Analog Devices

VSC7154XYS/C - 36-PHY SAS Expander | Analog Devices

MPN: VSC7154XYS/C ✓ فعال
MOQ: 1 |

VSC7154XYS/C جائزہ

Analog Devices VSC7154XYS/C is a multimode, user-configurable 36-PHY Serial Attached SCSI expander supporting 1.5 Gbps and 3.0 Gbps SAS operation. Designed for edge and fanout configurations, the device expands the number of physical storage links available to an embedded storage controller. Its SAS functionality follows the ANSI T10 Serial Attached SCSI 1.0 and 1.1 specifications for port expansion.

A SAS expander is an interface-controller semiconductor that sits between storage initiator logic and SAS target devices. It divides one logical storage connection into multiple physical links and can operate as an edge expander or a fanout expander. The VSC7154XYS/C therefore belongs to the hierarchy of SAS interface controller, I/O expander, interface IC, and semiconductor. In an edge configuration, it adds drive connectivity without requiring additional host-bus adapters; in a fanout configuration, it consolidates multiple expander paths.

The principal feature is its 36 physical-layer channels, combined with support for both 1.5 Gbps and 3.0 Gbps data rates. Thirty-six PHYs provide the physical connectivity required by midrange and enterprise storage systems, including blade servers, JBOD configurations, and RAID systems. One verified distributor listing reports a low power consumption of 500 mW, although system-level power requirements should be evaluated from the complete manufacturer datasheet and the intended board configuration.

The edge-versus-fanout operating mode is user-configurable, allowing one expander design to support different storage topologies. This flexibility is useful when a system must connect multiple disks or enclosure backplanes while retaining high serial-link throughput. Before placing the device in a new design, confirm the supported SAS topology, firmware behavior, clocking requirements, reference design, and power-supply sequencing against the manufacturer documentation.

Signal-integrity management is a central implementation concern because the expander must preserve communication across numerous simultaneous SAS links. PCB routing should use controlled-impedance transmission paths, minimize stub lengths, provide appropriate connector and termination practices, and maintain suitable separation between adjacent high-speed nets. The expander also requires stable supply rails and careful thermal planning when all 36 PHYs are active.

This page consolidates the verified product identity, SAS capabilities, sourcing information, application context, and practical design considerations into one engineering-oriented reference. It also distinguishes documented functions from parameters that require confirmation in the manufacturer datasheet, helping designers avoid unsupported assumptions before schematic capture, firmware integration, and production qualification.

کے لیے ڈراپ اِن متبادل VSC7154XYS/C — یکساں پیکیج، پن سے پن مطابقت پذیر۔ مختلف پیکیج والے پرزے جن کے لیے PCB دوبارہ کام درکار ہو، شامل نہیں ہیں۔

اس پروڈکٹ کے لیے کوئی ڈراپ اِن متبادل دستیاب نہیں۔

متبادل کی درخواست کریں

VSC7154XYS/C تفصیلات

Product Type 36-PHY multimode SAS expander
Number of PHYs 36 PHYs
Supported SAS Data Rates 1.5 Gbps and 3.0 Gbps
Supported Expander Modes Edge and fanout modes
Device Category I/O expander
Protocol Serial Attached SCSI (SAS)
ANSI T10 SAS Version 1.0 Support Supported
ANSI T10 SAS Version 1.1 Support Supported
Target Application Embedded midrange and enterprise storage
Storage System 1 Blade servers
Storage System 2 JBOD configurations
Storage System 3 RAID systems
Reported Power Consumption 500 mW
Manufacturer Analog Devices / Maxim Integrated

VSC7154XYS/C standard پن کنفیگریشن گائیڈ

VSC7154XYS/C (standard پیکیج) کے لیے پن کنفیگریشن۔ پن نمبرنگ، فنکشنز اور کنکشن ڈایاگرامز مینوفیکچرر کے ڈیٹا شیٹ میں بیان کیے گئے ہیں۔ درست فٹ پرنٹ اور سولڈرنگ رہنما ہدایات کے لیے اسی سے رجوع کریں۔

VSC7154XYS/C کے لیے standard پیکیج پن آؤٹ ڈایاگرام

کے لیے تفصیلی پن آؤٹ ڈیٹا دستیاب نہیں VSC7154XYS/C.

