MAX358EPE+ - 8:1 Fault-Protected Analog Multiplexer | Analog Devices
MPN: MAX358EPE+ ✓ AktifMAX358EPE+ Genel Bakış
An analog multiplexer is an interface IC that connects multiple signal sources to one processing channel. The MAX358 family uses this switching architecture to reduce the number of converters, sensor inputs, or control lines required by a measurement system. In the hierarchy of semiconductor devices, it is an analog switch IC, an interface IC, and ultimately a discrete analog function rather than a digital logic component.
The MAX358EPE+ provides eight single-ended channels, 1.8 kOhm on-resistance, and fault protection covering ±35 V beyond the supply rails. Power-off isolation prevents connected sources from being significantly influenced when the device is unpowered. These characteristics make the multiplexer useful for data acquisition, industrial control, test equipment, and instrumentation where signal routing and input protection must coexist in a compact package.
The 16-pin PDIP construction supports through-hole assembly and straightforward inspection or rework on suitable boards. The MAX358 family is identified by Analog Devices as a production product. Circuit designers should still verify signal amplitude, supply voltage, leakage, switching timing, and channel capacitance against their exact system requirements before finalizing the PCB and input-protection network.
Typical uses include multiplexed sensor acquisition, programmable instrumentation, industrial control interfaces, automated test equipment, and data-logging modules. In these applications, the common output can be connected to an ADC or measurement front end while the address and enable controls select the required channel. Care is required when switching high-impedance sources because off leakage, charge injection, and settling time influence measurement accuracy.
A practical design priority is to preserve the mux's fault-protection capability rather than placing unrestricted external voltages directly on every input. Confirm the absolute maximum conditions and ensure that control logic, supply sequencing, and external clamping are compatible with the selected operating state. This page also consolidates practical selection guidance, verified alternatives, and design considerations for engineers evaluating the MAX358EPE+.
Drop-in alternatifler için MAX358EPE+ — aynı paket, pin-başına uyumlu. PCB yeniden montajı gerektiren farklı paket bileşenleri dışlanmıştır.
Bu Serideki Variantlar
Yedek parça uyumlu olan aynı serideki modeller MAX358EPE+ (aynı form faktörü ve ayağa oturma) — farklı olan Halogen-Free Status, Multiplexer Configuration, Product Type.
MAX358CPE+
✅ Yerleştirme📋 Katalogda Olmayan Referans Alternatifi
MAX358EPE
✅ Yerleştirme📋 Katalogda Olmayan Referans Alternatifi
DG458DJ
✅ Yerleştirme📋 Katalogda Olmayan Referans Alternatifi
MPC508AP
✅ YerleştirmeFiyat için iletişime geçin
Veri Şablonunu Görüntüle →MAX358EPE+ Özellikler
| Product Type | Fault-protected analog multiplexer |
| Multiplexer Configuration | Single-ended, 8:1 |
| Number of Channels | 8 channels |
| On-Resistance | 1.8 kOhm |
| Number of Circuits | 1 circuit |
| Paket | 16-pin PDIP |
| Montaj Türü | Through-hole |
| İşletim Sıcaklığı Aralığı | -40°C to +85°C |
| Fault Protection | Protected to ±35 V beyond the supply rails |
| Power-Off Isolation | Supported |
| Off Leakage Current, IS(off), Maximum | 10 µA |
| Halogen-Free Status | Compliant |
MAX358EPE+ 16-pin pdip Pin Yapısı Kılavuzu
MAX358EPE+ (16-pin pdip paket) için pin yapısı. Pin numaralandırma, işlevleri ve bağlantı şemaları üretici veri kitapçığında tanımlanmıştır. Doğru ayak ve soldurma kılavuzları için onu referans alın.
Ayrıntılı pin çıkış verisi mevcut değil: MAX358EPE+.
Aşağıdaki veri sayfası tam pin konfigürasyonu için.
Tipik Uygulamalar
MAX358EPE+ için uygundur 6 uygulamas: Industrial Sensor Acquisition, Programmable Test Equipment, Data Logging Modules, Measurement Front Ends, Communications Equipment, Audio Measurement Systems.
Industrial Sensor Acquisition
The MAX358EPE+ fits multiplexed industrial sensor acquisition because it routes eight single-ended analog inputs to one common measurement path in a 16-pin PDIP package. Its -40°C to +85°C operating range supports demanding factory environments, while fault protection to ±35 V beyond the supply rails adds resilience when sensor wiring is exposed to electrical transients. The 1.8 kOhm on-resistance should be evaluated against sensor impedance, ADC input capacitance, acquisition time, and leakage requirements.
