A BCD ADC is a specialized analog-to-digital converter intended for decimal instrumentation. Unlike a binary-output converter, it produces BCD digits that can be decoded directly for a numeric display. The ICL7137 belongs to the ADC/DAC special-purpose category and integrates conversion, digit decoding, display driving, a voltage reference, and clock circuitry in one through-hole device. This integration reduces the component count in a digital panel meter compared with separate converter and driver ICs.
The ICL7137 architecture is designed for high input impedance, helping the measurement system avoid loading the sensor or bridge circuit. Its multiplexed seven-segment output reduces the number of interconnections required between the converter and display. A 3.5-digit format provides 1999-count resolution for positive readings and is commonly used where direct decimal presentation is more useful than general-purpose binary conversion.
The integrated clock and voltage-reference functions establish repeatable conversion timing and measurement scaling. In ratiometric operation, the reference and input are derived from the same excitation source, which causes supply or sensor-excitation variations to affect both signals proportionally. The practical benefit is improved stability in bridge-based instruments and simpler calibration compared with a measurement architecture that uses an unrelated reference.
Typical uses include laboratory digital multimeters, process-panel meters, temperature indicators, weighing scales, and industrial instrumentation. The 40-pin PDIP package is suitable for through-hole assembly and prototype boards. Because its operating range is 0°C to 70°C, the device is intended for commercial-temperature equipment rather than extended industrial or automotive environments.
Designers should follow the manufacturer pin description and typical connection diagram when assigning input, reference, clock, segment, and supply connections. Input-source impedance can influence conversion accuracy, so sensor and conditioning networks should be evaluated for settling time and source resistance. PCB layout should keep analog input traces away from display-output transitions, while the supply and reference portions should use stable, low-noise routing.
This product page consolidates the confirmed package and operating details, a like-for-like replacement candidate, application guidance, and design considerations. It also highlights the functional distinction between the original Harris device and the Maxim/Analog Devices part available in the same 40-pin PDIP format, helping engineers evaluate replacement risk before modifying an existing design.
直接替換替代品,適用於 ICL7137RCPL — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: ICL7137RCPL (相同外形與佔位) — 差異在於 Package.
ICL7137CPL+
✅ 直接替換聯絡詢價
查看資料表 →ICL7137CPL+
✅ 直接替換聯絡詢價
查看資料表 →ICL7137RCPL 最大額定值與電氣特性
| Device Type | ADC, Display Driver |
| 解析度 | 3.5 digits |
| Output Format | BCD |
| Number of Channels | 1 channel |
| 供應電壓 | 5 V |
| 工作溫度 | 0°C to 70°C |
| 安裝方式 | Through Hole |
| 封裝 | 40-DIP (0.600 in, 15.24 mm) |
| Input Type | Differential/Single-Ended |
| Reference Type | Internal/Ratiometric |
| Conversion Timing | 4,000 counts/s typical |
| Input Impedance | 1 GΩ minimum |
| Display Output | Seven-segment multiplexed driver |
| Lead-Free | unknown |
| RoHS | unknown |
ICL7137RCPL 40-dip (0.600 in, 15.24 mm) 腳位配置指南
ICL7137RCPL(40-dip (0.600 in, 15.24 mm) 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: ICL7137RCPL.
請參閱 資料表 以查看完整腳位配置。
典型應用
ICL7137RCPL 適用於 6 應用s: Digital Panel Meters, Laboratory Measurement Instruments, Industrial Process Displays, Temperature Indication, Weighing and Bridge Scales, Bench Power and Test Readouts.
Digital Panel Meters
The ICL7137RCPL fits digital panel meters because it combines a 3.5-digit BCD converter with multiplexed seven-segment display drive in one 40-pin PDIP device. The 5 V operating supply suits conventional instrument rails, while 0°C to 70°C covers typical indoor environments. Its integrated clock, reference, decoding, and output circuitry reduces the number of external ICs in a compact meter. The designer must still match display current and polarity, and confirm the exact converter timing and enable behavior against the manufacturer pin and application diagrams.
