ICL7107CPLZ - 3.5-Digit LED ADC | Renesas | 40-PDIP
MPN: ICL7107CPLZ ✓ Hoạt độngICL7107CPLZ Tóm tắt
An analog-to-digital converter, or ADC, converts a continuously varying analog voltage into a numeric representation. The ICL7107 belongs to the special-purpose display-driver ADC category and integrates measurement, conversion, decoding, and display-output functions. Unlike general-purpose ADC packages, it is optimized for instrument-scale seven-segment LED displays, reducing the component count and board area required for standalone panel meters.
The ICL7107CPLZ provides a 3.5-digit measurement format, approximately 3 conversions per second, very high input impedance, and direct LED segment and digit drive. The manufacturer identifies automatic zeroing below 10 uV, zero drift below 1 uV/°C, and input bias current of 10 pA. These characteristics make the converter suitable for voltage measurement in which input loading and temperature-related offset drift could otherwise reduce instrument accuracy.
Internally, the converter integrates seven-segment decoders, display drivers, a reference, and a clock. The ICL7107 version drives a non-multiplexed LED display, while the related ICL7106 is intended for multiplexed LCD operation. Automatic-zeroing circuitry helps reduce input offset errors, and the high-impedance input stage allows the converter to work with relatively high source impedances when the application board is designed appropriately.
Typical uses include digital multimeters, laboratory panel meters, temperature-controller displays, process-monitoring instruments, laboratory power-supply readouts, and portable measurement equipment. The integrated LED drivers make the ICL7107CPLZ especially useful in compact instruments where the display can be wired directly to the converter rather than to an external display controller.
PCB design should preserve the analog signal path from the input pins to the converter and provide the supply and reference bypassing recommended by the manufacturer. A stable input layout, adequate ground-plane continuity, and short display-driver traces help prevent measurement disturbance from LED switching currents. Designers should also account for the converter’s operating temperature and supply requirements before applying it in extended-range or battery-powered products.
This page combines manufacturer-device identification, package and application analysis, verified source links, and engineering-focused design guidance. It also evaluates available same-package alternatives and clarifies where display type, temperature grade, or functional differences require additional qualification before substitution.
Bộ thay thế dễ dàng lắp đặt cho ICL7107CPLZ — cùng gói, chân-to-chân tương thích. Các bộ phận yêu cầu hàn PCB bị loại trừ.
Các biến thể trong loạt này
Các mẫu cùng loạt có thể lắp đặt dễ dàng tương thích với ICL7107CPLZ (cùng hình factor và footprint) — khác nhau ở Mounting Type, Display Output, Package, Resolution, Input Type.
ICL7107CPL+
✅ Drop-InLiên hệ để biết giá
Xem tài liệu →ICL7107CJL
✅ Drop-In📋 Tham chiếu thay thế (không có trong danh mục)
ICL7107CPL+
✅ Drop-InLiên hệ để biết giá
Xem tài liệu →ICL7109CPL
✅ Drop-InLiên hệ để biết giá
Xem tài liệu →ICL7129ACPL+
✅ Drop-InLiên hệ để biết giá
Xem tài liệu →ICL7107CPLZ Tỷ lệ tối đa & tính chất điện
| Converter Type | 3.5-digit analog-to-digital converter |
| Conversion Technology | Successive-approximation ADC |
| Display Output | Direct seven-segment LED display drive |
| Integrated Functions | Seven-segment decoders, display drivers, voltage reference, and clock |
| Automatic Zero | Less than 10 uV |
| Zero Drift | Less than 1 uV/°C |
| Input Bias Current | 10 pA |
| Conversion Rate | Approximately 3 samples per second |
| Nominal Resolution | 12-bit conversion system with 3.5-digit display |
| Analog Input Voltage | -3 V to +2 V |
| Input Type | Differential input |
| Hộp | 40-pin PDIP |
| Số chân | 40 pins |
| Kiểu lắp đặt | Through-hole |
| Moisture Sensitivity Level | MSL 1 |
Hướng dẫn cấu hình chân ICL7107CPLZ 40-pin pdip
Cấu hình chân cho ICL7107CPLZ (40-pin pdip gói). Thành phần số hiệu này có chân đầu vào, đầu ra và nguồn cung cấp. Tham khảo tài liệu thông số kỹ thuật của nhà sản xuất để biết cấu hình chân bù, bù trừ và chân kích hoạt. Hoàn hảo cho điều kiện tín hiệu và mạch khuếch đại.
Không có dữ liệu chân cụ thể sẵn có cho ICL7107CPLZ.
Tham khảo: tài liệu kỹ thuật cho cấu hình chân đầy đủ.
Ứng dụng tiêu biểu
ICL7107CPLZ phù hợp cho 6 Áp dụngs: Digital Multimeter Display, Laboratory Panel Meter, Temperature Instrument Readout, Power Supply Readout, Process Monitoring Instrument, Portable Measurement Meter.
Digital Multimeter Display
The ICL7107CPLZ is suitable for a digital multimeter because its integrated seven-segment decoder and LED drivers eliminate the need for separate display-driver circuitry. The approximately 3 conversions per second rate provides continuously readable voltage, current, or resistance readings without overwhelming the operator. Automatic zeroing below 10 uV and zero drift below 1 uV/°C help preserve measurement stability. A typical instrument routes the selected measurement through analog conditioning, then connects the converter’s differential input and reference network. LED segment currents and return-current paths should be planned carefully so display switching does not disturb the analog input.
