DG411FDY+ - Quad Fault-Protected SPST Switch | Analog Devices
MPN: DG411FDY+ ✓ Hoạt độngDG411FDY+ Tóm tắt
An analog switch is a semiconductor device that routes signals between terminals under digital control. The DG411F family belongs to the analog switch and multiplexer hierarchy, where SPST means single-pole, single-throw and 1:1 means the conducting path connects one terminal to one terminal rather than selecting among multiple channels. Fault-protected, rail-to-rail construction is useful when signals may approach the supply rails or exceed the normal operating range during fault conditions.
The DG411FDY+ provides four independently controlled switches in one 16-SOIC package. The distributor listing identifies 220 ns turn-on time, 160 ns turn-off time, and 47 pF input capacitance. Its 35-ohm maximum on-resistance supports low-voltage analog routing, while the four-circuit arrangement reduces component count when several signals must be isolated, sampled, or connected to instrumentation.
The device is specified for positive and negative supply operation from 4.5 V to 20 V and -20 V to -4.5 V, with operation extending to 36 V in one supply arrangement. These rail-to-rail capabilities make the switches suitable for bipolar analog signals and systems whose signal range is close to the available supply voltage. Operating temperature is -40°C to +85°C, allowing use in industrial and extended-temperature equipment.
Typical uses include test and measurement input selection, sensor multiplexing, audio signal routing, data-acquisition systems, and analog isolation networks. The DG411FDY+ is particularly appropriate when four independent signal paths are required and a conventional mechanical relay would be too large, slow, or power-hungry. Its 220 ns turn-on and 160 ns turn-off characteristics also make it more responsive than electromechanical switching at signal frequencies where those transition times matter.
PCB design should preserve the pinout and pin numbering shown in the manufacturer datasheet, provide a continuous ground reference, and route sensitive analog traces away from switching nodes and digital control lines. Check signal amplitude against the negative and positive supply limits, verify the operating voltage before enabling a switch, and account for capacitance when driving long traces or high-impedance sources.
This product page combines the manufacturer device description with practical selection, application, replacement, and PCB guidance. It also distinguishes pin-compatible ordering options from alternatives that use a different package, helping engineers evaluate replacement choices before committing to a board layout.
Bộ thay thế dễ dàng lắp đặt cho DG411FDY+ — cùng gói, chân-to-chân tương thích. Các bộ phận yêu cầu hàn PCB bị loại trừ.
Các biến thể trong loạt này
Các mẫu cùng loạt có thể lắp đặt dễ dàng tương thích với DG411FDY+ (cùng hình factor và footprint) — khác nhau ở Number of Switches, Package, RoHS Status, Switch Configuration.
DG411FDY-T
✅ Drop-In📋 Tham chiếu thay thế (không có trong danh mục)
DG411DY-E3
✅ Drop-InLiên hệ để biết giá
Xem tài liệu →DG411FDY+ Tỷ lệ tối đa & tính chất điện
| Number of Switches | 4 circuits |
| Switch Configuration | 1:1 SPST |
| Maximum On-Resistance | 35 ohm |
| Positive Supply Range | 4.5 V to 20 V |
| Negative Supply Range | -20 V to -4.5 V |
| Maximum Supply Voltage | 36 V |
| Turn-On Time | 220 ns |
| Turn-Off Time | 160 ns |
| Cung cấp电容 | 47 pF |
| Nhiệt độ hoạt động | -40°C to +85°C |
| Hộp | 16-pin SOIC |
| Kiểu lắp đặt | Surface mount |
| Signal Range | Rail-to-rail |
| Fault Protection | Supported |
| Trạng thái RoHS | Compliant |
Hướng dẫn cấu hình chân DG411FDY+ 16-pin soic
Cấu hình chân cho DG411FDY+ (16-pin soic gói). Số thứ tự chân, chức năng và sơ đồ kết nối được xác định trong tài liệu thông số kỹ thuật của nhà sản xuất. Tham khảo nó để biết footprint và hướng dẫn hàn chính xác.
Không có dữ liệu chân cụ thể sẵn có cho DG411FDY+.
Tham khảo: tài liệu kỹ thuật cho cấu hình chân đầy đủ.
Ứng dụng tiêu biểu
DG411FDY+ phù hợp cho 6 Áp dụngs: Test and Measurement Signal Routing, Sensor Signal Multiplexing, Audio Signal Switching, Data Acquisition Front End, Industrial Control Signal Isolation, Automated Test Fixture.
Test and Measurement Signal Routing
The DG411FDY+ fits four-channel routing between a source under test and instrumentation because it combines four independent SPST paths with a listed 35-ohm maximum on-resistance. Its 220 ns turn-on and 160 ns turn-off times allow the switches to change connections quickly compared with electromechanical relays. Place the device close to the protected signal node, maintain a continuous ground plane, and use the pin-description table to assign each switch terminal. Input capacitance is listed at 47 pF, so source impedance and cable capacitance should be included when assessing rise time. This is particularly useful in automated test systems where keeping analog trace lengths short reduces susceptibility to pickup and crosstalk.
Được đề xuất
Sensor Signal Multiplexing
The DG411FDY+ can isolate or connect several sensor lines through its four independent 1:1 SPST switches, avoiding the shared-source behavior of a conventional multiplexer. The 35-ohm maximum on-resistance is appropriate for many low-frequency sensor interfaces, while the 47 pF listed input capacitance matters when driving high-impedance dividers or long shielded leads. Keep sensor returns over a continuous ground plane and place the switch close to the acquisition circuitry to minimize noise pickup. Engineers should verify that each sensor output remains within the -20 V to -4.5 V and 4.5 V to 20 V supply framework and should account for the 220 ns turn-on interval when sequencing measurements.
