INA115AU/1K - 1MHz Precision Instrumentation Amplifier | Texas Instruments
MPN: INA115AU/1K ✓ Hoạt độngINA115AU/1K Tóm tắt
An instrumentation amplifier is a specialized amplifier category that combines differential input measurement, high input impedance, accurate gain control, and common-mode rejection. Its place in the signal-chain hierarchy is signal conditioning before an ADC, a sensor interface, or a precision measurement system. The INA115 family extends this hierarchy through switched gain selection, allowing one package to support multiple measurement ranges without changing the external feedback network.
The primary features of INA115AU/1K include a 1 MHz gain-bandwidth product, 50 µV maximum offset voltage, 11 nV/√Hz input-referred noise, and 3 mA typical power consumption. The 1 MHz bandwidth supports faster settling than many precision instrumentation amplifiers, while the low offset and noise are important when extracting small sensor signals from larger common-mode voltages. Switched gain makes the device practical for systems that must change sensitivity between measurement ranges.
The INA115 uses a precision architecture intended to preserve small differential signals in the presence of common-mode voltage and supply variation. Its 16-pin SOIC package provides a conventional surface-mount footprint suitable for industrial and instrumentation equipment. The manufacturer describes the INA115 as a single-channel, switched-gain-enabled precision instrumentation amplifier, with an operating range extending down to ±2.25 V and up to ±18 V according to comparison records for the family.
Typical uses include bridge-sensor signal conditioning, biomedical instrumentation, current-shunt measurement, laboratory test equipment, and precision industrial sensor acquisition. The 1 MHz bandwidth is particularly useful when the measurement must be sampled rapidly, while the 11 nV/√Hz noise specification favors low-amplitude signals such as strain-gauge, thermocouple, and resistive-sensor outputs.
Layout should treat the input stage as a high-impedance precision analog circuit. Keep input and feedback traces short, place gain-control components away from sensitive input nets, provide local supply bypassing, and avoid routing high-current or switching signals beneath the amplifier pins. Confirm gain, supply, output-swing, and settling requirements against the manufacturer's recommended operating conditions before committing the layout.
This product page combines the manufacturer product information, package and ordering data, verified distributor listings, and cross-reference results with application guidance. It also distinguishes true same-package drop-in options from devices that are only functionally similar, helping engineers compare replacement choices without overlooking footprint, gain, noise, or bandwidth constraints.
Bộ thay thế dễ dàng lắp đặt cho INA115AU/1K — cùng gói, chân-to-chân tương thích. Các bộ phận yêu cầu hàn PCB bị loại trừ.
Các biến thể trong loạt này
Các mẫu cùng loạt có thể lắp đặt dễ dàng tương thích với INA115AU/1K (cùng hình factor và footprint).
INA115AUG4
✅ Drop-In📋 Tham chiếu thay thế (không có trong danh mục)
INA115AU
✅ Drop-InLiên hệ để biết giá
Xem tài liệu →INA115AU/1K Tỷ lệ tối đa & tính chất điện
| Product Type | Precision instrumentation amplifier |
| Number of Channels | 1 channel |
| Gain-Bandwidth Product | 1 MHz |
| Maximum Input Offset Voltage | 50 µV |
| Input Noise Density | 11 nV/√Hz |
| Power Consumption | 3 mA |
| Gain Control | Switched gain |
| Supply Voltage Range | ±2.25 V to ±18 V |
| Khoảng nhiệt độ hoạt động | -40 °C to +85 °C |
| Hộp | 16-pin SOIC (DW) |
| Kiểu lắp đặt | Surface mount |
| Slew Rate | 0.06 V/µs |
Hướng dẫn cấu hình chân INA115AU/1K 16-pin soic (dw)
Cấu hình chân cho INA115AU/1K (16-pin soic (dw) gói). Thành phần số hiệu này có chân đầu vào, đầu ra và nguồn cung cấp. Tham khảo tài liệu thông số kỹ thuật của nhà sản xuất để biết cấu hình chân bù, bù trừ và chân kích hoạt. Hoàn hảo cho điều kiện tín hiệu và mạch khuếch đại.
Không có dữ liệu chân cụ thể sẵn có cho INA115AU/1K.
Tham khảo: tài liệu kỹ thuật cho cấu hình chân đầy đủ.
Ứng dụng tiêu biểu
INA115AU/1K phù hợp cho 6 Áp dụngs: Bridge Sensor Signal Conditioning, Medical Instrumentation, Current Shunt Measurement, Laboratory Test Equipment, Precision Industrial Data Acquisition, Portable Sensor Instrument.
Bridge Sensor Signal Conditioning
The INA115AU/1K is well suited to conditioning differential outputs from resistive bridge sensors such as strain gauges and pressure elements. Its 50 µV maximum input offset voltage and 11 nV/√Hz input noise help preserve small millivolt-level changes around a larger common-mode voltage, while the 1 MHz bandwidth supports faster acquisition than a slow precision amplifier. The switched-gain control allows a single analog channel to cover multiple bridge sensitivities. Keep the bridge excitation and analog return paths compact, and use the manufacturer gain configuration when calculating full-scale input range.