Được đề xuất
Laboratory Panel Meter
The ICL7107CPLZ provides a compact solution for laboratory panel meters that require a three-and-a-half-digit numerical readout. Its approximately 3 samples per second conversion rate is sufficient for slowly changing voltage measurements, while the 10 pA input bias current minimizes loading of high-impedance dividers and sensors. The integrated reference, clock, decoders, and LED drivers simplify the display subsystem. For reliable laboratory performance, use a low-noise reference network and a quiet ground return, and place the display-current return path away from the analog input reference point.
Được đề xuất
Temperature Instrument Readout
The ICL7107CPLZ can present temperature measurements from an RTD, thermocouple conditioning circuit, or resistive sensor in a dedicated display module. Its high input impedance and low 10 pA bias current reduce errors when the sensor has appreciable source impedance, while the 3.5-digit format is appropriate for many panel instruments. The converter should operate on a conditioned and referenced sensor signal rather than directly on every raw sensor type. Supply bypassing and input guarding become important when long sensor wiring or wide temperature changes increase leakage and drift risk.
Được đề xuất
Power Supply Readout
The ICL7107CPLZ is useful in laboratory and bench power supplies that need to show output voltage on an integrated LED display. Direct LED drive, internal clocking, and an integrated reference reduce the number of dedicated support components around the measurement path. The approximately 3 conversions per second update rate provides a stable numerical indication under changing load conditions. Analog front-end attenuation must be scaled safely for the converter’s input range, and the display-return current should not share a high-impedance divider node to avoid measurement disturbance.
Được đề xuất
Process Monitoring Instrument
The ICL7107CPLZ can form the readout section of an industrial process-monitoring instrument that displays a slowly varying process voltage. The 3.5-digit output format, direct LED drive, and low input bias current allow the converter to interface with relatively high-impedance transducers while minimizing board complexity. Because industrial environments can introduce electrical noise and ground-potential differences, the input should use shielded or guarded routing where necessary. Confirm the operating temperature, supply limits, and isolation strategy for the final instrument before deployment.
Được đề xuất
Portable Measurement Meter
The ICL7107CPLZ supports portable digital meters because its LED-display functions are integrated into the converter and its low-power architecture suits instruments built around a controlled supply. The approximately 3 conversions per second rate is adequate for handheld readings, and the 10 pA input bias current reduces loading from compact sensor arrangements. Designers should calculate battery and regulator requirements for the converter and LEDs, use a stable reference arrangement, and ensure that the enclosure and PCB do not introduce leakage into the high-impedance input stage.
Được đề xuất
Tóm tắt các sản phẩm được đề xuất
Dữ liệu tham khảo kỹ thuật cho ICL7107CPLZ — so sánh, hướng dẫn thiết kế và thông tin tuân thủ.
Hướng dẫn chọn lựa
So sánh với các sản phẩm thay thế
| Tham số | Sản phẩm này | ICL7107CPL | ICL7107CJL | ICL7107CPL+ | ICL7109CPL | ICL7129ACPL |
|---|---|---|---|---|---|---|
| Package | 40-pin PDIP | 40-pin PDIP | 40-pin PDIP | 40-pin PDIP | 40-pin PDIP | 40-pin PDIP |
| Brand | Renesas Electronics | Renesas Electronics | Renesas Electronics | Renesas Electronics | Renesas Electronics | Renesas Electronics |
| Product Family | ICL7107 | ICL7107 | ICL7107 | ICL7107 | ICL7109 | ICL7129 |
Bảo phân biệt quan trọng
- Direct instrument-style LED display integration (vsICL7129ACPL)
- Lower nominal update rate than ICL7109CPL (vsICL7109CPL)
- Close same-package option for existing ICL7107CPL designs (vsICL7107CPL)
- Low input bias supports high-impedance measurement networks (vsICL7129ACPL)
Ghi chú thiết kế
Separate the analog input and reference network from display-current return paths. LED segment and digit drivers can generate switching transients on supply and ground rails. Connect the converter ground and reference return using a low-impedance path, and place the manufacturer-recommended bypass capacitors directly at the supply pins. This arrangement is especially important when measuring signals close to the converter’s input limits.
Route the sensitive input with short traces, minimize the area surrounded by each signal and its return, and avoid parallel routing with display outputs. Because the ICL7107CPLZ has a 10 pA input bias current, leakage from contaminated boards, flux residue, or long exposed connections can become significant with very high source impedances. Guarding and careful cleaning are useful when the instrument operates in humid or industrial environments.
Do not substitute an LCD-oriented ICL7106 for an existing ICL7107 LED-display board merely because both use 40-pin PDIP packages. The display-driver architecture and display current requirements differ, and the LCD version includes multiplexed backplane drive. Likewise, verify temperature grade, supply range, package construction, and segment mapping for ICL7107CPL, ICL7107CJL, and ICL7107CPL+ before approving a substitution.
Budget the converter’s supply current together with the continuous current demanded by the LED display. The display can dominate the power budget, while its switching pattern can also disturb the reference network. Use separate return paths or local filtering if the selected LED current creates visible measurement ripple. Confirm the converter’s operating and absolute-maximum supply limits against the manufacturer data sheet before increasing LED brightness.
Thông tin tuân thủ
The ICL7107CPLZ is a general-purpose measurement converter rather than an AEC-Q100-qualified automotive device. Specific RoHS, REACH, lead-free, halogen-free, and conflict-minerals status requires confirmation against the current manufacturer product documentation or declaration.