INA131BPG4 - G=100 Instrumentation Amplifier | Texas Instruments
MPN: INA131BPG4 ✓ AktifINA131BPG4 Genel Bakış
An instrumentation amplifier is a specialized analog signal-conditioning IC designed to amplify the small differential voltage produced by sensors and measurement bridges. In the signal-chain hierarchy, it belongs to the amplifier IC family and supports precision measurement systems that require high input impedance, accurate differential sensing, and stable gain without complex external resistor networks. The INA131 integrates the gain-setting and differential-input functions into one device.
Key characteristics include the fixed gain of 100, a 50 µV input offset voltage, 70 kHz bandwidth, and a single-ended output stage. The fixed-gain architecture simplifies circuit design by eliminating the external gain-setting resistor normally required with general-purpose instrumentation amplifiers. The 8-pin PDIP package also supports conventional through-hole assembly and prototype-board layouts.
The three-op-amp architecture provides differential input handling and a stable internal gain arrangement. Its specified supply range of 2.25 V to 18 V permits operation from a single 2.25 V rail through higher single-supply levels, while the ±18 V capability covers dual-supply instrumentation systems. Because the bandwidth is specified at the fixed gain of 100, the device is most appropriate for sensor signals that do not require high closed-loop bandwidth.
Typical uses include resistive bridge excitation, pressure-sensor interfaces, strain-gauge amplification, industrial current measurement, and laboratory instrumentation. In a bridge circuit, the small differential output of the sensor is amplified by a factor of 100 before conversion by an ADC. In a shunt-measurement system, the INA131 provides differential sensing while rejecting common-mode voltage present across the shunt.
Designers should verify the complete input common-mode range, output swing, input bias current, supply-current behavior, and settling requirements at the intended operating voltage before finalizing the analog front end. Input filtering and source impedance must also be evaluated against the device's published AC and DC accuracy characteristics.
This product page combines the verified ordering information, package details, electrical highlights, drop-in family alternatives, and practical application guidance for engineers evaluating the INA131BPG4 in precision measurement designs.
Drop-in alternatifler için INA131BPG4 — aynı paket, pin-başına uyumlu. PCB yeniden montajı gerektiren farklı paket bileşenleri dışlanmıştır.
Bu Serideki Variantlar
Yedek parça uyumlu olan aynı serideki modeller INA131BPG4 (aynı form faktörü ve ayağa oturma) — farklı olan Supply Voltage Range, Amplifier Type, Input Offset Voltage.
INA131BP
✅ YerleştirmeFiyat için iletişime geçin
Veri Şablonunu Görüntüle →INA131APG4
✅ Yerleştirme📋 Katalogda Olmayan Referans Alternatifi
INA131BPG4 Maksimum Değerlendirmeler & Elektriksel Özellikler
| Product Type | Precision instrumentation amplifier |
| Fixed Gain | 100 V/V |
| Internal Amplifier Count | 3 amplifiers |
| Circuit Count | 1 circuit |
| Çıkış Türü | Single-ended |
| Input Offset Voltage | 50 µV |
| Bandwidth | 70 kHz |
| Supply Voltage Range | 2.25 V to 18 V |
| Maximum Supply Voltage | ±18 V or 36 V total |
| Paket | 8-pin PDIP |
| Package Width | 0.300 in (7.62 mm) |
| Montaj Türü | Through-hole |
| Delivery Package | Tube |
INA131BPG4 tube Pin Yapısı Kılavuzu
INA131BPG4 (tube paket) için pin yapısı. Bu analog bileşen, giriş, çıkış ve güç besleme pinleri içerir. Ofset null, telafi ve etkinleştirme pin yapılandırmaları için üretici veri kitapçığını referans alın. Sinyal işleme ve güç amplifikasyon devreleri için mükemmel bir bileşendir.
Ayrıntılı pin çıkış verisi mevcut değil: INA131BPG4.
Aşağıdaki veri sayfası tam pin konfigürasyonu için.
Tipik Uygulamalar
INA131BPG4 için uygundur 6 uygulamas: Resistive Bridge Sensor Interface, Pressure Transducer Conditioning, Precision Current Shunt Measurement, Strain Gauge Amplification, Laboratory Instrumentation Signal Chain, Industrial Process Measurement.
Resistive Bridge Sensor Interface
INA131BPG4 fits resistive bridge sensor front ends because its fixed gain of 100 amplifies the bridge differential output while the three-op-amp architecture handles the measurement signal path. The 50 µV input offset voltage is useful when the sensed quantity produces a small millivolt-level imbalance. Place the amplifier close to the bridge, maintain symmetry between input routing paths, and verify that bridge excitation and common-mode voltage stay within the input limits. Its 70 kHz bandwidth is appropriate for many temperature, pressure, and position bridges that do not require high-frequency dynamic response.
