±2.25 V to ±18 V Vdss 5 nA maximum Id 16-pin plastic DIP (PDIP) Package
MOQ: 1 |

INA2141P جائزہ

The Texas Instruments INA2141P is a dual, low-power instrumentation amplifier offering selectable gains of 10 and 100 in a 16-pin plastic DIP package. Each amplifier combines low offset voltage, low drift, high common-mode rejection, current-feedback input circuitry, and wide bandwidth for precision analog signal conditioning. The INA2141P is designed for applications that require accurate amplification of differential signals in the presence of substantial common-mode voltage.

An instrumentation amplifier is a specialized analog amplifier optimized for measuring low-level differential signals, such as sensor outputs, while rejecting common-mode noise and voltage. Unlike a general-purpose operational amplifier, an instrumentation amplifier provides high input impedance, consistent gain accuracy, and strong common-mode rejection in a single integrated circuit. The INA2141 family is a dual instrumentation amplifier, so one package can process two independent channels.

The INA2141P supports two fixed gain settings, 10 and 100, and uses current-feedback input circuitry to maintain bandwidth at higher gain. The manufacturer datasheet states that bandwidth reaches 200 kHz at a gain of 100. Low offset voltage is specified at 50 µV maximum, with maximum drift of 0.5 µV/°C and gain accuracy of ±0.05%. Common-mode rejection reaches 117 dB minimum at a gain of 100.

The device accepts supply voltages as low as ±2.25 V and operates with supplies up to ±18 V. Input protection extends to ±40 V, helping the amplifier withstand overload conditions in sensor interfaces and industrial measurement systems. Quiescent current is approximately 750 µA per amplifier, making the device suitable for low-power and battery-operated instrumentation.

Typical uses include bridge-sensor and pressure-transducer interfaces, medical monitoring, industrial process measurement, current-loop sensing, and laboratory instrumentation. Because the INA2141P is a dual amplifier, it is especially useful for paired sensors or two-stage measurement systems where board area and power consumption are important.

Designers should verify the gain-setting resistor configuration, reference-voltage implementation, input common-mode range, and supply headroom against the datasheet before layout. Decoupling capacitors should be placed close to the supply pins, and the analog input traces should be routed away from switching nodes. The manufacturer datasheet also provides application guidance for gain selection, bandwidth, and input protection.

This page combines the verified manufacturer and distributor information for INA2141P with package-level guidance, application context, and design considerations that help engineers evaluate the device alongside alternative instrumentation-amplifier implementations.

کے لیے ڈراپ اِن متبادل INA2141P — یکساں پیکیج، پن سے پن مطابقت پذیر۔ مختلف پیکیج والے پرزے جن کے لیے PCB دوبارہ کام درکار ہو، شامل نہیں ہیں۔

INA2141PA

✅ ڈراپ-اِن
📦 16-PDIP
The verified data identifies the same INA2141 family and dual G = 10/100 instrumentation-amplifier function, but does not quantify a difference in offset, gain accuracy, temperature range, or gain-setting implementation.

📋 حوالہ جاتی متبادل (کیٹلاگ میں نہیں)

INA2141P زیادہ سے زیادہ ریٹنگز اور برقی خصوصیات

Product Type Dual instrumentation amplifier
Number of Amplifiers 2 circuits
Gain Settings 10 and 100
Supply Voltage Range ±2.25 V to ±18 V
Maximum Input Protection ±40 V
Offset Voltage 50 µV maximum
Offset Voltage Drift 0.5 µV/°C maximum
Gain Accuracy ±0.05% maximum
Input Bias Current 5 nA maximum
Common-Mode Rejection Ratio 117 dB minimum at G = 100
Bandwidth 200 kHz at G = 100
کوئیسینٹ کرنٹ 750 µA per amplifier
Input Architecture Current-feedback input circuitry
Internal Gain Configuration Laser-trimmed
پیکیج 16-pin plastic DIP (PDIP)
ماؤنٹنگ ٹائپ Through-hole

