ICL7107CPLZ - 3.5-Digit LED ADC | Renesas | 40-PDIP
MPN: ICL7107CPLZ ✓ 啟用中ICL7107CPLZ 概覽
An analog-to-digital converter, or ADC, converts a continuously varying analog voltage into a numeric representation. The ICL7107 belongs to the special-purpose display-driver ADC category and integrates measurement, conversion, decoding, and display-output functions. Unlike general-purpose ADC packages, it is optimized for instrument-scale seven-segment LED displays, reducing the component count and board area required for standalone panel meters.
The ICL7107CPLZ provides a 3.5-digit measurement format, approximately 3 conversions per second, very high input impedance, and direct LED segment and digit drive. The manufacturer identifies automatic zeroing below 10 uV, zero drift below 1 uV/°C, and input bias current of 10 pA. These characteristics make the converter suitable for voltage measurement in which input loading and temperature-related offset drift could otherwise reduce instrument accuracy.
Internally, the converter integrates seven-segment decoders, display drivers, a reference, and a clock. The ICL7107 version drives a non-multiplexed LED display, while the related ICL7106 is intended for multiplexed LCD operation. Automatic-zeroing circuitry helps reduce input offset errors, and the high-impedance input stage allows the converter to work with relatively high source impedances when the application board is designed appropriately.
Typical uses include digital multimeters, laboratory panel meters, temperature-controller displays, process-monitoring instruments, laboratory power-supply readouts, and portable measurement equipment. The integrated LED drivers make the ICL7107CPLZ especially useful in compact instruments where the display can be wired directly to the converter rather than to an external display controller.
PCB design should preserve the analog signal path from the input pins to the converter and provide the supply and reference bypassing recommended by the manufacturer. A stable input layout, adequate ground-plane continuity, and short display-driver traces help prevent measurement disturbance from LED switching currents. Designers should also account for the converter’s operating temperature and supply requirements before applying it in extended-range or battery-powered products.
This page combines manufacturer-device identification, package and application analysis, verified source links, and engineering-focused design guidance. It also evaluates available same-package alternatives and clarifies where display type, temperature grade, or functional differences require additional qualification before substitution.
直接替換替代品,適用於 ICL7107CPLZ — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: ICL7107CPLZ (相同外形與佔位) — 差異在於 Mounting Type, Display Output, Package, Resolution, Input Type.
ICL7107CPL+
✅ 直接替換聯絡詢價
查看資料表 →ICL7107CJL
✅ 直接替換📋 參考替代品(不在目錄中)
ICL7107CPL+
✅ 直接替換聯絡詢價
查看資料表 →ICL7109CPL
✅ 直接替換聯絡詢價
查看資料表 →ICL7129ACPL+
✅ 直接替換聯絡詢價
查看資料表 →ICL7107CPLZ 最大額定值與電氣特性
| Converter Type | 3.5-digit analog-to-digital converter |
| Conversion Technology | Successive-approximation ADC |
| Display Output | Direct seven-segment LED display drive |
| Integrated Functions | Seven-segment decoders, display drivers, voltage reference, and clock |
| Automatic Zero | Less than 10 uV |
| Zero Drift | Less than 1 uV/°C |
| Input Bias Current | 10 pA |
| Conversion Rate | Approximately 3 samples per second |
| Nominal Resolution | 12-bit conversion system with 3.5-digit display |
| Analog Input Voltage | -3 V to +2 V |
| Input Type | Differential input |
| 封裝 | 40-pin PDIP |
| 腳位數 | 40 pins |
| 安裝類型 | Through-hole |
| Moisture Sensitivity Level | MSL 1 |
ICL7107CPLZ 40-pin pdip 腳位配置指南
ICL7107CPLZ(40-pin pdip 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: ICL7107CPLZ.
請參閱 資料表 以查看完整腳位配置。
典型應用
ICL7107CPLZ 適用於 6 應用s: Digital Multimeter Display, Laboratory Panel Meter, Temperature Instrument Readout, Power Supply Readout, Process Monitoring Instrument, Portable Measurement Meter.
Digital Multimeter Display
The ICL7107CPLZ is suitable for a digital multimeter because its integrated seven-segment decoder and LED drivers eliminate the need for separate display-driver circuitry. The approximately 3 conversions per second rate provides continuously readable voltage, current, or resistance readings without overwhelming the operator. Automatic zeroing below 10 uV and zero drift below 1 uV/°C help preserve measurement stability. A typical instrument routes the selected measurement through analog conditioning, then connects the converter’s differential input and reference network. LED segment currents and return-current paths should be planned carefully so display switching does not disturb the analog input.
推薦
Laboratory Panel Meter
The ICL7107CPLZ provides a compact solution for laboratory panel meters that require a three-and-a-half-digit numerical readout. Its approximately 3 samples per second conversion rate is sufficient for slowly changing voltage measurements, while the 10 pA input bias current minimizes loading of high-impedance dividers and sensors. The integrated reference, clock, decoders, and LED drivers simplify the display subsystem. For reliable laboratory performance, use a low-noise reference network and a quiet ground return, and place the display-current return path away from the analog input reference point.