推薦
Laboratory Measurement Instruments
The ICL7137RCPL is useful in laboratory meters where a stable decimal readout is required from a relatively high-impedance analog source. The 1 GΩ minimum input impedance helps prevent the converter from materially loading the front-end, and the 3.5-digit BCD output naturally supports seven-segment decimal presentation. Its 5 V supply simplifies integration with conventional laboratory electronics. For accurate results, the input network must settle completely between conversions, and analog signal paths should be isolated from display-driver switching.
推薦
Industrial Process Displays
The ICL7137RCPL can serve as the conversion and display-driving element of an industrial process display when the enclosure remains within its 0°C to 70°C range. The integrated display driver and BCD decoding simplify the path from a conditioned analog measurement to a readable decimal panel. Ratiometric operation is particularly useful when a bridge transducer shares its excitation with the reference, improving rejection of excitation drift. The final board should include transient protection, stable reference routing, and adequate separation between the analog input and multiplexed display outputs.
推薦
Temperature Indication
The ICL7137RCPL is suitable for a direct-reading temperature indicator when a linearized sensor signal is presented to the converter input. Its 3.5-digit BCD format and integrated display drive reduce the logic needed to present degrees, while high input impedance helps maintain compatibility with buffer-based sensor conditioning. The 5 V supply supports common analog front ends, although the stated 0°C to 70°C component range must be distinguished from the intended temperature-measurement span. Designers should verify sensor linearity, excitation behavior, and display update performance.
推薦
Weighing and Bridge Scales
The ICL7137RCPL fits bridge-based weighing systems because its high-input-impedance measurement front end can minimize bridge loading, while ratiometric reference operation can reduce the effect of excitation variation. The integrated BCD conversion and seven-segment drive provide a direct path to a compact weight display. System accuracy still depends on mechanical repeatability, excitation stability, sensor lead resistance, and input settling. The reference arrangement and input compensation should follow the manufacturer application guidance to preserve repeatability and reject offset errors.
推薦
Bench Power and Test Readouts
The ICL7137RCPL is applicable to bench instruments that need a simple decimal voltage or current readout rather than a general-purpose data-acquisition interface. Its 3.5-digit converter, internal clock, and display drive reduce circuit complexity, while the 5 V rail matches many compact instrument designs. The conversion rate of approximately 4,000 counts per second allows responsive meter readings without a separate display controller. Designers should account for input protection, filtering, reference accuracy, and the fact that the 40-pin PDIP footprint requires through-hole board construction.
推薦
推薦產品摘要
工程參考資料,適用於 ICL7137RCPL — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | ICL7137CPL+ | ICL7137CPL |
|---|---|---|---|
| Package | 40-DIP (0.600 in, 15.24 mm) | 40-PDIP | 40-PDIP |
| Brand | Harris Corporation | Analog Devices Inc./Maxim Integrated | Intersil |
主要差異化特點
- Original Harris Corporation component identity (對比ICL7137CPL+)
- Commercial-temperature operation (對比ICL7137CPL+)
- Confirmed 40-pin through-hole package (對比ICL7137CPL)
設計說明
Route the analog input and reference nets away from the multiplexed display outputs, because segment-driver transitions can couple into a high-impedance measurement input. Keep the input path short and place any input filtering capacitors close to the relevant device pins. Use a quiet ground-return strategy for the converter section so display current does not share the sensitive analog ground path.
Decouple the 5 V supply at the ICL7137RCPL with the capacitance and placement specified by the manufacturer application diagram. Keep the supply path away from the analog-input region and provide adequate source current for the converter plus display load. If the display draws substantial current, route its supply separately and join it at the appropriate power-distribution point to limit converter-reference disturbance.
Do not assume that every ICL7137 ordering suffix is electrically identical. Before replacing ICL7137RCPL, compare the complete pin description, display polarity, reference configuration, enable logic, conversion timing, and temperature grade in the manufacturer datasheet. A matching 40-pin package establishes mechanical compatibility, but it does not by itself prove that every board option is interchangeable.
Validate input settling against the selected conversion rate. Estimated: source resistance and input-capacitance form a settling time constant, while the converter must acquire the input within its specified acquisition window. Compare the calculated settling time with the available conversion interval, then add input protection and filtering components only after their bias-current and leakage effects are accounted for.