AD629ANZ - ±270V Difference Amplifier | Analog Devices
MPN: AD629ANZ ✓ Hoạt độngAD629ANZ Tóm tắt
A difference amplifier is a specialized amplifier category that rejects voltage common to both inputs while amplifying the voltage difference between them. In the signal-chain hierarchy, the AD629 belongs to differential amplifiers, instrumentation and buffer amplifiers, and ultimately the broader integrated-circuit amplifier family. This makes it useful where a low-level shunt measurement shares a high-voltage bus with the measurement circuitry.
The AD629ANZ provides a 200 µV input offset voltage and approximately 900 µA operating supply current. Its listed CMRR is 77 dB, while its 500 kHz gain-bandwidth product supports dynamic signal measurement. The high common-mode range permits sensing small voltage drops across current-shunt resistors without separating the measurement ground from the high-voltage power system. The device operates from single or dual supplies and is identified by DigiKey as a current-sense amplifier with one amplifier circuit.
Its internal implementation attenuates one input path with a resistor divider and restores the required differential gain with additional internal resistors and feedback. This architecture enables unity differential gain while maintaining compatibility with high common-mode voltages. The manufacturer datasheet also discusses ways to optimize difference-amplifier performance, including resistor matching, input bias-current compensation, and careful reference-node design.
Typical uses include high-side current measurement in power supplies, motor-control systems, industrial process monitoring, battery-management equipment, and protection circuits. The AD629 can also replace an isolation amplifier in non-isolated measurement systems where galvanic isolation is not required. Its ±270 V common-mode capability is particularly useful when the shunt is positioned near a high-voltage rail.
Designers should minimize differences between the two input networks, provide suitable bypass capacitors, keep sensitive input traces short, and verify common-mode and output-voltage limits across the complete operating range. Input protection, resistor power ratings, and thermal dissipation also require attention when the measured bus approaches the maximum common-mode voltage.
This product summary combines the manufacturer specifications with package, application, and replacement guidance for engineers evaluating the AD629ANZ. It also distinguishes true package-compatible options from nearby amplifiers that require different packages or provide different gains, helping shorten component-selection and PCB-reuse work.
Bộ thay thế dễ dàng lắp đặt cho AD629ANZ — cùng gói, chân-to-chân tương thích. Các bộ phận yêu cầu hàn PCB bị loại trừ.
Các biến thể trong loạt này
Các mẫu cùng loạt có thể lắp đặt dễ dàng tương thích với AD629ANZ (cùng hình factor và footprint) — khác nhau ở Package, Common-Mode Input Voltage Range, Product Type, Mounting Type, Operating Temperature Range.
AD629BNZ
✅ Drop-InLiên hệ để biết giá
Xem tài liệu →INA117P
✅ Drop-InLiên hệ để biết giá
Xem tài liệu →INA149P
✅ Drop-In📋 Tham chiếu thay thế (không có trong danh mục)
AD629ANZ Tỷ lệ tối đa & tính chất điện
| Product Type | High common-mode voltage difference amplifier |
| Number of Circuits | 1 circuit |
| Differential Gain | 1 unity gain |
| Common-Mode Voltage Range | Up to ±270 V |
| Gain-Bandwidth Product | 500 kHz |
| Slew Rate | 2.1 V/µs |
| Input Offset Voltage | 200 µV |
| Common-Mode Rejection Ratio | 77 dB |
| Điện áp cung cấp | 900 µA |
| Điện áp cung cấp | Single or dual ±18 V |
| Khoảng nhiệt độ hoạt động | -40 °C to +85 °C |
| Hộp | 8-pin PDIP |
| Số lượng chân | 8 pins |
| Kiểu lắp đặt | Through-hole |
Hướng dẫn cấu hình chân AD629ANZ 8-pin pdip
Cấu hình chân cho AD629ANZ (8-pin pdip gói). Thành phần số hiệu này có chân đầu vào, đầu ra và nguồn cung cấp. Tham khảo tài liệu thông số kỹ thuật của nhà sản xuất để biết cấu hình chân bù, bù trừ và chân kích hoạt. Hoàn hảo cho điều kiện tín hiệu và mạch khuếch đại.
Không có dữ liệu chân cụ thể sẵn có cho AD629ANZ.
Tham khảo: tài liệu kỹ thuật cho cấu hình chân đầy đủ.
Ứng dụng tiêu biểu
AD629ANZ phù hợp cho 6 Áp dụngs: High-Voltage Power-Supply Current Sensing, Motor-Drive Shunt Monitoring, Battery-Pack Current Monitoring, Industrial Process-Control Monitoring, Power-Protection and Overcurrent Detection, Diagnostics and Test Equipment.
High-Voltage Power-Supply Current Sensing
The AD629ANZ fits high-side current sensing because its common-mode range reaches ±270 V while its unity differential gain preserves a small shunt voltage as a direct measurement signal. Place it across a shunt in the positive supply rail, with input resistance and protection selected for the actual bus voltage. Its listed 500 kHz bandwidth and 2.1 V/µs slew rate support measurements beyond static DC, although the 200 µV input offset must be included in the accuracy budget. The shunt and protection network determine practical current limits, so neither the amplifier nor its external resistors should be sized without checking transient and fault-current conditions.
