AD621BNZ Low-Power Instrumentation Amplifier | Analog Devices
MPN: AD621BNZ ✓ AktifAD621BNZ Genel Bakış
An instrumentation amplifier is a specialized amplifier category that converts a small differential signal into a single-ended or otherwise referenced output. Its internal topology provides differential input handling, high input impedance, and common-mode rejection while reducing the number of external precision resistors required. The AD621 uses internal resistor ratios for selectable gains of 10 and 100, with pin-strappable gain options and an output-reference connection for systems requiring an offset reference.
The AD621 is specified for low power and low drift, making it suitable for battery-powered instrumentation, industrial measurement systems, and sensor interfaces. Its operating supply range is listed from ±2.3 V to ±18 V, allowing operation from low-voltage bipolar rails as well as higher-voltage analog systems. The 800 kHz bandwidth provides useful signal bandwidth for pressure, temperature, strain, and other slowly varying sensor-front-end applications.
The instrument-amplifier architecture improves rejection of common-mode signals before they reach the output, while the internal gain-setting arrangement helps reduce board area and resistor-count requirements. The 8-pin PDIP format is useful for through-hole prototyping, laboratory instruments, and legacy industrial equipment where surface-mount assembly is unnecessary. The device is available in a single-amplifier configuration, allowing a compact analog signal chain.
Typical uses include bridge-amplifier interfaces, pressure and load-cell signal conditioning, biomedical instrumentation, industrial process monitoring, and low-level differential sensor measurement. The reference pin supports output shifting when a downstream converter or ADC requires a nonzero reference voltage. Designers should verify gain configuration, supply polarity, reference voltage, and output swing against the manufacturer datasheet before finalizing a board.
For a stable implementation, keep the differential input path short, provide adequate bypass capacitance close to the supply pins, and route the reference connection according to the datasheet’s reference-return guidance. Confirm output-voltage headroom for the selected gain and input common-mode range. This page combines the manufacturer product information, distributor availability information, comparison data, and practical design guidance to support component selection and PCB implementation.
Drop-in alternatifler için AD621BNZ — aynı paket, pin-başına uyumlu. PCB yeniden montajı gerektiren farklı paket bileşenleri dışlanmıştır.
Bu Serideki Variantlar
Yedek parça uyumlu olan aynı serideki modeller AD621BNZ (aynı form faktörü ve ayağa oturma) — farklı olan Bandwidth, Input Offset Voltage, Slew Rate.
AD621BN
✅ Yerleştirme📋 Katalogda Olmayan Referans Alternatifi
AD621AN
✅ Yerleştirme📋 Katalogda Olmayan Referans Alternatifi
AD621AR
✅ YerleştirmeFiyat için iletişime geçin
Veri Şablonunu Görüntüle →AD621SQ/883B
✅ Yerleştirme📋 Katalogda Olmayan Referans Alternatifi
AD620BNZ
✅ YerleştirmeFiyat için iletişime geçin
Veri Şablonunu Görüntüle →AD621BNZ Maksimum Değerlendirmeler & Elektriksel Özellikler
| Product Type | Instrumentation amplifier |
| Number of Amplifiers | 1 circuit |
| Supply Voltage Range | ±2.3 V to ±18 V |
| Paket | 8-pin PDIP |
| Input Offset Voltage | 125 µV typical |
| Bandwidth | 800 kHz typical |
| Slew Rate | 1.2 V/µs typical |
| Common-Mode Rejection Ratio | 120 dB to 130 dB, condition dependent |
| Gain | 10 or 100, pin-strappable |
| Çıkış Türü | Single-ended |
| Input Bias Current | 1 nA listed for AD621BNZ comparison |
| Operating Voltage | ±2.3 V to ±18 V |
| Internal Gain Setting | Internal resistor gain |
| ESD Protection | Yes |
| Montaj Türü | Through-hole |
| RoHS Durumu | unknown |
| REACH Status | unknown |
| AEC-Q100 Qualification | not_applicable |
AD621BNZ Pin Yapısı
| Pin 1 | RG — Gain-setting resistor connection |
| Pin 2 | -IN — Inverting differential input |
| Pin 3 | +IN — Non-inverting differential input |
| Pin 4 | V- — Negative supply connection |
| Pin 5 | REF — Output reference connection |
| Pin 6 | OUT — Single-ended amplifier output |
| Pin 7 | V+ — Positive supply connection |
| Pin 8 | RG — Gain-setting resistor connection |
Tipik Uygulamalar
AD621BNZ için uygundur 6 uygulamas: Load-Cell and Strain-Gauge Signal Conditioning, Industrial Pressure Sensor Interface, Battery-Powered Biomedical Sensor Interface, Bridge-Based Temperature Measurement, Precision Current-Shunt Measurement, Low-Level Differential Data Acquisition.
