Analog Devices

VSC7153SS-02 - 24-PHY 3Gbps SAS Expander | Analog Devices

MPN: VSC7153SS-02 ✓ فعال
MOQ: 1 |

VSC7153SS-02 جائزہ

Analog Devices VSC7153SS-02 is a SAS edge and fanout expander with 24 PHYs, support for 1.5 Gbps and 3.0 Gbps SAS signaling, table routing, and an SSP engine. The device is designed to consolidate and route SAS link traffic across storage systems where endpoint density, expandability, and deterministic internal routing are important. Its multi-PHY architecture makes it suitable for SAS backplane, storage-controller, and enclosure-management designs.

A SAS expander is a semiconductor that sits between SAS initiator and target devices, providing multiple physical link connections and managed routing between them. Within the broader hierarchy, it is an interface controller, then a networking interface IC, then an integrated circuit and semiconductor. Compared with point-to-point passive switching, an expander can monitor links, respond to management requests, and route traffic through a controlled topology.

The three headline characteristics of the VSC7153SS-02 are its 24 physical-layer interfaces, support for SAS link rates of 1.5 Gbps and 3.0 Gbps, and integrated table-routing and SSP-engine functions. These features allow one fabric component to consolidate numerous SAS links while providing a structured path for discoverability and topology management. The exact package dimensions, pin assignments, power ratings, operating temperature range, and lifecycle classifications must be confirmed in the family documentation before layout release.

Technically, the device belongs to the application-specific controller category rather than a general-purpose microcontroller. Each PHY provides the physical signaling endpoint for a SAS connection, while the expander logic manages communication among initiator, target, and expander devices. Table routing defines how logical paths are organized, and the SSP engine supports Serial SCSI Protocol functions used for discovery and management. This combination is valuable when a system needs more fanout than a direct initiator-to-target arrangement can provide.

Typical uses include 24-bay SAS storage enclosures, SAS backplane expanders, redundant storage arrays, and embedded server or workstation storage controllers. In these applications, the 24-PHY count can reduce the number of discrete routing and fanout elements while preserving individual SAS connectivity for attached disks. The 1.5 Gbps and 3.0 Gbps rates support deployments spanning legacy 3 Gbit/s SAS environments as well as newer 6 Gbit/s SAS links when the complete link path is compatible.

Design planning should begin with the manufacturer's pin-description table, power architecture, reference clock requirements, and recommended decoupling network. Board-level validation must also cover SAS signal integrity, connector and cable compatibility, PHY-to-PHY routing, thermal margin, and the power-sequencing requirements of the complete storage subsystem. Do not infer exposed-pad or thermal-pad connections from the orderable suffix; verify them directly against the relevant package drawing and pinout.

This product page distinguishes the confirmed VSC7153-02 family capabilities from orderable-package details that require separate validation. It also organizes sourcing questions, functional use cases, design cautions, and comparison requirements into an engineering-focused reference for storage-interface developers evaluating the VSC7153SS-02.

کے لیے ڈراپ اِن متبادل VSC7153SS-02 — یکساں پیکیج، پن سے پن مطابقت پذیر۔ مختلف پیکیج والے پرزے جن کے لیے PCB دوبارہ کام درکار ہو، شامل نہیں ہیں۔

اس سیریز میں مختلف ورژن

اسی سیریز کے ماڈلز جو ڈراپ اِن مطابقت رکھتے ہیں VSC7153SS-02 (یکساں فارم فیکٹر اور فٹ پرنٹ).