Được đề xuất
Motor-Drive Shunt Monitoring
The AD629ANZ is useful for monitoring a motor-control shunt when switching-node excursions exceed the range of ordinary low-voltage instrumentation amplifiers. Its ±270 V common-mode capability allows a small differential drop to be measured in a high-voltage bridge environment, while unity gain keeps the signal path simple. The amplifier's 2.1 V/µs slew rate and 500 kHz bandwidth permit dynamic current observations, but PWM edges require attention to input protection, settling behavior, and parasitic coupling. Place the amplifier close to the shunt, isolate the input traces from switching-node copper, and validate the design across the full PWM duty-cycle and temperature range.
Được đề xuất
Battery-Pack Current Monitoring
The AD629ANZ can monitor a battery-management shunt when the pack voltage lies within its high common-mode capability and the required measurement bandwidth remains below 500 kHz. The unity-gain arrangement avoids the signal attenuation of a fixed high-gain amplifier, making the device appropriate for direct shunt-voltage acquisition. Its 200 µV offset contributes directly to current-measurement uncertainty after division by the shunt resistance, while the 77 dB listed CMRR helps reject battery-rail transients. Designers should still include input clamps, account for the amplifier's supply limits, and confirm that the selected ADC and reference provide resolution for the smallest current of interest.
Được đề xuất
Industrial Process-Control Monitoring
The AD629ANZ supports industrial measurement systems that monitor small differential process signals while the surrounding equipment operates at elevated common-mode voltage. Its ±270 V common-mode range can simplify sensing in systems that would otherwise require isolation, and the single-circuit PDIP-8 package supports straightforward through-hole assembly and prototype rework. For process-control loops, the 500 kHz bandwidth and 2.1 V/µs slew rate are useful, but system latency also depends on the shunt, input network, filter, and ADC. Keep input resistance symmetrical to preserve common-mode rejection and route the measurement ground in accordance with the manufacturer's recommended application circuit.
Được đề xuất
Power-Protection and Overcurrent Detection
The AD629ANZ can form the sensing element of a fast overcurrent detection channel because it separates a small differential overload signal from a high supply voltage. The 2.1 V/µs slew rate supports comparatively fast signal movement, and the 500 kHz bandwidth avoids the behavior of a much slower instrumentation stage. Protection performance still depends on propagation delay through the external comparator, filter, and system logic, as well as the shunt's pulse-energy rating. Use current limiting or clamps to protect the inputs, verify absolute maximum conditions during short circuits, and keep the high-current copper path physically separate from the amplifier's sensitive input routing.
Được đề xuất
Diagnostics and Test Equipment
The AD629ANZ is appropriate for diagnostic instruments that must measure low-level differential voltages superimposed on a high-voltage test rail. Its unity gain preserves the shunt signal without requiring a second scaling stage, and its 500 kHz bandwidth is suitable for many power-system waveform measurements. The 200 µV offset and 77 dB CMRR should be included when establishing uncertainty and common-mode-rejection specifications. Instrument designers also need to account for input bias current, reference-node behavior, supply-noise coupling, and the dynamic range required by the ADC. Guard the input traces, bypass the supply pins locally, and verify performance with the intended common-mode waveform rather than only a low-level laboratory signal.
Được đề xuất
Tóm tắt các sản phẩm được đề xuất
Dữ liệu tham khảo kỹ thuật cho AD629ANZ — so sánh, hướng dẫn thiết kế và thông tin tuân thủ.
Hướng dẫn chọn lựa
So sánh với các sản phẩm thay thế
| Tham số | Sản phẩm này | AD629BNZ | INA117P | INA149P |
|---|---|---|---|---|
| Package | PDIP-8 | PDIP-8 | PDIP-8 | PDIP-8 |
| Brand | Analog Devices | Analog Devices | Texas Instruments | Texas Instruments |
| Mounting Style | Through-hole | Through-hole | Through-hole | Through-hole |
Bảo phân biệt quan trọng
- High common-mode measurement capability (vsINA117P)
- Unity differential gain (vsINA117P)
- Single-function difference-amplifier architecture (vsINA149P)
Ghi chú thiết kế
Route the two difference-amplifier inputs as a closely matched, symmetric pair and keep them away from high-current or switching-node copper. Small resistance and capacitance differences between the input networks can degrade common-mode rejection even when the amplifier itself specifies 77 dB CMRR. Use the manufacturer's recommended resistor values and reference connection, minimize loop area, and provide a solid ground return for the measurement circuit rather than relying on a narrow signal-ground trace.
Do not treat the ±270 V common-mode rating as permission to exceed any absolute maximum input, supply, or output condition. The common-mode input voltage and amplifier supply rails are separate constraints. Use appropriately rated input protection, verify differential and common-mode stress during startup and faults, and calculate the power rating of any series input resistors. When the bus can exceed the rated common-mode range, disconnect or protect the measurement path instead of relying on the amplifier alone.
Bypass the supply pins at the device with the capacitance and ESR requirements specified by Analog Devices, and decouple sensitive analog nodes according to the recommended application circuit. The listed 900 µA supply current excludes dynamic output and external-network loading, so total power depends on supply voltage, output swing, output current, and system transients. Estimate the average and worst-case dissipation at the highest expected temperature, then verify that the PDIP-8 package and surrounding airflow maintain acceptable junction temperature.
Thông tin tuân thủ
The retrieved manufacturer and distributor summaries do not explicitly state the required environmental, material, or automotive compliance classifications. No compliance claim is inferred from the package type or product category.