ITS4130QEPDXUMA1 vs TLE75004EPDXUMA1 Karşılaştırma
Ayrıntılı yan yana karşılaştırma ITS4130QEPDXUMA1 tarafından Infineon ve TLE75004EPDXUMA1 tarafından InfineonAnahtar özellikleri, elektriksel parametreleri, ambalajı, yaşam döngüsü durumu, fiyatlandırma ve mevcudiyeti karşılaştırarak tasarım gereksinimleriniz için en iyi bileşeni belirleyin.
Özellik Karşılaştırması
| Parametre | ITS4130QEPDXUMA1 | TLE75004EPDXUMA1 |
|---|---|---|
| Marka | Infineon | Infineon |
| Kategori | Power MOSFET Drivers | Power MOSFET Drivers |
| Yaşam Döngüsü Durumu | Aktif | Aktif |
| Ağ Yapısı | High-Side Power Switch (1:1) | — |
| Number of Channels | 4 (Quad) | 4 |
| On-State Resistance RDS(ON) | 130 mΩ (typ at Tj=25°C), 205 mΩ (typ at Tj=125°C) | — |
| Per-Channel Current | 650 mA (DC, per channel) | — |
| Load-Dump Tolerance | 45 V | — |
| Switch Type | N-Channel MOSFET | — |
| Paket | PG-TSDSO-14 (14-pin, exposed pad) | PG-TSDSO-14-41 (exposed pad) |
| Montaj Türü | Surface Mount | Surface Mount |
| İşletim Sıcaklığı | -40C to +125C (Tj) | — |
| Fault Protection | Over-current, Over-temperature, Over-voltage, Open-load detection | — |
| Diagnostic Output | Yes (status/feedback pin) | — |
| Reverse Polarity Protection | Achievable with external 150Ω GND resistor or GND diode+27Ω series resistor | — |
| Family | PROFET Industrial (ITS41xxQ-EP-D series) | — |
| Product Status | Active / Production | — |
| RoHS Durumu | Compliant | — |
| MSL Seviyesi | MSL3 (per Infineon package handling guidelines) | 2A |
| Product Type | — | Low-side power switch |
| On-State Resistance (Rdson) per Channel | — | [DATA_NEEDED: Rdson per channel] |
| Continuous Drain Current per Channel | — | 470 mA |
| Load Voltage (Vbb) | — | [DATA_NEEDED: Vbb max] |
| Çıkış Sayısı | — | 4 |
| Input Type | — | SPI (16-bit) + parallel input pins |
| SPI Clock Frequency | — | up to 5 MHz |
| İşletim Sıcaklığı Aralığı | — | -40 °C to +150 °C |
| Terminal Finish | — | Tin (Sn) |
| JEDEC / JESD-609 | — | e3 |
| Qualification | — | AEC-Q100 |
| Special Features | — | 3 V cranking, Limp Home (fail-safe) mode, open-load detection |