VSC7153XSS-02

✅ ڈراپ-اِن
Analog Devices
📦 [DATA_NEEDED: Package]
SAS edge/fanout expander · 24 PHY · 1.5 Gbps · 3.0 Gbps · Table routing · SSP engine · IC interface controller · SAS edge/fanout expansion

قیمت کے لیے رابطہ کریں

ڈیٹا شیٹ دیکھیں →

VSC7153SS-02 تفصیلات

Device Type SAS edge/fanout expander
Number of PHYs 24 PHYs
SAS Link Rate Support 1.5 Gbps and 3.0 Gbps
Routing Architecture Table routing
Protocol Engine SSP engine
Product Family VSC7153-02
Manufacturer Analog Devices / Maxim Integrated
Maximum SAS Link Rate 3.0 Gbps

VSC7153SS-02 standard پن کنفیگریشن گائیڈ

VSC7153SS-02 (standard پیکیج) کے لیے پن کنفیگریشن۔ پن نمبرنگ، فنکشنز اور کنکشن ڈایاگرامز مینوفیکچرر کے ڈیٹا شیٹ میں بیان کیے گئے ہیں۔ درست فٹ پرنٹ اور سولڈرنگ رہنما ہدایات کے لیے اسی سے رجوع کریں۔

VSC7153SS-02 کے لیے standard پیکیج پن آؤٹ ڈایاگرام

کے لیے تفصیلی پن آؤٹ ڈیٹا دستیاب نہیں VSC7153SS-02.

رجوع کریں ڈیٹا شیٹ مکمل پن کنفیگریشن کے لیے۔

عام استعمالات

VSC7153SS-02 کے لیے موزوں ہے 6 ایپلیکیشنs: 24-Bay SAS Storage Enclosure, SAS Backplane Expander, Redundant Enterprise Storage Array, Embedded Storage Controller, SAS Edge Expansion in Legacy Systems, SAS Management and Discovery Fabric.

🖥️

24-Bay SAS Storage Enclosure

The VSC7153SS-02 fits a high-density SAS enclosure where one fabric device must coordinate as many as 24 physical links. Its 24 PHYs allow each attached drive path to remain an individual SAS connection while table routing manages traffic through the internal topology. The 1.5 Gbps and 3.0 Gbps rate options support legacy and newer SAS paths, provided every initiator, expander, target, connector, and cable in the active path is rated for the selected link rate. Design validation should cover power-loss behavior, discovery, thermal margin, and the exact package pinout before production release.

🌐

SAS Backplane Expander

A SAS backplane can use the VSC7153SS-02 as the central routing and fanout element rather than relying on a collection of simpler point-to-point switches. The 24-PHY configuration supports high connector density, while the table-routing and SSP-engine functions provide the logic needed for discovery and managed paths. Engineers should evaluate signal integrity across connector and cable transitions, provide clean reference-clock and supply networks, and confirm whether the intended backplane topology requires redundant fabric or management paths not included in the base design.

🏭

Redundant Enterprise Storage Array

The VSC7153SS-02 can contribute to the SAS fabric of an enterprise storage array where numerous disk paths must be consolidated behind an initiator. Its support for 1.5 Gbps and 3.0 Gbps allows mixed system architectures to be considered during migration periods, although each individual link remains constrained by its slowest participating device. Table routing and the SSP engine support managed discovery across the fabric. Redundant designs must add explicit failover, power, and path-monitoring requirements rather than assuming that a single expander automatically provides high availability.

🔧

Embedded Storage Controller

The VSC7153SS-02 is applicable when an embedded controller needs to fan out a SAS connection to multiple targets while maintaining a manageable device topology. Twenty-four PHYs provide substantial endpoint density without requiring an equivalent number of separate interface devices. This can simplify board partitioning and topology management in industrial servers, test systems, and specialized processing platforms. The implementation must be checked against the controller's SAS initiation capabilities, operating-system or storage-stack support, reference-clock architecture, and the exact electrical limits of the selected package.

📺

SAS Edge Expansion in Legacy Systems

The VSC7153SS-02 can bridge a legacy 1.5 Gbps SAS environment into a fabric that also contains 3.0 Gbps paths, subject to link negotiation and end-device support. This makes it relevant to storage upgrades where controllers and disks operate at different generations but still share compatible SAS infrastructure. The expander must be configured and validated with the complete initiator, target, and management stack. Engineers should confirm per-link fallback behavior, discovery through the SSP engine, and whether the enclosure's connectors and cables preserve adequate signal margin at the intended distance.

