ICL7137RCPL - 3.5-Digit BCD ADC/Display Driver | Harris
MPN: ICL7137RCPL ✓ فعالICL7137RCPL جائزہ
A BCD ADC is a specialized analog-to-digital converter intended for decimal instrumentation. Unlike a binary-output converter, it produces BCD digits that can be decoded directly for a numeric display. The ICL7137 belongs to the ADC/DAC special-purpose category and integrates conversion, digit decoding, display driving, a voltage reference, and clock circuitry in one through-hole device. This integration reduces the component count in a digital panel meter compared with separate converter and driver ICs.
The ICL7137 architecture is designed for high input impedance, helping the measurement system avoid loading the sensor or bridge circuit. Its multiplexed seven-segment output reduces the number of interconnections required between the converter and display. A 3.5-digit format provides 1999-count resolution for positive readings and is commonly used where direct decimal presentation is more useful than general-purpose binary conversion.
The integrated clock and voltage-reference functions establish repeatable conversion timing and measurement scaling. In ratiometric operation, the reference and input are derived from the same excitation source, which causes supply or sensor-excitation variations to affect both signals proportionally. The practical benefit is improved stability in bridge-based instruments and simpler calibration compared with a measurement architecture that uses an unrelated reference.
Typical uses include laboratory digital multimeters, process-panel meters, temperature indicators, weighing scales, and industrial instrumentation. The 40-pin PDIP package is suitable for through-hole assembly and prototype boards. Because its operating range is 0°C to 70°C, the device is intended for commercial-temperature equipment rather than extended industrial or automotive environments.
Designers should follow the manufacturer pin description and typical connection diagram when assigning input, reference, clock, segment, and supply connections. Input-source impedance can influence conversion accuracy, so sensor and conditioning networks should be evaluated for settling time and source resistance. PCB layout should keep analog input traces away from display-output transitions, while the supply and reference portions should use stable, low-noise routing.
This product page consolidates the confirmed package and operating details, a like-for-like replacement candidate, application guidance, and design considerations. It also highlights the functional distinction between the original Harris device and the Maxim/Analog Devices part available in the same 40-pin PDIP format, helping engineers evaluate replacement risk before modifying an existing design.
کے لیے ڈراپ اِن متبادل ICL7137RCPL — یکساں پیکیج، پن سے پن مطابقت پذیر۔ مختلف پیکیج والے پرزے جن کے لیے PCB دوبارہ کام درکار ہو، شامل نہیں ہیں۔
اس سیریز میں مختلف ورژن
اسی سیریز کے ماڈلز جو ڈراپ اِن مطابقت رکھتے ہیں ICL7137RCPL (یکساں فارم فیکٹر اور فٹ پرنٹ) — میں مختلف Package.
ICL7137CPL+
✅ ڈراپ-اِنقیمت کے لیے رابطہ کریں
ڈیٹا شیٹ دیکھیں →ICL7137CPL+
✅ ڈراپ-اِنقیمت کے لیے رابطہ کریں
ڈیٹا شیٹ دیکھیں →ICL7137RCPL زیادہ سے زیادہ ریٹنگز اور برقی خصوصیات
| Device Type | ADC, Display Driver |
| ریزولوشن | 3.5 digits |
| Output Format | BCD |
| Number of Channels | 1 channel |
| سپلائی وولٹیج | 5 V |
| آپریٹنگ درجہ حرارت | 0°C to 70°C |
| ماؤنٹنگ اسٹائل | Through Hole |
| پیکیج | 40-DIP (0.600 in, 15.24 mm) |
| Input Type | Differential/Single-Ended |
| Reference Type | Internal/Ratiometric |
| Conversion Timing | 4,000 counts/s typical |
| Input Impedance | 1 GΩ minimum |
| Display Output | Seven-segment multiplexed driver |
| Lead-Free | unknown |
| RoHS | unknown |
ICL7137RCPL 40-dip (0.600 in, 15.24 mm) پن کنفیگریشن گائیڈ
ICL7137RCPL (40-dip (0.600 in, 15.24 mm) پیکیج) کے لیے پن کنفیگریشن۔ اس اینالاگ کمپوننٹ میں اِن پٹ، آؤٹ پٹ اور پاور سپلائی پنز شامل ہیں۔ آفسیٹ نل، کمپنسیشن اور اِن ایبل پن کنفیگریشنز کے لیے مینوفیکچرر کے ڈیٹا شیٹ سے رجوع کریں۔ سگنل کنڈیشننگ اور ایمپلیفائر سرکٹس کے لیے مثالی۔
کے لیے تفصیلی پن آؤٹ ڈیٹا دستیاب نہیں ICL7137RCPL.
رجوع کریں ڈیٹا شیٹ مکمل پن کنفیگریشن کے لیے۔
عام استعمالات
ICL7137RCPL کے لیے موزوں ہے 6 ایپلیکیشنs: Digital Panel Meters, Laboratory Measurement Instruments, Industrial Process Displays, Temperature Indication, Weighing and Bridge Scales, Bench Power and Test Readouts.
