MAX3232ECPWR - Dual RS-232 Transceiver | Texas Instruments (Tape & Reel)
MPN: MAX3232ECPWR ✓ AktifMAX3232ECPWR Genel Bakış
An RS-232 transceiver is an interface IC that converts logic-level signals from a processor or controller into RS-232 voltage levels, while converting received RS-232 signals back into logic-compatible levels. Within the hierarchy of interface ICs, serial transceivers connect digital controllers to communication ports using the TIA/EIA-232-F electrical standard. The MAX3232ECPWR uses an on-chip charge pump to generate positive and negative RS-232 voltages from one low-voltage supply.
The device accepts supply voltages from 3 V to 5.5 V and operates at data-signaling rates up to 250 kbit/s. Its two transmitters and two receivers support full-duplex serial links, while driver output slew rate is limited to 30 V/µs. Pin-to-pin ESD protection rated at ±15 kV improves system robustness when cables are connected or disconnected.
The MAX3232ECPWR is the commercial-temperature version of the MAX3232E family, specified for 0 °C to 70 °C. It is packaged in a 16-pin gull-wing TSSOP with a 4.4 mm lead pitch. Four external charge-pump capacitors are required, allowing the interface to operate from a single 3 V or 5 V rail without a separate negative power supply.
Typical uses include industrial serial adapters, data-acquisition equipment, point-of-sale terminals, laboratory instruments, and service-console links. The device is appropriate when a controller needs an RS-232 port but cannot generate the positive and negative voltages required by legacy RS-232 drivers directly.
Place the four charge-pump capacitors close to their associated pins and keep the exposed supply and ground paths short. Keep the RS-232 connector interface physically separated from sensitive analog or high-speed digital routing, and provide appropriate board-level protection when exposed cables exceed the device's rated ESD withstand.
This product page combines electrical specifications, package and pin information, drop-in replacement analysis, application guidance, and design notes for engineers evaluating the MAX3232ECPWR in 3 V and 5 V RS-232 interfaces.
Drop-in alternatifler için MAX3232ECPWR — aynı paket, pin-başına uyumlu. PCB yeniden montajı gerektiren farklı paket bileşenleri dışlanmıştır.
Bu Serideki Variantlar
Yedek parça uyumlu olan aynı serideki modeller MAX3232ECPWR (aynı form faktörü ve ayağa oturma) — farklı olan Product Type, Package, Supply Voltage Range, Channel Configuration, ESD Protection.
MAX3232CPWR
✅ Yerleştirme ⚠️ Onaylanmamış ÖzelliklerFiyat için iletişime geçin
Veri Şablonunu Görüntüle →MAX3232IPW
✅ Yerleştirme ⚠️ Onaylanmamış ÖzelliklerFiyat için iletişime geçin
Veri Şablonunu Görüntüle →MAX3232EWP
✅ Yerleştirme ⚠️ Onaylanmamış Özellikler📋 Katalogda Olmayan Referans Alternatifi
MAX3232EA
✅ Yerleştirme ⚠️ Onaylanmamış Özellikler📋 Katalogda Olmayan Referans Alternatifi
ST3232CTR
✅ Yerleştirme📋 Katalogda Olmayan Referans Alternatifi
MAX3232ECPWR Özellikler
| Product Type | Dual RS-232 line transceiver |
| Supply Voltage Range | 3 V to 5.5 V |
| Number of Line Drivers | 2 channels |
| Number of Line Receivers | 2 channels |
| Maximum Data Signaling Rate | 250 kbit/s |
| Maximum Driver Output Slew Rate | 30 V/µs |
| IEC ESD Protection | ±15 kV |
| RS-232 Compliance | TIA/EIA-232-F |
| Charge Pump | Dual charge-pump circuit |
| External Charge-Pump Capacitors | 4 capacitors |
| İşletim Sıcaklığı Aralığı | 0 °C to 70 °C |
| Temperature Grade | Commercial |
| Paket | 16-pin TSSOP |
| Lead Pitch | 4.4 mm |
| Pin Sayısı | 16 pins |
| Terminal Form | Gull wing |
| Package Shape | Rectangular |
MAX3232ECPWR Pin Yapısı
| Pin 1 | R1IN — Receiver 1 input |
| Pin 2 | R1OUT — Receiver 1 output |
| Pin 3 | R2IN — Receiver 2 input |
| Pin 4 | R2OUT — Receiver 2 output |
| Pin 5 | GND — Ground connection |
| Pin 6 | V+ — Positive charge-pump output |
| Pin 7 | C2+ — Charge-pump capacitor 2 positive terminal |
| Pin 8 | C1+ — Charge-pump capacitor 1 positive terminal |
| Pin 9 | C1- — Charge-pump capacitor 1 negative terminal |
| Pin 10 | C2- — Charge-pump capacitor 2 negative terminal |
| Pin 11 | V- — Negative charge-pump output |
| Pin 12 | T1IN — Transmitter 1 logic input |
| Pin 13 | T2IN — Transmitter 2 logic input |
| Pin 14 | T1OUT — Transmitter 1 RS-232 output |
| Pin 15 | T2OUT — Transmitter 2 RS-232 output |
| Pin 16 | VCC — Device supply input |
Tipik Uygulamalar
MAX3232ECPWR için uygundur 6 uygulamas: Industrial Serial Port Interface, Point-of-Sale Terminal, Data Acquisition Equipment, Laboratory Instrument Console, Service and Configuration Port, Embedded System Serial Adapter.
