AT90CAN128-16MJ - 16MHz AVR CAN MCU 128KB | Microchip
MPN: AT90CAN128-16MJ ✗ Cuối đờiAT90CAN128-16MJ Tóm tắt
A microcontroller is a programmable semiconductor that integrates a processor core, memory, and peripheral functions onto one device. The AT90CAN128 belongs to the AVR microcontroller family and combines an embedded control processor with CAN communications, serial interfaces, timers, and GPIO. Its CAN controller supports CAN 2.0A and CAN 2.0B protocols, while its peripheral set allows a single device to manage local control functions and communicate over a robust industrial network.
The AT90CAN128-16MJ provides 128 KB of ISP flash memory for in-system programming, 4 KB of EEPROM for nonvolatile data retention, and 4 KB of SRAM for working memory. Its 53 general-purpose I/O lines support digital inputs and outputs, while four flexible timer/counter blocks provide timing, compare, capture, and PWM functions. Two USARTs, an SPI interface, and a byte-oriented two-wire serial interface expand its connectivity beyond CAN.
The 16 MHz operating frequency gives the AVR core sufficient throughput for protocol handling, control-loop execution, and peripheral management. The -16 speed designation identifies the 16 MHz configuration, while the MJ ordering code identifies the 64-QFN package configuration. Because the device integrates the CAN controller, only an external CAN transceiver is required to connect the MCU logic-level CAN TX and RX signals to a physical bus.
Typical uses include automotive gateway modules, industrial automation controllers, CAN-connected sensors, vehicle diagnostic equipment, building-control nodes, and embedded instrumentation. A compact 9 x 9 mm QFN package supports space-constrained designs, but its fine pitch and exposed pad require careful PCB layout, adequate copper thermal paths, and assembly-process control.
For PCB implementation, use the manufacturer pin-description table to assign every power, ground, programming, clock, communications, and GPIO connection. Place input, output, and decoupling capacitors according to the manufacturer reference design, provide a continuous ground reference beneath the exposed pad, and confirm that the selected transceiver, oscillator, and power architecture meet the system timing and bus requirements.
This page combines the AT90CAN128 family architecture with package-specific guidance, engineering comparisons, sourcing information, and application-oriented design notes. It helps designers evaluate the 16 MHz CAN-capable MCU for embedded industrial, automotive, and control-system designs before completing the board-level schematic and layout review.
Bộ thay thế dễ dàng lắp đặt cho AT90CAN128-16MJ — cùng gói, chân-to-chân tương thích. Các bộ phận yêu cầu hàn PCB bị loại trừ.
Không có bộ thay thế dễ dàng lắp đặt sẵn có cho sản phẩm này.
Yêu cầu các bộ thay thếAT90CAN128-16MJ Tỷ lệ tối đa & tính chất điện
| Microcontroller Family | AVR 90CAN |
| Architecture | 8-bit AVR RISC |
| Tần số xung maksimum | 16 MHz |
| Flash Program Memory | 128 KB |
| EEPROM Memory | 4 KB |
| SRAM | 4 KB |
| General-Purpose I/O Lines | 53 |
| General-Purpose Working Registers | 32 |
| CAN Controller | CAN 2.0A and CAN 2.0B |
| UART Interfaces | 2 |
| Timer/Counter Blocks | 4 |
| Serial Interface | SPI and byte-oriented two-wire serial interface |
| Hộp | 64-QFN, 9 x 9 mm |
| Exposed Pad | Yes |
| Kiểu lắp đặt | Surface mount |
| Program Memory Type | ISP flash |
Hướng dẫn cấu hình chân AT90CAN128-16MJ 64-qfn, 9 x 9 mm
Cấu hình chân cho AT90CAN128-16MJ (64-qfn, 9 x 9 mm gói). IC số này bao gồm chân GPIO, giao diện truyền thông (UART, SPI, I2C) và chân nguồn. Tham khảo tài liệu thông số kỹ thuật của nhà sản xuất để biết các chức năng chân thay thế và tùy chọn cấu hình. Cực kỳ quan trọng cho thiết kế hệ thống tích hợp và lập trình PCB.
Không có dữ liệu chân cụ thể sẵn có cho AT90CAN128-16MJ.
Tham khảo: tài liệu kỹ thuật cho cấu hình chân đầy đủ.
Ứng dụng tiêu biểu
AT90CAN128-16MJ phù hợp cho 6 Áp dụngs: Automotive CAN Gateway, Industrial Automation Node, CAN-Connected Sensor Controller, Vehicle Diagnostic Interface, Building Control Terminal, Embedded Test and Control Module.
Automotive CAN Gateway
The AT90CAN128-16MJ fits an automotive gateway that must exchange diagnostic, body, or sensor data between CAN segments while retaining local control logic. Its hardware CAN controller supports CAN 2.0A and CAN 2.0B, while 128 KB of flash provides room for protocol routing, diagnostics, and application firmware. The 64-QFN package reduces board area, although the exposed pad and fine-pitch routing require careful layout. A suitable CAN transceiver, protection network, reference clock, and automotive-rated power architecture must be evaluated separately for the vehicle environment.
Được đề xuất
Industrial Automation Node
The AT90CAN128-16MJ is appropriate for a distributed industrial controller that monitors inputs and drives outputs while sharing operating data over a CAN bus. Its 53 GPIO lines reduce the need for external digital I/O expansion, and four timer/counter blocks support timing and PWM tasks. The 16 MHz AVR core manages communication and control firmware, while 4 KB of EEPROM preserves configuration values across power cycles. Industrial implementations should add suitable isolation, surge protection, watchdog strategy, and environmental qualification beyond the MCU itself.