INA2141P 16-pin plastic dip (pdip) پن کنفیگریشن گائیڈ

INA2141P (16-pin plastic dip (pdip) پیکیج) کے لیے پن کنفیگریشن۔ اس اینالاگ کمپوننٹ میں اِن پٹ، آؤٹ پٹ اور پاور سپلائی پنز شامل ہیں۔ آفسیٹ نل، کمپنسیشن اور اِن ایبل پن کنفیگریشنز کے لیے مینوفیکچرر کے ڈیٹا شیٹ سے رجوع کریں۔ سگنل کنڈیشننگ اور ایمپلیفائر سرکٹس کے لیے مثالی۔

INA2141P کے لیے 16-pin plastic dip (pdip) پیکیج پن آؤٹ ڈایاگرام

کے لیے تفصیلی پن آؤٹ ڈیٹا دستیاب نہیں INA2141P.

رجوع کریں ڈیٹا شیٹ مکمل پن کنفیگریشن کے لیے۔

عام استعمالات

INA2141P کے لیے موزوں ہے 6 ایپلیکیشنs: Bridge Sensor Signal Conditioning, Industrial Process Measurement, Medical Monitoring Front End, Battery-Powered Portable Instrument, Current and Voltage Loop Sensing, Laboratory and Test Equipment.

🏭

Bridge Sensor Signal Conditioning

The INA2141P fits strain-gauge, pressure-transducer, and resistive bridge interfaces because each channel provides a gain of 10 or 100, offset voltage of 50 µV maximum, and offset drift of 0.5 µV/°C maximum. Place the bridge excitation across the amplifier input network and use the amplifier output for excitation-level error rejection and low-level differential-signal amplification. The dual configuration also allows a second channel to monitor a reference bridge or temperature signal. Verify the common-mode range at the selected gain, because bridge excitation can move the input voltage close to the supply rails.

🏭

Industrial Process Measurement

The INA2141P supports low-level process signals when the source is differential and common-mode noise must be rejected. Its 117 dB minimum CMRR at G = 100 helps suppress shared interference on paired sensor wires, while the current-feedback input stage preserves 200 kHz bandwidth at the higher gain. Use the two internal amplifiers for redundant sensing or for measuring a differential signal plus a complementary channel. In industrial cabinets, check the actual common-mode voltage and keep input protection needs separate from signal-bandwidth requirements.

💊

Medical Monitoring Front End

The INA2141P can condition low-amplitude differential sensor signals in medical monitoring equipment where offset and common-mode rejection are important. A gain of 10 suits relatively large physiological signals, while gain 100 provides additional amplification for smaller transducers with a suitable common-mode range. The dual-channel architecture can process two sensing inputs without using separate amplifier packages. Medical designs still require application-specific safety analysis, input limiting, isolation strategy, and compliance review; the amplifier's specified input protection should not be treated as complete patient protection.

📱

Battery-Powered Portable Instrument

The INA2141P is appropriate for portable, battery-powered instrumentation because the manufacturer specifies approximately 750 µA of quiescent current per amplifier and operation from ±2.25 V supplies. Its two amplifiers can handle two channels in one through-hole package, reducing component count where acceptable. The 50 µV maximum offset also limits the error introduced into small sensor outputs at low signal levels. For a compact battery design, verify whether a surface-mount orderable variant or a lower-power instrumentation amplifier is required after accounting for board-area constraints.

⚡

Current and Voltage Loop Sensing

The INA2141P can amplify the small differential voltage developed across a current-sense element when the common-mode voltage remains within the device's allowed range. Gain 100 increases the measurement resolution for low-value shunt drops, and the 117 dB minimum CMRR at that gain helps reject noise common to both shunt terminals. The input-protection capability reaches ±40 V, but it should not be relied upon as the primary surge-protection element. Carefully analyze headroom, shunt placement, Kelvin routing, and the amplifier's output-swing limits.

🔧

Laboratory and Test Equipment

The INA2141P is useful in laboratory front ends that measure weak differential outputs while rejecting shared noise on test fixtures. Its two gain settings allow the same circuit architecture to cover both moderate and small signals, and laser trimming supports repeatability across channels. The 200 kHz bandwidth at G = 100 permits measurement of signals beyond static DC only, so higher-frequency applications still require attention to settling time and gain-bandwidth behavior. A 16-pin plastic DIP package also simplifies prototyping and socketed laboratory assemblies.