رجوع کریں ڈیٹا شیٹ مکمل پن کنفیگریشن کے لیے۔

عام استعمالات

VSC7154XYS/C کے لیے موزوں ہے 6 ایپلیکیشنs: Blade Server Storage Expansion, JBOD Enclosure Backplane, Enterprise RAID Array, Embedded Storage Chassis, Direct-Attach Storage Consolidation, High-Density Storage Enclosure.

🖥️

Blade Server Storage Expansion

The VSC7154XYS/C fits blade-server designs that need more SAS drive connections than a host-facing controller can provide directly. Its 36 PHYs create a broad physical-link fabric, while support for both 1.5 Gbps and 3.0 Gbps SAS rates accommodates different generation storage targets. Edge operation can add enclosure links near the drives, and fanout operation can consolidate multiple expander paths. The implementation should be validated for connector reach, power sequencing, thermal loading, and firmware behavior in the complete server configuration.

🏭

JBOD Enclosure Backplane

The VSC7154XYS/C is well suited to a JBOD backplane where one SAS domain must reach numerous disks. Thirty-six PHYs provide the physical connectivity needed for multi-drive enclosure designs, and edge mode provides a practical way to extend the host-facing storage path toward the drive backplane. For a production design, preserve controlled-impedance routing, minimize connector and cable transitions, verify the supported SAS link rate at each physical connection, and test power-up sequencing across the expander and attached storage devices.

🖥️

Enterprise RAID Array

The VSC7154XYS/C supports enterprise RAID architectures that connect multiple disks, enclosure services, and expansion paths through a SAS fabric. The configurable edge and fanout modes allow system architects to align the expander topology with the controller and enclosure layout, while the 36-PHY count reduces the need for multiple physical-layer blocks. Qualification should cover active-link power, connector reliability, firmware fault handling, and full-array operation with the intended disk population rather than a reduced test configuration.

🔧

Embedded Storage Chassis

Embedded storage chassis can use the VSC7154XYS/C as a central SAS connectivity device when the product must support several external disks, redundant storage paths, or multiple internal enclosures. Its 36-PHY capacity and support for edge and fanout topologies provide flexibility in routing storage traffic behind a common expansion point. Designers should account for ground-plane continuity, return paths, connector launch geometry, and power-supply headroom. The final configuration must also be checked against the manufacturer's supported topology and reference circuitry.

🌐

Direct-Attach Storage Consolidation

The VSC7154XYS/C can consolidate direct-attach storage links into a SAS expansion fabric where a system requires more endpoints than its initiator-facing interface supports. Both 1.5 Gbps and 3.0 Gbps rates provide compatibility options for installed SAS generations, and the user-configurable operating mode supports different enclosure arrangements. This role does not replace a host SAS initiator; the expander remains a bridge between storage endpoints and broader fabric infrastructure. Link training, discovery, failover, and management behavior must therefore be verified with the complete controller set.

💡

High-Density Storage Enclosure

The 36-PHY count makes the VSC7154XYS/C relevant to high-density storage enclosures where drive connections must be distributed efficiently across internal backplanes. Edge mode can provide local port expansion, while fanout mode can support a hierarchy of enclosure connections. Practical implementation requires careful attention to power delivery because simultaneous SAS activity can increase board-level thermal load. Keep high-speed traces short where possible, provide solid reference planes, observe connector and package layout guidance, and verify enclosure hot-swap or power-cycling behavior in system tests.

