SI3056-D-FS - 3V Integrated Telephone DAA | Skyworks
MPN: SI3056-D-FS ✓ فعالSI3056-D-FS جائزہ
A Direct Access Arrangement is a telecom interface IC that connects a communications system to the physical telephone line. It belongs to the interface IC hierarchy and replaces discrete analog front-end, isolation-transformer, and related line-interface functions. The SI3056-D-FS provides a programmable line interface with integrated isolation technology, reducing the external circuitry needed for a compliant line-side connection.
Key features identified for the SI3056 family include AC termination, DC termination, ring-detect threshold, ringer impedance, and an 80 dB dynamic range across the transmit and receive paths. Its low 3 V supply requirement suits compact, low-voltage telephony designs, while 15 mA typical consumption helps constrain system power demand. The integrated approach can also reduce board area compared with a discrete implementation.
The SI3056 combines programmable line-interface functions, isolation technology, and transmit/receive signal handling in one 16-SOIC device. Its architecture is intended to provide a configurable line interface for global telephone equipment, including voice-over-IP terminals, analog telephone adapters, voice gateways, and other line-connected communications products. Exact electrical limits and timing values should be selected from the manufacturer datasheet.
Typical applications include legacy telephone-network interfaces, Voice over IP endpoint equipment, customer premises equipment, voice gateways, and embedded telephone-line adapters. The 80 dB dynamic range is relevant when preserving voice-band signal amplitude across the transmit and receive paths, while programmable termination and ring-detection functions allow the same device family to address different line conditions.
Designers should use the manufacturer pin-description table when assigning the 16-SOIC land pattern and should review the application circuit for recommended external components. Power routing should minimize noise on the telephone-line interface, and isolation-related creepage and clearance requirements should be evaluated against the final PCB construction and system voltage.
This product page combines the SI3056-D-FS device identity, electrical highlights, package information, application guidance, drop-in options, and design notes. It supports faster component evaluation while directing detailed implementation decisions to the manufacturer datasheet and its prescribed reference circuit.
کے لیے ڈراپ اِن متبادل SI3056-D-FS — یکساں پیکیج، پن سے پن مطابقت پذیر۔ مختلف پیکیج والے پرزے جن کے لیے PCB دوبارہ کام درکار ہو، شامل نہیں ہیں۔
اس سیریز میں مختلف ورژن
اسی سیریز کے ماڈلز جو ڈراپ اِن مطابقت رکھتے ہیں SI3056-D-FS (یکساں فارم فیکٹر اور فٹ پرنٹ) — میں مختلف Isolation Technology, Package, Product Type.
SI3056-D-FSR
✅ ڈراپ-اِن📋 حوالہ جاتی متبادل (کیٹلاگ میں نہیں)
SI3056-FS
✅ ڈراپ-اِنقیمت کے لیے رابطہ کریں
ڈیٹا شیٹ دیکھیں →SI3056-D-FS تفصیلات
| Product Type | Direct Access Arrangement (DAA) |
| Minimum Supply Voltage | 3 V |
| Typical Supply Current | 15 mA |
| Dynamic Range | 80 dB |
| انٹرفیس | Global Serial Interface (GSI) |
| پیکیج | 16-SOIC |
| ماؤنٹنگ ٹائپ | Surface Mount |
| AC Termination | Integrated |
| DC Termination | Integrated |
| Ring Detection | Programmable ring-detect threshold |
| Ringer Impedance | Programmable ringer impedance |
| Isolation Technology | Integrated Skyworks isolation technology |
| Transmit and Receive Paths | Integrated TX/RX paths |
SI3056-D-FS 16-soic پن کنفیگریشن گائیڈ
SI3056-D-FS (16-soic پیکیج) کے لیے پن کنفیگریشن۔ پن نمبرنگ، فنکشنز اور کنکشن ڈایاگرامز مینوفیکچرر کے ڈیٹا شیٹ میں بیان کیے گئے ہیں۔ درست فٹ پرنٹ اور سولڈرنگ رہنما ہدایات کے لیے اسی سے رجوع کریں۔
کے لیے تفصیلی پن آؤٹ ڈیٹا دستیاب نہیں SI3056-D-FS.
رجوع کریں ڈیٹا شیٹ مکمل پن کنفیگریشن کے لیے۔
عام استعمالات
SI3056-D-FS کے لیے موزوں ہے 6 ایپلیکیشنs: Voice over IP Telephone Adapters, Analog Voice Terminals, Customer Premises Equipment, Voice Gateways, Embedded Telephone-Line Adapters, Legacy Network Interface Modules.
Voice over IP Telephone Adapters
The SI3056-D-FS fits Voice over IP adapters that must connect digital voice equipment to a physical telephone line. Its integrated Direct Access Arrangement combines AC termination, DC termination, ring detection, ringer impedance, and transmit and receive paths in a 16-SOIC package. Operating from a 3 V minimum supply and drawing 15 mA typical current supports compact, power-conscious endpoint designs. The 80 dB dynamic range across the TX/RX paths is useful for preserving voice-band signal amplitude. Designers should implement the isolation and external-network components shown in the manufacturer application circuit, since the integrated device does not eliminate all line-interface requirements.