Digital Panel Meters
The ICL7137RCPL fits digital panel meters because it combines a 3.5-digit BCD converter with multiplexed seven-segment display drive in one 40-pin PDIP device. The 5 V operating supply suits conventional instrument rails, while 0°C to 70°C covers typical indoor environments. Its integrated clock, reference, decoding, and output circuitry reduces the number of external ICs in a compact meter. The designer must still match display current and polarity, and confirm the exact converter timing and enable behavior against the manufacturer pin and application diagrams.
تجویز کردہ
Laboratory Measurement Instruments
The ICL7137RCPL is useful in laboratory meters where a stable decimal readout is required from a relatively high-impedance analog source. The 1 GΩ minimum input impedance helps prevent the converter from materially loading the front-end, and the 3.5-digit BCD output naturally supports seven-segment decimal presentation. Its 5 V supply simplifies integration with conventional laboratory electronics. For accurate results, the input network must settle completely between conversions, and analog signal paths should be isolated from display-driver switching.
تجویز کردہ
Industrial Process Displays
The ICL7137RCPL can serve as the conversion and display-driving element of an industrial process display when the enclosure remains within its 0°C to 70°C range. The integrated display driver and BCD decoding simplify the path from a conditioned analog measurement to a readable decimal panel. Ratiometric operation is particularly useful when a bridge transducer shares its excitation with the reference, improving rejection of excitation drift. The final board should include transient protection, stable reference routing, and adequate separation between the analog input and multiplexed display outputs.
تجویز کردہ
Temperature Indication
The ICL7137RCPL is suitable for a direct-reading temperature indicator when a linearized sensor signal is presented to the converter input. Its 3.5-digit BCD format and integrated display drive reduce the logic needed to present degrees, while high input impedance helps maintain compatibility with buffer-based sensor conditioning. The 5 V supply supports common analog front ends, although the stated 0°C to 70°C component range must be distinguished from the intended temperature-measurement span. Designers should verify sensor linearity, excitation behavior, and display update performance.
تجویز کردہ
Weighing and Bridge Scales
The ICL7137RCPL fits bridge-based weighing systems because its high-input-impedance measurement front end can minimize bridge loading, while ratiometric reference operation can reduce the effect of excitation variation. The integrated BCD conversion and seven-segment drive provide a direct path to a compact weight display. System accuracy still depends on mechanical repeatability, excitation stability, sensor lead resistance, and input settling. The reference arrangement and input compensation should follow the manufacturer application guidance to preserve repeatability and reject offset errors.
تجویز کردہ
Bench Power and Test Readouts
The ICL7137RCPL is applicable to bench instruments that need a simple decimal voltage or current readout rather than a general-purpose data-acquisition interface. Its 3.5-digit converter, internal clock, and display drive reduce circuit complexity, while the 5 V rail matches many compact instrument designs. The conversion rate of approximately 4,000 counts per second allows responsive meter readings without a separate display controller. Designers should account for input protection, filtering, reference accuracy, and the fact that the 40-pin PDIP footprint requires through-hole board construction.
تجویز کردہ
تجویز کردہ پروڈکٹس کا خلاصہ
کے لیے انجینئرنگ ریفرنس ڈیٹا ICL7137RCPL — موازنہ، ڈیزائن رہنمائی، اور تعمیل کی معلومات۔
انتخاب کی گائیڈ
متبادلات کے ساتھ موازنہ
| پیرامیٹر | یہ پروڈکٹ | ICL7137CPL+ | ICL7137CPL |
|---|---|---|---|
| Package | 40-DIP (0.600 in, 15.24 mm) | 40-PDIP | 40-PDIP |
| Brand | Harris Corporation | Analog Devices Inc./Maxim Integrated | Intersil |
اہم امتیازی خصوصیات
- Original Harris Corporation component identity (بمقابلہICL7137CPL+)
- Commercial-temperature operation (بمقابلہICL7137CPL+)
- Confirmed 40-pin through-hole package (بمقابلہICL7137CPL)
ڈیزائن نوٹس
Route the analog input and reference nets away from the multiplexed display outputs, because segment-driver transitions can couple into a high-impedance measurement input. Keep the input path short and place any input filtering capacitors close to the relevant device pins. Use a quiet ground-return strategy for the converter section so display current does not share the sensitive analog ground path.
Decouple the 5 V supply at the ICL7137RCPL with the capacitance and placement specified by the manufacturer application diagram. Keep the supply path away from the analog-input region and provide adequate source current for the converter plus display load. If the display draws substantial current, route its supply separately and join it at the appropriate power-distribution point to limit converter-reference disturbance.
Do not assume that every ICL7137 ordering suffix is electrically identical. Before replacing ICL7137RCPL, compare the complete pin description, display polarity, reference configuration, enable logic, conversion timing, and temperature grade in the manufacturer datasheet. A matching 40-pin package establishes mechanical compatibility, but it does not by itself prove that every board option is interchangeable.
Validate input settling against the selected conversion rate. Estimated: source resistance and input-capacitance form a settling time constant, while the converter must acquire the input within its specified acquisition window. Compare the calculated settling time with the available conversion interval, then add input protection and filtering components only after their bias-current and leakage effects are accounted for.
تعمیل کی معلومات
Compliance declarations are not stated in the product information. The component is a commercial-temperature measurement IC and is not presented as an AEC-Q100-qualified automotive device.