INA155UG4 - 550 kHz R-R CMOS INA | Texas Instruments
MPN: INA155UG4 ✓ Hoạt độngINA155UG4 Tóm tắt
An instrumentation amplifier is a precision analog amplifier category designed for differential measurement systems. Its internal topology provides input common-mode rejection and gain-setting functions in a compact package. The INA155 belongs to the broader CMOS analog amplifier, signal-conditioning IC, and power-management-aware semiconductor hierarchy, making it suitable for sensor interfaces, current measurement, and compact data-acquisition systems.
The INA155UG4 provides rail-to-rail output swing, allowing the amplified signal to approach the supply limits. Its 550 kHz bandwidth supports moderate-frequency measurement signals, while the 6.5 V/ms slew rate helps preserve large-signal response. The low 200 uV input offset specification is important when measuring small differential voltages because offset error directly shifts the amplified result. A single 2.7 V to 5.5 V supply simplifies integration with low-voltage sensors and mixed-signal systems.
The CMOS implementation is optimized for low-voltage, single-supply operation. Rail-to-rail output operation improves usable output range without requiring a bipolar supply, although input and output headroom still depends on gain, load, supply voltage, and operating conditions. The INA155 family is intended for general-purpose differential amplification and for driving sampling analog-to-digital converters when signal bandwidth and settling behavior satisfy the converter requirements.
Typical uses include bridge-transducer interfaces, low-voltage current sensing, portable instrumentation, industrial measurement, medical monitoring, and general sensor conditioning. In these applications, the INA155UG4 converts a small differential input into a larger single-ended voltage suitable for an ADC, comparator, or downstream measurement circuit. Its 550 kHz bandwidth is appropriate for sensors whose useful signal content remains well below that frequency.
A key design consideration is to verify the selected gain against the device’s gain bandwidth and output-swing limits. Keep the input and return paths short, use a clean low-noise supply, and connect the reference or return input to the appropriate analog-ground point. Check the external gain-setting implementation against the manufacturer’s recommended resistance and layout guidance before sampling fast or low-amplitude signals.
Bộ thay thế dễ dàng lắp đặt cho INA155UG4 — cùng gói, chân-to-chân tương thích. Các bộ phận yêu cầu hàn PCB bị loại trừ.
Các biến thể trong loạt này
Các mẫu cùng loạt có thể lắp đặt dễ dàng tương thích với INA155UG4 (cùng hình factor và footprint) — khác nhau ở Product Type, Input Offset Voltage, Input Type, Output Swing, Output Type.
INA155U
✅ Drop-InLiên hệ để biết giá
Xem tài liệu →INA155UA
✅ Drop-InLiên hệ để biết giá
Xem tài liệu →INA155U/2K5
✅ Drop-In📋 Tham chiếu thay thế (không có trong danh mục)
INA155UG4 Tỷ lệ tối đa & tính chất điện
| Product Type | CMOS instrumentation amplifier |
| Number of Amplifiers | 1 circuit |
| Supply Voltage Range | 2.7 V to 5.5 V |
| Supply Configuration | Single supply |
| Input Offset Voltage | 200 uV |
| Gain Range | Up to 50 dB |
| Bandwidth | 550 kHz |
| Slew Rate | 6.5 V/ms |
| Output Swing | Rail-to-rail |
| Input Type | Differential input |
| Kiểu đầu ra | Single-ended rail-to-rail output |
| Hộp | 8-pin SOIC |
| Kiểu lắp đặt | Surface mount |
| Process Technology | CMOS |
Hướng dẫn cấu hình chân INA155UG4 8-pin soic
Cấu hình chân cho INA155UG4 (8-pin soic gói). Thành phần số hiệu này có chân đầu vào, đầu ra và nguồn cung cấp. Tham khảo tài liệu thông số kỹ thuật của nhà sản xuất để biết cấu hình chân bù, bù trừ và chân kích hoạt. Hoàn hảo cho điều kiện tín hiệu và mạch khuếch đại.
Không có dữ liệu chân cụ thể sẵn có cho INA155UG4.
Tham khảo: tài liệu kỹ thuật cho cấu hình chân đầy đủ.
Ứng dụng tiêu biểu
INA155UG4 phù hợp cho 6 Áp dụngs: Low-Voltage Current Sensing, Bridge Transducer Conditioning, Portable Medical Monitoring, Battery-Powered Sensor Interface, Industrial Data Acquisition, General Sensor Signal Conditioning.
Low-Voltage Current Sensing
The INA155UG4 is well suited to amplifying the small differential voltage produced by a low-side current-sense element in a 2.7 V to 5.5 V system. Its 200 uV input offset specification limits the input-referred error contribution, while the 550 kHz bandwidth accommodates many measurement, protection, and telemetry signals. Place the sense amplifier near the shunt when trace length could add resistance or pickup. Confirm the output swing and common-mode limits at the selected gain, then connect the amplified voltage to an ADC input or comparator.
