OPA4137P - Quad 36V 1MHz FET Op Amp | Texas Instruments
MPN: OPA4137P ✓ AktifOPA4137P Genel Bakış
An operational amplifier is a high-gain differential amplifier used to amplify voltage differences while providing feedback-defined gain, filtering, buffering, or signal conditioning. The OPA4137 belongs to the FET-input operational-amplifier family within the broader analog IC and power-management signal-chain hierarchy. Its four amplifiers share a common package while providing independent channels for instrumentation, converters, and active filtering.
The OPA4137P uses low-input-bias-current J-FET input stages, making it suitable for high-impedance sources that would load conventional bipolar transistor inputs. The series documentation identifies input bias current around 10 pA, quiescent current around 120 µA per channel, and open-loop gain around 145 dB for applicable family configurations. The 1 MHz gain-bandwidth product supports moderate-bandwidth precision applications rather than high-speed video or RF signal chains.
Each channel combines low-noise J-FET inputs with a 3.5 V/µs slew rate. The family is intended for low-cost and miniature applications where low bias current, low quiescent current, and compact implementation are important. Because all four channels are integrated into one 14-pin PDIP, designers can reduce external interconnections in multi-channel filters, sensor front ends, and signal-conditioning boards.
Typical applications include low-frequency precision filters, current-to-voltage conversion, audio and instrumentation signal conditioning, sensor amplification, and analog control loops. It is particularly appropriate when source impedances are high enough that input bias current could create an unacceptable DC error. It is less suitable for demanding high-speed, high-output-current, or unity-gain-stable high-voltage applications without careful review of the complete electrical characteristics.
For PCB implementation, place each bypass capacitor close to the associated supply pins, keep feedback components close to their channel pins, and provide a quiet ground reference. Avoid long high-impedance traces because leakage, contamination, and parasitic capacitance can degrade the low-bias-current advantage. Confirm output swing, input common-mode range, noise, distortion, and stability against the actual gain and load before releasing the design.
This page combines manufacturer specifications, package and pin information, sourcing guidance, verified cross-reference results, and practical design notes. It also identifies where an alternative requires explicit engineering review rather than assuming that a similar amplifier function guarantees a board-level drop-in replacement.
Drop-in alternatifler için OPA4137P — aynı paket, pin-başına uyumlu. PCB yeniden montajı gerektiren farklı paket bileşenleri dışlanmıştır.
Bu Serideki Variantlar
Yedek parça uyumlu olan aynı serideki modeller OPA4137P (aynı form faktörü ve ayağa oturma) — farklı olan Input Bias Current, Open-Loop Gain, Quiescent Current.
OPA4990IP
✅ Yerleştirme📋 Katalogda Olmayan Referans Alternatifi
OPA336P
✅ YerleştirmeFiyat için iletişime geçin
Veri Şablonunu Görüntüle →OPA4342PA
✅ Yerleştirme📋 Katalogda Olmayan Referans Alternatifi
OPA4137P Maksimum Değerlendirmeler & Elektriksel Özellikler
| Number of Channels | 4 channels |
| Amplifier Type | J-FET-input operational amplifier |
| Maximum Total Supply Voltage | 36 V |
| Supply Voltage Range | ±2.25 V to ±18 V |
| Gain-Bandwidth Product | 1 MHz |
| Slew Rate | 3.5 V/µs |
| Input Bias Current | Approximately 10 pA for the OPA137 series |
| Durağan Akım | Approximately 120 µA per channel for the OPA137 series |
| Open-Loop Gain | Approximately 145 dB for the OPA137 series |
| Input Common-Mode Capability | Rail-to-rail input |
| Package Type | 14-pin PDIP |
| Pin Sayısı | 14 pins |
| Montaj Türü | Through-hole |
OPA4137P Pin Yapısı
| Pin 1 | OUTA — Amplifier A output |
| Pin 2 | INA- — Amplifier A inverting input |
| Pin 3 | INA+ — Amplifier A non-inverting input |
| Pin 4 | V+ — Positive supply connection |
| Pin 5 | INB+ — Amplifier B non-inverting input |
| Pin 6 | INB- — Amplifier B inverting input |
| Pin 7 | OUTB — Amplifier B output |
| Pin 8 | OUTC — Amplifier C output |
| Pin 9 | INC- — Amplifier C inverting input |
| Pin 10 | INC+ — Amplifier C non-inverting input |
| Pin 11 | V- — Negative supply connection |
| Pin 12 | IND+ — Amplifier D non-inverting input |
| Pin 13 | IND- — Amplifier D inverting input |
| Pin 14 | OUTD — Amplifier D output |
Tipik Uygulamalar
OPA4137P için uygundur 6 uygulamas: High-Impedance Sensor Signal Conditioning, Precision Active Filters, Current-to-Voltage Conversion, Audio and Instrumentation Buffering, Industrial Analog Control Loops, Low-Power Precision Analog.
High-Impedance Sensor Signal Conditioning
The OPA4137P suits low-frequency sensor amplifiers because its J-FET input stage provides approximately 10 pA bias current for the relevant OPA137 series configuration. That low current limits the input-voltage error created when source resistance is high. Place the amplifier close to the sensor connector and use guarding or a driven shield if contamination and cable leakage are significant. The 1 MHz bandwidth is ample for many resistive sensors but should be matched to the sensor bandwidth to avoid unnecessary noise amplification.