Önerilen
Programmable Test Equipment
The MAX358EPE+ is useful in programmable test equipment where multiple analog sources must be connected selectively to a common measurement instrument. Its 8:1 configuration reduces the number of external routing switches, and the fault-protected inputs can tolerate excursions beyond the normal supply rails during automated testing. The 1.8 kOhm on-resistance and 10 µA maximum reported off leakage are important when configuring high-impedance sources and low-level measurements.
Önerilen
Data Logging Modules
The MAX358EPE+ can consolidate eight analog sensor channels in a compact data-logging module while retaining fault protection and power-off isolation. The single-ended 8:1 architecture is appropriate for systems that periodically sample temperature, pressure, potentiometer, or resistive-sensor outputs through a shared ADC channel. Designers should confirm settling behavior and charge injection against the required sample rate, and use source impedances that interact safely with the 1.8 kOhm on-resistance.
Önerilen
Measurement Front Ends
The MAX358EPE+ suits measurement front ends that require several externally selected inputs feeding a shared amplifier, filter, or ADC. Its single-ended 8:1 arrangement simplifies source selection, while the PDIP package makes through-hole assembly and board-level inspection practical. Fault protection and power-off isolation are valuable when test points can be driven by external equipment, although the exact ±35 V beyond-rail condition and supply limits must be respected in the system design.
Önerilen
Communications Equipment
The MAX358EPE+ can route monitored or injected analog signals within communications equipment where multiple lines must be selected without adding a separate multiplexer for each function. Fault protection helps manage accidental voltage excursions on externally connected lines, while the -40°C to +85°C rating supports industrial communications equipment. The design must verify logic thresholds, switching transients, leakage, and supply sequencing to preserve signal integrity across the selected channel.
Önerilen
Audio Measurement Systems
The MAX358EPE+ can be evaluated for multichannel audio measurement systems that require fault-tolerant routing of several single-ended inputs to a common analysis path. The eight-channel architecture reduces wiring complexity, while the 1.8 kOhm on-resistance may be acceptable for medium- or high-impedance audio sources. For precision audio measurement, verify off leakage, channel isolation, crosstalk, charge injection, and switching noise against the required signal-to-noise performance.
Önerilen
Önerilen Ürünler Özeti
Mühendislik referans verileri: MAX358EPE+ — karşılaştırma, tasarım rehberi ve uyumluluk bilgileri.
Seçim Kılavuzu
Alternatiflerle Karşılaştırma
| Parametre | Bu Ürün | MAX358CPE+ | MAX358EPE | DG458DJ | MPC508AP |
|---|---|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Microchip Technology |
| Package | 16-pin PDIP | 16-pin PDIP | 16-pin PDIP | 16-pin PDIP | 16-pin PDIP |
Ana Farklılayıcılar
- Extended-temperature 8:1 multiplexing (karşılaştırma:MAX358CPE+)
- Established fault-protected interface architecture (karşılaştırma:MPC508AP)
- Single-family electrical configuration (karşılaştırma:DG458DJ)
Tasarım Notları
Treat fault protection and absolute-maximum ratings as separate constraints. The documented ±35 V beyond-rail protection does not permit unrestricted input voltage under every power, temperature, and switching condition. Confirm the supply range, input limits, and enabled or disabled behavior in the manufacturer data sheet, and ensure external fault energy is limited so that input protection does not become the primary energy-absorption component.
Account for the 1.8 kOhm on-resistance when the source impedance is high. The switch resistance combines with the source, amplifier input, and ADC input capacitance to determine the settling time of a channel transition. Estimate the maximum source impedance against the required acquisition time, and confirm that leakage of up to 10 µA does not create an unacceptable error at the signal node.
Use the manufacturer pin-description table when assigning the 16-pin PDIP footprint. Keep analog input traces away from address and enable switching nodes, provide a direct ground return for the multiplexer, and place input filtering or clamping close to externally accessible pins. The fault-protection structure should not be used as a substitute for properly rated external protection when cables or test fixtures can introduce large transients.
Uyumluluk Bilgisi
The cross-reference record identifies the device as halogen-free compliant. RoHS, REACH, lead-free, and conflict-minerals status are not established by the available manufacturer and distributor records.