Industrial Serial Port Interface
The MAX3232ECPWR is suitable for industrial controllers that require a legacy RS-232 port but operate from a 3.3 V or 5 V logic rail. Its dual charge-pump circuit generates the positive and negative voltages needed by the RS-232 interface from one 3 V to 5.5 V supply, avoiding a separate negative rail. The two transmitters and two receivers support full-duplex communication at rates up to 250 kbit/s. The ±15 kV IEC ESD protection is valuable when the connector is accessible to service personnel or connected equipment. Place the four charge-pump capacitors close to pins 7 through 10 and route the exposed connector interface away from sensitive circuitry.
Önerilen
Point-of-Sale Terminal
Point-of-sale equipment can use the MAX3232ECPWR to connect a controller to a receipt printer, scanner, or service terminal through RS-232. The 250 kbit/s maximum signaling rate covers common serial-port traffic while the controlled 30 V/µs driver slew rate supports compliant RS-232 transitions. Operation from a single 3 V to 5.5 V rail simplifies system power design, and the integrated charge pump removes the need for a discrete negative supply generator. Because peripherals may be connected by user-accessible cables, the ±15 kV IEC ESD protection improves connector-side robustness. Maintain a low-impedance ground path between the transceiver and connector and consider additional surge protection for installations exposed to severe transients.
Önerilen
Data Acquisition Equipment
The MAX3232ECPWR provides a compact interface between a data-acquisition controller and an RS-232-compatible instrument. Its 250 kbit/s capability is appropriate for configuration commands, measurement results, and status reporting in many laboratory and industrial systems. The 16-pin TSSOP package preserves board area while the single 3 V to 5.5 V supply operation simplifies rail planning around modern processors and FPGAs. The ±15 kV IEC ESD rating helps protect the interface when instrument cables are routinely reconnected. Keep the four external charge-pump capacitors near the IC and provide a quiet ground connection, because cable transients and ground potential differences can otherwise affect communication reliability.
Önerilen
Laboratory Instrument Console
MAX3232ECPWR can serve as the host-side RS-232 interface in laboratory instruments that retain legacy serial consoles. A computer or embedded controller communicates through the two receiver channels, while the two driver channels support bidirectional command and data transfer. The device's 250 kbit/s maximum data rate is suitable for terminal sessions, configuration files, and instrument status messages. Running from a 3 V to 5.5 V supply permits use with both legacy 5 V controllers and modern 3.3 V systems. The integrated charge pump requires only four external capacitors and no separate negative supply, reducing board complexity. The commercial 0 °C to 70 °C rating should be checked against the instrument's internal temperature environment.
Önerilen
Service and Configuration Port
The MAX3232ECPWR is well suited to equipment that retains a service or configuration connector for diagnostics, firmware loading, and parameter adjustment. Its bidirectional 250 kbit/s interface supports both command transmission and status reception. The ±15 kV IEC ESD protection is particularly relevant to service ports because technicians frequently connect and disconnect cables. A single 3 V to 5.5 V supply allows the transceiver to operate directly alongside embedded processors without an additional negative-voltage rail. Designers should keep the RS-232 trace away from clocks, ADC inputs, and switching-converter power nodes, and should verify that the external connector does not introduce ground offsets beyond the device interface tolerances.