Được đề xuất
CAN-Connected Sensor Controller
The AT90CAN128-16MJ can serve as the local controller for a CAN-connected sensor or actuator, combining data acquisition, logic, timers, and network communication in one device. Its 128 KB of ISP flash accommodates drivers, filtering, calibration, and protocol code, while the CAN controller offloads frame handling from the CPU. The 64-QFN footprint is useful in compact instrumentation. Designers must allocate pins for the selected sensors, provide a precision clock as required, and use the manufacturer pin table to avoid conflicts among CAN, serial, timer, and GPIO functions.
Được đề xuất
Vehicle Diagnostic Interface
The AT90CAN128-16MJ fits a diagnostic interface that connects vehicle CAN traffic to a service tool, display, or service computer. The integrated CAN controller supports standard frame handling, while 128 KB of flash provides space for diagnostic identifiers, message filtering, fault logging, and communications software. Its two USARTs and SPI interface can connect to a host and local storage or display. For a production diagnostic product, verify transceiver fault behavior, bus termination, ESD protection, supply transients, and the required automotive temperature and qualification conditions.
Được đề xuất
Building Control Terminal
The AT90CAN128-16MJ can implement a connected building-control terminal for lighting, HVAC, access equipment, or environmental sensors. Its 53 GPIO lines support multiple digital inputs and outputs, while the CAN controller enables distributed communication with floor controllers or building equipment. Two USARTs, SPI, timers, PWM outputs, and 4 KB of EEPROM broaden the terminal capabilities beyond basic bus control. Firmware can implement debounce, actuation limits, fault reporting, and local overrides, while the compact QFN package supports space-constrained control panels.
Được đề xuất
Embedded Test and Control Module
The AT90CAN128-16MJ is suitable for a compact test or control module that combines stimulus sequencing, measurement control, logging, and CAN communication. Four timer/counter blocks support timing and PWM functions, 53 GPIO lines connect to control logic, and 4 KB of SRAM supports working buffers. The 128 KB flash region accommodates firmware images, test sequences, and diagnostic routines. The device should be paired with suitable analog front-end circuitry because the MCU's GPIO and communications peripherals do not replace precision measurement or high-voltage driver stages.
Được đề xuất
Tóm tắt các sản phẩm được đề xuất
Dữ liệu tham khảo kỹ thuật cho AT90CAN128-16MJ — so sánh, hướng dẫn thiết kế và thông tin tuân thủ.
Hướng dẫn chọn lựa
So sánh với các sản phẩm thay thế
| Tham số | Sản phẩm này | AT90CAN128-16AU | AT90CAN128-16MU | AT90CAN128-16MUR |
|---|---|---|---|---|
| Brand | Microchip Technology | Microchip Technology | Microchip Technology | Microchip Technology |
| Package | 64-QFN, 9 x 9 mm | 64-lead TQFP | 64-lead TQFP | 64-lead TQFP |
| Clock Frequency | 16 MHz | 16 MHz | 16 MHz | 16 MHz |
| Flash Memory | 128 KB | 128 KB | 128 KB | 128 KB |
| EEPROM Memory | 4 KB | 4 KB | 4 KB | 4 KB |
| SRAM | 4 KB | 4 KB | 4 KB | 4 KB |
| GPIO Lines | 53 | 53 | 53 | 53 |
| CAN Controller | CAN 2.0A and CAN 2.0B | CAN 2.0A and CAN 2.0B | CAN 2.0A and CAN 2.0B | CAN 2.0A and CAN 2.0B |
Bảo phân biệt quan trọng
- Compact package for CAN-connected embedded controllers (vsAT90CAN128-16MU)
- Same 16 MHz CAN controller architecture in related package options (vsAT90CAN128-16AU)
- Integrated communications and control resources (vsAT90CAN128-16MUR)
Ghi chú thiết kế
Use the manufacturer package drawing and pin-description table to build the 64-QFN land pattern. Assign the exposed pad to the required ground or power-plane connection, provide uninterrupted thermal-via arrays beneath it, and keep high-speed or sensitive nets away from the pad's copper return path. Confirm the selected assembly process supports the package pitch and inspect the pin-1 orientation before releasing artwork.
The MCU requires a local low-impedance supply network because the CAN transceiver, clock circuitry, and connected loads may create fast current transitions. Follow the manufacturer bypass-capacitor recommendations, place the required decoupling capacitance directly at the relevant supply pins, and provide adequate bulk energy close to the device. Confirm startup current, supply tolerance, and clock ramp behavior against the exact -16MJ electrical requirements.
Keep the MCU CAN TX and RX traces short and route them away from clocks, switching nodes, and high-current outputs. The MCU contains the protocol controller but not the physical bus driver, so the external transceiver determines bus-level timing and fault tolerance. Match interfaces, isolate the transceiver if required by the system, apply the designated bus protection network, and verify termination placement at physically correct locations.
Do not substitute the -16AU, -16MU, or -16MUR ordering codes as PCB drop-ins for the -16MJ device; these family members use a different package from the 64-QFN target. Likewise, confirm that a cross-family MCU exposes equivalent clock, programming, reset, interrupt, and CAN resources. For an existing design, verify every net against both package drawings and treat any footprint or pin-function difference as a redesign.
Thông tin tuân thủ
The exact AT90CAN128-16MJ qualification and environmental-compliance declarations must be confirmed from the manufacturer product page and the lot-specific documentation.