💡

SAS Management and Discovery Fabric

The table-routing and SSP-engine functions make the VSC7153SS-02 relevant to managed SAS fabrics in which controllers must discover target devices and maintain topology information. The 24-PHY count allows numerous links to participate in one managed fabric while reducing separate switching complexity. For appliance designs, verify the management transport, configuration persistence behavior, firmware compatibility, and supported operating systems. A laboratory validation should exercise discovery after cold start, controller reset, expander reset, target replacement, and link-speed transitions before the design is released to storage enclosures.

What is the VSC7153SS-02?
The VSC7153SS-02 is a 24-PHY SAS edge and fanout expander from Analog Devices, formerly associated with Maxim Integrated. According to the manufacturer family datasheet identified as VSC7153-02, it supports SAS signaling at 1.5 Gbps and 3.0 Gbps and includes table-routing and SSP-engine functions. It is intended for storage fabrics that need multiple SAS physical links and managed connectivity.
How many SAS PHYs does the VSC7153SS-02 provide?
The VSC7153SS-02 provides 24 SAS PHYs. The VSC7153-02 manufacturer datasheet identifies the device as a 24-PHY SAS edge/fanout expander, with one physical-layer endpoint for each supported SAS link. This density makes the part applicable to storage enclosures, backplanes, and expanders requiring numerous individual SAS connections in a single switching component.
What SAS data rates are supported by the VSC7153SS-02?
The VSC7153SS-02 supports SAS link rates of 1.5 Gbps and 3.0 Gbps. According to the VSC7153-02 manufacturer datasheet, these rates correspond to 3 Gbit/s and 6 Gbit/s SAS signaling respectively. A complete storage link must support the selected rate, including the initiator, expander, target, connector, cable, and signal-integrity channel.
Where can I download the VSC7153SS-02 datasheet PDF?
The VSC7153SS-02 datasheet can be located through the Alldatasheet search result linked on this page, which identifies the underlying document as the VSC7153-02 family datasheet. Use the manufacturer's pin-description table, electrical characteristics, and package drawing for design release. The orderable suffix must also be checked so that the selected package and temperature variant match the intended assembly.
Where can I find the VSC7153SS-02 pinout?
The VSC7153SS-02 pin assignments must be taken from the pin-description table in the VSC7153-02 family datasheet and the drawing for the exact SS orderable suffix. Do not infer the pin count or exposed connections from the MPN alone. Use the package drawing to assign supply, ground, reference-clock, reset, serial-management, and SAS differential I/O connections before releasing the PCB layout.
Is the VSC7153SS-02 suitable for a SAS storage backplane?
The VSC7153SS-02 is suitable for many SAS storage-backplane and enclosure-fanout designs because it provides 24 PHYs, supports 1.5 Gbps and 3.0 Gbps links, and includes table routing plus an SSP engine. Final suitability depends on link budget, connector and cable characteristics, supported device count, topology rules, thermal performance, and the exact power and package requirements in the family datasheet.
Can the VSC7153SS-02 be used in a 24-bay SAS enclosure?
The VSC7153SS-02 can serve as the central SAS fabric device in a 24-bay enclosure because its 24 PHYs provide dedicated SAS physical connections for a high-density topology. The designer must still account for initiator connections, expander-to-target links, power-loss behavior, management access, and any additional path needed for redundancy. The 1.5 Gbps and 3.0 Gbps rate support should match every device in each active path.