Được đề xuất
Medical Instrumentation
The INA115AU/1K can serve as the differential input stage for low-level biomedical signals when the system requires precise amplification with moderate bandwidth. Its 11 nV/√Hz noise density and 50 µV maximum offset are useful when extracting small sensor currents or differential voltages from a common-mode background. The 1 MHz bandwidth allows the amplifier to support sampled acquisition rather than only static measurements. The designer must still evaluate patient-safety isolation, leakage, electrode protection, and applicable medical requirements separately from the amplifier specification.
Được đề xuất
Current Shunt Measurement
The INA115AU/1K is appropriate for measuring the small differential voltage generated across a current-sense shunt. The low 50 µV maximum input offset reduces error near zero current, and the 11 nV/√Hz input noise supports detection of small shunt drops. Its 1 MHz bandwidth provides useful response for pulsed and dynamic current measurements. Keep the Kelvin sense connections paired and away from high-current switching paths so that voltage drops in the PCB traces do not become part of the measured signal.
Được đề xuất
Laboratory Test Equipment
The INA115AU/1K can serve as a precision analog front end in programmable instruments that measure low-level differential voltages. Its switched-gain architecture supports multiple sensitivity ranges, while 1 MHz bandwidth is useful for test systems requiring faster settling than a DC-only amplifier provides. The 3 mA power figure also helps when fitting several measurement channels into compact bench equipment. Establish gain accuracy, settling time, and output swing at each range using the manufacturer curves before setting acquisition timing.
Được đề xuất
Precision Industrial Data Acquisition
The INA115AU/1K supports precision industrial data-acquisition channels that must amplify weak differential sensor signals before conversion. Its 50 µV maximum offset, 11 nV/√Hz noise, and switched gain provide a practical balance between measurement resolution and dynamic range, while 1 MHz bandwidth accommodates faster sensor events. The 16-pin SOIC package is compatible with conventional surface-mount assembly methods. Provide stable supply bypassing and isolate analog input routing from motor, relay, and power-converter switching nodes to prevent coupled errors.
Được đề xuất
Portable Sensor Instrument
The INA115AU/1K fits portable sensor instruments where low power and precision amplification are both important. The manufacturer identifies a 3 mA power-consumption level, allowing multiple amplified channels to operate within a constrained power budget. The 11 nV/√Hz noise density is useful for extracting weak signals from resistive or magnetic sensors, while the 1 MHz bandwidth supports responsive measurements. Battery-powered designs should still verify supply current across operating modes and use power-gating or shutdown techniques where the device configuration permits them.
Được đề xuất
Tóm tắt các sản phẩm được đề xuất
Dữ liệu tham khảo kỹ thuật cho INA115AU/1K — so sánh, hướng dẫn thiết kế và thông tin tuân thủ.
Hướng dẫn chọn lựa
So sánh với các sản phẩm thay thế
| Tham số | Sản phẩm này | INA115AUG4 | INA115AU |
|---|---|---|---|
| Package | 16-pin SOIC (DW) | 16-pin SOIC (DW) | 16-pin SOIC (DW) |
| Brand | Texas Instruments | Texas Instruments | Texas Instruments |
| Product Type | Precision instrumentation amplifier | Precision instrumentation amplifier | Precision instrumentation amplifier |
| Channel Count | 1 channel | 1 channel | 1 channel |
| Gain-Bandwidth Product | 1 MHz | 1 MHz | 1 MHz |
| Maximum Input Offset Voltage | 50 µV | 50 µV | 50 µV |
| Input Noise Density | 11 nV/√Hz | 11 nV/√Hz | 11 nV/√Hz |
| Power Consumption | 3 mA | 3 mA | 3 mA |
| Gain Control | Switched gain | Switched gain | Switched gain |
Bảo phân biệt quan trọng
- Combines precision input performance with higher signal bandwidth (vsINA114AUE4)
- Switched gain supports multiple measurement ranges without changing the package (vsINA115AU)
- Low-noise precision in a compact surface-mount package (vsINA115AUG4)
Ghi chú thiết kế
Place the INA115AU/1K close to the bridge, shunt, or sensor output, and route the two differential inputs as a compact pair. Keep the gain-control and feedback components close to their associated pins, and avoid creating large copper loops around the precision input stage. A ground reference that follows the signal-source ground path is preferable to a path that passes through noisy switching-current loops.
Use local supply bypassing at the amplifier pins and keep the supply return compact. The INA115 is identified as a 3 mA-power device, but the exact supply current and output behavior still depend on operating conditions. Verify both positive and negative supply rails, startup behavior, and output swing at the selected gain in the manufacturer electrical-characteristics tables before defining the system power budget.
Treat gain changes as control events that can introduce transient settling into a precision measurement. Command the gain only after the source has reached its operating state, and allow the amplifier to settle according to the manufacturer gain-versus-settling behavior. For dynamic measurements, evaluate the 1 MHz bandwidth at the actual closed-loop gain rather than assuming full bandwidth is available at every setting.
Do not substitute INA115AU/1K solely because another device is described as an instrumentation amplifier. Confirm the 16-pin footprint, gain-control logic, supply range, offset, noise, bandwidth, temperature grade, and lifecycle status. In particular, verify the complete ordering suffix because /1K, G4, and legacy -1/1K designations may differ in packaging or qualification even when they identify closely related INA115 variants.
Thông tin tuân thủ
The available product and distributor records do not explicitly state the requested compliance attributes. Automotive qualification is treated as not applicable only because this ordering option is not identified as an AEC-Q100 variant.