VSC7153SS-02 - 24-PHY 3Gbps SAS Expander | Analog Devices
부품 번호: VSC7153SS-02 ✓ 활성VSC7153SS-02 개요
A SAS expander is a semiconductor that sits between SAS initiator and target devices, providing multiple physical link connections and managed routing between them. Within the broader hierarchy, it is an interface controller, then a networking interface IC, then an integrated circuit and semiconductor. Compared with point-to-point passive switching, an expander can monitor links, respond to management requests, and route traffic through a controlled topology.
The three headline characteristics of the VSC7153SS-02 are its 24 physical-layer interfaces, support for SAS link rates of 1.5 Gbps and 3.0 Gbps, and integrated table-routing and SSP-engine functions. These features allow one fabric component to consolidate numerous SAS links while providing a structured path for discoverability and topology management. The exact package dimensions, pin assignments, power ratings, operating temperature range, and lifecycle classifications must be confirmed in the family documentation before layout release.
Technically, the device belongs to the application-specific controller category rather than a general-purpose microcontroller. Each PHY provides the physical signaling endpoint for a SAS connection, while the expander logic manages communication among initiator, target, and expander devices. Table routing defines how logical paths are organized, and the SSP engine supports Serial SCSI Protocol functions used for discovery and management. This combination is valuable when a system needs more fanout than a direct initiator-to-target arrangement can provide.
Typical uses include 24-bay SAS storage enclosures, SAS backplane expanders, redundant storage arrays, and embedded server or workstation storage controllers. In these applications, the 24-PHY count can reduce the number of discrete routing and fanout elements while preserving individual SAS connectivity for attached disks. The 1.5 Gbps and 3.0 Gbps rates support deployments spanning legacy 3 Gbit/s SAS environments as well as newer 6 Gbit/s SAS links when the complete link path is compatible.
Design planning should begin with the manufacturer's pin-description table, power architecture, reference clock requirements, and recommended decoupling network. Board-level validation must also cover SAS signal integrity, connector and cable compatibility, PHY-to-PHY routing, thermal margin, and the power-sequencing requirements of the complete storage subsystem. Do not infer exposed-pad or thermal-pad connections from the orderable suffix; verify them directly against the relevant package drawing and pinout.
This product page distinguishes the confirmed VSC7153-02 family capabilities from orderable-package details that require separate validation. It also organizes sourcing questions, functional use cases, design cautions, and comparison requirements into an engineering-focused reference for storage-interface developers evaluating the VSC7153SS-02.
드롭인 대체품: VSC7153SS-02 — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.
이 시리즈의 변형
다음과 드롭인 호환되는 동일 시리즈 모델: VSC7153SS-02 (동일 폼 팩터 및 풋프린트).
VSC7153XSS-02
✅ 드롭인가격 문의
데이터시트 보기 →VSC7153SS-02 사양
| Device Type | SAS edge/fanout expander |
| Number of PHYs | 24 PHYs |
| SAS Link Rate Support | 1.5 Gbps and 3.0 Gbps |
| Routing Architecture | Table routing |
| Protocol Engine | SSP engine |
| Product Family | VSC7153-02 |
| Manufacturer | Analog Devices / Maxim Integrated |
| Maximum SAS Link Rate | 3.0 Gbps |
VSC7153SS-02 standard 핀 구성 가이드
VSC7153SS-02(standard 패키지)의 핀 구성입니다. 핀 번호, 기능, 연결 다이어그램은 제조사 데이터시트에 정의되어 있습니다. 정확한 풋프린트와 솔더링 지침은 해당 문서를 참조하십시오.
다음에 대한 상세 핀아웃 데이터 없음: VSC7153SS-02.
다음을 참조하십시오: 데이터시트 전체 핀 구성은 다음을 참조하십시오.
일반적인 애플리케이션
VSC7153SS-02 적합 용도: 6 애플리케이션s: 24-Bay SAS Storage Enclosure, SAS Backplane Expander, Redundant Enterprise Storage Array, Embedded Storage Controller, SAS Edge Expansion in Legacy Systems, SAS Management and Discovery Fabric.
24-Bay SAS Storage Enclosure
The VSC7153SS-02 fits a high-density SAS enclosure where one fabric device must coordinate as many as 24 physical links. Its 24 PHYs allow each attached drive path to remain an individual SAS connection while table routing manages traffic through the internal topology. The 1.5 Gbps and 3.0 Gbps rate options support legacy and newer SAS paths, provided every initiator, expander, target, connector, and cable in the active path is rated for the selected link rate. Design validation should cover power-loss behavior, discovery, thermal margin, and the exact package pinout before production release.