What is the VSC7154XYS/C?
The VSC7154XYS/C is a 36-PHY, multimode Serial Attached SCSI expander from Analog Devices / Maxim Integrated. It supports 1.5 Gbps and 3.0 Gbps SAS links and can be configured for edge or fanout expansion. According to the manufacturer documentation, the device implements SAS port expansion defined by ANSI T10 SAS 1.0 and 1.1, making it suitable for embedded blade-server, JBOD, and RAID storage systems.
How many SAS PHYs does VSC7154XYS/C have?
The VSC7154XYS/C provides 36 physical-layer channels for SAS connectivity. The 36-PHY count allows the expander to fan storage traffic across numerous physical links in edge and fanout arrangements. Manufacturer documentation identifies the part as a multimode, user-configurable SAS expander intended for midrange and enterprise storage applications, including blade servers, JBODs, and RAID systems.
Which SAS data rates does VSC7154XYS/C support?
The VSC7154XYS/C supports SAS signaling at 1.5 Gbps and 3.0 Gbps. These rates correspond to the serial-data capabilities identified for the device and support both legacy and faster SAS link operation within the ANSI T10 SAS 1.0 and 1.1 framework. Confirm the negotiated link rate and corresponding electrical requirements in the complete manufacturer datasheet for the intended system design.
What is the difference between edge and fanout SAS expander modes?
An edge SAS expander adds physical drive links to an existing host-facing storage connection, while a fanout expander consolidates multiple expander paths behind a common interface. The VSC7154XYS/C is user-configurable for both edge and fanout applications. Its mode selection and associated firmware behavior should be validated against the manufacturer reference design before the device is used in production storage equipment.
Where can I download the VSC7154XYS/C datasheet?
The VSC7154XYS/C datasheet can be accessed through the official PDF link listed on this page or through the manufacturer product documentation. Use the pin-description table, electrical characteristics, and SAS interface sections when assigning pins, selecting regulators, and designing the board. The document linked here identifies the device as a 36-PHY multimode SAS edge and fanout expander.
Where can I find the VSC7154XYS/C pinout?
The VSC7154XYS/C pin assignments are defined in the pin-description table of the manufacturer datasheet. Use that table to verify supply pins, ground connections, reference clocks, serial connections, management signals, and configuration pins on the exact VSC7154XYS/C package. Package dimensions and the complete pin map must be checked before schematic capture or PCB layout begins.
Is VSC7154XYS/C suitable for JBOD and RAID systems?
Yes, the VSC7154XYS/C is specifically targeted at embedded midrange and enterprise storage environments that include blade servers, JBODs, and RAID systems. Its 36-PHY configuration and support for edge or fanout operation make it applicable where a storage controller must reach multiple drives or enclosure backplanes. Final qualification should include thermal, firmware, connector, and signal-integrity testing in the complete system.
What is the best drop-in replacement for VSC7154XYS/C?
No verified pin-to-pin drop-in replacement for VSC7154XYS/C was identified. A valid replacement must preserve the 36-PHY footprint, SAS edge and fanout functionality, 1.5 Gbps and 3.0 Gbps operation, power architecture, firmware requirements, and connector routing. Use the Request a Quote form on this page to discuss sourcing support, and require manufacturer or authorized-channel confirmation before treating any substitute as interchangeable.
Can VSC7154XYS/C be replaced by another 36-PHY SAS expander?
A different 36-PHY SAS expander is not automatically a direct replacement for the VSC7154XYS/C. Drop-in suitability requires more than an equal PHY count: the package footprint, pin functions, voltage requirements, clocking, reset behavior, SAS operating modes, firmware, and host-facing interface must align. No candidate meeting those criteria was verified, so PCB substitution should not proceed without a formal engineering review.
When should I choose the VSC7154XYS/C instead of a SAS controller?
Choose the VSC7154XYS/C when the design needs physical SAS port expansion rather than direct initiation or direct attachment of storage devices. It is appropriate for systems that need numerous drive links distributed through edge or fanout topology, including JBOD and RAID architectures. If the design instead requires a host SAS controller, initiator interface, or direct disk attachment, choose that controller function rather than using an expander.
Is VSC7154XYS/C suitable for enterprise storage applications?
The VSC7154XYS/C is suitable for embedded midrange and enterprise storage applications, including blade servers, JBODs, and RAID systems. Its 36 PHYs and user-configurable edge or fanout operation support high-port-count storage interconnect designs. Production use still requires validation of thermal conditions, power sequencing, firmware behavior, connector compatibility, and the complete link-training process.
What are the key specifications of VSC7154XYS/C that engineers should know?
The key documented specifications are 36 PHYs, 1.5 Gbps and 3.0 Gbps SAS operation, multimode edge and fanout expansion, and conformity with ANSI T10 SAS 1.0 and 1.1 port-expansion requirements. The device is classified as an I/O expander from Analog Devices / Maxim Integrated and targets embedded blade-server, JBOD, and RAID storage systems.
What can replace the VSC7154XYS/C?
The VSC7154XYS/C can be replaced only by a part verified to match its package, 36-PHY arrangement, SAS edge and fanout modes, 1.5 Gbps and 3.0 Gbps rates, electrical requirements, and firmware expectations. No drop-in alternative was confirmed by the available cross-reference research. Request current sourcing assistance through the Request a Quote form on this page rather than relying on an unverified functional substitute.
Where to buy VSC7154XYS/C online?
The VSC7154XYS/C can be requested through the Request a Quote form on this page, where current availability, lot condition, and shipment details should be confirmed before ordering. The verified product listings identify the manufacturer as Analog Devices / Maxim Integrated and classify the part as a 36-PHY SAS expander. Share the required quantity, date code, target package, and shipment destination with the quote team.
What is the price of VSC7154XYS/C?
Current commercial terms for the VSC7154XYS/C are handled through the Request a Quote form on this page. The form should capture quantity, acceptable date code, target package, delivery location, and shipment method so the quote can reflect the exact VSC7154XYS/C order configuration. No static price figure should be used for budgeting because commercial terms may vary with quantity and supply status.
What is the lead time for VSC7154XYS/C?
The current lead time and available quantity for VSC7154XYS/C should be confirmed through the Request a Quote form on this page. Include your required quantity, approved date code, destination, and target delivery date. The device is listed as an Analog Devices / Maxim Integrated 36-PHY SAS expander, but no manufacturing schedule is stated, so the form is the appropriate channel for a current commitment.