What is the INA2141P instrumentation amplifier?
The INA2141P is a dual, low-power instrumentation amplifier from Texas Instruments with two selectable gain settings of 10 and 100. According to the manufacturer INA2141 datasheet, it uses a three-op-amp architecture with current-feedback input circuitry, laser trimming, low offset voltage, and high common-mode rejection. The device is supplied in a 16-pin plastic DIP package and is intended for precision differential signal conditioning in industrial, medical, and low-power instrumentation systems.
What are the key specifications of INA2141P that engineers should know?
The INA2141P provides two amplifiers with gains of 10 or 100, offset voltage of 50 µV maximum, offset drift of 0.5 µV/°C maximum, gain accuracy of ±0.05% maximum, and common-mode rejection of 117 dB minimum at G = 100. The manufacturer datasheet also specifies 200 kHz bandwidth at G = 100, 750 µA quiescent current per amplifier, operation from ±2.25 V supplies, and input protection to ±40 V. These figures define its suitability for precision, low-power differential measurements.
What is the operating voltage of INA2141P?
The INA2141P operates with supply voltages as low as ±2.25 V and up to ±18 V, according to the manufacturer INA2141 datasheet. The dual amplifier draws approximately 750 µA of quiescent current per amplifier, allowing operation from low-voltage analog supplies. The actual usable input and output range also depends on the selected gain and common-mode voltage, so supply headroom must be checked for every application.
Where can I download the INA2141P datasheet PDF?
The official INA2141P datasheet PDF is available from the Texas Instruments product link at https://www.ti.com/lit/ds/symlink/ina2141.pdf. The document covers the INA2141 family, including the INA2141P 16-pin plastic DIP orderable variant. It provides the electrical characteristics, gain-selection details, input-protection information, typical performance curves, and application information needed for design verification.
Where can I find the INA2141P pinout?
The authoritative INA2141P pin configuration is shown in the pin-configuration section of the official Texas Instruments datasheet at https://www.ti.com/lit/ds/symlink/ina2141.pdf. The verified search results identify the package as a 16-pin plastic DIP, but they do not provide a complete numbered pin list. This page therefore leaves the pinout null rather than publishing unverified pin assignments; engineers should use the manufacturer diagram before PCB routing.
What is the offset voltage of INA2141P?
The INA2141P has a maximum input offset voltage of 50 µV and a maximum offset drift of 0.5 µV/°C, according to the manufacturer INA2141 datasheet. These specifications are particularly important for strain-gauge, bridge, and pressure-sensor interfaces where a small differential error could dominate the measurement. The device is laser trimmed to support accurate performance at its two fixed gain settings.
How much bandwidth does INA2141P provide at gain 100?
The INA2141P provides 200 kHz bandwidth at a gain of 100 because its current-feedback input circuitry maintains bandwidth at high gain. According to the manufacturer INA2141 datasheet, this bandwidth behavior distinguishes the device from approaches in which usable bandwidth falls sharply as closed-loop gain increases. It makes the amplifier suitable for sensors whose signals must be amplified without excessive bandwidth limitation.
What can replace INA2141P?
The closest verified same-family option is INA2141PA, which appears in DigiKey cross-reference results for INA2141P. However, the supplied cross-reference data does not establish the complete package termination, electrical ratings, or pin-for-pin compatibility of that candidate. No other same-package drop-in part was verified from the provided web data. Engineers should confirm the INA2141PA ordering table and pin configuration before treating it as a drop-in substitute.