Önerilen
Precision Active Filters
The OPA4137P can implement multi-channel active filters where four matched amplifier sections simplify board area and reduce channel-count variations. Its 1 MHz gain-bandwidth product and 3.5 V/µs slew rate support low-frequency precision filtering, while the J-FET inputs reduce errors associated with high-value feedback networks. Component tolerances, resistor matching, and the amplifier's open-loop gain will influence filter accuracy. Verify the selected gain-bandwidth combination and capacitive loading in the manufacturer's stability guidance before fabrication.
Önerilen
Current-to-Voltage Conversion
The OPA4137P is appropriate for transimpedance and current-to-voltage conversion stages where low input bias current helps preserve the accuracy of weak sensor currents. The approximately 10 pA input-bias-current characteristic for the applicable OPA137 series configuration reduces DC error across high feedback resistors. Use short guarded input paths, clean high-impedance PCB regions, and a carefully selected feedback capacitor. The 1 MHz gain-bandwidth product also places a practical ceiling on the achievable closed-loop bandwidth.
Önerilen
Audio and Instrumentation Buffering
Four independent OPA4137P channels can provide input buffering, gain stages, and balanced signal-conditioning paths in audio and instrumentation equipment. The approximately 120 µA per-channel quiescent current for the relevant OPA137 series configuration is useful in compact systems, while the 36 V maximum total supply rating supports conventional ±15 V or ±18 V laboratory rails. Confirm output swing into the intended load and evaluate distortion at the actual signal level. Feedback-network placement should minimize noise pickup and channel-to-channel coupling.
Önerilen
Industrial Analog Control Loops
The OPA4137P can implement low-frequency industrial control loops, error amplifiers, and actuator-signal interfaces when the source impedance is high and supply headroom is limited by the installation. Its ±2.25 V to ±18 V operating range supports split supplies common in industrial analog systems. Because the device is not a power amplifier, verify output current, output swing, capacitive-load behavior, and loop stability against the actuator interface. Add transient protection at exposed connectors and maintain separate return paths for high-current outputs.
Önerilen
Low-Power Precision Analog
The OPA4137P suits portable measurement and control equipment where a four-channel low-power analog front end simplifies system design. The OPA137 series documentation identifies approximately 120 µA quiescent current per channel for applicable configurations, and the 3.5 V/µs slew rate is sufficient for many sensor signals and low-frequency control waveforms. Assess total supply current across all four channels and any downstream converters. For battery-powered operation, validate the complete rail range, output load, and duty cycle rather than relying on the no-load quiescent-current figure alone.
Önerilen
Önerilen Ürünler Özeti
Mühendislik referans verileri: OPA4137P — karşılaştırma, tasarım rehberi ve uyumluluk bilgileri.
Seçim Kılavuzu
Alternatiflerle Karşılaştırma
| Parametre | Bu Ürün | OPA4990IP | OPA336P | OPA4342PA |
|---|---|---|---|---|
| Package | 14-pin PDIP | 14-pin PDIP | 14-pin PDIP | 14-pin PDIP |
| Brand | Texas Instruments | Texas Instruments | Analog Devices | Texas Instruments |
| Number of Channels | 4 channels | 4 channels | 4 channels | 4 channels |
Ana Farklılayıcılar
- Lower-bias-current input architecture (karşılaştırma:OPA4990IP)
- Lower-voltage operating envelope for compact designs (karşılaştırma:OPA4990IP)
- Documented cross-family equivalence (karşılaştırma:OPA336P)
Tasarım Notları
Place the positive and negative bypass capacitors as close as practical to the OPA4137P supply pins, and route them using short ground returns. For high-impedance inputs, keep the sensitive nodes away from switching nodes, inductors, relay contacts, and connector edges. The low input bias current of the J-FET input stage can be undermined by flux residue, conformal-coating contamination, or dirty board surfaces, so cleaning and guarding are important engineering controls.
Do not treat the 36 V rating as a ±36 V operating supply. The specified range is ±2.25 V to ±18 V, meaning the total voltage across the supply pins must remain within 36 V. Also verify rail-to-rail input operation at the selected common-mode voltage, output swing into the actual load, and closed-loop stability. The 1 MHz bandwidth and 3.5 V/µs slew rate do not by themselves guarantee stability at every gain or capacitive load.
For transimpedance and high-source-impedance designs, minimize input-node capacitance and use a feedback network selected for the intended closed-loop bandwidth. Keep the feedback resistor and compensation capacitor adjacent to the relevant channel. If the source is remote, consider guarding, a driven shield, or a nearby low-input-bias-current buffer. Validate leakage, settling time, and channel interaction on the actual board because connector and coating contamination can dominate the nominal amplifier error.
Estimate the amplifier's supply consumption from the approximately 120 µA per-channel family value plus output current and bias-current contributions, then apply a suitable margin for the complete circuit. Do not treat quiescent current as the total board demand. In single-supply systems, confirm that input bias, output swing, and common-mode range provide adequate headroom, and power the unused channels according to the datasheet's input-stage recommendations.
Uyumluluk Bilgisi
No explicit RoHS, REACH, lead-free, halogen-free, or conflict-minerals status was identified for the exact OPA4137P ordering code. The product is an industrial instrumentation amplifier application rather than an AEC-Q100 automotive-qualified device.