کے لیے انجینئرنگ ریفرنس ڈیٹا VSC7154XYS/C — موازنہ، ڈیزائن رہنمائی، اور تعمیل کی معلومات۔

انتخاب کی گائیڈ

Choose the VSC7154XYS/C for an embedded storage system that requires a high count of SAS physical links and can use an edge or fanout expander topology. It is particularly relevant to blade servers, JBODs, and RAID systems requiring compatibility with 1.5 Gbps and 3.0 Gbps SAS links. The device is an expander rather than a host initiator, so the architecture must also include the appropriate SAS controller or target connectivity. Do not substitute another expander based only on PHY count. A valid replacement must match the exact package footprint, pin functions, electrical requirements, firmware, management behavior, and operating modes. If those requirements cannot be confirmed for another part, retain the VSC7154XYS/C and focus engineering effort on signal integrity, power sequencing, thermal qualification, and complete-system link training.

متبادلات کے ساتھ موازنہ

پیرامیٹر یہ پروڈکٹ
Brand Analog Devices
Number of PHYs 36 PHYs
SAS Data Rate 1.5 Gbps and 3.0 Gbps
Expander Modes Edge and fanout
Device Category SAS I/O expander
Protocol Support ANSI T10 SAS 1.0 and 1.1
Primary Applications Blade servers, JBODs, and RAID systems
Reported Power Consumption 500 mW

اہم امتیازی خصوصیات

  • Broad physical-layer connectivity (بمقابلہNo verified drop-in alternative)
  • Support for two SAS link rates (بمقابلہNo verified drop-in alternative)
  • Flexible storage topology (بمقابلہNo verified drop-in alternative)

ڈیزائن نوٹس

Route every SAS connection as a controlled-impedance differential pair with a continuous reference plane and minimized discontinuities. Keep connector launches and package escapes consistent, avoid unnecessary stubs and test pads, and maintain suitable spacing from unrelated high-speed signals. Validate the final topology with the manufacturer reference layout and perform eye-diagram, jitter, and link-training tests on the assembled board.