Được đề xuất
Audio Signal Switching
The DG411FDY+ is suitable for audio path selection in equipment that requires solid-state switching rather than a larger mechanical relay. Four independently controlled SPST circuits can connect microphone, line, or monitoring paths, and the 35-ohm maximum on-resistance introduces a defined series resistance that should be included in gain-loss calculations. The 47 pF input capacitance can influence high-frequency behavior with long PCB traces or cables, so sensitive audio nodes should remain compact. Its 160 ns turn-off and 220 ns turn-on times also support fast source selection. Fault protection improves robustness when an attached signal exceeds the intended operating range, although the datasheet absolute-maximum limits must still be respected.
Được đề xuất
Data Acquisition Front End
The DG411FDY+ supports front-end channel isolation in data-acquisition equipment by placing four independently controlled analog switches between external inputs and measurement circuitry. Its low-voltage 35-ohm maximum on-resistance helps limit signal attenuation, and the short 220 ns turn-on and 160 ns turn-off transitions permit rapid acquisition sequencing. The 47 pF input capacitance should be checked against the selected amplifier’s stability and settling requirements. Use short analog traces, a solid reference plane, and controlled return paths to reduce conversion error. Confirm that each input amplitude remains within the manufacturer’s negative and positive supply specifications before the switch is enabled.
Được đề xuất
Industrial Control Signal Isolation
The DG411FDY+ can route low-voltage control or feedback signals in industrial equipment that requires solid-state isolation between circuit sections. Its four SPST switches, 35-ohm maximum on-resistance, and rail-to-rail signal capability make it appropriate for systems operating from 4.5 V to 20 V positive supplies or corresponding negative supplies. The fault-protected construction adds robustness, although it does not replace a safety-rated isolator when galvanic isolation is mandatory. PCB layout should keep high-energy switching loops away from the analog nodes and preserve uninterrupted ground references beneath the 16-pin SOIC. Review the -40°C to +85°C operating range against the enclosure temperature and thermal conditions.
Được đề xuất
Automated Test Fixture
The DG411FDY+ fits automated fixtures that connect a device under test to several measurement or support paths. Four independently controlled switches eliminate much of the wiring and relay count associated with a conventional fixture, while 220 ns turn-on and 160 ns turn-off times support rapid test sequencing. The 35-ohm maximum on-resistance should be included in impedance-sensitive measurements, and the listed 47 pF input capacitance can affect high-impedance probes and long fixture cables. Keep analog routing close to the connector or test node, provide a stable ground plane, and confirm that fixture transients remain within the absolute-maximum ratings before adding or removing test connections.
Được đề xuất
Tóm tắt các sản phẩm được đề xuất
Dữ liệu tham khảo kỹ thuật cho DG411FDY+ — so sánh, hướng dẫn thiết kế và thông tin tuân thủ.
Hướng dẫn chọn lựa
So sánh với các sản phẩm thay thế
| Tham số | Sản phẩm này | DG411FDY-T | DG411DY |
|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Renesas Electronics |
| Package | 16-SOIC | 16-SOIC | 16-SOIC |
| Number of Switches | 4 circuits | 4 circuits | 4 circuits |
| Switch Configuration | 1:1 SPST | 1:1 SPST | 1:1 SPST |
| Maximum On-Resistance | 35 ohm | 35 ohm | 35 ohm |
Bảo phân biệt quan trọng
- Matches the listed primary electrical configuration of a cross-brand option (vsDG411DY)
- Combines four independently controlled analog paths in one package (vsDG411FDY-T)
- Supports negative and positive signal operation (vsDG411FDY-T)
- Provides fast solid-state transitions (vsDG411DY)
Ghi chú thiết kế
Place the DG411FDY+ close to the source and destination of the routed analog signals to minimize trace pickup and the effect of the listed 47 pF input capacitance. Route each switched signal away from digital control traces and switching-node copper, provide a continuous ground plane beneath the SOIC, and use the manufacturer pin-description table when assigning the four SPST paths. For high-impedance sources, keep the switched node short and avoid sharing a narrow trace between switch and measurement circuitry.
Do not treat the 35-ohm maximum on-resistance as the exact resistance at every signal voltage or temperature; the actual value depends on operating conditions. Likewise, confirm the absolute-maximum ratings for both positive and negative supplies, including transient limits. The listed 220 ns turn-on and 160 ns turn-off times do not guarantee complete settling at a particular frequency because external resistance, capacitance, and source impedance can extend the usable bandwidth.
Evaluate switched-path attenuation and settling with the actual source and load impedances rather than relying only on the maximum on-resistance. The 47 pF input capacitance is especially relevant for high-impedance sensors, long cables, and precision measurement nodes. Keep analog return paths continuous, avoid routing high-current outputs near the switch pins, and use short ground connections to reduce coupling between the four independently controlled circuits.
Design the supply rails for the complete operating environment. The device is listed for 4.5 V to 20 V positive and -20 V to -4.5 V negative supplies, with an extended arrangement reaching 36 V, but the appropriate configuration and exact limits must be checked in the manufacturer datasheet. Confirm that the control-signal levels remain compatible with the selected rail arrangement and that power-supply transients do not exceed the specified absolute maximum values.
Thông tin tuân thủ
RoHS compliance is stated in the JLCPCB component record. No additional REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals status is stated for this ordering code.