Load-Cell and Strain-Gauge Signal Conditioning
The AD621BNZ fits low-level differential strain-gauge and load-cell front ends because its 125 µV typical input offset limits signal error while the internally selectable gains of 10 and 100 support common transducer sensitivities. Its instrumentation-amplifier architecture rejects common-mode excitation voltage before amplification, reducing the number of matched precision resistors required around the input stage. The 800 kHz bandwidth is suitable for typical force, pressure, and weight signals that do not require kilohertz measurement bandwidth. Designers should confirm that the bridge excitation, input common-mode voltage, and output target remain inside the AD621 electrical limits, and should return the reference connection to a quiet analog ground when no output offset is required.
Önerilen
Industrial Pressure Sensor Interface
The AD621BNZ is appropriate for industrial pressure transmitters that produce a small differential voltage across a resistive bridge or sensor element. A typical input offset of 125 µV and gains of 10 or 100 preserve useful signal integrity before the signal reaches an ADC or transmitter driver, while the common-mode rejection helps isolate the sensor output from equipment-ground disturbances. The ±2.3 V to ±18 V supply range supports both compact low-voltage analog systems and higher-voltage bipolar instrumentation. Care is needed to maintain the bridge excitation return within the input common-mode range and to provide sufficient output-voltage headroom. Short input traces, local supply bypassing, and a controlled reference net help preserve accuracy in long industrial cable environments.
Önerilen
Battery-Powered Biomedical Sensor Interface
The AD621BNZ supports low-voltage biomedical and wearable sensor interfaces because Analog Devices describes the AD621 as a low-power, low-cost instrumentation amplifier and specifies operation from ±2.3 V to ±18 V. Selectable gains of 10 and 100 can amplify small differential electrode or resistive-sensor outputs without requiring a large external resistor network. The 125 µV typical offset is important when the useful sensor signal is only millivolts, while common-mode rejection helps reject signals shared by both inputs. The design must still account for patient-signal safety, input protection, electrode biasing, and isolation requirements; the amplifier itself does not provide those protections. Confirm supply current, noise density, and common-mode behavior in the manufacturer datasheet for the intended operating condition.
Önerilen
Bridge-Based Temperature Measurement
The AD621BNZ can condition the small differential output of a resistive temperature bridge where millivolt-level changes must be amplified without adding excessive offset or gain error. The internal gains of 10 and 100 simplify initial bring-up, while 800 kHz bandwidth comfortably accommodates slow thermal signals and the switching ripple filtering commonly placed ahead of the amplifier. Its low-drift, low-power positioning supports portable or multi-channel thermal monitoring systems. Use a quiet reference return and place input and bypass components close to the device to minimize thermoelectric and pickup effects. The engineer should also verify output swing, allowable input common-mode voltage, and whether the downstream ADC requires a unipolar or bipolar input range.
Önerilen
Precision Current-Shunt Measurement
The AD621BNZ is useful for measuring small voltage drops across a shunt when the source is floating or shares ground noise with an ADC. The differential input architecture reduces common-mode error, and selectable gains of 10 or 100 allow the shunt voltage to be scaled efficiently for conversion. Its 125 µV typical input offset sets an important sensitivity limit for very small shunt drops. Layout should use a Kelvin connection to the shunt so input current does not create voltage errors in the routing copper. The common-mode voltage at the shunt must remain within the input range, and the output must maintain sufficient swing around the selected reference voltage. For faster transients, verify the actual signal bandwidth and output settling against the 800 kHz device bandwidth.
