LTC1350CG - 120 kbaud RS-562 Transceiver | Analog Devices
MPN: LTC1350CG ✓ AktifLTC1350CG Genel Bakış
An RS-562 transceiver is a bidirectional interface IC that combines differential line-driver and line-receiver functions in one package. In the broader semiconductor hierarchy, it belongs to the interface-IC family, where transceivers sit between digital logic and physical communication lines. Unlike single-ended RS-232 equipment, RS-562 is designed for balanced, point-to-point connections and reduced ground-reference sensitivity. The LTC1350CG therefore serves as the physical-layer interface between a data-processing system and a balanced cable.
The three drivers support independent transmit channels, while the five receivers provide five receive channels. Its maximum operating data rate of 120 kbaud makes it appropriate for moderate-speed control, instrumentation, and industrial data links rather than high-speed Ethernet or video transmission. Operation from a 3.3 V supply also allows it to interface with modern 3.3 V logic systems. Commercial-grade temperature classification makes the CG suffix relevant for room-temperature industrial and commercial equipment.
The receiver architecture provides the physical-layer interface needed for balanced data transfer, while the multiple driver and receiver channels reduce the number of separate interface packages required in multi-channel equipment. Designers should account for the specified 1000 pF and 3 kΩ load condition when evaluating cable length, termination, topology, and data rate. Balanced routing on the printed circuit board is also important for preserving the noise-rejection benefit associated with differential signaling.
Typical applications include industrial control links, test and measurement systems, point-to-point data acquisition, embedded equipment interfaces, and instrumentation networks operating at up to 120 kbaud. The device can also support point-to-point links between a host controller and a remote peripheral when both ends use compatible balanced signaling and termination.
Design the power and signal paths carefully. Place the transceiver close to the connector, route driver and receiver traces as a balanced pair, observe the ground reference at the interface boundary, and validate the completed cable and load configuration against the EIA/TIA-562 requirements. A 1000 pF load is a meaningful capacitive budget, so cable length and receiver loading can materially affect usable communication distance.
This product page combines the manufacturer’s operating limits with practical interface guidance, package information, sourcing context, and verified ordering references. It helps engineers distinguish the LTC1350CG from suffix and ordering variants while focusing on the parameters that determine board-level compatibility: 3.3 V operation, 120 kbaud performance, balanced RS-562 signaling, 3.5 V low-power operation, and the 28-terminal SSOP footprint.
Drop-in alternatifler için LTC1350CG — aynı paket, pin-başına uyumlu. PCB yeniden montajı gerektiren farklı paket bileşenleri dışlanmıştır.
LTC1350IG
✅ Yerleştirme📋 Katalogda Olmayan Referans Alternatifi
LTC1350CG Özellikler
| Product Type | RS-562 line transceiver |
| Driver Count | 3 drivers |
| Receiver Count | 5 receivers |
| Maximum Data Rate | 120 kbaud |
| Besleme Gerilimi | 3.3 V |
| Specified Load | 1000 pF with 3 kΩ |
| Compliance | EIA/TIA-562 data-rate and overvoltage specifications |
| Temperature Grade | Commercial |
| Paket | 28-terminal SSOP |
| Lead Form | Gull wing |
| Package Shape | Rectangular |
| Montaj Türü | Surface mount |
| Transceiver Configuration | 3-driver, 5-receiver |
| Signal Type | Balanced differential line signaling |
LTC1350CG rectangular Pin Yapısı Kılavuzu
LTC1350CG (rectangular paket) için pin yapısı. Pin numaralandırma, işlevleri ve bağlantı şemaları üretici veri kitapçığında tanımlanmıştır. Doğru ayak ve soldurma kılavuzları için onu referans alın.
Ayrıntılı pin çıkış verisi mevcut değil: LTC1350CG.
Aşağıdaki veri sayfası tam pin konfigürasyonu için.
Tipik Uygulamalar
LTC1350CG için uygundur 6 uygulamas: Industrial Control Point-to-Point Links, Test and Measurement Data Acquisition, Embedded Equipment Communication, Instrumentation Networking, Remote Sensor Interface, Communication Port for Industrial Equipment.
Industrial Control Point-to-Point Links
The Analog Devices LTC1350CG fits balanced point-to-point control links that operate at up to 120 kbaud on a 3.3 V system supply. Its three drivers and five receivers can serve several communication channels without requiring separate single-direction interface packages. According to the manufacturer product page, the device supports a 1000 pF load through a 3 kΩ network, so cable length, connector capacitance, and termination must remain within the channel design. Use the driver outputs toward remote equipment and receiver inputs toward the controller, while keeping each balanced pair closely routed and symmetrically terminated.
Önerilen
Test and Measurement Data Acquisition
The LTC1350CG is appropriate for moderate-rate data-acquisition and laboratory interface systems that require balanced signaling from a 3.3 V logic environment. Its 120 kbaud operating limit is ample for supervisory commands, status information, and low-bandwidth measurement data, while three transmitters and five receivers support multiple point-to-point links. According to the Analog Devices manufacturer product page, compliance with EIA/TIA-562 requirements supports standardized interface behavior. Keep sensitive analog and reference circuitry away from cable-entry points, and route the transceiver side of each balanced connection away from high-current switching nodes.