Analog Voice Terminals
The SI3056-D-FS is appropriate for analog voice terminals requiring a configurable telephone-line connection. Programmable AC and DC termination, ring-detect threshold, and ringer impedance allow the same DAA architecture to support different line-network conditions. Its 16-SOIC package limits board area compared with a larger discrete line-interface implementation, while the 3 V minimum supply and 15 mA typical current are suitable for low-voltage terminal platforms. The 80 dB dynamic range helps maintain signal integrity through the integrated transmit and receive paths. Final implementations must follow the manufacturer isolation and external-component recommendations.
Customer Premises Equipment
The SI3056-D-FS can support legacy telephone connectivity within customer premises equipment such as gateways and access terminals. Its integrated DAA replaces a collection of analog front-end and isolation-related discrete functions, simplifying the line-interface layout. The 3 V minimum operating supply supports compact CPE power architectures, and the 15 mA typical current helps designers establish a realistic supply budget. Programmable line termination and ring detection are particularly useful when equipment must operate across different telephone-line configurations. Engineers should still verify regulatory isolation, surge protection, PCB creepage, and external impedance requirements for the deployed region.
Voice Gateways
The SI3056-D-FS suits voice gateways that bridge packet-based calling systems with legacy telephone lines. The integrated DAA provides a programmable physical line interface, including AC termination, DC termination, ring detection, and ringer-impedance control, while the transmit and receive paths support voice-band signal handling with 80 dB dynamic range. Its 16-SOIC package is useful where gateway hardware must combine analog line connectivity with dense digital processing. The 3 V minimum supply and 15 mA typical consumption support power budgeting in embedded systems. Keep the telephone interface isolated from user-facing circuits and follow the manufacturer layout guidance for high-voltage separation.
Embedded Telephone-Line Adapters
The SI3056-D-FS fits embedded adapters used to add telephone-line connectivity to industrial or communications equipment. Integrating the analog front end, isolation-transformer-related functions, transmit path, and receive path reduces the number of discrete line-interface components and simplifies assembly. The 16-SOIC package provides a compact footprint, and the 3 V minimum supply permits integration with low-voltage system rails. The programmable termination and ring-detection functions allow a standard platform to address multiple line conditions, while the 80 dB dynamic range supports voice transmission. Qualification should include line-network, isolation, temperature, and protection testing appropriate to the deployed equipment.
Legacy Network Interface Modules
The SI3056-D-FS can be used in legacy network interface modules where an embedded system requires direct access to a telephone line. Its system-side SSI interface and programmable DAA functions provide a controlled connection between the host processor and the physical line. A 3 V minimum supply and 15 mA typical current make the device suitable for compact embedded power systems, while the 80 dB dynamic range covers the integrated TX/RX paths. The same 16-SOIC device also supports ring sensing and programmable termination, reducing external circuitry. Designers should confirm SSI timing and pin-level behavior in the manufacturer datasheet before laying out the host interface.
کے لیے انجینئرنگ ریفرنس ڈیٹا SI3056-D-FS — موازنہ، ڈیزائن رہنمائی، اور تعمیل کی معلومات۔
انتخاب کی گائیڈ
متبادلات کے ساتھ موازنہ
| پیرامیٹر | یہ پروڈکٹ | SI3056-D-FSR | SI3056-FS |
|---|---|---|---|
| Package | 16-SOIC | 16-SOIC | 16-SOIC |
| Brand | Skyworks Solutions | Skyworks Solutions | Skyworks Solutions |
| Product Type | Direct Access Arrangement (DAA) | Direct Access Arrangement (DAA) | Direct Access Arrangement (DAA) |
| Ordering Difference | SI3056-D-FS system-side DAA ordering code | Reel-oriented ordering code | SI3056-FS ordering code |
اہم امتیازی خصوصیات
- Maintains the same documented system-side DAA configuration (بمقابلہSI3056-D-FSR)
- Uses the same physical SOIC footprint (بمقابلہSI3056-FS)
- Integrates multiple telephone-line functions (بمقابلہSI3056-D-FSR)
ڈیزائن نوٹس
Follow the manufacturer application circuit and pin-description table when placing the 16-SOIC device. Keep the telephone-line interface and isolation barrier layout separated from low-voltage host circuitry, and preserve the recommended clearance and creepage boundaries. Decoupling components should connect directly to the relevant supply and ground pins with short traces so switching and line-transient energy does not enter sensitive host circuits.
Budget the power path using the 15 mA typical supply current and a 3 V minimum operating supply before adding margin for startup, transient, and line-dependent behavior. Use a local regulator or supply node that remains within the manufacturer limits. Verify that adjacent converters and switching nodes are arranged so their radiated or conducted noise does not degrade the 80 dB TX/RX dynamic range of the DAA.
Do not assume that any 16-SOIC Direct Access Arrangement is electrically interchangeable. Compare the exact ordering code, SSI interface behavior, ring-detection threshold, ringer impedance, termination configuration, and isolation implementation. When moving from SI3056-D-FS to SI3056-D-FSR, confirm reel orientation and assembly requirements; when considering SI3056-FS, verify the suffix-specific configuration before releasing production artwork.
تعمیل کی معلومات
The SI3056-D-FS is a telecommunications interface IC, so AEC-Q100 automotive qualification is not applicable. RoHS, REACH, lead-free, halogen-free, and conflict-minerals status were not stated in the device documentation excerpt.