Önerilen
Low-Level Differential Data Acquisition
The AD621BNZ fits laboratory and industrial data-acquisition modules that must amplify a low-level differential sensor signal before an ADC. Its single-ended output can connect to a unipolar converter through an appropriate reference bias, while 800 kHz bandwidth provides margin for many general-purpose sensor channels. The low typical input offset of 125 µV and common-mode rejection listed up to 130 dB help improve conversion accuracy when the source is noisy or unbalanced. Designers should select a reference voltage with low noise, bypass each supply rail locally, and avoid routing the differential pair through switching-converter regions. If the source impedance is high, account for bias-current effects and input settling in the system timing budget.
Önerilen
Önerilen Ürünler Özeti
Mühendislik referans verileri: AD621BNZ — karşılaştırma, tasarım rehberi ve uyumluluk bilgileri.
Seçim Kılavuzu
Alternatiflerle Karşılaştırma
| Parametre | Bu Ürün | AD621BN | AD621AN | AD621AR | AD621SQ/883B | AD620BNZ |
|---|---|---|---|---|---|---|
| Package | PDIP-8 | PDIP-8 | PDIP-8 | PDIP-8 | PDIP-8 | PDIP-8 |
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Product Type | Instrumentation amplifier | Instrumentation amplifier | Instrumentation amplifier | Instrumentation amplifier | Instrumentation amplifier | Instrumentation amplifier |
| Number of Amplifiers | 1 circuit | 1 circuit | 1 circuit | 1 circuit | 1 circuit | 1 circuit |
| Gain Configuration | Internally selectable gains of 10 and 100 | Internally selectable gains of 10 and 100 | Internally selectable gains of 10 and 100 | Internally selectable gains of 10 and 100 | Internally selectable gains of 10 and 100 | External resistor gain setting |
| Output Type | Single-ended | Single-ended | Single-ended | Single-ended | Single-ended | Single-ended |
Ana Farklılayıcılar
- Internally selectable gain options simplify the feedback network (karşılaştırma:AD620BNZ)
- Lower input bias current than the cited AD621AR comparison (karşılaştırma:AD621AR)
- Higher listed CMRR in the qualified AD621 family comparison (karşılaştırma:AD621SQ/883B)
Tasarım Notları
Route the two differential inputs as a compact pair and keep them away from switching-converter inductors, relay contacts, and high-current return paths. Place the input-side components at the source connector and use a continuous ground reference beneath the pair where practical. The 125 µV typical input offset means that copper thermoelectric effects and leakage can become relevant in precision measurements, particularly across large temperature changes.
Place the supply bypass capacitor directly between the V+ and V- pins and connect its return to the device ground reference with minimal loop area. The AD621BNZ supports ±2.3 V to ±18 V, but the usable signal range depends on the selected supply, common-mode input voltage, gain, and output swing. Do not choose the supply from the maximum rating alone; check the manufacturer operating characteristic curves for the actual gain and load condition.
Do not treat AD620BNZ as an automatic substitute for AD621BNZ. The AD621 provides internally selectable gains of 10 and 100, whereas the AD620 family normally uses an external gain-setting resistor. Confirm the gain pins, reference connection, supply limits, and output range against the exact manufacturer pin table before revising a PCB or replacing the device in an existing design.
For shunt and high-impedance sensor measurements, use Kelvin routing and avoid sharing narrow input traces with guard or reference currents. Bias-current error and input-capacitance settling can matter even when the 800 kHz bandwidth appears sufficient. Add input protection only after checking its leakage, capacitance, and effect on source impedance. Keep the reference node quiet and determine whether it should connect to analog ground or a low-impedance bias source.
Uyumluluk Bilgisi
The AD621 family is for general-purpose instrumentation-amplifier applications. RoHS, REACH, lead-free, halogen-free, and conflict-minerals status require confirmation for the exact orderable suffix.