What is the difference between SAS edge and SAS fanout operation?
SAS edge operation connects an initiator to a switch or expander that reaches multiple targets, while SAS fanout describes the expander-to-target connectivity used to distribute links from that edge. The VSC7153SS-02 supports both roles within a SAS fabric through its 24 PHYs, table-routing functions, and SSP engine. The final topology and discovery behavior should be validated in the manufacturer's system documentation.
When should I choose the VSC7153SS-02 over another SAS expander?
Choose the VSC7153SS-02 when the design requires a high-density SAS fabric with 24 PHYs and operation at 1.5 Gbps or 3.0 Gbps. Selection should also require compatible table-routing and SSP-engine behavior. If a competing device offers a different PHY count, link-rate ceiling, management interface, package, or power rating, verify those differences rather than assuming functional interchangeability.
Is the VSC7153SS-02 a direct replacement for VSC7153XSS-02?
The VSC7153SS-02 and VSC7153XSS-02 are distinct orderable MPNs, and their exact interchangeability cannot be assumed from the family relationship alone. A valid replacement requires the same package, lead pattern, electrical ratings, clocking, management interface, firmware requirements, and SAS behavior. Review the manufacturer part tables and package drawings before substituting one MPN for the other.
What can replace the VSC7153SS-02?
A direct replacement for the VSC7153SS-02 must use the same pin-compatible package and provide at least 24 SAS PHYs, 1.5 Gbps and 3.0 Gbps link support, and compatible table-routing and SSP functions. No verified drop-in replacement is identified for this exact orderable MPN. Compare the manufacturer datasheet, package drawing, electrical limits, management interface, and firmware dependencies before approving any substitute.
What are the key specifications of the VSC7153SS-02?
The key confirmed specifications are 24 SAS PHYs, support for 1.5 Gbps and 3.0 Gbps link rates, table routing, and an SSP engine. The device is identified as an Analog Devices/Maxim Integrated SAS edge and fanout expander in the VSC7153-02 family documentation. Supply voltage, operating temperature, power consumption, package dimensions, and exact pin count remain essential release-stage checks.
How much power does the VSC7153SS-02 consume?
The exact power consumption of the VSC7153SS-02 cannot be stated without the electrical-characteristics table for the exact orderable variant and operating condition. Evaluate it using the manufacturer datasheet's supply voltage, SAS activity, PHY utilization, and thermal data. Request current lead time, minimum order quantity, and lifecycle confirmation through the Request a Quote form on this page.
Where can I buy the VSC7153SS-02 online?
Use the Request a Quote form on this page to request the VSC7153SS-02 from XAIPART, including quantity, package, target date, and shipment requirements. The form is the appropriate route for current commercial availability because inventory and lead time can change rapidly. No fixed price or stock commitment should be inferred from a listing page.
What is the lead time and stock status for the VSC7153SS-02?
Current lead time, minimum order quantity, and stock status for the VSC7153SS-02 should be confirmed through the Request a Quote form on this page. Include your required quantity, production schedule, and packaging needs in the request. These commercial conditions are time-dependent and cannot be reliably represented by a static product value.