Önerilen
Pressure Transducer Conditioning
The INA131BPG4 can condition the differential output of a resistive pressure transducer because the fixed 100:1 gain reduces the required ADC input range without external gain-setting resistors. Its single-ended output simplifies connection to a unipolar converter input, while the 50 µV offset specification supports measurements where bridge imbalance is small. Designers should calculate the maximum output swing across the full sensor and excitation range, keep the bridge return path close to the amplifier ground, and include filtering only where its interaction with the 70 kHz bandwidth remains acceptable.
Önerilen
Precision Current Shunt Measurement
INA131BPG4 is applicable to high-side or low-side current-shunt monitoring when the shunt voltage remains inside the amplifier's input range. Its differential input architecture supports rejection of common-mode voltage across the shunt, and the fixed gain of 100 increases millivolt-scale current signals to a more useful analog level. Route the Kelvin sense connections symmetrically and avoid sharing copper with high-current paths, because parasitic resistance can create measurement error. The 70 kHz bandwidth accommodates many power-monitoring loops while remaining unsuitable for very fast current transients.
Önerilen
Strain Gauge Amplification
The INA131BPG4 supports strain-gauge conditioning where mechanical deformation creates a small differential bridge signal. A gain of 100 increases the sensor output before digitization, and the instrumentation-amplifier topology reduces sensitivity to common-mode excitation voltage relative to a simple difference amplifier. For best results, use the bridge's dedicated sense returns, keep input traces short, and establish the system noise and offset budget before adding gain stages. Confirm the 50 µV input offset specification against the minimum strain event that the design must resolve.
Önerilen
Laboratory Instrumentation Signal Chain
INA131BPG4 is useful in laboratory measurement equipment that accepts differential sensor outputs and requires a predictable fixed gain. The 2.25 V to 18 V supply range supports single-supply designs, and the 8-pin PDIP package simplifies retrofitting into educational or prototype instruments. The 70 kHz bandwidth covers many temperature, level, and force measurements but not precision waveform analysis. Establish grounding and shielding to prevent sensor leads from injecting errors, and verify output headroom when selecting the bridge excitation and input scale.
Önerilen
Industrial Process Measurement
INA131BPG4 can serve as the analog front end for industrial process sensors when the controller requires a single-ended signal derived from a differential sensor. Its fixed gain of 100 reduces circuit complexity, while the 50 µV offset and 70 kHz bandwidth provide useful baseline characteristics for slow process variables such as pressure, strain, or tank level. The through-hole PDIP package is practical for serviceable control boards. Field designs should include surge protection, input filtering, and proper grounding while confirming that every parameter remains within the limits of the selected INA131 suffix.
Önerilen
Önerilen Ürünler Özeti
Mühendislik referans verileri: INA131BPG4 — karşılaştırma, tasarım rehberi ve uyumluluk bilgileri.
Seçim Kılavuzu
Alternatiflerle Karşılaştırma
| Parametre | Bu Ürün | INA131BP | INA131APG4 |
|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments |
| Package | 8-pin PDIP | 8-pin PDIP | 8-pin PDIP |
| Product Type | Precision instrumentation amplifier | Instrumentation amplifier | INA131 family instrumentation amplifier |
Ana Farklılayıcılar
- Fixed gain simplifies the analog front end (karşılaştırma:INA131BP)
- Clear single-ended output integration (karşılaştırma:INA131APG4)
- Single-supply flexibility (karşılaştırma:INA131BP)
Tasarım Notları
Route the two differential inputs as a balanced pair and connect the sensor or bridge return directly to the amplifier reference ground. Keep input traces short and away from switching nodes, relay contacts, and high-current paths. The INA131BPG4 has a fixed gain of 100, so input-routing errors cannot be corrected by reducing the gain. For a bridge circuit, use the sensor's dedicated sense or return conductors instead of sharing copper carrying excitation current.
Treat the 70 kHz bandwidth as the upper limit for useful closed-loop response at the fixed gain of 100. Place any anti-alias or sensor-noise filter close to the amplifier input and calculate its corner frequency with the source impedance included. Excessively low cutoff frequencies can slow the measurement path or interact with sensor capacitance, while insufficient filtering can allow out-of-band noise to reach the ADC.
Verify output-voltage headroom over the complete input range before fixing the sensor excitation voltage. A single-ended output requires adequate voltage range to remain linear at both maximum positive signal and maximum negative signal. The stated 2.25 V to 18 V operating range does not by itself guarantee full output swing, so consult the manufacturer output-swing and common-mode conditions for the selected supply voltage.
Do not select a replacement from package appearance alone. Before using INA131BP or INA131APG4, compare the ordering suffix, pin functions, gain accuracy, input offset, bandwidth, supply limits, operating-temperature grade, and lifecycle status. A same-package designation can conceal a temperature-grade or marking difference that matters in industrial production.
Uyumluluk Bilgisi
The available manufacturer and distributor information does not explicitly state RoHS, REACH, lead-free, halogen-free, or conflict-minerals status. The device is not presented as an automotive-qualified AEC-Q100 part.