Budget supply current for the configured number of active PHYs rather than relying only on a nominal operating-power value. Provide local high-frequency decoupling at the supply pins, confirm sequencing requirements in the manufacturer datasheet, and verify that the regulator can support expected link activity without excessive ripple. Measure startup and shutdown behavior in the complete storage system because controller, expander, and disk power states may not change simultaneously.

A storage system may keep many SAS links active concurrently, making board-level thermal performance more important than the reported device power alone. Use the package thermal information and application reference design to select copper area, airflow, and heat-sinking strategies. Test the populated JBOD or RAID chassis at its maximum supported disk count and ambient temperature, including sustained sequential traffic rather than only idle operating conditions.

Follow the manufacturer layer stack, fanout, via, and decoupling guidance when constructing the PCB. Preserve symmetry between each differential pair, avoid placing vias in the high-speed path when practical, and separate clocks, serial links, and sensitive management signals where the reference design recommends it. Confirm the exact package land pattern and pin map before releasing the fabrication files because the package description is not included in the available product listings.

Do not treat an equal PHY count as proof that another SAS expander is interchangeable. Verify the package footprint, pin functions, supply voltages, reference-clock requirements, management interface, firmware, edge and fanout behavior, and supported link rates. Also avoid designing around unverified package, temperature, or electrical values; obtain the complete manufacturer datasheet before schematic release and use its tables as the controlling references.

تعمیل کی معلومات

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
لیڈ فری
Unknown
ہیلوجن فری
Unknown
کنفلیکٹ منرلز
Unknown

No explicit RoHS, REACH, lead-free, halogen-free, conflict-minerals, or automotive qualification statements were identified for this product.

ڈیٹا کی تصدیق کی تاریخ: 2026-11-11 — ڈیٹا XAIPART کی کمپوننٹ انجینئرنگ ٹیم کے ذریعے تصدیق شدہ اور ترتیب شدہ

متعلقہ تلاشیں

VSC7154XYS/C datasheet VSC7154XYS/C datasheet pdf VSC7154XYS/C pinout VSC7154XYS/C package VSC7154XYS/C equivalent VSC7154XYS/C replacement VSC7154XYS/C cross reference VSC7154XYS/C 36 PHY VSC7154XYS/C SAS expander Analog Devices VSC7154XYS/C VSC7154XYS/C edge fanout VSC7154XYS/C price VSC7154XYS/C stock VSC7154XYS/C JBOD application

متعلقہ اجزاء اور اصطلاحات

Analog Devices Maxim Integrated VSC7154XYS/C VSC7154 36-PHY SAS expander Serial Attached SCSI SAS edge expander SAS fanout expander I/O expander interface controller interface IC semiconductor 1.5 Gbps SAS 3.0 Gbps SAS ANSI T10 SAS 1.0 SAS 1.1 blade server JBOD RAID system physical-layer channel differential pair controlled impedance link training edge and fanout topology
فوری کوٹ RFQ
مکمل تفصیلات بھریں — ہماری سیلز ٹیم 24 گھنٹوں میں جواب دے گی
پارٹ نمبر مینوفیکچرر پیکج QTY ہدف قیمت کل رقم
✓
کوٹ جمع ہو گیا!

ہم 24 گھنٹوں کے اندر آپ کے ای میل کا جواب دیں گے

1
RFQ جمع ہو گیا
2
کوٹ موصول ہو گیا
3
آرڈر دے دیا گیا
4
ادائیگی
5
بھیج دیا گیا
6
ڈیلیور شدہ
RFQ تفصیلات دیکھیں