کے لیے انجینئرنگ ریفرنس ڈیٹا VSC7153SS-02 — موازنہ، ڈیزائن رہنمائی، اور تعمیل کی معلومات۔

انتخاب کی گائیڈ

Choose the VSC7153SS-02 for a managed SAS fabric that requires 24 PHYs, 1.5 Gbps and 3.0 Gbps link operation, table routing, and SSP-engine functionality. It is particularly relevant to dense storage enclosures, SAS backplanes, and embedded controllers where individual target paths must remain addressable through a managed topology. Before committing to the device, verify its exact package, power requirements, clocking, environmental ratings, and management interfaces against the design. A family-related variant may differ in package, temperature grade, or supported features and therefore should not be treated as interchangeable without a pin- and function-level review. If fewer links are required, a lower-density expander may simplify power and board cost; if a design exceeds 24 physical connections, it may require multiple expanders or a different architecture. For migration systems, confirm that every initiator, target, connector, and cable supports the selected SAS rate.

متبادلات کے ساتھ موازنہ

پیرامیٹر یہ پروڈکٹ
Manufacturer Analog Devices / Maxim Integrated
Device Type SAS edge/fanout expander
Number of PHYs 24 PHYs
Supported SAS Link Rates 1.5 Gbps and 3.0 Gbps
Routing Architecture Table routing
Protocol Engine SSP engine

ڈیزائن نوٹس

Assign the VSC7153SS-02 SAS pins strictly from the pin-description table for the exact SS orderable suffix. Keep each differential SAS pair routed with continuous reference-plane support, matched impedance, and minimized stubs. Avoid placing incompatible circuitry between the expander and backplane connectors, and use the manufacturer's recommended layer stack and via geometry so that 3.0 Gbps operation is not limited by avoidable discontinuities.

Confirm the supply voltage, supply-current limits, sequencing, and decoupling recommendations in the VSC7153-02 electrical-characteristics table before power-distribution design. Place required bulk and high-frequency bypass capacitance close to the device's power and ground pins, preserve a low-impedance return path, and account for transients generated during SAS link training. Do not infer an exposed-pad connection or supply arrangement from the MPN suffix.

Validate the complete path from the expander through connectors and cables to the attached SAS device, rather than testing only the IC pins. Use the manufacturer's reference clock, termination, and topology guidance where specified, and check receiver and transmitter margins with representative 1.5 Gbps and 3.0 Gbps traffic. Include worst-case cable length, connector loss, adjacent-port coupling, and transition effects in simulation and system measurements.

Do not treat a family-related MPN as a drop-in substitute without checking package drawings, pin names, clock requirements, management interfaces, firmware dependencies, and absolute maximum ratings. Likewise, do not infer a 24-bay deployment solely from the 24-PHY count: initiator links, redundancy, path topology, power-loss behavior, and supported discovery methods can reduce the usable disk count. Confirm these constraints in the family documentation.

تعمیل کی معلومات

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
لیڈ فری
Unknown
ہیلوجن فری
Unknown
کنفلیکٹ منرلز
Unknown

Compliance status is not stated for this orderable MPN. Check the manufacturer product page, current datasheet, and declaration documents for the exact package and ordering option.

ڈیٹا کی تصدیق کی تاریخ: 2026-11-11 — ڈیٹا XAIPART کی کمپوننٹ انجینئرنگ ٹیم کے ذریعے تصدیق شدہ اور ترتیب شدہ

متعلقہ تلاشیں

VSC7153SS-02 datasheet VSC7153SS-02 pinout VSC7153SS-02 datasheet pdf VSC7153SS-02 equivalent VSC7153SS-02 replacement VSC7153SS-02 cross reference VSC7153SS-02 footprint VSC7153SS-02 schematic VSC7153 24 PHY SAS expander VSC7153SS-02 application circuit VSC7153SS-02 price VSC7153SS-02 stock Analog Devices VSC7153SS-02

متعلقہ اجزاء اور اصطلاحات

Analog Devices Maxim Integrated VSC7153SS-02 VSC7153-02 SAS expander SAS edge SAS fanout Serial SCSI Protocol SSP engine table routing interface controller integrated circuit semiconductor 24-PHY 1.5 Gbps SAS 3.0 Gbps SAS storage enclosure SAS backplane storage controller link training differential pair reference clock surface-mount package
فوری کوٹ RFQ
مکمل تفصیلات بھریں — ہماری سیلز ٹیم 24 گھنٹوں میں جواب دے گی
پارٹ نمبر مینوفیکچرر پیکج QTY ہدف قیمت کل رقم
✓
کوٹ جمع ہو گیا!

ہم 24 گھنٹوں کے اندر آپ کے ای میل کا جواب دیں گے

1
RFQ جمع ہو گیا
2
کوٹ موصول ہو گیا
3
آرڈر دے دیا گیا
4
ادائیگی
5
بھیج دیا گیا
6
ڈیلیور شدہ
RFQ تفصیلات دیکھیں