推薦
Temperature Instrument Readout
The ICL7107CPLZ can present temperature measurements from an RTD, thermocouple conditioning circuit, or resistive sensor in a dedicated display module. Its high input impedance and low 10 pA bias current reduce errors when the sensor has appreciable source impedance, while the 3.5-digit format is appropriate for many panel instruments. The converter should operate on a conditioned and referenced sensor signal rather than directly on every raw sensor type. Supply bypassing and input guarding become important when long sensor wiring or wide temperature changes increase leakage and drift risk.
推薦
Power Supply Readout
The ICL7107CPLZ is useful in laboratory and bench power supplies that need to show output voltage on an integrated LED display. Direct LED drive, internal clocking, and an integrated reference reduce the number of dedicated support components around the measurement path. The approximately 3 conversions per second update rate provides a stable numerical indication under changing load conditions. Analog front-end attenuation must be scaled safely for the converter’s input range, and the display-return current should not share a high-impedance divider node to avoid measurement disturbance.
推薦
Process Monitoring Instrument
The ICL7107CPLZ can form the readout section of an industrial process-monitoring instrument that displays a slowly varying process voltage. The 3.5-digit output format, direct LED drive, and low input bias current allow the converter to interface with relatively high-impedance transducers while minimizing board complexity. Because industrial environments can introduce electrical noise and ground-potential differences, the input should use shielded or guarded routing where necessary. Confirm the operating temperature, supply limits, and isolation strategy for the final instrument before deployment.
推薦
Portable Measurement Meter
The ICL7107CPLZ supports portable digital meters because its LED-display functions are integrated into the converter and its low-power architecture suits instruments built around a controlled supply. The approximately 3 conversions per second rate is adequate for handheld readings, and the 10 pA input bias current reduces loading from compact sensor arrangements. Designers should calculate battery and regulator requirements for the converter and LEDs, use a stable reference arrangement, and ensure that the enclosure and PCB do not introduce leakage into the high-impedance input stage.
推薦
推薦產品摘要
工程參考資料,適用於 ICL7107CPLZ — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | ICL7107CPL | ICL7107CJL | ICL7107CPL+ | ICL7109CPL | ICL7129ACPL |
|---|---|---|---|---|---|---|
| Package | 40-pin PDIP | 40-pin PDIP | 40-pin PDIP | 40-pin PDIP | 40-pin PDIP | 40-pin PDIP |
| Brand | Renesas Electronics | Renesas Electronics | Renesas Electronics | Renesas Electronics | Renesas Electronics | Renesas Electronics |
| Product Family | ICL7107 | ICL7107 | ICL7107 | ICL7107 | ICL7109 | ICL7129 |
主要差異化特點
- Direct instrument-style LED display integration (對比ICL7129ACPL)
- Lower nominal update rate than ICL7109CPL (對比ICL7109CPL)
- Close same-package option for existing ICL7107CPL designs (對比ICL7107CPL)
- Low input bias supports high-impedance measurement networks (對比ICL7129ACPL)
設計說明
Separate the analog input and reference network from display-current return paths. LED segment and digit drivers can generate switching transients on supply and ground rails. Connect the converter ground and reference return using a low-impedance path, and place the manufacturer-recommended bypass capacitors directly at the supply pins. This arrangement is especially important when measuring signals close to the converter’s input limits.
Route the sensitive input with short traces, minimize the area surrounded by each signal and its return, and avoid parallel routing with display outputs. Because the ICL7107CPLZ has a 10 pA input bias current, leakage from contaminated boards, flux residue, or long exposed connections can become significant with very high source impedances. Guarding and careful cleaning are useful when the instrument operates in humid or industrial environments.
Do not substitute an LCD-oriented ICL7106 for an existing ICL7107 LED-display board merely because both use 40-pin PDIP packages. The display-driver architecture and display current requirements differ, and the LCD version includes multiplexed backplane drive. Likewise, verify temperature grade, supply range, package construction, and segment mapping for ICL7107CPL, ICL7107CJL, and ICL7107CPL+ before approving a substitution.
Budget the converter’s supply current together with the continuous current demanded by the LED display. The display can dominate the power budget, while its switching pattern can also disturb the reference network. Use separate return paths or local filtering if the selected LED current creates visible measurement ripple. Confirm the converter’s operating and absolute-maximum supply limits against the manufacturer data sheet before increasing LED brightness.
合規資訊
The ICL7107CPLZ is a general-purpose measurement converter rather than an AEC-Q100-qualified automotive device. Specific RoHS, REACH, lead-free, halogen-free, and conflict-minerals status requires confirmation against the current manufacturer product documentation or declaration.