SAS Backplane Expander
A SAS backplane can use the VSC7153SS-02 as the central routing and fanout element rather than relying on a collection of simpler point-to-point switches. The 24-PHY configuration supports high connector density, while the table-routing and SSP-engine functions provide the logic needed for discovery and managed paths. Engineers should evaluate signal integrity across connector and cable transitions, provide clean reference-clock and supply networks, and confirm whether the intended backplane topology requires redundant fabric or management paths not included in the base design.
Redundant Enterprise Storage Array
The VSC7153SS-02 can contribute to the SAS fabric of an enterprise storage array where numerous disk paths must be consolidated behind an initiator. Its support for 1.5 Gbps and 3.0 Gbps allows mixed system architectures to be considered during migration periods, although each individual link remains constrained by its slowest participating device. Table routing and the SSP engine support managed discovery across the fabric. Redundant designs must add explicit failover, power, and path-monitoring requirements rather than assuming that a single expander automatically provides high availability.
Embedded Storage Controller
The VSC7153SS-02 is applicable when an embedded controller needs to fan out a SAS connection to multiple targets while maintaining a manageable device topology. Twenty-four PHYs provide substantial endpoint density without requiring an equivalent number of separate interface devices. This can simplify board partitioning and topology management in industrial servers, test systems, and specialized processing platforms. The implementation must be checked against the controller's SAS initiation capabilities, operating-system or storage-stack support, reference-clock architecture, and the exact electrical limits of the selected package.
SAS Edge Expansion in Legacy Systems
The VSC7153SS-02 can bridge a legacy 1.5 Gbps SAS environment into a fabric that also contains 3.0 Gbps paths, subject to link negotiation and end-device support. This makes it relevant to storage upgrades where controllers and disks operate at different generations but still share compatible SAS infrastructure. The expander must be configured and validated with the complete initiator, target, and management stack. Engineers should confirm per-link fallback behavior, discovery through the SSP engine, and whether the enclosure's connectors and cables preserve adequate signal margin at the intended distance.
SAS Management and Discovery Fabric
The table-routing and SSP-engine functions make the VSC7153SS-02 relevant to managed SAS fabrics in which controllers must discover target devices and maintain topology information. The 24-PHY count allows numerous links to participate in one managed fabric while reducing separate switching complexity. For appliance designs, verify the management transport, configuration persistence behavior, firmware compatibility, and supported operating systems. A laboratory validation should exercise discovery after cold start, controller reset, expander reset, target replacement, and link-speed transitions before the design is released to storage enclosures.
엔지니어링 참조 데이터: VSC7153SS-02 — 비교, 설계 지침 및 규정 준수 정보.
선택 가이드
대체품과의 비교
| 파라미터 | 이 제품 |
|---|---|
| Manufacturer | Analog Devices / Maxim Integrated |
| Device Type | SAS edge/fanout expander |
| Number of PHYs | 24 PHYs |
| Supported SAS Link Rates | 1.5 Gbps and 3.0 Gbps |
| Routing Architecture | Table routing |
| Protocol Engine | SSP engine |
설계 노트
Assign the VSC7153SS-02 SAS pins strictly from the pin-description table for the exact SS orderable suffix. Keep each differential SAS pair routed with continuous reference-plane support, matched impedance, and minimized stubs. Avoid placing incompatible circuitry between the expander and backplane connectors, and use the manufacturer's recommended layer stack and via geometry so that 3.0 Gbps operation is not limited by avoidable discontinuities.
Confirm the supply voltage, supply-current limits, sequencing, and decoupling recommendations in the VSC7153-02 electrical-characteristics table before power-distribution design. Place required bulk and high-frequency bypass capacitance close to the device's power and ground pins, preserve a low-impedance return path, and account for transients generated during SAS link training. Do not infer an exposed-pad connection or supply arrangement from the MPN suffix.
Validate the complete path from the expander through connectors and cables to the attached SAS device, rather than testing only the IC pins. Use the manufacturer's reference clock, termination, and topology guidance where specified, and check receiver and transmitter margins with representative 1.5 Gbps and 3.0 Gbps traffic. Include worst-case cable length, connector loss, adjacent-port coupling, and transition effects in simulation and system measurements.
Do not treat a family-related MPN as a drop-in substitute without checking package drawings, pin names, clock requirements, management interfaces, firmware dependencies, and absolute maximum ratings. Likewise, do not infer a 24-bay deployment solely from the 24-PHY count: initiator links, redundancy, path topology, power-loss behavior, and supported discovery methods can reduce the usable disk count. Confirm these constraints in the family documentation.
규정 준수 정보
Compliance status is not stated for this orderable MPN. Check the manufacturer product page, current datasheet, and declaration documents for the exact package and ordering option.