architecture simplifies supply design (kumpara saSI3226-E-GQ)
- Supports flexible host connectivity (kumpara saSI3226-E-GQ)
Talaan ng Disenyo
Separate the sensitive analog subscriber-line region from digital clock, control, and switching-node circuitry. Follow the manufacturer’s reference layout for linefeed components, analog ground connections, and digital-interface routing, and maintain the documented spacing around line-connected nodes. Do not route high-energy switching or isolation-network return currents beneath the analog section, because coupling into the SLIC can degrade voice-channel performance.
Build the 3.3 V supply with local high-frequency bypass at the IC power pins and separate analog and digital return-current paths as recommended in the manufacturer reference design. Confirm capacitor voltage rating, DC-bias characteristics, and placement against the current datasheet. Validate startup, rail sequencing, and linefeed power states because subscriber-line interfaces combine low-voltage digital control with externally influenced analog line conditions.
Do not treat the ProSLIC as a complete telephone line interface without the required external linefeed IC. Verify the exact linefeed topology, DC-feed and ring-generation components, protection network, and external BOM against the manufacturer’s reference schematic. Also confirm that a proposed ordering-code alternative has the same production configuration rather than assuming that a shared package suffix guarantees identical behavior.
Impormasyon ng Pagsunod sa Kautusan
The component listing identifies SI3226-E-FQ as RoHS compliant. The related SI3226-E-GQR listing is described as lead-free. No automotive qualification is indicated for this telecom interface device.