Önerilen
Embedded Equipment Communication
The LTC1350CG can connect an embedded controller to remote instrumentation over balanced copper links when the required baud rate does not exceed 120 kbaud. Operation from a 3.3 V supply simplifies integration with modern controller logic, while the five receivers allow multiple peripheral responses to be monitored. According to the Analog Devices manufacturer product page, the transceiver is designed around EIA/TIA-562 interface behavior and a specified 1000 pF, 3 kΩ load condition. Provide local decoupling near the supply pins and use a consistent ground-reference strategy at each cable endpoint to prevent interface stress.
Önerilen
Instrumentation Networking
The three-driver, five-receiver arrangement of the LTC1350CG supports instrumentation networks composed of several point-to-point differential links. The 120 kbaud capability suits supervisory channels, equipment interlocks, and configuration traffic rather than bulk file transfer. According to the Analog Devices manufacturer product page, the transceiver operates from 3.3 V and is compliant with applicable EIA/TIA-562 data-rate and overvoltage specifications. Maintain the specified load budget through controlled cable lengths, proper connector selection, and balanced PCB routing, particularly when several cables leave the same instrument enclosure.
Önerilen
Remote Sensor Interface
The LTC1350CG can provide a balanced physical interface between a local controller and a remote sensor assembly when the data rate is 120 kbaud or lower. Balanced signaling is useful in industrial environments where cable-borne noise and ground-potential differences can affect single-ended links. According to the Analog Devices manufacturer product page, the transceiver supports a 1000 pF load with a 3 kΩ network. Keep the cable route away from motors and switching equipment, place the interface near the connector, and confirm that the sensor cable and termination do not exceed the allowed capacitive load.
Önerilen
Communication Port for Industrial Equipment
The LTC1350CG is suitable for adding a standardized balanced communication port to industrial equipment with a 3.3 V control system. The three transmitter channels can support connections to multiple peripheral nodes, while the five receiver channels provide additional incoming data paths. According to the Analog Devices manufacturer product page, the device is designed to meet EIA/TIA-562 specifications and operate at up to 120 kbaud. Designers should separate the interface from noisy power stages, use approved balanced cables and connectors, and verify grounding and surge-protection arrangements at the external port.
Önerilen
Önerilen Ürünler Özeti
Mühendislik referans verileri: LTC1350CG — karşılaştırma, tasarım rehberi ve uyumluluk bilgileri.
Seçim Kılavuzu
Alternatiflerle Karşılaştırma
| Parametre | Bu Ürün |
|---|---|
| Package | 28-terminal SSOP |
| Brand | Analog Devices |
| Product Type | RS-562 line transceiver |
| Driver Count | 3 drivers |
| Receiver Count | 5 receivers |
| Maximum Data Rate | 120 kbaud |
| Nominal Supply Voltage | 3.3 V |
| Specified Load | 1000 pF with 3 kΩ |
| Temperature Grade | Commercial |
| Interface Compliance | EIA/TIA-562 data-rate and overvoltage specifications |
Ana Farklılayıcılar
- Combines multiple physical-layer channels in one interface IC (karşılaştırma:Single-direction RS-562 transceiver packages)
- Supports modern 3.3 V control systems (karşılaştırma:Higher-voltage RS-562 interface implementations)
- Provides a defined moderate-speed channel limit (karşılaştırma:High-speed serial-interface transceivers)
Tasarım Notları
Route every LTC1350CG balanced signal as a closely coupled differential pair, with the two conductors maintained at approximately equal impedance through connectors and test points. Keep the interface section physically separate from switching-power nodes and high-current relay or motor paths. The manufacturer specifies operation with a 1000 pF load through a 3 kΩ network, so PCB escape traces, connector capacitance, and cable capacitance all contribute to the channel budget.
Do not assume that the 120 kbaud rating alone guarantees a usable cable distance. The LTC1350CG is intended for balanced RS-562 links with a controlled 1000 pF, 3 kΩ load condition. Verify the complete cable, connector, receiver, and termination configuration at the intended rate. Incorrect impedance, excessive stubs, or poorly controlled ground references can reduce margin even when the nominal baud rate is below the device maximum.
Place the LTC1350CG close to the external interface connector and provide short, symmetric paths from the device to protection components and the board edge. Keep supply and ground connections compact, use suitable bypassing close to the device pins, and avoid sharing high-current return paths with sensitive balanced signals. These practices reduce radiated coupling and help preserve differential signal integrity in industrial environments.
Uyumluluk Bilgisi
The manufacturer product-page excerpt does not state RoHS, REACH, lead-free, halogen-free, or conflict-minerals status. AEC-Q100 is not applicable because the listed device is commercial grade rather than an automotive-qualified variant.