Is INA2141P suitable for battery-powered instrumentation?
Yes, the INA2141P is suitable for battery-powered instrumentation because the manufacturer datasheet specifies approximately 750 µA of quiescent current per amplifier and operation from ±2.25 V supplies. Its dual-channel configuration also allows two measurements to be handled in one package. Actual battery life depends on the selected gain, sensor current, duty cycle, reference implementation, and the quiescent current of the remaining analog circuitry.
What is the INA2141P vs INA2141PA difference?
The INA2141PA is the closest same-family candidate identified in the supplied DigiKey cross-reference data for INA2141P. The verified snippets do not provide a parameter table comparing the two orderable variants, so their precise gain accuracy, temperature range, and termination differences cannot be confirmed here. Treat INA2141PA as a candidate rather than a confirmed drop-in replacement until the manufacturer ordering table, package drawing, and pin functions have been compared.
When should I choose INA2141P over another instrumentation amplifier?
Choose the INA2141P when the design needs two matched channels, fixed gains of 10 or 100, low offset, low power consumption, and a 16-pin through-hole package. Its 117 dB minimum CMRR at G = 100 and 200 kHz bandwidth at G = 100 suit precision industrial and sensor-measurement systems. Select another device when you require adjustable gain, a different footprint, wider bandwidth, bipolar output swing beyond the stated supply limits, or a smaller surface-mount package.
Is INA2141P suitable for bridge-sensor measurement?
The INA2141P is well matched to bridge-sensor measurement because it offers a gain of 10 or 100, 50 µV maximum offset, ±0.05% maximum gain accuracy, and 117 dB minimum CMRR at gain 100. According to the manufacturer INA2141 datasheet, the low offset and drift reduce errors in small differential bridge outputs. The ±40 V input protection is also useful for overload tolerance, although external clamping and application-specific safety analysis are still required.
Does INA2141P need external gain-setting resistors?
The INA2141P uses internally configured gains of 10 and 100, but the exact external resistor connections and gain-selection implementation must be followed from the manufacturer datasheet. The verified information confirms two fixed gain options and laser trimming for accurate gain, while also identifying gain-setting guidance as part of the application information. Do not infer the resistor arrangement from another instrumentation amplifier because internal topology and gain-selection methods differ between families.
What is the input protection rating of INA2141P?
The INA2141P inputs are protected to ±40 V according to the manufacturer INA2141 datasheet. This protection improves tolerance to accidental overloads and helps the amplifier survive input transients in industrial wiring environments. The rating does not replace a dedicated surge-protection network, and engineers should still verify that the actual input current, clamp structure, and application waveform remain within the device's absolute maximum conditions.
How much does INA2141P cost and is it in stock?
Current verified unit pricing and a dated stock quantity were not included in the supplied distributor data, so a confirmed price and lead time cannot be stated. DigiKey lists the INA2141P as a Texas Instruments instrumentation amplifier in a 16-pin plastic DIP package, while XAIPART pricing is quote- or order-based and therefore uses a back-order availability designation in structured data. Contact XAIPART for an as-of-2026-10-30 quotation, availability, and volume pricing.

