An RS-232 interface IC is a semiconductor bridge between low-voltage digital logic and a physical RS-232 communications port. RS-232 uses single-ended, bipolar signaling that can employ voltage levels beyond the supply rails of ordinary CMOS logic. The ADM230LAQ combines driver channels for transmitting data with receiver channels for detecting incoming signals, allowing a +5 V system to communicate with legacy, industrial, or instrumentation equipment without external ±12 V supplies.
The ADM230LAQ operates from one 5 V supply and includes onboard DC-DC converters that allow the driver output to reach approximately 9 V of swing. Its specified data rate of 120 kB/s supports higher-speed serial links than legacy limited-rate RS-232 implementations. The receiver section supports 1 A input current handling and receiver inputs remain active during shutdown, helping preserve inbound communication when the transmitter side is powered down.
The interface circuitry is designed for EIA-232-E and V.28 implementations. Those standards define the electrical behavior expected of RS-232 drivers, receivers, and signal levels in point-to-point communications. Small 1 F capacitors are used with the onboard converters, allowing the complete interface to be implemented with a single low-voltage supply rather than separate positive and negative power rails.
Typical uses include industrial control equipment, test and measurement systems, point-of-sale terminals, embedded serial ports, and legacy peripheral interfaces. In each case, the five interface channels can support multi-channel RS-232 equipment while the 120 kB/s capability accommodates moderately high-speed command, status, and data traffic.
Designers should preserve the converter capacitor recommendations and route the interface return path as a continuous ground conductor. The ceramic DIP package supports through-hole insertion and thermal conduction, but its operating temperature grade and exact environmental qualifications must be checked against the current manufacturer documentation before deployment.
This page consolidates the confirmed ADM230LAQ interface specifications, package information, application guidance, and clearly qualified replacement considerations. It also distinguishes directly verified functions from parameters that require confirmation in the manufacturer datasheet, helping engineers plan a complete single-supply RS-232 implementation.
کے لیے ڈراپ اِن متبادل ADM230LAQ — یکساں پیکیج، پن سے پن مطابقت پذیر۔ مختلف پیکیج والے پرزے جن کے لیے PCB دوبارہ کام درکار ہو، شامل نہیں ہیں۔
اس سیریز میں مختلف ورژن
اسی سیریز کے ماڈلز جو ڈراپ اِن مطابقت رکھتے ہیں ADM230LAQ (یکساں فارم فیکٹر اور فٹ پرنٹ) — میں مختلف Package, Product Type.
اس پروڈکٹ کے لیے کوئی ڈراپ اِن متبادل دستیاب نہیں۔
متبادل کی درخواست کریںADM230LAQ تفصیلات
| Product Type | 5 V powered CMOS RS-232 drivers/receivers |
| سپلائی وولٹیج | 5 V |
| Number of Channels | 5 channels |
| Maximum Data Rate | 120 kB/s |
| Driver Output Swing | 9 V |
| Receiver Input Current | 1 A |
| Receiver Input Voltage | 30 V |
| Converter Capacitor | 1 F |
| Shutdown Feature | Low-power shutdown with receivers active |
| Onboard Converter | DC-DC converter |
| RS-232 Compliance | EIA-232-E and V.28 |
| Logic Family | CMOS |
| پیکیج | 20-CDIP, 0.300 in (7.62 mm) |
| ماؤنٹنگ ٹائپ | Through-hole |
| Number of Terminals | 20 terminals |
ADM230LAQ 20-cdip, 0.300 in (7.62 mm) پن کنفیگریشن گائیڈ
ADM230LAQ (20-cdip, 0.300 in (7.62 mm) پیکیج) کے لیے پن کنفیگریشن۔ پن نمبرنگ، فنکشنز اور کنکشن ڈایاگرامز مینوفیکچرر کے ڈیٹا شیٹ میں بیان کیے گئے ہیں۔ درست فٹ پرنٹ اور سولڈرنگ رہنما ہدایات کے لیے اسی سے رجوع کریں۔
کے لیے تفصیلی پن آؤٹ ڈیٹا دستیاب نہیں ADM230LAQ.
رجوع کریں ڈیٹا شیٹ مکمل پن کنفیگریشن کے لیے۔
عام استعمالات
ADM230LAQ کے لیے موزوں ہے 6 ایپلیکیشنs: Industrial Control Terminals, Test and Measurement Equipment, Point-of-Sale and Retail Equipment, Legacy Computer Serial Ports, Instrument Communication Interfaces, Embedded Data Acquisition Systems.
Industrial Control Terminals
The ADM230LAQ fits industrial control terminals that need several RS-232 ports but only have a 5 V power rail. Its five driver/receiver channels can connect controllers, indicators, scales, and configuration tools without requiring separate positive and negative RS-232 supplies. Operation at up to 120 kB/s supports responsive status polling and moderate command traffic, while the onboard DC-DC converters deliver approximately 9 V of driver swing. The 20-CDIP format also suits equipment assembled with through-hole processes. Design the converter-capacitor layout exactly as directed by the manufacturer and maintain a continuous signal-ground path between the terminal and connected equipment.