Önerilen
Embedded System Serial Adapter
An embedded controller can use the MAX3232ECPWR to add a conventional RS-232 port to a system built around a 3.3 V processor. The device converts logic-level transmit inputs into RS-232 levels and converts received signals back to logic-compatible outputs, while the internal charge pump supplies the required positive and negative voltages. Its 16-pin TSSOP footprint supports compact single-board designs, and 250 kbit/s operation covers legacy printer, modem, and instrument-control links. Four charge-pump capacitors are required for operation. Place them close to the associated pins, minimize loop area around the charge-pump nodes, and preserve an uninterrupted ground connection between the IC, connector shield, and chassis or enclosure grounding strategy.
Önerilen
Önerilen Ürünler Özeti
Mühendislik referans verileri: MAX3232ECPWR — karşılaştırma, tasarım rehberi ve uyumluluk bilgileri.
Seçim Kılavuzu
Alternatiflerle Karşılaştırma
| Parametre | Bu Ürün | MAX3232CPW | MAX3232IPW | MAX3232EWP | MAX3232EA | ST3232CTR |
|---|---|---|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | STMicroelectronics |
| Package | 16-TSSOP | 16-TSSOP | 16-TSSOP | 16-TSSOP | 16-TSSOP | 16-TSSOP |
| Product Type | Dual RS-232 transceiver | Dual RS-232 transceiver | Dual RS-232 transceiver | Dual RS-232 transceiver | Dual RS-232 transceiver | Dual RS-232 transceiver |
| Supply Voltage Range | 3 V to 5.5 V | 3 V to 5.5 V | 3 V to 5.5 V | 3 V to 5.5 V | 3 V to 5.5 V | 3 V to 5.5 V |
| Maximum Data Rate | 250 kbit/s | 250 kbit/s | 250 kbit/s | 250 kbit/s | 250 kbit/s | 250 kbit/s |
| Line Drivers | 2 channels | 2 channels | 2 channels | 2 channels | 2 channels | 2 channels |
| Line Receivers | 2 channels | 2 channels | 2 channels | 2 channels | 2 channels | 2 channels |
| External Charge-Pump Capacitors | 4 capacitors | 4 capacitors | 4 capacitors | 4 capacitors | 4 capacitors | 4 capacitors |
Ana Farklılayıcılar
- Enhanced connector-side ESD protection (karşılaştırma:MAX3232CPW)
- Commercial-temperature option supports cost-sensitive room-temperature equipment (karşılaştırma:MAX3232IPW)
- Single-supply operation simplifies embedded interfaces (karşılaştırma:MC1488NE4)
- Pin-compatible second-source option (karşılaştırma:ST3232CTR)
Tasarım Notları
Place the four charge-pump capacitors close to pins 7 through 10 using short traces and a compact ground connection. These nodes switch at high frequency, so excessive loop area can increase radiated emissions and coupling into nearby analog circuitry. Follow the capacitor values and topology shown in the Texas Instruments datasheet. Keep the RS-232-side routing away from clocks, ADC inputs, switching-regulator power nodes, and sensitive sensor signals.
Do not treat the MAX3232ECPWR as a 5 V-only RS-232 circuit. Its specified single-supply operating range is 3 V to 5.5 V, and the charge-pump capacitor requirements can vary with supply conditions. Use the manufacturer-recommended capacitor values and ensure that transmitter input levels remain compatible with the VCC rail. Also distinguish logic-side pins 12 and 13 from RS-232-side outputs 14 and 15 during schematic review.
The 30 V/µs maximum transmitter slew rate controls RS-232 edge speed, but cable and board radiation can still be significant. Route T1OUT and T2OUT as short, impedance-controlled paths to the connector, maintain a continuous ground reference beneath the pair, and avoid adding unnecessary stubs. For enclosure-mounted connectors, evaluate whether additional board-level TVS or surge protection is required rather than assuming the device's ±15 kV IEC ESD rating covers every external fault condition.
RS-232 is a single-ended, unbalanced interface, and ground potential differences can cause communication errors. Connect the transceiver ground to the connector ground with a low-impedance path and evaluate whether a chassis or signal-ground connection is required for long cable runs. Do not use the charge-pump V+ and V- pins as general supply rails; they are generated specifically for the line drivers and should not power external circuitry.
Uyumluluk Bilgisi
The manufacturer product page confirms TIA/EIA-232-F compliance and ±15 kV IEC ESD protection, but it does not provide RoHS, REACH, lead-free, halogen-free, or conflict-minerals declarations.