کے لیے انجینئرنگ ریفرنس ڈیٹا INA2141P — موازنہ، ڈیزائن رہنمائی، اور تعمیل کی معلومات۔

انتخاب کی گائیڈ

Choose the INA2141P when the design needs a dual, low-power instrumentation amplifier with fixed gains of 10 or 100, 50 µV maximum offset, and 117 dB minimum CMRR at G = 100. Its 16-pin plastic DIP package is useful for through-hole prototypes, socketed laboratory equipment, and industrial assemblies that do not require a compact surface-mount footprint. The dual architecture is valuable when two related channels must be measured consistently. Consider INA2141PA only after confirming its orderable package and electrical differences against the manufacturer ordering table. Choose a different instrumentation amplifier when adjustable gain, bipolar output capability beyond the supply limits, narrower input common-mode range, higher bandwidth, lower noise, or a surface-mount package is essential. Do not select a substitute solely because it is described as an instrumentation amplifier; verify pin functions, gain-setting components, supply range, common-mode range, and protection behavior on the original PCB.

متبادلات کے ساتھ موازنہ

پیرامیٹر یہ پروڈکٹ INA2141PA
Package 16-PDIP 16-PDIP (candidate; verify manufacturer ordering table)
Brand Texas Instruments Texas Instruments
Amplifier Configuration Dual instrumentation amplifier Dual instrumentation amplifier
Gain Settings 10 and 100 10 and 100

اہم امتیازی خصوصیات

  • Two precision channels in one through-hole package (بمقابلہINA2141PA)
  • Low offset supports small-signal measurement (بمقابلہINA2141PA)
  • High common-mode rejection at the higher gain (بمقابلہINA2141PA)

ڈیزائن نوٹس

The verified operating range begins at ±2.25 V, so power-supply headroom must be checked before assuming that either fixed gain can be used with a low-voltage sensor. Place the supply bypass capacitors close to the positive and negative pins and keep return-current paths away from sensitive input traces. The datasheet specifies approximately 750 µA of quiescent current per amplifier, but total supply current also depends on output current, load impedance, and the application reference network.

Route the differential inputs as a closely coupled pair and avoid routing them parallel to switching-node edges or the high-current return path of the system. Gain accuracy and CMRR can be degraded by unequal input impedance, leakage, and unmatched traces even when the amplifier itself is accurate. Keep the gain-setting and reference components close to their associated pins where the manufacturer layout permits, and provide a quiet ground reference for the analog return current.

Do not treat the ±40 V input-protection rating as a substitute for external surge protection. Verify the absolute maximum input voltage under the actual fault condition, account for input clamp current, and add series resistance or dedicated clamps where needed. Also confirm that the signal's common-mode voltage remains valid at the selected gain of 10 or 100; a low offset specification cannot compensate for an input operating outside the linear common-mode range.

The current-feedback architecture maintains 200 kHz bandwidth at G = 100, but practical settling performance still depends on source impedance, feedback-network implementation, output loading, and the complete signal path. Do not infer small-signal bandwidth as the usable settling frequency for a step response. Validate the full gain-and-filter network with the selected sensor source impedance and include the amplifier's offset and drift in the end-to-end error budget.

تعمیل کی معلومات

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
لیڈ فری
Unknown
ہیلوجن فری
Unknown
کنفلیکٹ منرلز
Unknown

The supplied manufacturer and distributor snippets do not explicitly state RoHS, REACH, halogen-free, lead-free, conflict-minerals, or automotive qualification information. AEC-Q100 is treated as not applicable because no automotive qualification is stated for this orderable variant.

ڈیٹا کی تصدیق کی تاریخ: 2026-10-30 — ڈیٹا XAIPART کی کمپوننٹ انجینئرنگ ٹیم کے ذریعے تصدیق شدہ اور ترتیب شدہ

متعلقہ تلاشیں

INA2141P INA2141P datasheet Texas Instruments INA2141P INA2141P dual instrumentation amplifier INA2141P gain 10 gain 100 INA2141P 16-PDIP INA2141P bridge sensor amplifier INA2141P industrial process measurement INA2141P vs INA2141PA INA2141P drop-in replacement INA2141P price buy INA2141P online INA2141P pinout low power dual instrumentation amplifier 16-PDIP

متعلقہ اجزاء اور اصطلاحات

Texas Instruments INA2141P INA2141 INA2141PA Burr-Brown dual instrumentation amplifier instrumentation amplifier precision analog current-feedback input three-op-amp architecture common-mode rejection ratio CMRR gain accuracy input offset voltage offset voltage drift input bias current quiescent current input protection bridge sensor strain gauge industrial process measurement battery-powered instrumentation 16-pin plastic DIP through-hole package
فوری کوٹ RFQ
مکمل تفصیلات بھریں — ہماری سیلز ٹیم 24 گھنٹوں میں جواب دے گی
پارٹ نمبر مینوفیکچرر پیکج QTY ہدف قیمت کل رقم
✓
کوٹ جمع ہو گیا!

ہم 24 گھنٹوں کے اندر آپ کے ای میل کا جواب دیں گے

1
RFQ جمع ہو گیا
2
کوٹ موصول ہو گیا
3
آرڈر دے دیا گیا
4
ادائیگی
5
بھیج دیا گیا
6
ڈیلیور شدہ
RFQ تفصیلات دیکھیں