تجویز کردہ
Test and Measurement Equipment
The ADM230LAQ is useful in test and measurement instruments that retain RS-232 for instrument control, calibration, or legacy peripheral connectivity. The single 5 V supply simplifies front-panel and embedded instrument designs, and the 120 kB/s data rate is suitable for command exchange and moderate measurement transfers. Five channels allow one instrument to manage several RS-232 links without allocating a separate transceiver to every port. EIA-232-E and V.28 compatibility supports conventional control-system interoperability. Keep converter capacitors near their assigned pins and isolate interface traces from sensitive measurement circuitry to avoid coupling command activity into high-impedance analog nodes.
تجویز کردہ
Point-of-Sale and Retail Equipment
Retail peripherals such as scales, receipt printers, customer displays, and barcode equipment can use the ADM230LAQ for RS-232 connectivity in a 5 V embedded controller. The five-channel arrangement supports several peripherals from one interface device, and the 120 kB/s rate accommodates ordinary transaction and status traffic. Because many countertop systems have limited supply rails, onboard DC-DC conversion and a single 5 V input simplify system integration. The 20-CDIP package is appropriate for products assembled on through-hole boards. Use the manufacturer capacitor and grounding layout to preserve signal integrity, particularly when cables from printers or scales are physically distant from the logic board.
تجویز کردہ
Legacy Computer Serial Ports
The ADM230LAQ provides a practical bridge between modern +5 V logic and legacy RS-232 ports found on industrial computers, service equipment, and specialized peripherals. Its five channels allow one IC to service several serial connectors, while the approximately 9 V driver swing and EIA-232-E and V.28 behavior maintain compatibility with conventional RS-232 voltage expectations. A 120 kB/s ceiling supports faster legacy transfers than many basic RS-232 implementations. During shutdown, the receiver channels remain active, allowing inbound status or control signals to persist when the transmitter side is disabled. Validate grounding and cable routing to avoid ground-offset errors at the connected port.
تجویز کردہ
Instrument Communication Interfaces
The ADM230LAQ is appropriate for instruments that expose RS-232 command ports to laboratory computers or embedded controllers. The 5 V supply requirement is convenient for compact instruments, while the 120 kB/s data rate supports responsive command polling, configuration uploads, and status reads. Multiple receiver and driver channels can be allocated to separate instruments, provided the design follows the manufacturer’s per-channel loading and shutdown guidance. The receiver input rating of 30 V offers substantial withstand margin, but it should not be interpreted as permission for continuous operation outside the specified input range. Use a controlled ground reference and place the 1 F converter capacitors as directed.
تجویز کردہ
Embedded Data Acquisition Systems
The ADM230LAQ can connect legacy sensors, programmable instruments, and laboratory modules to a +5 V embedded controller. Its five channels support several RS-232 devices in one acquisition chassis, and the 120 kB/s rate accommodates periodic measurements and command traffic where sustained high-speed streaming is not required. The onboard converters eliminate a separate bipolar RS-232 supply, helping reduce board complexity in space-constrained systems. The through-hole CDIP package may simplify ruggedized control boards and prototype assembly. Separate converter and switching circuitry from sensitive acquisition inputs, use the specified 1 F capacitors, and provide a low-impedance ground return to minimize errors at the connected equipment.
تجویز کردہ
تجویز کردہ پروڈکٹس کا خلاصہ
کے لیے انجینئرنگ ریفرنس ڈیٹا ADM230LAQ — موازنہ، ڈیزائن رہنمائی، اور تعمیل کی معلومات۔
انتخاب کی گائیڈ
ڈیزائن نوٹس
Place the required 1 F converter capacitors at the locations assigned by the manufacturer datasheet and keep their associated traces short. The available information confirms the capacitor value and single-supply converter function but does not reproduce the pinout, so the final placement must be checked against the device drawing. Avoid routing converter-current paths across sensitive receiver or measurement signals, and provide a continuous ground plane beneath the interface area where the package and board construction permit.
Keep RS-232 driver and receiver traces away from clocks, switching-regulator nodes, and high-impedance analog inputs. Maintain a continuous signal-ground return to the connected equipment because RS-232 is a single-ended interface and ground potential differences can appear as data errors. If the ADM230LAQ sits near a cable connector, place transient-protection structures at the connector boundary and use the receiver’s 30 V input rating as protection margin rather than as a substitute for a correctly selected protection network.
Do not substitute an ADM230 family member solely because its product description mentions EIA-232-E or V.28 compatibility. Verify the package suffix, pin names, pin numbers, converter implementation, shutdown behavior, temperature grade, and lead dimensions before approving a replacement. Also avoid assuming that receiver operation during shutdown makes every channel suitable for live use; follow the datasheet limits for signal amplitude, loading, and data state.
تعمیل کی معلومات
No explicit RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals declarations were identified for ADM230LAQ. The industrial temperature classification shown by a distributor listing does not by itself constitute AEC-Q100 qualification.