Bridge Transducer Conditioning
A resistive bridge produces a small differential signal that requires amplification before digitization. The INA155UG4 provides differential amplification, rail-to-rail output, and a 6.5 V/ms slew rate from a single 2.7 V to 5.5 V supply, making it appropriate for compact bridge-based pressure, force, and position interfaces. Keep bridge excitation and the amplifier supply clean, route the differential inputs symmetrically, and verify that the operating gain remains within the bandwidth and output-swing limits.
Portable Medical Monitoring
Portable monitoring equipment often operates from a 3.3 V or 5 V rail while conditioning low-level physiological or diagnostic sensor signals. The INA155UG4 combines a 2.7 V to 5.5 V supply range, 200 uV input offset voltage, and rail-to-rail output to preserve signal amplitude in a restricted board area. Its 550 kHz bandwidth is suitable for many slow sensor waveforms. The final design must also satisfy the applicable medical-system safety, EMC, and validation requirements for the complete equipment.
Battery-Powered Sensor Interface
Battery-powered sensor nodes benefit from analog circuits that operate from a low single supply without requiring negative rails. The INA155UG4 accepts 2.7 V to 5.5 V and provides rail-to-rail output swing, helping utilize the available supply range when amplifying differential sensor signals. The 6.5 V/ms slew rate supports non-alternating waveforms with moderate frequency content. Verify input common-mode range and output headroom at the minimum battery voltage, and use a low-noise supply path to avoid degrading sensor accuracy.
Industrial Data Acquisition
The INA155UG4 can condition differential inputs from industrial sensors before they enter a sampling analog-to-digital converter. Its 550 kHz bandwidth and 6.5 V/ms slew rate are useful for moderate-bandwidth process and equipment measurements, while the 200 uV input offset specification supports precision-focused acquisition. Maintain short, symmetric input traces, reference analog ground correctly, and check the converter’s input range. A post-amplifier or filter may be required when the sensor bandwidth exceeds the amplifier’s gain-dependent response.
General Sensor Signal Conditioning
The INA155UG4 serves as a general-purpose differential signal-conditioning amplifier for compact measurement systems. Its 8-pin SOIC package, 2.7 V to 5.5 V supply range, and rail-to-rail output simplify integration with low-voltage analog and mixed-signal circuits. Use the device when the source is differential and the required signal bandwidth is compatible with the configured gain. Grounding, reference-pin connection, feedback layout, and output loading must follow the manufacturer’s recommended application circuit to preserve offset and settling performance.
Dữ liệu tham khảo kỹ thuật cho INA155UG4 — so sánh, hướng dẫn thiết kế và thông tin tuân thủ.
Hướng dẫn chọn lựa
So sánh với các sản phẩm thay thế
| Tham số | Sản phẩm này | INA155U | INA155UA | INA155U/2K5 |
|---|---|---|---|---|
| Package | 8-pin SOIC | 8-pin SOIC | 8-pin SOIC | 8-pin SOIC |
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
Bảo phân biệt quan trọng
- The specified INA155UG4 configuration combines a 550 kHz bandwidth with a 6.5 V/ms slew rate in an 8-pin SOIC package. (vsINA155U)
- Low-voltage single-supply operation is supported across a 2.7 V to 5.5 V range with rail-to-rail output. (vsINA155UA)
- A 200 uV input offset specification supports error-conscious differential signal conditioning. (vsINA155U/2K5)
Ghi chú thiết kế
Route the two differential inputs symmetrically and keep them away from switching nodes and high-current paths. The INA155UG4 uses 200 uV input offset voltage, so mismatched input routing, leakage through board contamination, and unintended thermal gradients can become significant in precision measurements. Use a solid analog-ground reference, minimize loop area, and follow the pin-description table and recommended application circuit in the TI datasheet when assigning the reference and feedback connections.
Confirm usable bandwidth at the actual gain rather than relying only on the 550 kHz headline value. The INA155UG4 also offers a 6.5 V/ms slew rate, but large output steps, capacitive loading, and a low supply voltage can limit settling performance. For an ADC interface, compare the amplifier’s gain-dependent bandwidth and settling behavior with the converter’s acquisition window. Add filtering only when its phase and noise effects are included in the system error budget.
Design the single supply for 2.7 V to 5.5 V operation while preserving a low-noise analog path. Place bypass capacitance close to the supply pins and avoid routing the amplifier supply directly through digital load currents. Check output headroom at the minimum supply voltage and maximum intended load because rail-to-rail output improves range but does not guarantee zero output error at the supply rail. Use the manufacturer’s output-voltage-versus-load characteristics when sizing the remaining analog headroom.
Thông tin tuân thủ
No specific compliance certification or material declaration is stated in the referenced product information.